Pile caps are concrete mats that rests on piles with adequate rigidity to transfer the column loads to the piles. Piles are
provided as alternatives to shallow foundations when a firm and stable soil to carry column load is too deep below the
surface, or when high lateral load is anticipated. More often than not, pile caps are usually so rigid that they make the entire
group of piles to behave like one unit. Welcome to the unique page of Structville
can easily download research papers, arti
drawings, textbooks, and even upload you
EN 1992-1-1:2004 permits us to use strut and tie models to analyse structures where non-linear strain distribution exists
(e.g. pile caps, deep beams and corbels).
STRUCTVILLE DESIGN MANUAL
In strut and tie models, trusses are used with the following components:
• Struts (concrete)
• Ties (reinforcement)
• Nodes (intersections of struts and ties)
https://www.structville.com/2018/04/structural-design-of-pile-caps-using.html 1/6
5/18/2018 Structural Design of Pile Caps Using Strut and Tie Model (EC 2) - Structville...
Design Example
A 500mm x 500mm column is carrying an ultimate limit state load of 2140 kN. We are to design the pile cap using the
You can purchase or download the previe
following data; highly interactive design manual by clickin
Follow
224 followers
ABOUT ME
Solution
The strut and tie model is as given below;
Watch on any
device
WATCH NOW
Angle of inclination of strut γ = tan-1 (1100/900) = 50.710°
cos γ = 0.633
sin γ = 0.7739
FOLLOW BY EMAIL
https://www.structville.com/2018/04/structural-design-of-pile-caps-using.html 2/6
5/18/2018 Structural Design of Pile Caps Using Strut and Tie Model (EC 2) - Structville...
Force in strut Fs = 1070/sinγ = 1382.6075 kN Enter your email address to subscribe to this blog
notifications of new posts by email.
Email address...
Force in tie Ft = 1382.6075 cos γ = 875.15 KN
SUBMIT
Area of tension steel required As = Ft/0.87Fyk = (875.15 × 1000) / (0.87 × 500) = 2011.8 mm2
Distance of this section from the column face; Analysis of Column Loads i
By Considering Beam Supp
av = 0.5(Spacing between piles - width of column) - 0.3(pile diameter) Reactions
av = 0.5(1800 - 500) - 0.3(600) = 470 mm
Preparation of Bar Bending
For Floor Slabs
Length of corresponding perimeter for punching shear
u = 2(900 + 1440) = 4680mm
PRACTICAL ANALYSIS AN
OF STEEL ROOF TRUSSES
Perimeter of pile cap = 2(900 + 2700) = 7200mm EUROCODE 3: A SAMPLE
Since the perimeter of the pile cap is less than 2u, normal shear extending across the full width of the pile cap is more What is wrong with this se
structural detailing?
critical than punching shear.
The contribution of the column load to the shear force may be reduced by applying a factor β = av/2d, where 0.5d ≤ av ≤ 2d Design of Pile Foundation
Load Test (Eurocode 7)
But a little consideration will show that av(470 mm) < 0.5d(550 mm), therefore, take av as 0.5d (550)
v = βV/bd
ρ1 = As/bd = 2185/(2700 × 1100) = 0.0007356 > 0.02; Therefore take 0.02 FOLLOW US
Facebook
VRd,c = [0.12 × 1.426 (100 × 0.0007356 × 30)(1/3)] = 0.2227 N/mm2
Twitter
Shear is ok.
Google+
https://www.structville.com/2018/04/structural-design-of-pile-caps-using.html 3/6
5/18/2018 Structural Design of Pile Caps Using Strut and Tie Model (EC 2) - Structville...
V = 2140 KN
Follow us on Instagram
v = V/ud
This shows that the punching shear around column perimeter is ok.
Like Page
Extra
Be the first of your friends to like this
This pile cap has been modelled on Staad Pro and the results obtained are given below.The set back in the model is the
piles were modelled as columns that could sway under the load. What do you think?
BLOG ARCHIVE
April (10)
TAGS
Thank you for visiting Structville today and God bless. Kindly share with your folks.
RECOMMENDED ARTICLES
https://www.structville.com/2018/04/structural-design-of-pile-caps-using.html 4/6
5/18/2018 Structural Design of Pile Caps Using Strut and Tie Model (EC 2) - Structville...
The use of timber as trussed rafters for roof of buildings is a very popular alternative all over the world. The
aim of this post is to show the desig...
Structural Design of Pile Caps Using Strut and Tie Model (EC 2)
Pile caps are concrete mats that rests on piles with adequate rigidity to transfer the column loads to the
piles. Piles are provided as alternatives t...
1 COMMENT:
Thank you Sir. Am pleased with this calculation is quite brief. Can I Design the Pile Cap with Software, Showing all
work procedures like this Manual Calculation you Did.
Reply
Publish Preview
Name
Home Ubani Obinna Ranks
Follow 224
Our Products and Services Email *
Purpose driven personality with a
About Us
Bachelors Degree (B.Eng) in Civil
Engineering from Nnamdi Azikiwe University, Awka.
Disclaimer
Passionate about civil engineering profession, and
Our Policies experienced in structural analysis and design.
View my complete profile
https://www.structville.com/2018/04/structural-design-of-pile-caps-using.html 5/6
5/18/2018 Structural Design of Pile Caps Using Strut and Tie Model (EC 2) - Structville...
Message *
Send
https://www.structville.com/2018/04/structural-design-of-pile-caps-using.html 6/6