Actuator-Sensor-Interface

Network Transitions
Introduction
Actuator-Sensor-Interface

■ Overview

Network transition
PROFIBUS AS-Interface
DP/AS-Interface Link 20E

DP/AS-Interface Link 65

S7-200

CP 243-2

BM 141 ET 200X
BM 142
0 1

BM 147 CP 142-2

ET 200M
IM 153
CP 343-2

CPU 31x-2
CP 342-5 S7-300
CP 342-5 FO CP 343-2
CP 343-5

Integrated DP
S5-95U
slave
interface CP 2433

IM 308C S5-115U
CP 5431 up to -115U
FMS/DP CP 2430
G_IK10_de_UE0010s

Siemens NS K · 2002 1/33


Actuator-Sensor-Interface
Network Transitions
DP/AS-Interface Link 20E
Actuator-Sensor-Interface

■ Overview
DP/AS-Interface Link 20E con- • All AS-Interface master func- Link_20e
nects PROFIBUS-DP to AS-In- tions are supported in ac-
terface. It supersedes DP/AS- cordance with the extended
Interface Link 20 and features AS-Interface specification
the following functions: V2.1, i.e. master class M1e.
• PROFIBUS-DP slave and • An additional power supply is
AS-Interface master not required, because power
is supplied from the AS-Inter-
• Up to 62 AS-Interface slaves
face cable
can be connected and inte-
grated analog value transfer
is provided (according to the
expanded AS-Interface spec-
ification V2.1).

■ Application
DP/AS-Interface Link 20E is a EN 50 295) and allows AS-Inter- Simple PROFIBUS masters can master calls. DP/AS-Interface
PROFIBUS-DP slave (accord- face to be operated on PROFI- exchange I/O data cyclically Link 20E cannot be implement-
ing to EN 50170) and an AS-In- BUS-DP. with AS-Interface and masters ed in combination with the ex-
terface master (according to with non-cyclic utilities can ex- tender.
change I/O data and perform

■ Design
• Compact enclosure to the • The PROFIBUS-DP address • Two buttons for changing the • Power is supplied from the
IP 20 degree of protection for can be set at the press of a operational status and for AS-Interface shaped cable.
mounting onto standard rails. button. loading the existing actual
configuration as the desired
• LEDs in the front panel for in- • LED indication of the PROFI-
configuration.
dication of the operational BUS-DP slave address, DP
state and the operational bus error and diagnostics.
readiness of all connected
and activated slaves.

■ Operation
DP/AS-Interface Link 20E ena- DP/AS-Interface Link 20E re- is stored. The I/O buffer can be PROFIBUS-DP masters can al-
bles a DP master to access all serves, as standard, 32 bytes of compressed so that only the so activate AS-Interface master
the slaves of an AS-Interface input data and 32 bytes of out- necessary memory space of calls via the non-cyclic PROFI-
segment. In accordance with put data in the DP master in the master is reserved. BUS utilities (e.g.: for writing
the expanded specification which the I/O data of the con- parameters, modifying ad-
(V2.1), up to 62 slaves each nected AS-Interface slaves dresses or reading diagnostic
with 4 inputs and 3 outputs can values).
be connected.

■ Configuration
DP/AS-Interface Link 20E can The type files and device mas- DP/AS-Interface Link 20E is not For AS-Interface, no special
be configured on PROFIBUS ter files are also supplied with yet integrated as standard. configuration is necessary; start-
using STEP 7 or COM PROFI- the manual which enables con- up is also possible before
BUS. figuration even in the case of PROFIBUS is installed.
versions in which

■ Designed for Industry


• Installation costs are re- power supply unit is required. • Installation time is shortened • The standstill time or service
duced because all power is due to easy configuring at the time resulting from failure of a
supplied from the AS-Inter- press of a button slave is reduced due to LED
face cable so no additional indication

1/34 Siemens NS K · 2002


Actuator-Sensor-Interface
Network Transitions
DP/AS-Interface Link 20E

■ Selection and ordering data


Design DT Order No. Price PG Pack

1 unit Unit
DP/AS-Interface Link 20E A 6GK1 415-2AA01 1
Network transition PROFIBUS-DP/
AS-Interface to the IP 20 degree of protection
DP/AS-Interface Link 20E manual
Paper version
Including type and device master files
• German B 6GK1 971-2DS01-0AA0 1
• English D 6GK1 971-2DS01-0AA1 1
• French D 6GK1 971-2DS01-0AA2 1
• Spanish C 6GK1 971-2DS01-0AA3 1
• Italian C 6GK1 971-2DS01-0AA4 1

■ Dimension drawings
Transition from PROFIBUS-DP to AS-Interface via DP/AS-Interface Link 20E

e.g. S7-400
with CPU 413-2 DP

PROFIBUS-DP

DP/AS-Interface
Link 20E

AS-Interface power supply unit

Passive module Active module


(without slave AISC) (with slave AISC)

Repeater 1)

AS-Interface power supply unit

AS-Interface cable Actuator/sensor (with slave ASIC) Actuator/sensor (without slave ASIC)
G_IK10_deN0006s

1) Use of extender not


Branch currently possible.

Siemens NS K · 2002 1/35


Actuator-Sensor-Interface
Network Transitions
DP/AS-Interface Link 20E

■ Technical data
AS-Interface bus cycle time in ms 5/10 for 31/62 slaves
PROFIBUS transmission rate in Mbit/s max. 12
Supported AS-Interface master profiles M0e, M1e
(corresponding to Complete AS-Interface Specification V2.1)
Configuration of the AS-Interface Via button on front panel
Interfaces
• Connection of AS-Interface Terminal contacts
• PROFIBUS connection 9-pin sub-D socket
Supply voltage
• From the AS-Interface cable acc. to AS-Interface specification EN 50 295
Current consumption
• from the AS-Interface shaped cable in mA max. 200
Load rating
• DC 5 V at PROFIBUS connection in mA max. 90
Power losses in W 3.7
Mounting Standard mounting rail or direct mounting
Protection IP 20
Permissible ambient conditions
• Operating temperature in °C
– horizontal mounting in °C 0 ... +60
– vertical mounting in °C 0 ... +45
• Transport and storage temperature in °C –40 ... +70
• Relative humidity in % max. 95 at +25 °C
Constructional design
• Module format S7-200 design
• Dimensions (W × H × D) in mm 90 × 80 × 60
• Weight in g approx. 200

1/36 Siemens NS K · 2002


Actuator-Sensor-Interface
Network Transitions
DP/AS-Interface Link 65
Actuator-Sensor-Interface

■ Overview
• Direct connection of • The advantages of PROFI- 7_10
Actuator-Sensor-Interface BUS-DP and AS-Interface are
to PROFIBUS-DP then ideally combined in a
common bus system
• IP 65 degree of protection
• DP/AS-Interface Link allows
the Actuator-Sensor-Inter-
face to be used as a sub-net-
work for PROFIBUS-DP

■ Application
Direct connection of This link can be connected to
Actuator-Sensor-Interface to any PROFIBUS-DP master that
PROFIBUS-DP. is capable of processing pa-
rameterization and diagnostic
DP/AS-Interface Link allows the
telegrams of 32 bytes in length
Actuator-Sensor-Interface to be
(e.g. IM 308 C, S5-95U/
used as a sub-network for
DP-Master or SIMATIC S7).
PROFIBUS-DP

■ Design
• Cast aluminium enclosure to • Diagnostics indication on the • It can be mounted in any po- • It is connected to AS-Inter-
the IP 65 degree of protec- cover for the PROFIBUS-DP sition and at any angle. face via a 4-pole molded con-
tion. and AS-Interface sections. nector (M12 to AS-Interface
• It is connected to PROFIBUS-
connection piece).
• This meets the requirements • The bus address can be set DP via a 12-pole circular con-
of the standard via a DIL switch or EEPROM. nector.
"Enclosures for Electrical The ET 200 handheld unit can
Equipment UL 50, Type 4" be used to set the address in
with regard to sealing against the EEPROM.
water penetration and is suit-
able for –25 °C to +60 °C.

■ Operation
DP/AS-Interface Link connects DP/AS-Interface Link can be In order to act as a bus coupler face and the functionality of a
PROFIBUS-DP to AS-Interface connected to any PROFIBUS- between the two bus systems, PROFIBUS-DP slave to
to the IP 65 degree of protec- DP master that is able to output DP/AS-Interface Link demon- PROFIBUS-DP.
tion. parameterization messages strates the functionality of an
with a size of 140 bytes. AS-Interface master to AS-Inter-

■ Parameterization
Up to 31 AS-Interface slaves DP/AS-Interface Link is, like all Information about configuration
can be connected to DP/AS-In- other components of the ET 200 can be obtained at any time
terface Link. DP/AS-Interface distributed I/O system, an inte- during operation of the parame-
Link is therefore, from the view- gral component of the COM terization software via a context-
point of PROFIBUS-DP, a modu- PROFIBUS parameterization sensitive Help function.
lar slave with up to 31 modules. software and STEP 7.

Siemens NS K · 2002 1/37


Actuator-Sensor-Interface
Network Transitions
DP/AS-Interface Link 65

■ Selection and ordering data


Design DT Order No. Price PG Pack

1 unit Unit
DP/AS-Interface Link A 6ES7 156-0AA01-0XA0 250 1
for connecting AS-Interface
to PROFIBUS-DP
Manual
DP/AS-Interface Link
• German A 6ES7 156-0AA00-8AA0 251 1
• English A 6ES7 156-0AA00-8BA0 251 1
• French A 6ES7 156-0AA00-8CA0 251 1
• Spanish A 6ES7 156-0AA00-8DA0 251 1
• Italian A 6ES7 156-0AA00-8EA0 251 1
Stabilized AS-Interface power supply B 6EP1 632-1AL01 400 1
SITOP power special line
DC/DC power supply
24 V/30 V, max. 2.4 A
to the IP 65 degree of protection
for supplying AS-Interface
AS-Interface socket A 6ES7 194-5AA00-0XA0 251 1
for connecting AS-Interface
to the DP/AS-Interface Link
PROFIBUS bus connector D 6ES5 760-2CB11 251 1
IP 66/67 degree of protection
for bus signals, power supply;
12-pole, with male insert

■ Technical data
PROFIBUS-DP transmission rate in Mbit/s max. 12
AS-Interface bus cycle time in ms 5 with 31 slaves
Interfaces
• Connection to PROFIBUS 2 × 12-pole plug-in equipment connector, 24 V supply
• Connection to AS-Interface 1 × 4-pole built-in connector
Supply voltage in V DC 24
Current consumption
• DP section (DC 24 V) in mA 100
• AS-Interface section in mA 70
Permissible ambient conditions
• Operating temperature in °C –25 ... +60
• Transport and storage temperature in °C –40 ... +70
• Relative humidity in % max. 95 at +25 °C
Constructional design
• Dimensions (W × H × D) in mm 205 × 80 × 57
• Weight in g approx. 800

1/38 Siemens NS K · 2002


Actuator-Sensor-Interface
Network Transitions
DP/AS-Interface Link 65

■ Cables and connectors


Configuration 1
Configuration example 1

Special SITOP Connector:


power line 6ES5 760-2CA11
24 V DC
AS-Interface
12-pin connector shaped cable, yellow:
with pin insert: 3RX9 010-0AA00
6ES5 760-2CB11

External power cable


24 V DC
DP/AS-Interface link
AS-Interface socket:
6ES7 194-5AA00-0XA0
T-connector:
6ES5 762-2CT11
PROFIBUS-DP

12-pin connector
2-wire cable: with pin insert:
6XV1 830-0AH10 6ES5 760-2CB11

2-wire cable:
6XV1 830-0EH10
4A-module
(slave)
All cables are also available with one with sensor
end preassembled and designed to
be resistant to electromagnetic fields.

G_IK10_deN0007s
For load infeed, a non-Siemens cable
can also be used provided that the
technical specification is complied
with.
PROFIBUS-DP AS-Interface

■ Cables and connectors


Configuration 2
Configuration example 2

Special SITOP Connector:


power line 6ES5 760-2CA11
24 V DC
AS-Interface
shaped cable, yellow:
3RX9 010-0AA00

Cable preassembled at one end, 5-core


with 12-pin round connector:
6ES5 717-6XXX1
DP/AS-Interface link
AS-Interface socket:
6ES7 194-5AA00-0XA0
T-connector:
6ES5 762-2CT11
PROFIBUS-DP

12-pin connector
with pin insert:
6ES5 760-2CB11

4A-module
(slave)
All cables are also available with one with sensor
end preassembled and designed to
be resistant to electromagnetic fields.
G_IK10_deN0008s

For load infeed, a non-Siemens cable


can also be used provided that the
technical specification is complied
with.
PROFIBUS-DP AS-Interface

Siemens NS K · 2002 1/39