STRUCTURAL CALCULATIONS TO BS 8110: 1997.

Job Ref: B.I.O Date : DEC 2018


Designed: DAMSHA Checked: I.M

STRESSES:
---------
fcu = 25.N/Sq. mm. fy = 410.N/Sq. mm. Pb = 410.kN/Sq. m.

LOADING/OVERHANG INFORMATION
----------------------------

A. Uniformly Distributed Load


Concrete Own Load 3.60kN/Sq. m.
Finishes, say 1.20kN/Sq. m.
Partition Allowance 1.20kN/Sq. m.
Other Loads 0.00kN/Sq. m.
-----
Total Dead Loads 6.00kN/Sq. m.
-----
Live Loads 1.50kN/Sq. m.

Total u.d.l = 10.80kN/m per m run

B. Point Load
Wall Load = 15.30kN/m.
Roof Load = 5.85kN/m.

Total Point Load = 21.15kN per m run

C. General Cantilever
Cantilever Span = 1.5m.
Cantilever Depth = 150.0mm.
Imposed Moment say 25..0 kN.m.
Area of Steel = 561.7Sq. mm.

Provide Y16mm @ 200mm c/c T.


Provide Y10mm @ 300mm c/c Distribution.
________________________________________________________________________
STAIR ANALYSIS AND DESIGN TO BS 8110

Job Ref: B.I.O Date : DEC 2018


Designed: DAMSHA Checked: I.M

DOG LEG (HALF-TURN) STAIR

-------------------------

Tread = 300. 0mm. Riser = 150.0mm.

Loading

-------

Own Weight = 4.20kN/m^2.

Finishes, say, = 1.20kN/m^2.

Steps load = 1.80kN/m^2.

Live load = 2.00kN/m^2.

Slope Factor = 1.114

Stair Uniformly Distributed Load = 14.17kN/m^2.

A. 1ST FLIGHT

-------------

Span = 3.850m. Waist = 150.0mm.

Moment = 19.815kN.m. Area of Steel req = 417.75Sq. mm.

Provide Y12mm @ 150mm c/c B.


Provide Y10mm @ 300mm c/c Distribution.

B. 2ND FLIGHT

-------------

Span = 4.075m. Waist =150.0mm.

Moment = 29.846kN.m. Area of Steel req = 666.36Sq. mm.

Provide Y12mm @ 150mm c/c B.

Provide Y10mm @ 300mm c/c Distribution.

C. HALF LANDING

----------------

Span = 1.1m. Depth = 150.0mm.

Total landing load = 39.53kN

Moment = 11.490kN.m. Area of Steel req = 246.37Sq. mm.

Provide Y12mm @ 150mm c/c B.

Provide Y10mm @ 300mm c/c Distribution.

D. FINAL LANDING

----------------

Span = 2.325m. Depth = 150.0mm.

Total landing load = 47.77kN.

Moment = 13.88kN.m. Area of Steel req = 299.94Sq. mm.

Provide Y12mm @ 150mm c/c B.

Provide Y10mm @ 300mm c/c Distribution.

________________________________________________________________________