PROJECT:- PROPOSED RESIDENTIAL DEVELOPMENT FOR DR.

BENEDICT
BAKWAPH KANYIP AT NO.768A ALONG 69(A)9 ROAD GWARINPA II,
ESTATE F.C.T ABUJA.

DESIGN TEAM

Client: DR.BENEDICT BAKWAPH KANYIP

Engineers: E+D CONSULT

Quantity surveyor: --------

Building services: -------

Checking authority: F.C.D.A.

PROJECT SUMMARY

Intended use RESIDENTIAL

Number of storey(s) ONE STORIE.

Fire resistance 1.0 HOUR

IMPOSED LOADS 1.5/m2

Wind speed 45M/S


Exposure conditions MILD/MODERATE
Subsoil conditions ALLOWABLE SOIL BEARING PRESSURE
USED IS 200KN/m2
CONSTRUCTION METHOD

Foundation type/s REINFORCED CONCRETE ISOLATED


PAD FOOTINGS.

Roof construction LONG SPAN ALUMINIUN ROOFING SHEET


ON TIMBER PURLINS & RAFTERS.

Floor construction MASS CONCRETE.


GROUND FLOOR ONLY)

Wall construction 230mm SANDCRETE BLOCKWALL.


WITH LONG SPAN ALUMINIUM SHEET.

Page 1 of 2
Timber grade/s N/A

Steel grade/s HIGH TENSILE STEEL OF FY=410N/MM2

Concrete grade/s Fcu=25N/mm2

Load bearing masonry 225MM BLOCKS: 2N/mm2

STRUCTURAL DESIGN

For limit state design codes, partial safety factors are:


Dead load =1.4, & imposed load =1.6, wind =1.2 with 0.9DL.
Structural provisions, where appropriate, are in accordance
with:BS 5950 'Structural use of steelwork in building' PART 1.
Code of practice for design in simple and continuous
construction: hot rolled sections. BS 8110 'Structural use of
concrete' Part 1. Code of Practice for design and construction.
5628 'Structural use of masonry' Part 1. Unreinforced masonry. BS
5268 'Structural use of timber' Part 2. Code of practice for
permissible stress design, materials and workmanship. BS 6399
'Design loading for buildings' Part 1. Code of practice dead and
imposed loads (Formerly CP3: Chap V: Part 1) Where deemed
necessary, BS449 was adopted in checking member size adequacy.