You are on page 1of 1

NATIONAL TECHNICAL SERVICES

F.D.T Test Report by Sand Replacement Method


Name of Project : Watch Tower (NDP)_ Date : 19-12-2018
Material : Base Of Watch Tower
Identification : soil compaction

Weight of wet Material (g) 3668


Weight of Cone + Sand (Before Used) Grams 7244
Weight of Cone + Sand ( After Used ) Grams 3042
Weight of Sand to Fill Hole & Cone (g) 4202
Field Density Weight of Sand to Fill Cone (g) 1596
Weight of Sand to Fill Hole (g) 2606
Unite Weight of Sand (g/c.c ) 1.373
Volume of Hole (c.c ) 1898
Wet Density (g/c.c ) 1.93
Moisture Content % Moisture Content % 14%
Dry Density (g/c.c ) 1.695
Maximum Dry Density ( g/c.c ) 1.73
Lab Density & O.M.C Optimum Moisture Content % 16.20%
Compaction Obtained % 97.99%
Result Compaction Required % 98
( pass \ Fail ) Pass

___________________________

National Technical services Pvt. Ltd. Representative SPL (NDP)

Site Engineer ______________ Client Representative ___________