** TDW SLEEVE CALCULATION **

REINFORCEMENT OF WELDED BRANCH CONNECTION - ASME B31.8, 2016 EDITION page 1 of 1


CUSTOMER: GS OIL & GAS BRANCH HOOP STRESS OK
PO / ETO#: ETO 7953 RUN HOOP STRESS OK
TDW PRODUCTION PART NO: 12354978 ADEQUATE REINFORCEMENT
CUSTOMER DWG PART NO: CD00001530

BR_SZ: 8 = NOMINAL BRANCH SIZE, in.


RUN_SZ: 18 = NOMINAL RUN SIZE, in.
P_dsgn: 1320 = DESIGN PRESSURE, psi
T_dsgn: 104 = DESIGN TEMPERATURE, deg. F
SFD: 0.5 = DESIGN FACTOR (PER TABLE 841.114A)
CA: 0.000 = CORROSION ALLOWANCE, in.
BKUP_STRP: YES = BACK-UP STRIPS REQUIRED?
Sb: 36000 = SMYS of BRANCH, psi ASTM A350 LF2 CL1 = BRANCH MATERIAL
Sh: 50000 = SMYS of RUN, psi ASTM A537 CL1 (2. = RUN MATERIAL
EJF_BR: 1.0 = BRANCH LONGITUDINAL JOINT FACTOR (PER TABLE 841.115A & PARA. 817.13(d))
EJF_RN: 1.0 = RUN LONGITUDINAL JOINT FACTOR (PER TABLE 841.115A & PARA. 817.13(d))
T_derate: 1.0 = TEMPERATURE DERATING FACTOR (PER TABLE 841.116A)
Tb: 1.000 = NOMINAL BRANCH WALL THICKNESS, in.
BID: 7.981 = NOMINAL BRANCH ID, in. Db: 9.981 = NOMINAL BRANCH OD, in.
Lb: 3.000 = NOMINAL LENGTH OF BRANCH, in.
Th: 0.875 = NOMINAL RUN WALL THICKNESS, in.
RID: 18.220 = NOMINAL RUN ID, in. Dh: 19.970 = NOMINAL RUN OD, in.
Lh: 16.000 = NOMINAL LENGTH OF RUN, in. 15.962 = MAX WIDTH OF REINF ZONE
M: 0.000 = THICKNESS OF ADDED REINFORCEMENT, in.
A3: 0.000 = SUMMATION OF AREA OF ALL ADDED REINFORCEMENT, sq.in.
FLAT: 0.690 = NOMINAL FLAT WIDTH ON ENDS OF RUN, in.
ANG: 45.0 = NOMINAL ANGLE OF CHAMFERS ON ENDS OF RUN, deg.
A4: 0.028 = NOMINAL AREA LOST DUE TO CHAMFERS ON ENDS OF RUN, sq.in.

REQUIRED BRANCH WALL THICKNESS, NOT INCLUDING CA:


tb: 0.366 = (P_dsgn*Db)÷(2*Sb*SFD*EJF*T_derate), in.
EXCESS THICKNESS IN BRANCH WALL:
0.634 = Tb-tb-CA, in.
REQUIRED RUN WALL THICKNESS, NOT INCLUDING CA:
th: 0.527 = (P_dsgn*Dh)÷(2*Sh*SFD*EJF*T_derate), in.
EXCESS THICKNESS IN HEADER WALL:
0.348 = Th-th-CA, in.
LENGTH OF OPENING INCLUDING CA:
d: 7.981 = (Db-2*Tb+2*CA), in.
REINFORCEMENT REQUIRED:
Ar: 4.208 = (d*th), sq.in.
REINFORCEMENT PROVIDED BY HEADER:
A1: 2.776 = Lesser of d*(Th-th-CA) or (Lh-d)*(Th-th-CA), sq.in.
REINFORCEMENT PROVIDED BY OUTLET:
L: 2.188 = Lesser of 2.5*(Th-CA), 2.5*(Tb-CA)+M or Lb+M, in.

A2: 2.774 = 2*L*(Tb-tb-CA), sq.in.

A2_eff: 1.997 = A2*(Sb÷Sh) (Sb÷Sh not to exceed 1.0)

AREA AVAILABLE FOR REINFORCEMENT:


A1+A2+A3-A4: 4.745 ≥ Ar = ADEQUATE REINFORCEMENT

PRINTED ON: 01/30/19 LATEST REVISION: AU


THIS IS PROPERTY OF T.D. WILLIAMSON. THE INFORMATION IS NOT TO NOTES:
TD WILLIAMSON BE USED EXCEPT AS EXPRESSLY AUTHORIZED BY THIS COMPANY.

TULSA,OKLAHOMA USA COPIES ARE NOT TO BE MADE WITHOUT PERMISSION.

*** CLIENT COPY *** BY/DATE: KDH 1/11/2019