You are on page 1of 10

ONE WAY SLAB DESIGN

I. DESIGN CRITERIA:
Material Specifications:
Yeild Strength of Steel (main bar), f y: 275 MPa
Yeild Strength of Steel (temp. bar), fy: 276 MPa
Specified Compressive Stress of Concrete, f'c: 20.69 MPa
Factors:
Dead Load: 1.4

Live Load: 1.7

Strength Reduction, ф: 0.9 *SEE NSCP 2010


Loadings:
a. Dead loads:
Concrete = 23.5 kN/m3

Ceiling (Wood Furring) = 0.12 kPa

Ceramic tile = 0.77 kPa


Cement Fill = 0.15 kPa
Electrical Utilities = 0.12 kPa
Mechanical Utilities = 0.2 kPa
add kPa
add kPa
add kPa
add kPa
add kPa
Micellaneous = 0.1 kPa
b. Live loads:
Basic Floor Area = 1.9 kPa
Exterior Balconies = 2.9 kPa
Roof Decks = 1.9 kPa
add kPa
add kPa
add kPa
add kPa
add kPa
add kPa
II. DIMENSION
Longer Span, La: #REF! mm

Shorter Span, Lb: #REF! mm

Minimum slab thickness: 90 mm* *SEE NSCP 2010


Main Bar Diameter: 10 mm
Temperature Bar Diameter: 10 mm
Concrete Cover: 20 mm see
Effective Depth, d: 65 mm
III. LOADS
Total Live Load Pressure, LL: 1.9 kPa
Total Factored live load: 3.23 kPa
Dead Load Pressure, DL: 1.16 kPa
Weight of Slab: 2.115 kPa
Total Factored Dead Load: 4.585 kPa
Total Factored Floor Pressure: 7.815 kPa
Factored Uniformly Distributed Load, wu: 7.815 kN/m

IV. REQUIRED STEEL REINFORCEMENT


β1 = 0.85 0.85 SEE NSCP 2010
ρmin = 0.005091
ρmax = 0.02796
At midspan:
Mu = #REF! kN-m SEE NSCP 2001
Ru= #REF! MPa
ρ = #REF! ρ1 = #REF!
Use ρ = #REF!

Required Steel Area, Ast: #REF! mm2


Spacing, S: (use the smallest)
a. S1 = #REF! mm ≈ 200 mm
b. 3h = 270 mm ≈ 250 mm
c. = 450 mm
Thus, use 10 mm diameter bottom bars at 200 mm on center at Midspan
At Left Support:
Mu = #REF! kN-m SEE NSCP 2001
Ru= #REF! MPa
ρ = #REF! ρ1 = #REF!
Use ρ = #REF!
Required Steel Area, Ast: #REF! mm2
Spacing, S: (use the smallest)
a. S1 = #REF! mm ≈ 200 mm
b. 3 times slab thickness = 270 mm ≈ 250 mm
c. = 450 mm
Thus, use 10 mm diameter bottom bars at 200 mm on center at Supports
At Right Support:
Mu = #REF! kN-m SEE NSCP 2001
Ru= #REF! MPa
ρ = #REF! ρ1 = #REF!
Use ρ = #REF!

Required Steel Area, Ast: #REF! mm2


Spacing, S: (use the smallest)
a. S1 = #REF! mm ≈ 200 mm
b. 3 times slab thickness = 270 mm ≈ 250 mm
c. = 450 mm
Thus, use 10 mm diameter bottom bars at 200 mm on center at Supports
Temperature Bars:
ρt = 0.002 SEE NSCP 2010
Ast = 180 mm2
Spacing, S: (use the smallest)
a. S2 = 436.332 mm ≈ 400 mm
b. 5 times slab thickness = 450 mm ≈ 450 mm
c. = 450 mm
Thus, use 10 mm diameter bottom bars at 400 mm on center at Midspan

RESULT: 90 mm thick slab


10 mm main bars spaced 200 mm on center
10 mm main bars spaced 400 mm on center
BEAM DESIGN

I. DESIGN CRITERIA:
Material Specifications:
Yeild Strength of Steel (main bar), f y: 275 MPa
Compressive Stress of Concrete, f'c: 20.7 MPa
Concrete Unit Weight: 23.54 kN/m3
Factors:
Dead Load: 1.1
Live Load: 1.2
Strength Reduction, ф: 0.9 *SEE NSCP 2010

II. DIMENSION
Base Width, b: 200 mm 200
Height, h: 400 mm
Main Bar Diameter, db: 16 mm 4500

400
Concrete Cover: 40 mm
Effective Depth, d: 352 mm
Total Width of Slab: 5000 mm
Length of Beam: 4500 mm
Assumed Slab Thickness: 100 mm

III. LOADINGS:

Total Live Load: 1.9 kPa


Beam Weight: 1.88 kN/m
Slab Weight: 11.77 kN/m
Other: 0.5 kPa

Factored Uniformly Distributed Load, w u: 29.17 kN/m

III. REQUIRED STEEL REINFORCEMENT


Mu max:
β1 = 0.85
0.0050909
0.0279692

0.3716

133.93534 kN-m 272 kN-m

At Suppots:
Computed Mu: 59.066253 kN-m SEE NSCP 2001

Ru= 2.6483879

ρ= 0.01049

Required Steel Area, Ast: 738.53254 mm2

No. of bar: 3.6731595 pcs


say 4 pcs

At Midspan:

Computed Mu: 42.190181 kN-m SEE NSCP 2001

Ru= 1.8917056

ρ= 0.00729

Required Steel Area, Ast: 513.55256 mm2

No. of bar: 2.5542009 pcs


say 3 pcs

As1 = 1969.03 mm2


Mu1 = 133.93534 kN-m
Mu2 = 138.06466 kN-m
As2 = 1787.9391 mm2
a= 153.87429 mm
c= 181.03 mm
f's = 467.42424 MPa

As = 3756.97 mm2
A's = 1787.9391 mm2

# of Top Bars 18.685638 pcs 14


# of Bottom Bars 8.8924795 pcs 4
4500
5000
BEAM

I. DESIGN CRITERIA:
Material Specifications:
Yeild Strength of Steel (main bar), f y: 275 MPa
Compressive Stress of Concrete, f'c: 20.7 MPa
Strength Reduction, ф: 0.9 *SEE NSCP 2010
II. DIMENSION
Base Width, b: 200 mm
Height, h: 400 mm
Concrete Cover: 40 mm
At Suppots:
Bar Diameter, db: 16 mm
Effective Depth, d: 352.0 mm

Number of Top Bars: 2 pcs


Number of Bottom Bars: 2 pcs
Area of Top Bars, As: 402.12 mm2
Area of Bottom Bars, A's: 402.12 mm2
At Midspan:
Bar Diameter, db: 16 mm
Effective Depth, d: 352.0 mm

Number of Top Bars: 2 pcs


Number of Bottom Bars: 2 pcs
Area of Top Bars, A's: 402.12 mm2
Area of Bottom Bars, As: 402.12 mm2
II. COMPUTED FACTORED MOMENT
β1 = 0.85
FOR DOUBLY REINFORCED BEAM
At Suppots: At Suppots:
A's = 402.12 mm2 β1 = 0.85
As2 = 402.12 mm2 ρb = 0.0543845
As1 = 0.00 mm2 ρmin = 0.0050909
a= 0 mm ρ= 0.00571
c= 0.00 mm w 0.0758839
f's = #DIV/0! MPa Computed Mu: 33.46455 kN-m
Computed Mu: 31.052004 kN-m
At Midspan: At Suppots:
A's = 402.12 mm2 β1 = 0.85
As2 = 402.12 mm2 ρb = 0.0543845
As1 = 0.00 mm2 ρmin = 0.0050909
a= 0 mm ρ= 0.00571
c= 0.00 mm w 0.0758839
f's = #DIV/0! MPa Computed Mu: 33.46455 kN-m
Computed Mu: 31.052004 kN-m