DESIGN OF BASE PLATE FOR PIPE Inputs

Column Pipe Section P406.00mm (pipe dia)


Height of Stanchion h = 6.20m
Ph1 = 10.00 KN (Friction force)
Ph2 = 10.00 KN (Wind force against Friction and structure)
N = 56 KN
Dimension of Base Plate D = 0.650 m b = 0.650 m
Dia. Of anchor Bolt = 0.030 m No of Anchor bolt in either dir. = 3
Anchor Bolt capacity Tension = 65 KN Shear = 30 KN
Grade of Concrete = 21 N/mm2
Steel yield Strength = 235 N/mm2
dt = 0.060 m
dt /3 = 0.020 m
d = 0.590 m
M = 62.00 KN-m
e = 1.107 m

Tension Force Effects :-

D/6 = 0.108 m
(D/6 + dt/3) = 0.128 m

3- Tension force affects (Anchor Bolts) бc = 2N(e+D/2-dt) / (b.Xn(d-dt-Xn/3)), Z = N(e-D/2+Xn/3)

x/d = (e-D/2) / d
x/d = 1.326
r = at / (b.d)
r = 0.006
Xn/d = 0.4 (From Graph)
Xn = 0.24 m

So σc1 = 1.82 N/mm2


Z1 = 87.43 KN (Per 3 Anchor Bolts)

For Ph2 = 10.00 KN


M = 62.00 KN-m
e = 1.107 m
3- Tension force affects (Anchor Bolts) бc = 2N(e+D/2-dt) / (b.Xn(d-dt-Xn/3)), Z = N(e-D/2+Xn/3)

x/d = 1.326
Xn/d = 0.45 (From Graph)
Xn = 0.27 m

σc2 = 1.62 N/mm2


Z2 = 88.43 KN (Per 3 Anchor Bolts)

CHECKS

1- Compression Check of Concrete

(σc1 + σc2) / fc' = 0.163 OK


2- Anchor Bolt Check

i) Tension
(Z1+Z2) /no. of bolt = 58.62 KN
(Z1+Z2) /no. of bolt /(Anchor Bolt Tension Capacity) = 0.90 OK

ii) Shear
((Ph12 +Ph22) ^0.5 /8) /Anchor Bolt Shear Capacity

0.167 OK
Combination of Anchor Bolt Shear force shall be checked
1.069 OK

3- Check Of Base Plate Thickness

i) Compression

l = 172 mm
b = 294 mm
therefore l/b = 0.584

Mx = 0.06 σc b2
My = -0.27285019 σc l2
Mx = 8784.63 N-mm/mm
My = -13003.16 N-mm/mm

t = (6*Mmax / fb)^0.5
t = 20 mm

ii) Tension

Z = bt2 / 6
b = 159 mm
Z = 27 t^2

σ = Me / Z < fb
M = (Z1+Z2) /3
fb = 0.66 fy 1.25

t > 51 mm TEFLON SHEET ARE USED