Calculation of Flat Covers according to UG-34

(according to ASME Section VIII, Division 1, 2015 Edition, UG-34 (h))

drawing no.:
Item:
design pressure: P = 4,60 MPa
inner diameter D = 77,92 mm
material of plate SA-479 321 (1.4541)
temperature T = 100,00 °C
allowable stress at temperature S = 138,00 N/mm²
factor C C= 0,33
thickness of plate t = 16,50 mm
corrosion allowance c = 0,00 mm
joint efficiency E= 1

Required thickness of unstayed plate:

treq= 8,17 mm

Actual thickness: Required thickness:

16,50 mm > 8,17 mm OK

status 0 T:\Design Verifications\00-Vorlagen\Excel\VIII-1\UG-34-h covers


Calculation of Flat Covers according to UG-34
(according to ASME Section VIII, Division 1, 2015 Edition, UG-34 (h))

drawing no.:
Item:
test pressure: P = 6,85 MPa
inner diameter D = 77,92 mm
material of plate SA-479 321 (1.4541)
temperature T = 15,00 °C
allowable stress at temperature S = 184,50 N/mm²
factor C C= 0,33
thickness of plate t = 16,50 mm
corrosion allowance c = 0,00 mm
joint efficiency E= 1

Required thickness of unstayed plate:

treq= 8,62 mm

Actual thickness: Required thickness:

16,50 mm > 8,62 mm OK

status 0 T:\Design Verifications\00-Vorlagen\Excel\VIII-1\UG-34-h covers


status 0 T:\Design Verifications\00-Vorlagen\Excel\VIII-1\UG-34-h covers