AWS D1.1/D1.1M:2015 CLAUSE 4.

QUALIFICATION

Notes:
1. The groove configuration shown is for illustration only. The groove shape tested shall conform to the production groove shape that is
being qualified.
2. When CVN tests are required, the specimens shall be removed from their locations, as shown in Figure 4.28.
3. All dimensions are minimum.

Figure 4.6—Location of Test Specimens on Welded Test Plate


Over 3/8 in [10 mm] Thick—WPS Qualification (see 4.9)

145
AWS D1.1/D1.1M:2015 CLAUSE 4. QUALIFICATION

INCHES MILLIMETERS
Weld Weld
Size T1 min. T2 min. Size T1 min. T2 min.
1/8 1/4 3/16 3 6 5
3/16 1/2 3/16 5 12 5
1/4 3/4 1/4 6 20 6
5/16 1 5/16 8 25 8
3/8 1 3/8 10 25 10
1/2 1 1/2 12 25 12
5/8 1 5/8 16 25 16
3/4 1 3/4 20 25 20
> 3/4 > 1 1 > 20 > 25 25
Note: Where the maximum plate thickness used in production is less than the value shown above, the maximum
thickness of the production pieces may be substituted for T1 and T2.

Figure 4.15—Fillet Weld Soundness Tests for WPS Qualification (see 4.12.2)

153