You are on page 1of 15

Voluson S6 BT12

Extraordinary vision: Signature Series


Product Description
The Voluson* S6 offers the right mix of capabilities for enhancing your productivity through extraordinary 2D image quality,
volume imaging capabilities, automation tools, easy-to-learn workflow, all combined in an innovative ergonomic design.

Highlights
• Lightweight and portable
• High Resolution Flat Panel Display 19”
• Real-Time 4D
• 3D Multiplanar Display
• 3D Power Doppler
• Automatic Optimization (AO)
• CrossXBeamCRI* (CRI)
• Advanced VCI with Single View
• SonoAVC*follicle
• SonoNT
• SonoRenderStart
• Scan Assistant
• Anatomical M-Mode
• On Board Archive including Preview
and Pre-selection
General specifications System overview
Dimensions and weight Applications
Height: Adjustable Min: 975 mm (38.4 in) Obstetrics
Max. 1725 mm (67.9 in) Gynecology
Width 620 mm (24.4 in) Abdominal
Depth 850 mm (33.4 in) Small-Parts
Weight (no Peripherals) 198lb/90kg Vascular
Pediatrics
Electrical power Cardiology
Voltage 100-120VAC, 220 – 240VAC Urology
Frequency 50/60 Hz Musculoskeletal (MSK)

Console design Operating modes


3 Active Probe Ports B-Mode (2D)
1 Parking Port M-Mode (conventional M-Mode)
Integrated HD (500 GB) AMM (Anatomical M-Mode)
3 USB Ports for External Peripherals PW Doppler with high PRF (PW)
2 USB Ports for On-board Peripherals High PRF Doppler Mode
RJ45 LAN Port Color Flow Doppler Mode (CFM)
1 HDMI Out Port Power Doppler Mode (PD)
1 AUDIO Out Port HD-Flow* Doppler Mode (HD-Flow)
Tissue Doppler Mode (TD)
User interface M-Mode Flow Modes (M/CF, M/HD-Flow, M/TD)
Operator keyboard Volume Mode (3D/4D):
Backlit alphanumeric keyboard • 3D Static
Ergonomic hard key layout • 4D Real Time
• Advanced VCI-SingleView
Interactive back-lighting
Extended View (XTD View)
Programmable print/store/export keys for printing,
archiving and exporting
Scanning Methods
Monitor Electronic Convex
High-Resolution 19-inch TFT LCD Screen Electronic Linear
Resolution 1280 x 1024 Mechanic Volume Sweep
Image size: 960 x 720
Transducer Types
High brightness with 220 cd/m2 typical
Convex Array
Digital brightness and contrast adjustment
Linear Array
Brightness/Contrast/Dim Brightness Control
Phased Array
Volume probes ‘4D’:
• Convex Array
• Microconvex Array
System overview (cont.)
System Standard Features Peripheral Options
3D/4D Mode Integrated Printers:
Innovative user interface with onscreen menus • B/W Printer
• Color Printer
HD-Flow
• DVD Recorder
Automatic Tissue Optimization
Bluetooth Line Printer
Coded Excitation (CE)
ECG Digital Module
Coded Harmonic Imaging with Pulse Inversion Technology
Foot Switch with programmable functionality
Tissue Doppler
Advanced SRI (Speckle Reduction Imaging) Display Modes
CrossXBeamCRI (Compound Resolution Imaging) Simultaneous Capability
Scan Assistant • B + PW
B Mode only • B + CFM, B + PD, B + TD, B + HD-Flow
• B + M, B + AMM • B + 3D, B + 4D
B + Power Doppler Mode
• B + CRI • B + SRI
B + CFM Doppler Mode • B + SRI + CRI • BF + SRI
B + HD-Flow Mode • B + SRI/4D + SRI • B + CRI/3D + CRI
B + CRI • B + CRI + SRI/3D + CRI + SRI • B + CRI/4D + CRI
• B + SRI/4D + SRI • B + CRI + SRI/4D + CRI + SRI
B + CRI + CFM
• B/B + SRI • B/CFM + CRI
B + CRI + PD • B/CFM + SRI • B/CFM + CRI + SRI
B + CRI + HD-Flow • B/PD + CRI • B/PD + SRI
Focus & Frequency Composite (FFC) • B/PD + CRI + SRI • B/HD-Flow + CRI
High Resolution Zoom • B/HD-Flow + SRI • B/HD-Flow + CRI + SRI
• B/CFM/PW • B/PD/PW
Pan Zoom • B/HD-Flow/PW • B/TD/PW
SonoRenderStart • B/M/CFM • B/M/HD-Flow
Steering • B/M/TD • B/AMM/CFM
Virtual Convex • B/AMM/HD-Flow • B/AMM/TD
Wide Angle on endovaginal probes Real-time Triplex Mode
Beta-View Selectable alternating modes
• B + PW • B/CFM + PW
Patient information database
• B/PD + PW • B/HD-Flow + PW
Image Archive on hard drive • B + CFM or PD or HD-Flow
3D/4D data compression (lossy/lossless) • B/TD + PW
Real-time automatic Doppler calcs Multi-image (split, quad)
Measurement & Calculations including Worksheets/Report for: • Live and/or frozen
• OB • GYN • Split: B + B, B/CFM + B/CFM or B/PD + B/PD or B/TD + B/TD
• Vascular • Cardio or B/HD-Flow + B/HD-Flow or BF + BF
• Abdominal • Small-Parts • Split simultaneous: B + B/CFM or B + B/PD or B + B/HD-Flow
• Urology • Pediatrics • Split: B + PW or M
• Musculoskeletal • Neurology • Split: Frame Review/XTD-View
• Quad: B + B + B + B or BF, B/CFM + B/CFM +
B/CFM + B/CFM or B/PD or B/TD or B/HD-Flow
System Options
• Independent Cine playback
3D/4D Advanced • Quad: A + B + C + 3D or 4D
Advanced VCI with SingleView (Volume Contrast Imaging) • Segmentation: quad (A/B/C/Segm. Object), single
4D View PC Software (Segm. Object)
DICOM 3 Zoom Read/Write (with or without overview image)
XTD Colorized Image
• Colorized B • Colorized M
Anatomical M-mode
• Colorized PW • Colorized 3D
SonoVCADlabor
Time line display
• Independent Dual B/PW Display
• Display Formats
• Top/Bottom selectable format (Size: 1/2:1/2; 1/3:2/3; 2/3:1/3)
Left/Right format (Size: 1/2:1/2)
Display Annotation
Patient Name: 3D/4D Mode
• Last: max 32 characters • 3D/4D Sub Program • Threshold
• First: max 15 characters • Quality • Volume Box Angle
• Middle: max 15 characters • Mix • Acquisition Mode
ID: max 32 characters • Compression • Orientation Markers
• VCAD Heart
Secondary patient ID (Citizen Service Number)
TGC Curve
Accession #: max 16 characters
Cine Frame Number
Hospital Name: 30 characters
Recorder Status
Sonographer (up to 5 characters are displayed depending on
font size) Body Pattern: 130 types organized in 10 anatomical groups
Gestational age (OB) or LMP (Gyn) Measurement Results
Birth date (selectable) Displayed Acoustic Output
• TIS: Thermal Index Soft Tissue
Date: 3 Types selectable • TIC: Thermal Index Cranial (Bone)
• MM/DD/YYYY • TIB: Thermal Index Bone
• DD.MM.YYYY • MI: Mechanical Index
• YYYY/MM/DD
Power Output
Time: 2 types selectable
• 24 hours Biopsy Guide Line
• 12 hours ECG Line
Probe Name Trackball function
Application Name Zoom overview image (zoom box position)
Gray Scale bar GE Logo
Depth Scale
Focal Zone marker System Parameters
Frame Rate System Setup
Zoom Start/Depth Pre-programmable categories date format
B-Mode User Programmable Preset Capability, User program, etc.
• User program • Acoustic Power Languages: English, French, German, Spanish, Italian,
• Receiver Frequency • Gain Norwegian, Dutch, Finnish, Swedish, Danish, Chinese,
• Dynamic Contrast • Gray Map Japanese, Russian
• Edge Enhance • Persistence EUM Languages: English, German, Spanish, Italian, French,
• SRI, CRI • Focal Zone Markers Russian
• Depth Scale Marker • Probe Orientation
Up to 400 Programmable Annotations organized in 10
M-Mode/ AMM-Mode anatomical groups
• Gain • Dynamic Contrast
Programmable Scan assistant lists including Add, Delete, Edit
• Edge Enhance • Reject
and Reorder of checklist items
• M-Cursor, AMM-Cursor • Time Scale
Four programmable Px buttons for documentation preferences
Doppler Mode
like Save, DICOM Send, Print, Check, Cine length etc.
• Acoustic Power • Gain
• Angle • Wall Motion Filter Several user configurable functions:
• Velocity or Frequency Scale • Spectrum Inversion • Clinic Name
• Time Scale • PRF • Display (TGC curve, Screen Lock, Screensaver, Auto Scan
• HPRF • Doppler Frequency Stop, Beeper, 3D/4D Screen Controls)
• Sample Volume Depth and Width • Trackball speed
• Dim function
Color Flow Imaging Mode (CFM, PD, TD, HD-Flow)
• Zoom: Overview window
• Acoustic Power • Color Gain
• Patient Info display
• Color Balance • Color Balance Marker
• Title bar settings
• Quality • Wall Motion Filter
• Start Exam & End Exam Configuration
• PRF • Color Map
• Color Scale: kHz, cm/s, m/s Power and Symmetrical
Velocity Imaging
• Spectrum Inversion
Image Processing and Presentation
Measure Setup Digital Beamformer
M&A Setup including Add, Delete, Edit and Reorder of System processing channel counts up to 226,626 by
measure items configuration
Application Setup including several parameters of Minimum Depth of Field: 0 – 1 cm (Zoom, probe dependent)
Measurement, Doppler Trace and Calculation presets Maximum Depth of Field: 0 – 36 cm (probe dependent)
Global Setup including several parameters of Measurement, Transmission Focus 1-5 Focus Points selectable (probe and
Cursor and Result window presets application dependent)
Focal Zone position, up to 7 steps
Biopsy Setup
Continuous Dynamic Receive Focus / Continuous Dynamic
User programmable needle guidelines Receive Aperture
256 shades of gray
Pre-Processing
16.8 Million Colors 24 bit
Write Zoom up to 8x Up to 261dB Processing Dynamic Range
B/M-Mode Image Reverse: Right/Left, Rotation: 0°, 180°
• Gain • TGC
• Dynamic Range • Acoustic Output Cine Features
• Transmission Focus Position • Transmission Focus Number
• Transmission Frequency • Edge Enhancement Cine Features:
• Persistence Control • Line Density Control • Dual/Quad Image CINE Display
• Reject • Sweep Speed • CINE Gauge and CINE Image number display
• M-Cursor position • CINE Review Loop
• Selectable CINE Sequence for CINE Review
PW-Mode (by Start Frame and End Frame)
• Gain • Dynamic Range • Side Change in dual CINE Mode
• Acoustic Output • Transmission Frequency • Measurements/Calculations & Annotations on CINE
• PRF • Wall Motion Filter
• Sample Volume Gate • Length, Depth, Pos Length:
• Velocity Scale • Sweep Speed • 2D: 140MB: up to 3 mins and up to 7,000 frames (depending
on B-image size and FPS); typical: about 1min./1000 images
Color Flow Mode (CFM, PD, TD, HD-Flow) (with curved array: 15cm depth, angle 81°, 22 FPS)
• Acoustic Output • PRF • M-Mode: 32MB: up to 20 min motion time (depending on
• Wall Motion Filter • Line density sweep speed and depth)
• Ensemble • Smooth (Rise and Fall) • Dop.– Mode: 32MB: up to 10 min motion time (depending on
• Frequency • Balance sweep speed)
• Line Filter • Quality Cine operation:
• Artifact Suppression • Manual: image by image
• Auto run: speed: 6 to 400% of real-time rate, play repeat
Post-Processing mode: forward–forward, forward-backward-forward
Read Zoom: 0.8x - 3.4x Zoom (with HD-Zoom functionality up to
22x Zoom ) Image/Volume Storage
B-Mode Image data stored as:
• 2D Gain • Dynamic Contrast • Raw Data file (proprietary format)
• Gray Map • Colorized B • DICOM file (Single- or Mulitframe)
• SRI II (Speckle Reduction Imaging) Volume file stored as
M-Mode • Raw Data file (proprietary format)
• Gray Map • Colorized M • Size: typically: 0.8 - 5MB
• Display Format • Sweep Speed (depending on probe and adjusted volume size)
PW Mode Compression
• Gray Map • Base Line Shift • 2D: JPEG, Lossless, high, mid, low
• Angle Correction • Colorized D • 3D/4D: Lossy and lossless compression available. Typical
• Scale (KHz, m/s, cm/s) • Trace compression rates are 50% with lossless compression, 15%
• Invert • Sweep Speed with lossy compression but maximum quality and 5% with
Color Flow Imaging Modes (CFM, PD, TD, HD-Flow) lossy compression and reduced quality (approximate values).
• Color Map • Display Threshold
• Scale (CFM and HD-Flow) • Baseline
• Display Mode (V, V-T, T, P, P-T) (CFM only)
Scanning Parameters
Image/Volume Storage (cont.) B-Mode
Review: Review of current Exam and archived data sets (Single B Acoustic Power 1-100%
Images and Cine Clips). View Format: Raw data, DICOM data. Scan Angle changed in 5º
Display Formats: 1x1, 2x2, 3x3 (probe dependent)
Reload: Frequency range 1-18 Mhz (Depending on the
• Reload of current/ archived data sets: 2D Raw Data (incl. probe, 3 steps high, mid, low)
Color Doppler, Spectral Doppler and M-Mode). 3D Raw Data
Frame rate >740 fps (depending on probe
(Single Volume incl. Calc. Cines). 4D Raw Data (Volume Cine)
and application)
Export as
GAIN range +15 to -15 dB
• Bitmap files: BMP, TIFF, JPEG
• Raw files: RAW (2D), VOL (Volume data), 4DV (RAW, VOL incl. Gray scale values 8 bit
Patient data) SRI 6 steps (1-6)
• Sequence of Bitmaps: BMP, AVI, MOV CRI 8 steps (1-8)
• DICOM Files: DCM, DICOM Files with DICOMDIR
CRI filter 4 steps: off, low, mid, high
• 3D Raw Data: conversion to Cartesian format possible
CE On/Off (Probe dependent)
AVI Codec: MPEG4, MS Video 1, FullFrames
FFC On/Off (Probe dependent)
Export to: DVD+ R(W), CD-R(W), Network, USB devices
Persistence filter 8 steps (pre)
Export Anonymous function: yes, available for following image
types: AVI, MOV, BMP, TIFF, JPEG Line filter 3 steps (pre) off,
low (12,5/75/12,5%),
Backup function to: DVD+ R(W) / CD-R(W), Network, USB devices
high (25/50/25%)
Repro function: Settings recall (e.g. Geometry, Gain, Colormap,
Line Density 3 steps (pre) low, norm, high
etc.) from a stored or reloaded picture
Reject 51 steps (pre) from 0 to 225
Exam History: direct access to images from previous exams;
direct access to Measure Reports images from previous exams; Enhance 6 steps (pre) 0, 1, 2, 3, 4, 5
Image compare window on screen to compare images from Gray maps 21 (18 basic maps and
previous exams with current exam image 3 User-defined maps)
Hard Drive Data Storage size: approximately 430 GB Tint maps 15
Dynamic 12 different dynamic curves
Connectivity C1 – C12
Ethernet network connection Display Modes B, XTD
WLAN network connection Screen Formats
2 USB Ports for hard disks/memory sticks • 2D Imaging: Single (B), Dual (B+B), Quad (B+B+B+B)
• XTD View: Single (XTD), Dual (B+XTD)
1 USB Port for FootSwitch/Printer
Working Modes M (conventional M-Mode),
DICOM support (option)
AMM (Anatomical M-Mode)
• Verify
• Print Frequency range 1-18 Mhz (Depending on the
• Store probe, 3 steps high, mid, low)
• Modality Work list M Acoustic Power 1-100%
• Structured Reporting M Gain ±15 dB range, 1 dB steps
• Storage Commitment
M sweep speeds
• MPPS (modality performed procedure step)
• 900 / 450 / 300 / 225 / 150 / 100 pixels/sec;
• Media Exchange
• 26.44 / 13.22 / 8.81 / 6.61 / 4.40 / 2.94 cm/s in relation
• Off network / mobile storage queue
to system monitor
• Query/Retrieve
Review (memory times) >60 s (32MB)
Signal processing M:
• Dynamic range: 1 to 12 • Reject: 0 to 255
• Enhance: 0 to 5 • Gray maps: 18
• Tint maps: 15
Display Modes
• M: 2D + M, 2D + M/CFM, 2D + M/HD-Flow, 2D + M/PD, 2D + M/TD
• AMM: 2D + AMM, 2D/CFM + AMM/CFM, 2D/HD- Flow + AMM/
HD-Flow, 2D/TD + AMM/TD
Scanning Parameters (cont.)
M-Mode
Screen Formats (window arrangement) PW sweep speeds:
• 2D + M and 2D + AMM: up/down (horizontal): three different sub • Simplex (26,44 / 13.22 / 8.81 / 6.61 / 4.40 / 2.94 cm/s)
formats 30/70, 50/50, 70/30% left/right (vertical): 50/50% • Duplex/Triplex (8.81 / 6.61 / 4.40 / 2.94 cm/s)
• 2D + AMM + AMM: left/rt-up/rt-down: 50/25/25% Review (memory times) >60 s (32MB)
Measurable flow velocities:
M-Color Flow Mode • PW: 1cm/s – 8m/s (a = 0°, 2.0 MHz, max. zero shift)
Acoustic MCFM Power 1-100% 1cm/s – 16m/s (a = 60°, 2.0 MHz, max. zero shift)
Frequency range 1-18 Mhz (Depending on the Signal processing:
probe, 3 steps high, mid, low) • Dynamic range: 15 steps (10 to 40)
MCFM Color Maps 8 maps • Gray maps: 18 basic curves and 3 User-defined (pre, post)
• Tint maps: 5
CFM Gain ±16 dB range, 1 dB steps
Scale display:
CFM Velocity Scale Range PRF: 150 Hz to 13 kHz • Vert.: kHz, cm/s, m/s (selectable)
Wall Motion Filter 8 – 3000 Hz • Hor.: 1s marker (big), ½s marker (small)
Ensemble (color shots per line) 8-16, step size 1 Screen Formats:
Gentle color filter • 2D/D: up/down (horizontal): three different sub formats 40/60,
Smooth filter: 50/50, 60/40% left/right (vertical): 50/50%. D: pencil probes only
• Rise: 12 steps • Fall: 12 steps Display Formats:
CFM Spectrum Inversion • 2D/D (duplex update, simultaneous); 2D+CFM/D, 2D+HD-Flow/D,
2D+PD/D, 2D+TD/D (triplex update, PW). 2D+CFM/PW,
CFM Baseline Shift 17 steps 2D+PD/PW, 2D+HDFlow/PW, 2D+TD/PW, (triplex simultaneous,
Pre-settable and independently adjustable B-, M and MCFM Gain PW only)
CFM Threshold 1 – 255 steps Audio-Modes Stereo (both directions
Balance 25 – 225, step size 5 separately in both channels)
Artifact suppression On/Off Audio Volume Adjustable, control digipots
Color Display Mode:
• V (Velocity) Color Doppler Mode
• V-T (Velocity + Turbulence) Screen Formats 2D+CFM (Single, Dual, Quad)
• V-P (Velocity + Power) Frequency range 1-16 Mhz (Depending on the
• T (Turbulence) probe, 3 steps high, mid, low)
• P-T (Power + Turbulence)
Display Modes:
Real-time Triplex Mode: • Simultaneous dual mode: 2D/2D+CFM
• B + M + MCFM in any depth • Triplex mode: 2D+CFM/PW, 2D/M+MCFM
• Volume Mode: 3D+CFM
Spectral Doppler Mode (PW)
Color coding:
Operating Modes • Steps: 65536 color steps
• PW (Pulsed Wave Doppler, Single Gate) Display modes
Frequency range 1.75-16 Mhz (Depending on the • V-T (velocity + turbulence) • V (velocity)
probe, 3 steps high, mid, low) • V-P (velocity + power) • T (turbulence)
Pulse Repetition Frequency (PRF) • P-T (power + turbulence)
• PW-Doppler: 0.9 ...22.0 kHz Depth range:
Sample Volume (Doppler Gate): • Axial: 0 to B scan range • Lateral: 0 to B scan range
• Length: 0.7, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15 mm Baseline shift 17 steps (independent from
• Position: 5 mm to B-scan end spectral Doppler)
• Angle correction: - 85° ... 0° ... + 85° Inversion of color direction Yes
Power control range 1 - 100% Wall Motion Filter 8 steps (low1, low2, mid1, mid2,
Gain range PW +15 to -25 dB high1, high2, max1, max2)
WMF (wall motion filter) PW: 30...500 Hz Smoothing Filter
Zero line shift ±PRF/2, ±8 steps • 12 steps rise time • 12 steps fall time
Spectrum Analyzer FFT (Fast Fourier Gain control +15 dB to -15 dB, 0.2 dB step
Transformation), max. 256 Line Density (color line density) 10 steps
channels, 255-256 amplitude Ensemble (color shots per line)
levels • CFM: 7 to 31 • MCFM: 8 to 16
Flow Resolution 4 steps (low, mid1, mid2, high)
Scanning Parameters (cont.)
Color Doppler Mode (cont.)
Pulse repetition frequency Wall Motion Filter 8 steps (low1, low2, mid1, mid2,
• CFM: 150 Hz to 20.5 kHz • MCFM: 150 Hz to 20.5 kHz high1, high2, max1, max2)
Color Map 8 different color codes for Smoothing Filter
each probe • 12 steps rise edge • 12 steps fall edge
Balance From 25 to 225 Gain Control +15 dB to -15 dB, 0.2 dB steps
Max. meas. velocity 4.23 m/sec HD-Flow Ensemble 7 to 31
Min. meas. velocity 0.3 cm/sec HD-Flow Line Density 10 steps
Scale kHz, cm/s, m/s Pulse Repetition Frequency 150 Hz to 20.5 KHz
Automatic moving tissue Yes HD-Flow Map 8 different color codes for
suppression each probe)
Flow Resolution 4 steps (low, mid1, mid2, high)
Power Doppler Mode (PD) Balance From 25 to 225
Screen Formats 2D+PD (Single, Dual, Quad) Artefact suppression Yes
Frequency range 1-16 Mhz (Depending on the
probe, 3 steps high, mid, low) Tissue Doppler Mode (TD)
Display Modes: Screen Formats 2D+TD (Single, Dual, Quad)
• Simultaneous dual mode: 2D/2D+PD
• Triplex mode: 2D+PD/PW • Volume Mode: 3D+PD Display Modes
• Simultaneous dual mode: 2D/2D + TD
PD coding 256 color steps • Triplex mode: 2D + TD/PW, 2D/M + MTD
PD window size TD coding steps 65536 color steps
• Lateral: maximum to minimum B mode scan angle
• Axial: B-scan range Depth range:
• Axial: 0 to B-scan range • Lateral: 0 to B-scan-range
Display mode P (power)
Zero line shift 17 steps
Wall motion Filter 8 steps (low1, low2, mid1, mid2,
high1, high2, max1, max2) Inversion of color direction Yes
Smoothing Filter Smoothing Filter:
• Rise edge: 12 steps • Fall edge: 12 steps • 12 steps rise time • 12 steps fall time
Gain control +15 dB to -15 dB, 0.2 dB steps Gain control +15 dB to -15 dB, 0.2 dB steps
PD Ensemble 7 to 31 Line Density (color line density) 10 steps
PD Line Density 10 steps Ensemble (color shots per line) 3 to 31
Pulse repetition frequency 150 Hz to 20.5 kHz Flow Resolution 4 steps (low, mid1, mid2, high)
PD Map 8 different color codes for each Pulse repetition frequency 150 Hz to 20.5 kHz
probe TD Map 4 different color codes for
Flow Resolution 4 steps (low, mid1, mid2, high) each probe
Balance From 25 to 225 in 41 steps Frequency range:
• 1 to 16 MHz depending on the probe
Artefact suppression Yes • Adjustable in 3 steps (low, mid, high)
Balance From 25 to 225
HD-Flow
Max. meas. velocity 4.23 m/sec
Screen Formats 2D+HDF (Single, Dual, Quad)
Min. meas. velocity 0.3 cm/sec
Frequency range 1-16 Mhz (Depending on the
Display Mode V (velocity)
probe, 3 steps high, mid, low)
Scale kHz, cm/s, m/s
Display Modes:
• Simultaneous dual mode: 2D/2D+HDF
• Triplex mode: 2D+HDF/PW; 2D/M+MHDF Volume Scan Module
• Volume Mode: 3D+HDF Vol. scan size: max. 64 MB for gray volumes; max. 90 MB for color
HD-Flow Coding Steps 256 color steps volumes; The required memory space depends on scan param-
HD-Flow window size: eters (VOL-box size and quality (low, mid1, mid2, high1, high2,
• Lateral: maximal to minimal B mode scan angle max). Typical: 0.8-5 MB
• Axial: B-scan range Lines/2D-image: max. 1024 (typ. 80 to 350)
Display mode P (power) 2D-images/volume: Up to 4096 (Acquisition Mode dependent)
Volume Scan Module (cont.) Scanning Features
VOL-Frames/sec.: max. 40; The frame rate depends on scan Coded Excitation (CE)
parameters: VOL-Box size, quality and probe. Availability depends on probe
4D Volume Cine: up to 128 volumes
Display of sectional plane images: synchronous with control Coded Harmonic Imaging (CHI)
setting, arbitrary movement in volume, monitored position in Harmonic Imaging
volume.
Available on all probes
Rotation: 360°, 1° or 3° increments (X-, Y- and Z-axis)
Magnification: adjustable from 0.3 to a factor of 4.00 Focus Frequency Composite - (FFC)
Acquisition Modes: Availability depends on probe
3D Static:
• 3D (2D incl. CRI) Compound Resolution Imaging (CRI)
• 3D/PD (incl. CRI)
• 3D/CFM (incl. CRI) Available on all probes except the 3Sc
• 3D/HD-FLow incl. CRI)
• 4D Real Time Speckle Reduction Imaging
• 4D Biopsy Available on all probes
• VCI-SingleView
• SingleView Virtual Convex
Visualization Modes: Available on all linear probes
• 3D Rendering (diverse surface and intensity projection modes)
• SonoRenderStart
Wide Sector
• Sectional Planes
• Multiplanar Available on the following probes:
• SingleView (optional), actual – and projected view (Option) • E8C-RS
• Niche • RIC5-9W-RS
• SonoVCADlabor
• Volume Analyses Measurements Tool
• SonoAVCfollicle (Sono Automated Volume Count)
Generic Measurements
• Advanced VCI (Volume Contrast Imaging)
Distance
Render Modes:
• Distance (Point to Point) • Distance (Line to Line)
• Surface texture
• 2D Trace (Trace Length) • 2D Trace (Point Length)
• Surface Smooth
• Stenosis (% Dist)
• Surface Skin and Smooth
• Max-, min- and X-ray (average intensity projection) Area/Circumference
• Gradient • Ellipse • Trace (Line)
• Inversion • Trace (Point) • Stenosis (% Area)
• Glass Body • Area (2 Dist.)
• Mix Mode of two Render Modes Volume: following Methods:
Display graphics: • 1 Distance • 1 Ellipse
• Rotation axis, center point; • 1 Dist. + Ellipse • 3 Distance
• ROI box, 3D Frame; • Multiplane - Planimetric Volume (3D only)
• Optional display of onscreen controls (rotation, translation) Angle:
Gray maps: Slices: 21 (18 basic curves and 3 User-defined (pre, • Angle (3 Point) • Angle (2 Line)
post) 3D Image: one general map adjustable with bright (1-100) & M-Mode
contrast (1-100) • Distance (Point to Point) • Time
Tint maps: Slices: 15; 3D Image: 15 • Slope • HR
• Stenosis (% Dist)
Depth render maps: 3
Frequency range: 1-18Mhz (Depending on the probe, 3 steps
high, mid, low)
Measurements Tool
Generic Measurements
Doppler Mode Fetal Cranium
• Auto & Manual Trace: NT Method: SonoNT
- PS (Peak Systole) - ED (End Diastole) AFI
- MD (Min. Diastole) - PS/ED (Ratio)
Uterus
- PI (Pulsatility Index) - RI (Resistance Index)
• TAmax (Time avg. max. Velocity) Ovary
• TAmean(Time avg. mean Velocity) Fetal Doppler measurements (Ductus Art., Ductus Ven.,Ao,
• VTI (Velocity Time Integral) Carotid, MCA, Celiac Artery, Superior Mesenteric Artery, Umbilical
• Ductus venosus: S, D, a, PI, PLI, PVIV Art., Umbilical Vein, Uterine Art., Umbilical Vein, FHR, Atrial FHR)
• Heart Rate Gestational Age Calculation
• Single Measurements: Gestational Growth Calculation
- Velocity - Acceleration
- RI - PI Fractional limb Volume
- PS/ED - Time Fetal Weight (FW) Estimation
- HR Fetal Trend Graph
Multi-Gestational Calculation & Fetal Compare
Calculations Calculation and Ratios
Abdomen Calculations Fetal Qualitative Description (Anatomical survey)
Liver Fetal Environmental Description (Biophysical profile)
Gallbladder Summary Reports
Pancreas
Spleen Obstetrics Fetal Echo
Kidney (right/left) 4-Chamber-view
Renal Artery (right/left) Thorax
Aorta (Proximal, Mid, Distal) Outflow Tract, Aortic arch
Portal Vein Venous
Vessel Tricuspid valve
Bladder Volume Mitral Valve
Summary Reports Aortic Valve
Main Pulmonary Artery
Small Part Default Calculations Pulmonary Valve
Thyroid (right/left) Aorta, Ductus Art.
Testicle (right/left) Umbilical Vein, Ductus Ven.
Vessel FHR
Summary Reports Atrial FHR
LVOT
Small Part Breast Calculations
RVOT
Lesion 1-5 (right/left) Pulmonary Veins
Summary Reports Carotid
Summary Reports
Obstetrics Calculations
Fetal Biometry Obstetrics Z-Scores
Early Gestation Calculation of Z-Scores for:
Fetal Long Bones • Long Axis • Aortic Arch
NBL (Nasal Bone Length) • Short Axis • Obl. Short axis
• 4 Chambers • Summary Reports
Cardiology Urology
2D Mode: Bladder
• LV Simpson (Single & Bi-Plane) Prostate
• Volume (Area Length)
Left/Right Testicle
• LV-Mass (Epi & Endo Area, LV Length)
• LV (RVD, IVS, LVD, LVPW) Left/Right Kidney
• LVOT Diameter Left/Right Renal Artery
• RVOT Diameter Left/Right Dorsal Penile Artery
• MV (Dist A, Dist B, Area)
Vessel
• TV (Diameter)
• AV/LA (Aortic Valve/Left Atrium) Summary Reports incl. PSAD, PPSA(1), PPSA(2) calculation
• PV (Diameter)
M-Mode: Vascular
• LV (IVS, LVD, LVPW, RVD) Left/Right CCA (Common Carotid Artery)
• AV/LA (Ao Root Diam, LA Diam, AV Cusp Sep., Ao Root Ampl) Left/Right ICA (Internal Carotid Artery)
• MV (D-E, E-F Slope, A-C Interval, EPSS)
Left/Right ECA (External Carotid Artery)
• HR (Heart Rate), Atrial HR
Left/Right Vertebral Artery
D-Mode:
• MV (Mitral Valve) Left/Right Subclav.
• AV (Aortic Valve), TV (Tricuspid Valve) Left/Right Bulb
• PV (Pulmonary Valve) Vessels
• LVOT & RVOT Doppler (Left & Right Ventricle Outflow Tract)
Summary Reports
• Pulmonic Veins
• PAP (Pulmonary Artery Pressure measurement)
Gynecology
• HR (Heart Rate)
C-Mode: Uterus
• PISA Right/Left Ovary
• Tei-Index Right/Left Follicle
Others: Fibroid
• Diast. Vol (Bi)
Endometrial thickness (Dist, Double Dist.)
• Syst.Vol.(Bi)
• Stroke Volume Cervix Length
• Volume Flow Left/Right Ovarian Artery
• Cardiac Output Left/Right Uterine Artery
• Ejection Fraction Vessels
• Fractional Fract.
• Shortening Pelvic Floor
• Myocardial Thickness FHR
• LA/Ao Ratio Summary Reports
• E/A Peak
• Peak Gradient Acceleration Pediatrics
• Mean Gradient
• Mean Gradient Acceleration Left/Right Hip Joint
• VTI Pericallosal Artery
• TVA Summary Report
• PG
• PHT Neurology
• MVA
Left/Right ACA (Anterior Cerebral Artery)
• AVA
• ERO Left/Right MCA (Middle Cerebral Artery)
• CVP (Cardio Vascular Profile) Score Left/Right PCA (Posterior Cerebral Artery)
Summary Reports Basilar Artery
A-Com. A (Anterior Com. Artery)
P-Com. A (Posterior Com. Artery)
Left/Right CCA (Common Carotid Artery)
Left/Right ICA (Internal Carotid Artery)
Left/Right Vertebral Artery • CRL: ASUM, Hadlock, Hansmann, JSUM, Persson, OSAKA,
Vessels Robinson, Shinozuka, Tokyo
• DV PI, DV PLI, DV PVIV, DV S/a: Baschat
Summary Reports
• EFW: Brenner, Doubilet, Hadlock, Hansmann, Hansmann(86),
Hobbins/Persutte, JSUM 2001, Persson, Osaka, , Shinozuka,
OB Tables Tokyo, Williams, Yarkoni (Twins) , Ananth (Twins, Monochorionic),
Age Tables: Ananth (Twins Dichorionic)
• AC: ASUM, CFEF, Hadlock_82, Hadlock_84, Hansmann, • FL: ASUM, CFEF, Chitty, Chitty, Hadlock, Hansmann, Jacot-
Hobbins, Jeanty, JSUM, Kurmanavicius, Merz, Nicolaides, Uillarmod, Jeanty, JSUM, Kurmanavicius, Lessoway, Persson,
Shinozuka, Siriraj, Tokyo Merz, Nicolaides, O´Brien, OSAKA, Shinozuka, Siriraj, Tokyo,
• AD: Persson Verburg, WARDA
• APAD: Merz • FTA: OSAKA
• APTD: Hansmann • FIB: Chitty, Jeanty, Siriraj
• APTDxTTD: Shinozuka, Tokyo • Foot: Chitty
• BOD: Jeanty • GS: Hellman, Rempen, Tokyo
• BPD: ASUM, ASUM (old), Campbell, CFEF, Chitty (outer-outer) • HC: ASUM, CFEF, Chitty, Hadlock, Hansmann, Jacot-Uillarmod,
(outer-inner), Chitty, Hadlock_82, Hadlock_84, Hansmann, Jeanty, Kurmanavicius, Lessoway, Merz, Nicolaides, Siriraj,
Hobbins, Jeanty, Johnsen, JSUM, Kurmanavicius, Kurtz, Verburg
Persson, Merz, Nicolaides, OSAKA, Rempen, Sabbagha, • HL: ASUM, Chitty, Jeanty, Merz, OSAKA, Siriraj
Shinozuka, Siriraj, Tokyo, Verburg (outer-outer • LV: Tokyo
• CLAV: YARKONI • MCA PI, RI: JSUM, Bahlman
• CRL: ASUM, ASUM(old), DAYA, Hadlock, Hansmann, JSUM, • MCA PV: Mari
Persson, Nelson, OSAKA, Rempen, Robinson, Shinozuka, Tokyo, • MAD: EIK-NES, Kurmanavicius
Verburg • MV E/A: HARADA
• EFW: Hadlock, JSUM 2001, Osaka, Shinozuka, Tokyo • NBL: BUNDUKI, SONEK
• FL: ASUM, ASUM_OLD, CFEF, Chitty, Hadlock_82, Hadlock_84, • OFD: ASUM, Chitty, Hansmann, Jeanty, Kurmanavicius,
Hansmann, Hobbins, Hohler, Jeanty, JSUM, Kurmanavicius, Merz, Nicolaides
Persson, Merz, Nicolaides, O´Brien, OSAKA, Shinozuka, Siriraj, • MainPA Vmax: Rizzo
Tokyo, WARDA • RAD: Chitty, Jeanty, Merz, Siriraj
• FTA: OSAKA • TAD: CFEF, JACOT-GUILLARMOD, Merz,
• FIB: Jeanty • TCD: Goldstein, HILL, JACOT-GUILLARMOD, Nicolaides, Verburg
• GS: Hansmann, Hellman, Holländer, Rempen, Tokyo • TIB: Chitty, Jeanty, Merz, Siriraj
• HC: ASUM, CFEF, Chitty, Hadlock_82, Hadlock_84, Hansmann, • TTD: Hansmann
Jeanty, Johnsen, Kurmanavicius, Merz, Nicolaides, Siriraj • TV E/A: HARADA
• HL: ASUM, Hobbins, Jeanty, Merz, OSAKA • ULNA: Chitty, Jeanty, Merz, Siriraj
• LV: Tokyo • UmbArt PI: JSUM, Merz
• MAD: EIK-NES, Kurmanavicius • UmbArt RI: JSUM, Merz, Kurmanavicius
• OFD: ASUM, Chitty, Hansmann, Jeanty, Kurmanavicius, Merz, • Fractional Limb Avol/Tvol: Lee
Nicolaides Fetal weight Extimation (EFW)
• RAD: Jeanty, Merz • Campbell (AC)
• TIB: Jeanty, Merz • Hadlock (AC, BPD)
• TAD: CFEF, Merz, Chitty, Goldstein, HILL, Hobbins, Nicolaides, • Hadlock 1 (AC, FL)
Hansmann • EFW
• ULNA: Jeanty, Merz • Hadlock 2 (BPD, AC, FL)
Growth Tables: • Hadlock 3 (HC, AC, FL)
• AC: ASUM, CFEF, Chitty, Hadlock, Hansmann, Jacot-Uillarmod, • Hadlock 4 (BPD, HC,AC, FL)
Jeanty, JSUM, Kurmanavicius, Lessoway, Merz, Nicolaides, • Hansmann (BPD, TTD)
Shinozuka, Siriraj, Tokyo, Verburg • Merz (AC, BPD)
• AD: Persson • Osaka (BPD, FTA, FL)
• AFI: Moore • Persson (BPD, MAD, FL)
• Aorta Vmax: Rizzo • Persson 2
• APTDxTTD: Shinozuka, Tokyo • Schild (HC, AC, FL)
• BOD: Jeanty • Shepard (AC, BPD)
• BPD: ASUM, Campbell, CFEF, Chitty, Hadlock, Hansmann, Jacot- • Shinozuka 1 (BPD, APTD, TTD, FL)
Uillarmod, Jeanty, JSUM, Kurmanavicius, Lessoway, Persson, • Shinozuka 2 (BPD, FL, AC)
Merz, Nicolaides, OSAKA, Sabbagha, Shinozuka, Siriraj, Tokyo, • Shinozuka 3 (BPD, APTD, TTD, LV)
Verburg • Tokyo (BPD, APTD, TTD, FL)
• CLAV: YARKONI
• CM: Nicolaides
Fetal ratios RIC5-9W-RS
CI (BPD/OFD) (Hadlock) Applications Obstetrics, Gynecology,
FL/AC (Hadlock) Urology
FL/BPD (Hohler) Band Width (-20 dB) 4 – 9 MHz
FL/HC (Hadlock) Number of Elements 192
HC/AC (Campbell) Convex Radius 11.6 mm
Va/Hem (Nicolaides) Volume Sweep Radius 11.6 mm
Va/Hem (Hansmann) FOV 146° (B), 146° x 120°
(Volume scan)
Vp/Hem (Nicolaides)
Wide 179 ° (B), 179° x 120°
(Volume scan)
Probes
Depth Max 16 cm
RAB4-8-RS
Foot Print 22.4 x 22.6mm
Applications Abdomen, Obstetrics,
Center Frequency 6.6 MHz
Gynecology, Urology, Pediatric
Doppler Tx. Frequency 6.25, 5.56, 5.00 MHz
Maximum Band Width (-20 dB) 2 – 8 MHz
Harm. Tx. Frequency 4.17, 4.17, 3.70 MHz
Number of Elements 192
Biopsy Guide Available PEC 63, Single-Angle, Reusable;
Convex Radius 46.0 mm
disposable biopsy guide.
Volume Sweep Radius 22.6 mm
FOV 70° (B), 85° x 70° (Volume scan) 4C-RS
Depth Max 26 cm Applications Abdominal, Obstetrics,
Foot Print 63.6 x 37.8 mm Gynecology
Center Frequency 4.4 MHz Maximum Band Width (-20 dB) 2 – 5 MHz
Doppler Tx. Frequency. 4.00, 3.45, 3.03 MHz Number of Elements 128
Harm. Tx. Frequency 3.03, 2.78, 2.56 MHz Convex Radius 60.0 mm
Biopsy Guide Available Volume Sweep Radius n/a
• PEC 74, Single-Angle, Reusable FOV 58°
• PEC 78, single angle, disposal with reusable bracket
Depth Max 30 cm
RAB2-5-RS Center frequency 3.1 MHz
Doppler Tx. Frequency 3.23, 2.70, 2.27 MHz
Applications Abdomen, Obstetrics,
Gynecology Harm. Tx. Frequency 2.38, 2.27, 2.08 MHz
Maximum Band Width (-20 dB) 1 – 5 MHz Biopsy Guide Available Multi-Angle, disposable
with reusable bracket
Number of Elements 192
Convex Radius 46.0 mm
AB2-7-RS
Volume Sweep Radius 22.6 mm
Applications Abdomen, Obstetrics,
FOV 70° (B), 85° x 70° (Volume scan) Gynecology, Urology, Pediatrics
Depth Max 30 cm Maximum Band Width (-20 dB) 2 – 8 MHz
Foot Print 63.6 x 38.9 mm Number of Elements 192
Center Frequency 3.2 MHz Convex Radius 40.0 mm
Doppler Tx. Frequency 3.22, 2.34, 2.32 MHz Volume Sweep Radius n/a
Harm. Tx. Frequency 2.13, 2.0 MHz FOV 80°
Biopsy Guide Available Foot Print 58.9 x 23.4 mm
• PEC 74, Single-Angle, Reusable
Depth Max 28 cm
• PEC 78, single angle, disposal with reusable bracket
Center Frequency 4.3 MHz
Doppler Tx. Frequency 4.17, 3.33, 2.63 MHz
Harm. Tx. Frequency 2.78, 2.33 MHz
Biopsy Guide Available PEC71, PEC83, Single-Angle,
Reusable
E8C-RS 9L-RS
Applications Obstetrics, Gynecology, Applications Abdominal, Small Parts,
Urology Obstetrics, Peripheral Vascular,
Maximum Band Width (-20 dB) 4 - 10 MHz Pediatrics, MSK
Number of Elements 128 Maximum Band Width (-20 dB) 3 – 8 MHz
Convex radius 10.7 mm Number of Elements 192
Volume Sweep Radius n/a Volume Sweep Radius n/a
FOV 123° FOV (Width) 37 mm
Wide 160° Depth Max 14 cm
Depth Max 16 cm Center Frequency 5.3 MHz
Center Frequency 6.5 MHz Doppler Tx. Frequency 7.14, 6.25, 5.26 MHz
Doppler Tx. Frequency. 6.67, 5.88, 4.76 MHz Harm. Tx. Frequency 5.26, 4.55, 3.70 MHz
Harm. Tx. Frequency 4.55, 4.17, 3.70 MHz Biopsy Guide Available Multi-Angle, Reusable
Biopsy Guide Available Single-Angle, Reusable
and Disposable 3Sc-RS
Applications Abdominal, Cardiology,
8C-RS Obstetrics, Pediatrics
Applications Abdominal, Small Parts, Maximum Band Width (-20 dB) 1 - 4 MHz
Cardiology, Peripheral Vascular, Number of Elements 64
Pediatrics Volume Sweep Radius n/a
Maximum Band Width (-20 dB) 4 – 10 MHz FOV (Width) 90°
Number of Elements 128 Depth Max 24 cm
Convex radius 10.7 mm Center Frequency 2.8 MHz
Volume Sweep Radius n/a Doppler Tx. Frequency 2.5, 2.17, 1.85 MHz
FOV 123° Harm. Tx. Frequency 2.0, 1.92 MHz
Depth Max 16 cm Biopsy Guide Available Multi-Angle, Reusable
Center Frequency 6.5 MHz
Doppler Tx. Frequency. 6.67, 5.88, 4.76 MHz
Harm. Tx. Frequency 4.55, 4.17, 3.70 MHz
Biopsy Guide Available Single-Angle, Reusable
and Disposable

12L-RS
Applications Small Parts, Obstetrics,
Peripheral Vascular, Pediatrics,
MSK
Maximum Band Width (-20 dB) 4 – 12 MHz
Number of Elements 192
Volume Sweep Radius n/a
FOV (Width) 37 mm
Depth Max 8 cm
Center Frequency 7.7 MHz
Doppler Tx. Frequency 7.14, 6.25, 5.26 MHz
Harm. Tx. Frequency 5.56, 5.00, 4.55 MHz
Biopsy Guide Available Multi-Angle, disposable
with reusable bracket
External Inputs and Outputs
Connectivity:
HDMI Out
Network (RJ45)
External Audio Out
USB (2x in front, 1x in rear)
AC Power Input
Probe connector

Safety Conformance
The Voluson S6 is:
Listed to UL 60601-1 by a Nationally Recognized Test Lab
Certified to CSA 22.2, 60601.1 by an SCC accredited Test Lab
CB-Test report by National Certification Body
CE Marked to Council Directive 93/42/EEC on Medical
Devices
Conforms to the following standards for safety:
IEC 60601-1 Electrical medical equipment
IEC 60601-1-1 Electrical medical equipment
IEC 60601-1-2 Electromagnetic compatibility
IEC 60601-1-4 Programmable medical systems
IEC 61157 Declaration of acoustic output
ISO 10993 Biological evaluation of medical devices
NEMA UD3, UD2 Acoustic output display (MI, TIS, TIB, TIC)
IEC 60601-2-37 Particular requirements for the safety of
ultrasonic medical diagnostic and monitoring equipment
IEC60601-1-6 Usability

Please contact your GE Sales Representative


for information about availability in your area.

GE Healthcare © 2012 General Electric Company – All rights reserved.

9900 Innovation Drive General Electric Company reserves the right to make
changes in specifications and features shown herein,
Wauwatosa, WI 53226 or discontinue the product described at any time without
notice or obligation. Contact your GE Representative
U.S.A. for the most current information.

GE, GE Monogram, Voluson, CrossXBeam, HD-Flow,


www.gehealthcare.com SonoVCAD and SonoAVC are trademarks of the General
Electric Company.

DICOM is a registered mark of the National Electrical


Manufacturers Association

GE Medical Systems Ultrasound & Primary Care


Diagnostics, LLC, a General Electric company, doing
business as GE Healthcare.

* Trademark of General Electric Company.


DOC1174871

You might also like