Indirect Thermal Desorption System
n The Indirect Thermal Desorber (ITD) is for decontamination of
equipment such as capacitors, transformer cores & absorbents.
n After treatment in ITD, the waste is “Free from PCB”. The copper and
steel can be recycled. Other materials can be disposed of as inert
waste following treatment through the ITD.
R+x-1 is reactive free-radical from the biphenyl structure and combines with H+,
formed by the reaction of sodium with water or donated by the mineral oil, to
form a neutral RH molecule. If RH contains additional chlorine, it is again
attacked by sodium and the process is repeated until all chlorine atoms have
been replaced by hydrogen atoms. The PCB molecule is converted to a biphenyl
molecule and all chlorine atoms combine with sodium to form sodium chloride .
10
Process Flow – PCB Decontamination Facility
Transformer
with oil & PCB
Regenerated oil
for Recycle
11
Non Combustion PCB destruction Process
n The advantages of design are:
u Better emissions control
u The batch operation avoids cross contamination of cleaned oil.
u The Sodium based reaction as most PCB destruction reaction, it is
exothermic reaction, generates enough heat increase temperature of
reaction mixture well over the mineral oil flash point.
n The main process mode of operation is to treat contaminated mineral
oil that contains chlorine content < 4000 ppm.
Other pre-treatment
Parameter PCB destruction unit
devices
Temperature 80 - 1450C 60-800C
n Buffer tank
n Settling tank
n Quench water tank
n Sodium dispersion measuring tank
n Mineral oil tanks
n PCB tank
n Reclaimed oil tank
n Regenerated clean oil tank
n Oil washing chamber
n Electrical equipment dismantling tank
n Mixing Vessels/Rectors
u Reactor Continued.
u Dispersed sodium manufacturing tank
u Holding tank
n Pumps
u Quench water pump
u Product pump
u Discharge pump
u Mineral oil
u PCB oil pump
u Clean / reclaimed oil pump
u Cooling pumps
u Glycol pump
n Heat Exchangers:
u Gas Condenser – 54 KW
Continued
u Mineral oil Heat Exchanger – 277 KW
n General Utilities:
u Chiller unit – 100 KW (Water/Glycol) 75 kg/hr.
u PCB oil Degasifier / dehydrator - 4 m3/hr.
Solid waste
Description Quantity/Quality Method of collection method of disposal
Waste gases
Waste gases Case Flow per day Flow /Project Temperature
Gas effluents are Nitrogen is used to 16 m3kg/day 3840 m3 tonne 25-30oC
mainly Nitrogen purge Hydrogen, of nitrogen per year
and Hydrogen produced by Sodium
neutralization reaction
with water
The exhaust gas stream, mainly Nitrogen and Hydrogen coming from the reaction
vessel passes through an air pollution control system before being discharged to
the atmosphere.
18
Utilities – Part A & Part B
Utilities Demand or pressure Consumption
Electricity 3 ph., 415 V, 50Hz 90 KW-hr /T of PCB waste
165 KW/Hr for Plascon
25 KW/Hr for ITD
Water P = 250 kPa (g) • 60 KLD
1 Domestic 2 1.5
2 Industrial /Process 0 6
3 Boiler 2 0
4 Cooling Tower 20 17
Total 30 30
20
Environmental Pollution Control Cont…
The cleaning / washing and cooling blow down water shall be sent to existing
ETP network of BSP for further treatment and disposal as per stipulated standards.
High TDS effluents from Plascon unit will be evaporated in MEE. Condensate will
be used as cooling tower water make up.