You are on page 1of 2

SCHEDULE OF LOADS

TOTAL VOLT
CKT NO. LOAD DESCRIPTION VOLTS AMP/CKT PROTECTION
AMPS
1 8 LIGHTING OUTLET 230 400 1.74 20AT
2 8 LIGHTING OUTLET 230 400 1.74 20AT
3 8 LIGHTING OUTLET 230 400 1.74 20AT
4 8 LIGHTING OUTLET 230 400 1.74 20AT
5 6 CONVINIENCE OUTLET 230 1080 4.70 30AT

6 230 1866 8.11 30AT


ACU (2 HP)

7 230 1866 8.11 30AT


ACU (2 HP)
8 SPARE
9 SPARE
TOTAL CONNECTED LOADS 6412 27.88

I= ((6412 + 373)/230)(0.80 DF)


I= 23.6A
USE= 2-8.0 MM2 THHN WIRE + 1-5.5MM2 THHN WIRE IN 25MMᴓ EMT PIPE
OF LOADS
SIZE OF WIRE CONDUIT

2-3.5 MM2 THHN WIRE 20MMᴓ

2-3.5 MM2 THHN WIRE 20MMᴓ

2-3.5 MM2 THHN WIRE 20MMᴓ

2-3.5 MM2 THHN WIRE 20MMᴓ

2-5.5 MM2 THHN WIRE + 1-3.5 MM2 THHN WIRE 25MMᴓ

2-5.5 MM2 THHN WIRE + 1-3.5 MM2 THWN WIRE 25MMᴓ

2-5.5 MM2 THHN WIRE + 1-3.5 MM2 THWN WIRE 25MMᴓ