You are on page 1of 2

PENGADAAN PEMBANGUNAN

COAL SHELTER PLTU INDRAMAYU


Date : 29 JULI 2019
Report No. : 04/QC-WIR/IV/19
Page : 1 of 2

WELDING INSPECTION REPORT


Customer : PT PLN Part Name : Tali Angin
Unit Name : Coal Shelter Part Number : TL L 61
Description : Tali Angin line 61 Drawing Number : T3131-C-01-11-03-19
FIT UP WELDING ROOT VIS INSP NDT
NO DESCRIPTION JOIN NO
DATE DATE FILL/CAP ACC REJ ACC/REJ REPORT NO.
1 Tali Angin 1 1A 1, 2 26/6/2019 28/6/2019 W 06 √
1B 1, 2 26/6/2019 28/6/2019 W06 √
1C 1, 2 26/6/2019 28/6/2019 W 06 √
2 Tali Angin 2 2A 1, 2 26/6/2019 28/6/2019 W 06 √
2B 1, 2 26/6/2019 28/6/2019 W 06 √
2C 1, 2 26/6/2019 28/6/2019 W 06 √
3 Tali Angin 3 3A 1, 2 26/6/2019 28/6/2019 W 06 √
3B 1, 2 26/6/2019 28/6/2019 W 06 √ ACC
3C 1, 2 26/6/2019 28/6/2019 W 06 √
4 Tali Angin 4 4A 1, 2 26/6/2019 28/6/2019 W 06 √
4B 1, 2 26/6/2019 28/6/2019 W 06 √
4C 1, 2 26/6/2019 28/6/2019 W 06 √
5 Tali Angin 5 5A 1, 2 26/6/2019 28/6/2019 W 06 √
5B 1, 2 26/6/2019 28/6/2019 W 06 √
5C 1, 2 26/6/2019 28/6/2019 W 06 √
6 Tali Angin 6 6A 1, 2 26/6/2019 28/6/2019 W 06 √
6B 1, 2 26/6/2019 28/6/2019 W 06 √
6C 1, 2 26/6/2019 28/6/2019 W 06 √
7 Tali Angin 7 7A 1, 2 26/6/2019 28/6/2019 W 06 √ ACC
7B 1, 2 26/6/2019 28/6/2019 W 06 √
7C 1, 2 26/6/2019 28/6/2019 W 06 √
8 Tali Angin 8 8A 1, 2 26/6/2019 28/6/2019 W 06 √
8B 1, 2 26/6/2019 28/6/2019 W 06 √
8C 1, 2 26/6/2019 28/6/2019 W 06 √
9 Tali Angin 9 9A 1, 2 26/6/2019 28/6/2019 W 06 √
9B 1, 2 26/6/2019 28/6/2019 W 06 √
9C 1, 2 26/6/2019 28/6/2019 W 06 √
10 Tali Angin 10 10A 1, 2 27/6/2019 29/6/2019 W 06 √
10B 1, 2 27/6/2019 29/6/2019 W 06 √
10C 1, 2 27/6/2019 29/6/2019 W 06 √
11 Tali Angin 11 11A 1, 2 27/6/2019 29/6/2019 W 06 √ ACC
11B 1, 2 27/6/2019 29/6/2019 W 06 √
11C 1, 2 27/6/2019 29/6/2019 W 06 √
12 Tali Angin 12 12A 1, 2 27/6/2019 29/6/2019 W 06 √
12B 1, 2 27/6/2019 29/6/2019 W 06 √
12C 1, 2 27/6/2019 29/6/2019 W 06 √
13 Tali Angin 13 13A 1, 2 27/6/2019 29/6/2019 W 06 √
13B 1, 2 27/6/2019 29/6/2019 W 06 √
13C 1, 2 27/6/2019 29/6/2019 W 06 √

Notes :

Inspected By: Reviewed/Witnessed By: Reviewed/Witnessed By:


PT. Waduk Tirta Asih PT Truba Jaya Engineering PT PLN Enjiniring

Ilhamdi Aef Sofyan Ferry


QA/QC Inspector QA/QC Inspector QA/QC Eng
PENGADAAN PEMBANGUNAN
COAL SHELTER PLTU INDRAMAYU
Date : 29 JULI 2019
Report No. : 04/QC-WIR/IV/19
Page : 1 of 2

WELDING INSPECTION REPORT


Customer : PT PLN Part Name : Tali Angin
Unit Name : Coal Shelter Part Number : TL L 61
Description : Tali Angin line 61 Drawing Number : T3131-C-01-11-03-19
FIT UP WELDING ROOT VIS INSP NDT
NO DESCRIPTION JOIN NO
DATE DATE FILL/CAP ACC REJ ACC/REJ REPORT NO.
14 Tali Angin 14 14A 1, 2 27/6/2019 29/6/2019 W 06 √
14B 1, 2 27/6/2019 29/6/2019 W06 √
14C 1, 2 27/6/2019 29/6/2019 W 06 √
15 Tali Angin 15 15A 1, 2 27/6/2019 29/6/2019 W 06 √
15B 1, 2 27/6/2019 29/6/2019 W 06 √
15C 1, 2 27/6/2019 29/6/2019 W 06 √ ACC
16 Tali Angin 16 16A 1, 2 27/6/2019 29/6/2019 W 06 √
16B 1, 2 27/6/2019 29/6/2019 W 06 √
16C 1, 2 27/6/2019 29/6/2019 W 06 √
17 Tali Angin 17 17A 1, 2 27/6/2019 29/6/2019 W 06 √
17B 1, 2 27/6/2019 29/6/2019 W 06 √
17C 1, 2 27/6/2019 29/6/2019 W 06 √
18 Tali Angin 18 18A 1, 2 27/6/2019 29/6/2019 W 06 √
18B 1, 2 27/6/2019 29/6/2019 W 06 √
18C 1, 2 27/6/2019 29/6/2019 W 06 √

Notes :

Inspected By: Reviewed/Witnessed By: Reviewed/Witnessed By:


PT. Waduk Tirta Asih PT Truba Jaya Engineering PT PLN Enjiniring

Ilhamdi Aef Sofyan Ferry


QA/QC Inspector QA/QC Inspector QA/QC Eng