HAMAD GENERAL HOSPITAL SAFETY IMPROVEMENT RMP

PART 1 OF 9
Preambles
Preliminaries
Grand Summary

PART 2 OF 9 (PHASE 01)


HGH Hospital Building Podium
IPT Inpatient Tower

PART 3 OF 9 (PHASE 01)


SV Services Buildings
WT West Tower
SWT South West Tower
NT North Triangle

PART 4 OF 9 (PHASE 02)


HGH Hospital Building Podium
IPT Inpatient Tower

PART 5 OF 9 (PHASE 02)


ENG Engineering Block
SV Services Buildings

PART 6 OF 9 (PHASE 03)


HGH Hospital Building Podium
IPT Inpatient Tower

PART 7 OF 9 (PHASE 03)


OPT Outpatient Tower
ENG Engineering Block
SV Services Buildings
NT North Triangle
General Summary – Construction Works
Phase 1
(BOQ Part 2 of 9)

HOSPITAL BUILDING PODIUM (HGH)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including steel
and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-DAR-


HGH-XX-DR-SS-Z00001/ MHC.HG.01-DAR-
HGH-ZZ-DR-SS-Z29104) (HAMAD
GENERAL HOSPITAL)
Refer to Specifications for these works
Works and materials deemed included. The
mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

A 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 8.45 T
Weight < 25 kg/m, Bracings.

B 15.1.1.3.1.4 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight < 25 kg/m, 0.7 T
Bracings.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-100101-S7-T01 15.1 - Page 1 of 5
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.1.1.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight < 25 0.4 T
kg/m, Beams.

B 15.1.1.1.2.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight 25- 0.15 T
50kg/m, Beams.

C 15.1.1.1.3.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight 50- 0.2 T
100kg/m, Beams.

D 15.1.1.2.1.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 4.2 T
Weight < 25 kg/m, Beams.

E 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 36.41 T
Weight 25-50kg/m, Beams.

F 15.1.1.2.3.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 39.5 T
Weight 50-100kg/m, Beams.

G 15.1.1.3.3.2 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 50- 2.2 T
100kg/m, Beams.

H 15.1.1.2.2.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 16.4 T
Weight 25-50kg/m, Columns.

I 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 24.95 T
Weight 50-100kg/m, Columns.

J 15.1.1.2.4.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 3.2 T
Weight 100-150kg/m, Columns.
To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-100101-S7-T01 15.1 - Page 2 of 5
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.2.5.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 1.55 T
Weight 150-200kg/m, Columns.

B 15.1.2.2.1.4 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 8.45 T
Weight < 25 kg/m, Bracings.

C 15.1.2.3.1.4 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight < 25 kg/m, 0.7 T
Bracings.

D 15.1.2.1.1.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight < 25 0.4 T
kg/m, Beams.

E 15.1.2.1.2.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight 25- 0.15 T
50kg/m, Beams.

F 15.1.2.1.3.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight 50- 0.2 T
100kg/m, Beams.

G 15.1.2.2.1.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 4.2 T
Weight < 25 kg/m, Beams.

H 15.1.2.2.2.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 36.41 T
Weight 25-50kg/m, Beams.

I 15.1.2.2.3.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 39.5 T
Weight 50-100kg/m, Beams.

J 15.1.2.3.3.2 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 50- 2.2 T
100kg/m, Beams.

K 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 16.4 T
Weight 25-50kg/m, Columns.
To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-100101-S7-T01 15.1 - Page 3 of 5
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.2.3.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 24.95 T
Weight 50-100kg/m, Columns.

B 15.1.2.2.4.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 3.2 T
Weight 100-150kg/m, Columns.

C 15.1.2.2.5.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 1.55 T
Weight 150-200kg/m, Columns.

D 15.1.5.2.1 Allowance for fittings including holding down


bolts and assemblies as additional 15% of the
weight of the steel members.

E 15.1.6.2.1.1 Cold-formed purlins and girts including


30.4 T
overlap

F 15.1.15.1.2.4 1 hour intumescent paint fire protection for


1381.66 m2
Structural Steel members.

G 15.1.15.1.2.4 2 hour intumescent paint fire protection for


90 m2
Structural Steel members.

H 15.1.15.3.2.5 Corrosion-protection for structural steel


members to ensure the specified life to first 4937.26 m2
maintenance as per drawings.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-100101-S7-T01 15.1 - Page 4 of 5
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

COLLECTION

Page 1

Page 2

Page 3

Page 4

BILL NO. 15: STRUCTURAL


METALWORK - 15.1 STRUCTURAL
STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-100101-S7-T01 15.1 - Page 5 of 5
Phase 1
(BOQ Part 2 of 9)

INPATIENT TOWER (IPT)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including steel
and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-DAR-


IPT-ZZ-DR-SS-Z00002/ MHC.HG.01-DAR-
IPT-ZZ-DR-SS-Z03209) (INPATIENT
TOWER)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

A 15.1.1.1.1.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight < 25
kg/m, Beams. 0.38 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-100201-S7-T01 15.1 - Page 1 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.2.1.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Columns. 3.57 T

B 15.1.1.2.1.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 3.3 T

C 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 1.73 T

D 15.1.1.2.2.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 4.04 T

E 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 6.28 T

F 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 1.54 T

G 15.1.1.2.3.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 15.19 T

H 15.1.1.3.3.1 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 50-
100kg/m, Columns. 4.89 T

I 15.1.1.3.4.1 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 100-
150kg/m, Columns. 5.45 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-100201-S7-T01 15.1 - Page 2 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.1.1.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight < 25
kg/m, Beams. 0.38 T

B 15.1.2.2.1.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Columns. 3.57 T

C 15.1.2.2.1.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 3.3 T

D 15.1.2.2.1.4 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 1.73 T

E 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 4.04 T

F 15.1.2.2.2.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 6.28 T

G 15.1.2.2.3.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 1.54 T

H 15.1.2.2.3.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 15.19 T

I 15.1.2.3.3.1 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 50-
100kg/m, Columns. 4.89 T

J 15.1.2.3.4.1 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 100-
150kg/m, Columns. 5.45 T
To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-100201-S7-T01 15.1 - Page 3 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.5.2.1 Allowance for fittings including holding down


bolts and assemblies as additional 15% of the
weight of the steel members.

B 15.1.6.2.1.1 Cold-formed purlins and girts including


overlap. 9 T

C 15.1.8.1.1.1 Galvanized composite steel-formed deck


including shear studs. 198.31 m2

D 15.1.15.1.2.4 2 hour cementitious fire protection for


Structural Steel members. 559 m2

E 15.1.15.3.2.5 Corrosion-protection for structural steel


members to ensure the specified life to first
maintenance as per drawings. 1496 m2

To Collection
COLLECTION

Page 1

Page 2

Page 3

Page 4

BILL NO. 15: STRUCTURAL METALWORK - 15.1


To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-100201-S7-T01 15.1 - Page 4 of 4
Phase 1
(BOQ Part 3 of 9)

SERVICE BUILDING (SV)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including
steel and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-DAR-


GN-ZZ-DR-SS-Z00002 TO MHC.HG.01-
DAR-SV-ZZ-DR-SS-Z03505) (SERVICES
BUILDING)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

A 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 6.25 T

B 15.1.1.3.1.4 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight < 25 kg/m,
Bracings. 0.3 T
To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-100501-S7-T01 15.1 - Page 1 of 5
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.1.1.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight < 25
kg/m, Beams. 0.94 T

B 15.1.1.1.4.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight 100-
150kg/m, Beams. 0.2 T

C 15.1.1.2.1.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 16.3 T

D 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 9.5 T

E 15.1.1.2.3.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 12.2 T

F 15.1.1.3.2.2 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 25-50kg/m,
Beams. 0.36 T

G 15.1.1.3.4.2 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 100-
150kg/m, Beams. 31.7 T

H 15.1.1.2.1.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Columns. 6 T

I 15.1.1.2.2.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 3 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-100501-S7-T01 15.1 - Page 2 of 5
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 7.8 T

B 15.1.1.2.4.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 100-150kg/m, Columns. 18.2 T

C 15.1.2.2.1.4 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 6.25 T

D 15.1.2.3.1.4 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight < 25 kg/m,
Bracings. 0.3 T

E 15.1.2.1.1.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight < 25
kg/m, Beams. 0.94 T

F 15.1.2.1.4.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight 100-
150kg/m, Beams. 0.2 T

G 15.1.2.2.1.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 16.3 T

H 15.1.2.2.2.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 9.5 T

I 15.1.2.2.3.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 12.2 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-100501-S7-T01 15.1 - Page 3 of 5
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.3.2.2 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 25-50kg/m,
Beams. 0.36 T

B 15.1.2.3.4.2 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 100-
150kg/m, Beams. 31.7 T

C 15.1.2.2.1.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Columns. 6 T

D 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 3 T

E 15.1.2.2.3.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 7.8 T

F 15.1.2.2.4.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 100-150kg/m, Columns. 18.2 T

G 15.1.5.2.1 Allowance for fittings including holding down


bolts and assemblies as additional 15% of the
weight of the steel members.

H 15.1.6.2.1.1 Cold-formed purlins and girts including


overlap. 15.7 T

I 15.1.15.3.2.5 Corrosion-protection for structural steel


members to ensure the specified life to first
maintenance as per drawings. 5555 m2

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-100501-S7-T01 15.1 - Page 4 of 5
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

COLLECTION

Page 1

Page 2

Page 3

Page 4

BILL NO. 15: STRUCTURAL METALWORK - 15.1


STRUCTURAL STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-100501-S7-T01 15.1 - Page 5 of 5
Phase 1
(BOQ Part 3 of 9)

SOUTH WEST TOWER (SWT)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including
steel and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-DAR-


SWT-ZZ-DR-SS-Z01700 TO MHC.HG.01-
DAR-SWT-ZZ-DR-SS-Z01708) (SOUTH
WEST TOWER)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SWT-XX-BOQ-S100401-S7-T01 15.1 - Page 1 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.2.1.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 1 T
Weight < 25 kg/m, Columns.

B 15.1.1.1.1.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight < 25 0.5 T
kg/m, Beams.

C 15.1.1.2.1.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 1.5 T
Weight < 25 kg/m, Beams.

D 15.1.2.2.1.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 1 T
Weight < 25 kg/m, Columns.

E 15.1.2.1.1.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight < 25 0.5 T
kg/m, Beams.

F 15.1.2.2.1.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 1.5 T
Weight < 25 kg/m, Beams.

G 15.1.5.2.1 Allowance for fittings including holding


down bolts and assemblies as additional 15%
of the weight of the steel members.

H 15.1.15.3.2.5 Corrosion-protection for structural steel


members to ensure the specified life to first 76 m2
maintenance as per drawings.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SWT-XX-BOQ-S100401-S7-T01 15.1 - Page 2 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

COLLECTION

Page 1

Page 2

BILL NO. 15: STRUCTURAL


METALWORK - 15.1 STRUCTURAL
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SWT-XX-BOQ-S100401-S7-T01 15.1 - Page 3 of 3
Phase 1
(BOQ Part 3 of 9)

NORTH TRIANGLE (NT)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including
steel and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish

Refer to Drawing number (MHC.HG.01-


DAR-GN-ZZ-DR-SS-Z01002/ MHC.HG.01-
DAR-GN-ZZ-DR-SS-Z03002) (PUMP
ROOM)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to
fabrication including delivery to site.

A 15.1.1.1.2.1 Framed members, framing and fabrication,


Lengths < 1.00m, Weight 25-50kg/m, 0.27 T
Columns.

B 15.1.1.1.2.2 Framed members, framing and fabrication,


Lengths < 1.00m, Weight 25-50kg/m, 0.035 T
Beams.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-NT-XX-BOQ-S-100601-S7-T01 15.1 - Page 1 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.1.3.2 Framed members, framing and fabrication,


Lengths < 1.00m, Weight 50-100kg/m, 0.14 T
Beams.

B 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 0.46 T
Weight < 25 kg/m, Bracings.

C 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 10.67 T
Weight 25-50kg/m, Beams.

D 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 4.52 T
Weight 50-100kg/m, Columns.

E 15.1.1.2.3.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 6.63 T
Weight 50-100kg/m, Beams.

F 15.1.2.1.2.1 Framed members, permanent erection,


Lengths < 1.00m, Weight 25-50kg/m, 0.27 T
Columns.

G 15.1.2.1.2.2 Framed members, permanent erection,


Lengths < 1.00m, Weight 25-50kg/m, 0.035 T
Beams.

H 15.1.2.1.3.2 Framed members, permanent erection on


site, Lengths < 1.00m, Weight 50-100kg/m, 0.14 T
Beams.

I 15.1.2.2.1.4 Framed members, permanent erection on


site, Lengths over 1.00 but not exceeding 0.46 T
9.00m, Weight < 25 kg/m, Bracings.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-NT-XX-BOQ-S-100601-S7-T01 15.1 - Page 2 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.2.2.2 Framed members, permanent erection on


site, Lengths over 1.00 but not exceeding 10.67 T
9.00m, Weight 25-50kg/m, Beams.

B 15.1.2.2.3.1 Framed members, permanent erection on


site, Lengths over 1.00 but not exceeding 4.52 T
9.00m, Weight 50-100kg/m, Columns.

C 15.1.2.2.3.2 Framed members, permanent erection on


site, Lengths over 1.00 but not exceeding 6.63 T
9.00m, Weight 50-100kg/m, Beams.

D 15.1.5.1.1 Allowance for fittings including holding


down bolts and assemblies as additional 15%
of the weight of the steel members.

E 15.1.8.1.1.1 Galvanized composite steel-formed deck


394 m2
including shear studs.

F 15.1.15.1.2.4 1 hour cementitious fire protection for


652.8 m2
Structural Steel members.

To Collection
COLLECTION

Page 1

Page 2

Page 3

BILL NO. 15: STRUCTURAL


METALWORK - 15.1 STRUCTURAL
STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-NT-XX-BOQ-S-100601-S7-T01 15.1 - Page 3 of 3
Phase 2
(BOQ Part 4 of 9)

HOSPITAL BUILDING PODIUM (HGH)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including steel
and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-DAR-


HGH-XX-DR-SS-Z00001/ MHC.HG.01-DAR-
HGH-ZZ-DR-SS-Z29104) (HAMAD
GENERAL HOSPITAL)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

A 15.1.1.1.1.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight < 25 0.66 T
kg/m, Beams.
A
A
A
13 To Collection
13

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-200102-S7-T01 15.1 - Page 1 of 7
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.1.2.1 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight 25-50 0.6 T
kg/m, Columns.
A
B 15.1.1.1.2.2 Framed members, framing and fabrication,
Lengths not exceeding 1.00m, Weight 25-50 1.13 T
kg/m, Beams.
B
C 15.1.1.1.3.2 Framed members, framing and fabrication,
Lengths not exceeding 1.00m, Weight 50-100 1.48 T
kg/m, Beams.
C
D 15.1.1.1.4.2 Framed members, framing and fabrication,
Lengths not exceeding 1.00m, Weight 100-150 0.84 T
kg/m, Beams.
D
E 15.1.1.2.1.1 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 8.15 T
Weight < 25 kg/m, Columns.
E
F 15.1.1.2.1.2 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 33.9 T
Weight < 25 kg/m, Beams.
F
G 15.1.1.2.1.4 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 11.97 T
Weight < 25 kg/m, Bracings.
G
H 15.1.1.2.2.1 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 18.46 T
Weight 25-50kg/m, Columns.
H
I 15.1.1.2.2.2 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 49.44 T
Weight 25-50kg/m, Beams.
I
I
13 To Collection
13

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-200102-S7-T01 15.1 - Page 2 of 7
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.2.2.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 12.44 T
Weight 25-50kg/m, Bracings.
A
B 15.1.1.2.3.1 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 57.97 T
Weight 50-100kg/m, Columns.
B
C 15.1.1.2.3.2 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 180.55 T
Weight 50-100kg/m, Beams.
C
D 15.1.1.2.4.1 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 10.76 T
Weight 100-150kg/m, Columns.
D
E 15.1.1.2.4.2 Framed members, framing and fabrication,
Lengths over 1.00 but not exceeding 9.00m, 16.85 T
Weight 100-150kg/m, Beams.
E
F 15.1.1.3.2.4 Framed members, framing and fabrication,
Lengths exceeding 9.00m, Weight 25-50kg/m, 4.41 T
Bracings.
F
G 15.1.1.3.3.1 Framed members, framing and fabrication,
Lengths exceeding 9.00m, 7.24 T
Weight 50-100kg/m, Columns.
G
H 15.1.1.3.3.2 Framed members, framing and fabrication,
Lengths exceeding 9.00m, 13.89 T
Weight 50-100kg/m, Beams.
H
I 15.1.1.3.4.1 Framed members, framing and fabrication,
Lengths exceeding 9.00m, 125.16 T
Weight 100-150kg/m, Columns.
I
I
I
13 To Collection
13

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-200102-S7-T01 15.1 - Page 3 of 7
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.3.4.2 Framed members, framing and fabrication,


Lengths exceeding 9.00m, 37.44 T
Weight 100-150kg/m, Beams.
A
B 15.1.2.1.1.2 Framed members, permanent erection on site,
Lengths not exceeding 1.00m, Weight < 25 0.66 T
kg/m, Beams.
B
C 15.1.2.1.2.1 Framed members, permanent erection on site,
Lengths not exceeding 1.00m, Weight 25-50 0.6 T
kg/m, Columns.
C
D 15.1.2.1.2.2 Framed members, permanent erection on site,
Lengths not exceeding 1.00m, Weight 25-50 1.13 T
kg/m, Beams.
D
E 15.1.2.1.3.2 Framed members, permanent erection on site,
Lengths not exceeding 1.00m, Weight 50-100 1.48 T
kg/m, Beams.
E
F 15.1.2.1.4.2 Framed members, permanent erection on site,
Lengths not exceeding 1.00m, Weight 100-150 0.84 T
kg/m, Beams.
F
G 15.1.2.2.1.1 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 8.15 T
Weight < 25 kg/m, Columns.
G
H 15.1.2.2.1.2 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 33.9 T
Weight < 25 kg/m, Beams.
H
I 15.1.2.2.1.4 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 11.97 T
Weight < 25 kg/m, Bracings.
I
I
13 To Collection
13

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-200102-S7-T01 15.1 - Page 4 of 7
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m, 18.46 T
Weight 25-50kg/m, Columns.
A
B 15.1.2.2.2.2 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 49.44 T
Weight 25-50kg/m, Beams.
B
C 15.1.2.2.2.4 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 12.44 T
Weight 25-50kg/m, Bracings.
C
D 15.1.2.2.3.1 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 57.97 T
Weight 50-100kg/m, Columns.
D
E 15.1.2.2.3.2 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 180.55 T
Weight 50-100kg/m, Beams.
E
F 15.1.2.2.4.1 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 10.76 T
Weight 100-150kg/m, Columns.
F
G 15.1.2.2.4.2 Framed members, permanent erection on site,
Lengths over 1.00 but not exceeding 9.00m, 16.85 T
Weight 100-150kg/m, Beams.
G
H 15.1.2.3.2.4 Framed members, permanent erection on site,
Lengths exceeding 9.00m, Weight 25-50kg/m, 4.41 T
Bracings.
H
I 15.1.2.3.3.1 Framed members, permanent erection on site,
Lengths exceeding 9.00m, 7.24 T
Weight 50-100kg/m, Columns.
I
I
13 To Collection
13

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-200102-S7-T01 15.1 - Page 5 of 7
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.3.3.2 Framed members, permanent erection on site,


Lengths exceeding 9.00m, 13.89 T
Weight 50-100kg/m, Beams.
A
B 15.1.2.3.4.1 Framed members, permanent erection on site,
Lengths exceeding 9.00m, 125.16 T
Weight 100-150kg/m, Columns.
B
C 15.1.2.3.4.2 Framed members, permanent erection on site,
Lengths exceeding 9.00m, 37.44 T
Weight 100-150kg/m, Beams.
C
C 15.1.5.2.1 Allowance for fittings including holding down
bolts and assemblies as additional 15% of the
weight of the steel members.
C
D 15.1.6.2.1.1 Cold-formed purlins and girts including
94.1 T
overlap.
D
E 15.1.8.1.1.1 Galvanized composite steel-formed deck
567.78 m2
including shear studs.
E
F 15.1.15.1.2.4 1 hour intumescent paint fire protection for
8451.4 m2
Structural Steel members.
F
G 15.1.15.3.2.5 Corrosion-protection for structural steel
members to ensure the specified life to first 13378 m2
maintenance as per drawings.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-200102-S7-T01 15.1 - Page 6 of 7
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

COLLECTION

Page 1

Page 2

Page 3

Page 4

Page 5

Page 6

BILL NO. 15: STRUCTURAL


METALWORK - 15.1 STRUCTURAL
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-HGH-XX-BOQ-S-200102-S7-T01 15.1 - Page 7 of 7
Phase 2
(BOQ Part 4 of 9)

INPATIENT TOWER (IPT)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including
steel and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-DAR-


IPT-ZZ-DR-SS-Z00002/ MHC.HG.01-DAR-
IPT-ZZ-DR-SS-Z03209) (INPATIENT
TOWER)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

A 15.1.1.1.1.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight < 25
kg/m, Beams. 0.72 T

B 15.1.1.2.1.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Columns. 5.97 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-200201-S7-T01 15.1 - Page 1 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.2.1.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 5.54 T

B 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 2.74 T

C 15.1.1.2.2.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 6.64 T

D 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 11.06 T

E 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 3.08 T

F 15.1.1.1.3.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight 50-
100kg/m, Beams.
0.36 T

G 15.1.1.2.3.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams.
25.97 T

H 15.1.1.3.3.1 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 50-
100kg/m, Columns. 9.78 T

I 15.1.1.3.4.1 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 100-
150kg/m, Columns. 10.9 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-200201-S7-T01 15.1 - Page 2 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.1.1.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight < 25
kg/m, Beams. 0.72 T

B 15.1.2.2.1.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Columns. 5.97 T

C 15.1.2.2.1.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 5.54 T

D 15.1.2.2.1.4 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 2.74 T

E 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 6.64 T

F 15.1.2.2.2.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 11.06 T

G 15.1.2.2.3.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 3.08 T

H 15.1.2.1.3.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight 50-
100kg/m, Beams. 0.36 T

I 15.1.2.2.3.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 25.97 T

J 15.1.2.3.3.1 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 50-
100kg/m, Columns. 9.78 T
To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-200201-S7-T01 15.1 - Page 3 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.3.4.1 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 100-
150kg/m, Columns. 10.9 T

B 15.1.5.2.1 Allowance for fittings including holding down


bolts and assemblies as additional 15% of the
weight of the steel members.

C 15.1.6.2.1.1 Cold-formed purlins and girts including


overlap. 11.1 T

D 15.1.8.1.1.1 Galvanized composite steel-formed deck


including shear studs. 400.3 m2

E 15.1.15.1.2.4 2 hour cementitious fire protection for


2
Structural Steel members. 1094 m

F 15.1.15.3.2.5 Corrosion-protection for structural steel


members to ensure the specified life to first
maintenance as per drawings. 2342 m2

To Collection
COLLECTION

Page 1

Page 2

Page 3

Page 4

BILL NO. 15: STRUCTURAL METALWORK - 15.1


STRUCTURAL STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-200201-S7-T01 15.1 - Page 4 of 4
Phase 2
(BOQ Part 5 of 9)

SERVICE BUILDING (SV)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including steel
and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-DAR-


GN-ZZ-DR-SS-Z00002 TO MHC.HG.01-
DAR-SV-ZZ-DR-SS-Z03505) (SERVICES
BUILDING)

Refer to Specifications for these works


Works and materials deemed included. The
mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

A 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 0.3 T

B 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 1.73 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-200502-S7-T01 15.1 - Page 1 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.3.2.2 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 25-50kg/m,
Beams. 1.25 T

B 15.1.1.2.2.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 0.18 T

C 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 2.2 T

D 15.1.2.2.1.4 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 0.3 T

E 15.1.2.2.2.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 1.73 T

F 15.1.2.3.2.2 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 25-50kg/m,
Beams. 1.25 T

G 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 0.18 T

H 15.1.2.2.3.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 2.2 T

I 15.1.5.2.1 Allowance for fittings including holding down


bolts and assemblies as additional 15% of the
weight of the steel members. Item

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-200502-S7-T01 15.1 - Page 2 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.6.2.1.1 Cold-formed purlins and girts including


overlap. 11 T

B 15.1.15.3.2.5 Corrosion-protection for structural steel


members to ensure the specified life to first
maintenance as per drawings. 650 m2

To Collection

COLLECTION

Page 1

Page 2

Page 3

BILL NO. 15: STRUCTURAL METALWORK - 15.1


STRUCTURAL STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-200502-S7-T01 15.1 - Page 3 of 3
Phase 3
(BOQ Part 6 of 9)

INPATIENT TOWER (IPT)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including
steel and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-DAR-


IPT-ZZ-DR-SS-Z00002/ MHC.HG.01-DAR-
IPT-ZZ-DR-SS-Z03209) (INPATIENT
TOWER)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

A 15.1.1.1.1.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight < 25
kg/m, Beams. 0.4 T

B 15.1.1.2.1.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Columns. 4.16 T
To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-300201-S7-T01 15.1 - Page 1 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.2.1.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 3.62 T

B 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 1.14 T

C 15.1.1.2.2.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 4.39 T

D 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 6.49 T

E 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 1.54 T

F 15.1.1.2.3.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 15.21 T

G 15.1.1.3.3.1 Framed members, framing and fabrication,


Lengths exceeding 9.00m,
Weight 50-100kg/m, Columns. 4.9 T

H 15.1.1.3.4.1 Framed members, framing and fabrication,


Lengths exceeding 9.00m,
Weight 100-150kg/m, Columns. 5.45 T

I 15.1.2.1.1.2 Framed members, permanent erection on site,


Lengths < 1.00m, Weight < 25 kg/m, Beams.
0.4 T

J 15.1.2.2.1.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Columns. 4.16 T
To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-300201-S7-T01 15.1 - Page 2 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.2.1.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 3.62 T

B 15.1.2.2.1.4 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 1.14 T

C 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 4.39 T

D 15.1.2.2.2.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 6.49 T

E 15.1.2.2.3.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 1.54 T

F 15.1.2.2.3.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 15.21 T

G 15.1.2.3.3.1 Framed members, permanent erection on site,


Lengths exceeding 9.00m,
Weight 50-100kg/m, Columns. 4.89 T

H 15.1.2.3.4.1 Framed members, permanent erection on site,


Lengths exceeding 9.00m,
Weight 100-150kg/m, Columns. 5.45 T

I 15.1.5.2.1 Allowance for fittings including holding down


bolts and assemblies as additional 15% of the
weight of the steel members.

J 15.1.6.2.1.1 Cold-formed purlins and girts including


overlap. 9.5 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-300201-S7-T01 15.1 - Page 3 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.8.1.1.1 Galvanized composite steel-formed deck


including shear studs. 198.2 m2

B 15.1.15.1.2.4 2 hour cementitious fire protection for


Structural Steel members. 553.5 m2

C 15.1.15.3.2.5 Corrosion-protection for structural steel


members to ensure the specified life to first
maintenance as per drawings. 1621 m2

To Collection

COLLECTION

Page 1

Page 2

Page 3

Page 4

BILL NO. 15: STRUCTURAL METALWORK - 15.1


STRUCTURAL STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-IPT-XX-BOQ-S-300201-S7-T01 15.1 - Page 4 of 4
Phase 3
(BOQ Part 7 of 9)

OUTPATIENT TOWER (OPT)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including
steel and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.

Refer to Drawing number (MHC.HG.01-


DAR-OPT-ZZ-DR-SS-Z01301/ MHC.HG.01-
DAR-GN-ZZ-DR-SS-Z01302) (CLADDING
SUPPORT AND IDF ROOM)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to
fabrication including delivery to site.

A 15.1.1.1.2.1 Framed members, framing and fabrication,


Lengths < 1.00m, Weight 25-50kg/m,
Columns. 0.32 T

B 15.1.1.1.2.2 Framed members, framing and fabrication,


Lengths < 1.00m, Weight 25-50kg/m, Beams.
0.21 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-OPT-XX-BOQ-S-300301-S7-T01 15.0 - Page 1 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.2.1.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight less than 25kg/m, Columns. 0.21 T

B 15.1.1.2.2.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 1.22 T

C 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 2.71 T

D 15.1.1.3.3.1 Framed members, framing and fabrication,


Lengths > 9m, Weight 50-100kg/m, 4.15 T

E 15.1.2.1.2.1 Framed members, permanent erection on site,


Lengths < 1.00m, Weight 25-50kg/m,
Columns. 0.32 T

F 15.1.2.1.2.2 Framed members, permanent erection on site,


Lengths < 1.00m, Weight 25-50kg/m, Beams.
0.21 T

G 15.1.2.2.1.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight less than 25kg/m, Columns. 0.21 T

H 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 1.22 T

I 15.1.2.2.2.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 2.71 T

J 15.1.2.3.3.1 Framed members, permanent erection on site,


Lengths > 9m, Weight 50-100kg/m,
Columns. 4.15 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-OPT-XX-BOQ-S-300301-S7-T01 15.0 - Page 2 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.5.2.1 Allowance for fittings including holding


down bolts and assemblies as additional 15%
of the weight of the steel members.

B 15.1.8.1.1.1 Galvanized composite steel-formed deck


with shear studs. 81.25 m2

C 15.1.15.1.2.4 1 hour cementitious fire protection for


Structural Steel members. 148.1 m2

D 15.1.15.3.2.5 Corrosion-protection for structural steel


memebers to ensure the specified life to first
maintenance as per drawings. 98.78 m2

To Collection
COLLECTION

Page 1

Page 2

Page 3

BILL NO. 15: STRUCTURAL


METALWORK - 15.1 STRUCTURAL
STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-OPT-XX-BOQ-S-300301-S7-T01 15.0 - Page 3 of 3
Phase 3
(BOQ Part 7 of 9)

SERVICE BUILDING (SV)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including
steel and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish.
Refer to Drawing number (MHC.HG.01-DAR-
GN-ZZ-DR-SS-Z00002 TO MHC.HG.01-
DAR-SV-ZZ-DR-SS-Z03505) (SERVICES
BUILDING)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components
Permanent erection is deemed to include all
specified operations subsequent to fabrication
including delivery to site.

A 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 2.7 T

B 15.1.1.3.1.4 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight < 25 kg/m,
Bracings. 0.32 T
To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-300501-S7-T01 15.1 - Page 1 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.1.3.2 Framed members, framing and fabrication,


Lengths not exceeding 1.00m, Weight 50-
100kg/m, Beams. 0.02 T

B 15.1.1.2.1.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 1.5 T

C 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 1.3 T

D 15.1.1.2.3.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 2.5 T

E 15.1.1.3.3.2 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 50-
100kg/m, Beams. 6.3 T

F 15.1.1.3.4.2 Framed members, framing and fabrication,


Lengths exceeding 9.00m, Weight 100-
150kg/m, Beams. 3.4 T

G 15.1.1.2.2.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 1.2 T

H 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 4.4 T

I 15.1.1.2.4.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 100-150kg/m, Columns. 4.6 T

J 15.1.1.2.5.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m,
Weight 150-200kg/m, Columns. 0.75 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-300501-S7-T01 15.1 - Page 2 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.2.1.4 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Bracings. 2.7 T

B 15.1.2.3.1.4 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight < 25 kg/m,
Bracings. 0.32 T

C 15.1.2.1.3.2 Framed members, permanent erection on site,


Lengths not exceeding 1.00m, Weight 50-
100kg/m, Beams. 0.02 T

D 15.1.2.2.1.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight < 25 kg/m, Beams. 1.5 T

E 15.1.2.2.2.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Beams. 1.3 T

F 15.1.2.2.3.2 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Beams. 2.5 T

G 15.1.2.3.3.2 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 50-
100kg/m, Beams. 6.3 T

H 15.1.2.3.4.2 Framed members, permanent erection on site,


Lengths exceeding 9.00m, Weight 100-
150kg/m, Beams. 3.4 T

I 15.1.2.2.2.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 25-50kg/m, Columns. 1.2 T

J 15.1.2.2.3.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 50-100kg/m, Columns. 4.4 T

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-300501-S7-T01 15.1 - Page 3 of 4
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.2.4.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 100-150kg/m, Columns. 4.6 T

B 15.1.2.2.5.1 Framed members, permanent erection on site,


Lengths over 1.00 but not exceeding 9.00m,
Weight 150-200kg/m, Columns. 0.75 T

C 15.1.5.2.1 Allowance for fittings including holding


down bolts and assemblies as additional 15%
of the weight of the steel members.

D 15.1.6.2.1.1 Cold-formed purlins and girts includiong


overlap. 11.6 T

E 15.1.15.3.2.5 Corrosion-protection for structural steel


members to ensure the specified life to first
maintenance as per drawings. 2110 m2

To Collection

COLLECTION

Page 1

Page 2

Page 3

Page 4

BILL NO. 15: STRUCTURAL


METALWORK - 15.1 STRUCTURAL
STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-SV-XX-BOQ-S-300501-S7-T01 15.1 - Page 4 of 4
Phase 3
(BOQ Part 7 of 9)

NORTH TRIANGLE (NT)


Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

BILL NO. 15: STRUCTURAL


METALWORK

1. Structural Steelwork

15.1 STRUCTURAL STEELWORK

Drawings that accompany this section of


measurement. Structural Steel (s) which
shows,
1. Types and grade of materials including
steel and steel to steel bolts.
2. Specification describing fabrication,
welding, testing, erection and everything else
necessary to complete the installation.
3. Surface preparation prior to application of
any surface treatment or finish

Refer to Drawing number (MHC.HG.01-


DAR-GN-ZZ-DR-SS-Z01002/ MHC.HG.01-
DAR-GN-ZZ-DR-SS-Z03002) (PUMP
ROOM)

Refer to Specifications for these works

Works and materials deemed included. The


mass of framing includes all components.
Permanent erection is deemed to include all
specified operations subsequent to
fabrication including delivery to site.

A 15.1.1.1.2.1 Framed members, framing and fabrication,


Lengths < 1.00m, Weight 25-50kg/m, 0.27 T
Columns.

B 15.1.1.1.2.2 Framed members, framing and fabrication,


Lengths < 1.00m, Weight 25-50kg/m, 0.035 T
Beams.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-NT-XX-BOQ-S-100601-S7-T01 15.1 - Page 1 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.1.1.3.2 Framed members, framing and fabrication,


Lengths < 1.00m, Weight 50-100kg/m, 0.14 T
Beams.

B 15.1.1.2.1.4 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 0.46 T
Weight < 25 kg/m, Bracings.

C 15.1.1.2.2.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 10.67 T
Weight 25-50kg/m, Beams.

D 15.1.1.2.3.1 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 4.52 T
Weight 50-100kg/m, Columns.

E 15.1.1.2.3.2 Framed members, framing and fabrication,


Lengths over 1.00 but not exceeding 9.00m, 6.63 T
Weight 50-100kg/m, Beams.

F 15.1.2.1.2.1 Framed members, permanent erection,


Lengths < 1.00m, Weight 25-50kg/m, 0.27 T
Columns.

G 15.1.2.1.2.2 Framed members, permanent erection,


Lengths < 1.00m, Weight 25-50kg/m, 0.035 T
Beams.

H 15.1.2.1.3.2 Framed members, permanent erection on


site, Lengths < 1.00m, Weight 50-100kg/m, 0.14 T
Beams.

I 15.1.2.2.1.4 Framed members, permanent erection on


site, Lengths over 1.00 but not exceeding 0.46 T
9.00m, Weight < 25 kg/m, Bracings.

To Collection

STRUCTURAL STEELWORK
MHC.HG.01-DAR-NT-XX-BOQ-S-100601-S7-T01 15.1 - Page 2 of 3
Hamad General Hospital Safety Improvement RMP
Bill of Quantities

Item Ref Description Qty Unit Rate Amount


QR QR

A 15.1.2.2.2.2 Framed members, permanent erection on


site, Lengths over 1.00 but not exceeding 10.67 T
9.00m, Weight 25-50kg/m, Beams.

B 15.1.2.2.3.1 Framed members, permanent erection on


site, Lengths over 1.00 but not exceeding 4.52 T
9.00m, Weight 50-100kg/m, Columns.

C 15.1.2.2.3.2 Framed members, permanent erection on


site, Lengths over 1.00 but not exceeding 6.63 T
9.00m, Weight 50-100kg/m, Beams.

D 15.1.5.1.1 Allowance for fittings including holding


down bolts and assemblies as additional 15%
of the weight of the steel members.

E 15.1.8.1.1.1 Galvanized composite steel-formed deck


394 m2
including shear studs.

F 15.1.15.1.2.4 1 hour cementitious fire protection for


652.8 m2
Structural Steel members.

To Collection
COLLECTION

Page 1

Page 2

Page 3

BILL NO. 15: STRUCTURAL


METALWORK - 15.1 STRUCTURAL
STEELWORK
To Summary QR

STRUCTURAL STEELWORK
MHC.HG.01-DAR-NT-XX-BOQ-S-100601-S7-T01 15.1 - Page 3 of 3