Date: 09.10.

2015
Ash Sample Analysis

Ash Analysis (Dust Collecting Fan):

Moisture = 0.32 %
Ash = 74.28 %
Volatile Matters = 10.78 %
Carbon
F.C = 100- (% moisture + % Ash + % Volatile matters)

F.C = 100- (0.32 + 74.28+ 10.78)

F.C = 100 – 85.38

F.C = 14.62 %
Ash Sieve Analysis

Grain Size Weight %


Fixed Carbon
(mm) out of 19 VM % Moisture % Ash %
%
(grams)
+ 0.088 72.49 17.13
44 10.29 0.09
(Retained)
-0.088 71.41 18.65
55.7 9.8 0.14
(Pass)

Loss in Weight: 0.3%