Appendix-A: Hollowcore Slabs Design

Job # :

(A-1). Design of Hollowcore Slabs 200mm Thickness At Typical Floor:

Design of the Hc-Slabs For Gravity Loads:

●Hollowcore Slabs Thick: = 200 mm


●C.I.S Top Slabs Thick: = 60 mm (noncomposite section)

Strands Number & Size Offset from soffit Jacking Force


Layer-1 7 - # 12.7mm 35mm 110 kN

●Max Span Length = 6.5 m


●Max imposed Live Load = 2.4 kN/m
●Dead Load of topping = 1.8 kN/m
●Max imposed Dead Load = 7.2 kN/m

CONCISE BEAM software ver. 4.47j has been used to design the HC-slabs
against gravity load (Dead Load + Live Load) view the next pages.
DESIGN OF SOLID SLAB PRESTRESS

Design of Solid Slab prestress first floor 150mm FPS15-02 typical floor:

Design of prestressed slab first floor FPS15-02:

●SSP THICKNESS = 150 mm


●C.I.S Top Slabs Thick: = 110 mm

Strands Number & Size Offset from soffit Jacking Force


Layer-1 10 - # 12.73mm 35mm 115 kN

2,3

3.9m 2.17m

6.07m

(1).Current Floor (2).Roof Floor (3).Earth Quake


DL LL DL LL NEX(kN)

7.2 3 40.68 4.7 10.14


DESIGN OF SOLID SLAB PRESTRESS

Slab width = 1.2 m

Wall length = 3.42 m

Wall height = 3.3 m

Parapet height = 1.2 m

Lever Arm 0.8*L = 2.732 m (assumed)

Weight of HC265= 3.45 kN/m2

1) Dead Load:

DLparapet = (1.2*0.12*25)*1.2 = 4.32 kN

DLwall = (3.3*0.2*25)*1.2 = 19.8 kN

DLRoof HC = 3.92/2*(3.45+0.06*25+3.5)*1.2 = 16.56 kN

Total concentrated load= 40.682 kN

DLcurrent story = 6*1.2 = 7.2 kN/m

2) Live Load:

LLRoof HC = 3.92/2*(2)*1.2 = 4.704 kN

LLCurrent Story = 1.2*(2.5) = 3 kN/m

3)Additional vertical loads resulting from bending moment

Bending moment from EY= 27.7 kNm (from Etabs)

Assuming a lever arm of 0.8L= 10.14 kN


DESIGN OF SOLID SLAB PRESTRESS

3.92m
DESIGN OF SOLID SLAB PRESTRESS

Design and analysis of Prestressed solid slab is done using Concise Beam below find attached Concise
Concise Beam Output.
DESIGN OF SOLID HOLLOWCORE SLAB

Design of HC 150mm FPS15-08 typical floor:

Design of the FPS15-08-Slabs:

●SSP THICKNESS = 150 mm


●C.I.S Top Slabs Thick: = 110 mm

Strands Number & Size Offset from soffit Jacking Force


Layer-1 10 - # 12.73mm 35mm 115 kN

1.25m 3.405m 1.43m

6.17m

(1).Current Floor (2).Roof Floor (3).Roof Floor (4).Earth Quake


DL LL DL LL DL LL NEX(kN)

7.2 3 40.851 3.96 40.851 3.96 10.14


DESIGN OF SOLID HOLLOWCORE SLAB

Slab width = 1.2 m

Wall length = 3.40 m

Wall height = 3.30 m

Parapet height = 1.2 m

Lever Arm 0.8*L = 2.72 m (assumed)

Weight of HC265= 3.45 kN/m2

1) Dead Load:

DLparapet = (1.2*0.12*25)*1.2 = 4.32 kN

DLwall = (3.3*0.2*25)*1.2 = 19.8 kN

DLRoof HC = 3.3/2*(3.45+0.06*25+3.5)*1.2 = 16.73 kN

Total concentrated 40.851 kN

DLcurrent story = 6*1.2 = 7.2 kN/m

2) Live Load:

LLRoof HC = 3.3/2*(2)*1.2 = 3.96 kN

LLCurrent Story = 1.2*(2.5) = 3 kN/m

3)Additional vertical loads resulting from bending moment

Bending moment from EY= 18 kNm (from Etabs)

Assuming a lever arm of 0.8L= 6.618 kN


DESIGN OF SOLID HOLLOWCORE SLAB

Concerned
Hollowcore Slab

1.43m 3.405m 1.34m


DESIGN OF SOLID HOLLOWCORE SLAB

Design and analysis of Reinforced solid slab is done using Concise Beam below fond attached
Concise Beam Output.
DESIGN OF SOLID SLAB PRESTRESS

Design of Prestressed Hollow Core Slab 200 FHC20-04 typical floor:

Design of the FHC20-04-Slab:

●HC THICKNESS = 200 mm


●C.I.S Top Slabs Thick: = 60 mm

Strands Number & Size Offset from soffit Jacking Force


Layer-1 7 - # 12.73mm 35mm 115 kN

5.37m

Slab width = 1.2 m

SDL= 6*1.2= 7.2 kN/ml

LL= 2.5*1.2 = 3 kN/ml


DESIGN OF SOLID SLAB PRESTRESS
Design and analysis of Hollow Core slab is done using Concise Beam below find attached Concise
Beam Output.
DESIGN OF SOLID SLAB PRESTRESS

Design of Prestressed Hollow Core Slab 265 FHC265-13 typical floor:

Design of Prestressed Hollow Slab FHC265-13-Slab:

●HC THICKNESS = 265 mm


●C.I.S Top Slabs Thick: = 60 mm

Strands Number & Size Offset from soffit Jacking Force


Layer-1 7 - # 12.73mm 35mm 115 kN

8.07m

Slab width = 1.2 m

SDL= 3.5*1.2= 4.2 kN/ml

LL= 2*1.2 = 2.4 kN/ml


DESIGN OF SOLID SLAB PRESTRESS
Design and analysis of Reinforced solid slab is done using Concise Beam below fond attached Concise
Beam Output.
DESIGN OF SOLID SLAB PRESTRESS

Design of Prestressed Hollow Core Slab 200 FHC20-04 typical floor:

Design of Prestressed Hollow Slab FHC260-04-Slab:

●HC THICKNESS = 265 mm


●C.I.S Top Slabs Thick: = 60 mm

Strands Number & Size Offset from soffit Jacking Force


Layer-1 7 - # 12.73mm 35mm 115 kN
*Only the uncut strand shall be considered in design

8.35m

Slab width = 1.2 m

SDL= 3.5*1.2 = 4.2 kN/ml

LL= 2*1.2 = 2.4 kN/ml


DESIGN OF SOLID SLAB PRESTRESS
Design and analysis of Reinforced solid slab is done using Concise Beam below fond attached Concise
Beam Output.
DESIGN OF SOLID SLAB PRESTRESS
Design of Prestressed Solid Slab 200 FPS260-01 typical floor:

Design of Prestressed Hollow Slab FPS260-01-Slab:

●HC THICKNESS = 265 mm


●C.I.S Top Slabs Thick: = 60 mm

Strands Number & Size Offset from soffit Jacking Force


Layer-1 6 - # 12.73mm 35mm 115 kN
*Conservatively only the uncut strand shall be considered in design

3.675m 0.38m 3.97m

8.035m

Slab width = 0.84 m

SDL=3.5*0.84= 2.94 kN/ml

LL= 2*0.84= 1.68 kN/ml

Loads from HC265.

SDL= 3.675/2*(0.06*25+3.5+3.45)/4 = 3.9 kN

SDL= 3.97/2*(0.06*25+3.5+3.45)/4 = 4.2 kN

LL= 3.675/2*(2)/4 = 0.92 kN

LL= 3.97/2*(2)/4 = 0.99 kN


DESIGN OF SOLID SLAB PRESTRESS
Design and analysis of Reinforced solid slab is done using Concise Beam below fond attached Concise
Beam Output.
DESIGN OF SOLID SLAB PRESTRESS

Design of Reinforced Slab FSS20-03 typical floor:

Design of Prestressed Hollow Slab Reinforced Slab FSS20-03 Slab:

●HC THICKNESS = 200 mm


●C.I.S Top Slabs Thick: = 60 mm

8.035m

Slab width = 1.63 m

SDL=3.5*1.63= 5.71 kN/ml

LL=2*1.63= 3.26 kN/ml


DESIGN OF SOLID SLAB PRESTRESS
Design and analysis of Reinforced solid slab is done using Concise Beam below fond attached Concise