You are on page 1of 40

aerospace

climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding

PAVC Medium Pressure


Super Charged Piston Pumps
Variable Displacement For Open Circuits
Catalog: HY28-2662-CD/US Effective: April 01, 2012
WARNING - USER RESPONSIBILITY
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation
by users having technical expertise.

The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is
responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance
are governed by the provisions stated in the detailed "Offer of Sale" elsewhere in this document.

© Copyright 2012, Parker Hannifin Corporation. All Rights Reserved.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Contents Series PAVC

Contents
Introduction.................................................................................................................................................................4
Ordering Information..................................................................................................................................................7
Control Options 33/38/65/100.....................................................................................................................................8
Technical Information................................................................................................................................................13
PAVC 33/38
Technical Information 33/38...............................................................................................................................14
Performance Data 33/38....................................................................................................................................15
Dimensional Data 33/38....................................................................................................................................18
PAVC 65
Technical Information 65....................................................................................................................................20
Performance Data 65.........................................................................................................................................21
Dimensional Data 65.........................................................................................................................................23
PAVC 100
Technical Information 100..................................................................................................................................26
Performance Data 100.......................................................................................................................................27
Dimensional Data 100.......................................................................................................................................29
Installation Information 33/38/65/100.......................................................................................................................34
Offer of Sale.............................................................................................................................................................39

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 3
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Introduction Series PAVC

Quick Reference Data Chart


Pump Delivery *Approx. Noise Levels dB(A) Input Power At Operating Pressure
Displacement @ 21 bar (300 PSI) @ Full Flow 1800 RPM (1200 RPM)
Pump 1800 RPM, Maximum Speed bar (PSI)
CM3/REV in LPM (GPM)
Model 34 bar 69 bar 138 bar 207 bar Displacement & RPM Continuous
(IN3/REV)
1200 RPM 1800 RPM (500 PSI) (1000 PSI) (2000 PSI) (3000 PSI) 207 bar (3000 PSI) (Maximum) (Maximum)
PAVC33   33 (2.0) 39.4 (10.4) 59.0 (15.6) 75 (69) 76 (72) 78 (75) 79 (77) 21.3 kw (28.5 hp) 3000 207 (3000)
PAVC38   38 (2.3) 45.0 (11.9) 67.8 (17.9) 75 (69) 76 (72) 78 (75) 79 (77) 24.6 kw (33.0 hp) 3000 207 (3000)
PAVC65   65 (4.0) 78.7 (20.8) 118.1 (31.2) 77 (75) 78 (76) 80 (78) 81 (79) 43.1 kw (57.8 hp) 3000 207 (3000)
PAVC100 100 (6.1) 119.6 (31.6) 179.8 (47.5) 83 (77) 82 (78) 82 (79) 85 (80) 71.2 kw (95.5 hp) 2600 207 (3000)
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal
to those in the field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at
1 meter from the pump, measured and recorded in accordance with applicable ISO and NFPA standards.

Parker Hannifin Corporation


Hydraulic Pump Division
4 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Introduction Series PAVC

PUMP REPLACEABLE HYDRODYNAMIC REAR


HOUSING PORT PLATE BEARING COVER

SEALED
BEARING

SHAFT
SEAL

CYLINDER SERVO
BARREL PISTON

Features Controls
• High Strength Cast-Iron Housing • Pressure Compensation
• Built-In Supercharger Ensures High Speed • Load Sensing
Capability ‑ 3000 RPM (2600 RPM PAVC100) • Power (Torque) Limiting
• Sealed Shaft Bearing • Power and Load Sensing
• Two Piece Design for Ease of Service • Remote Pressure Compensation
• Cartridge Type Controls ‑ Field Changeable • Adjustable Maximum Volume Stop
• Replaceable Bronze Clad Port Plate • Low Pressure Standby
• Airbleed Standard for Quick Priming
• Hydrodynamic Cylinder Barrel Bearing
• Thru-Shaft (PAVC100 Only)
• Full Pressure Rating on Most Water Glycol Fluids
• Pump Case and Shaft Seal are Subjected
to Inlet Pressure Only
• Filter and/or Cool Drain Line
7 bar (100 PSI) Maximum

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 5
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Introduction Series PAVC 33/38/65/100

General Description
All control is achieved by the proper positioning of the the swash plate. When the swash plate is in a vertical
swash plate. This is achieved by a servo piston acting on position, perpendicular to the centerline of the piston
one end of the swash plate working against the combined barrel, there is no piston stroke and consequently no
effect of the off-setting forces of the pistons and centering fluid displacement. When the swash plate is positioned
spring on the other end. The control spool acts as a at an angle, the pistons are forced in and out of the barrel
metering valve which varies the pressure behind the and fluid displacement takes place. The greater the angle
servo piston. of the swash plate, the greater the piston stroke.
As shown in Figure 1, the amount of flow produced by The centerline of the pumping piston assembly is offset
the Parker Piston Pump is dependent upon the length of from the centerline of the swash plate. Therefore, as
stroke of the pumping pistons. This length of stroke, in shown on the accompanying Figure 1A, the pistons’
turn, is determined by the position of the swash plate. effective summation force tends to destroke the swash
Maximum flow is achieved at an angle of 17°. plate to a vertical (neutral) position. This destroking force
is balanced as the swash plate is angled by the force of
The rotating piston barrel, driven by the prime mover,
the servo piston.
moves the pistons in a circular path and the piston
slippers are supported hydrostatically against the face of

ROTATING
PISTON
BARREL

PUMPING SUMMATION OF
PISTON OUTPUT PISTON FORCES

DRIVE
SHAFT

INPUT

OIL FLOW

SERVO PISTON
SWASH
PLATE

FIGURE 1. Pumping Action FIGURE 1A.

Parker Hannifin Corporation


Hydraulic Pump Division
6 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Ordering Information Series PAVC

PAVC 4 Omit

Displacement Volume Thru- Multiple


Multiple Pump Shaft Outlet Inlet Rotation Thru- Control Paint
Pumps Axial Piston Option Port Port Stop Shaft Shaft Options Pumps
Bearing Adjustable Option Threads Variations Nitrile
Variable
Option Differential (Standard)
Controllable
Seals

Code Multiple Pumps Inlet Port


Code
Omit Single Pump 33/38 Inlet 65 Inlet 100 Inlet Type
Factory Mounted to Rear Omit Str. Thd., Rear Str. Thd., Rear Flange, Rear SAE/Inch Threads

of Another Pump 2 Flange, Side Flange, Top Flange, Top/Bottom SAE/Inch Threads

Code Displacement in3/rev (cm3/rev) Code Rotation* Code Control Option


33 2.0 (33) R Right CW Standard Pressure Compensated
38 2.3 (38) L Left CCW Omit Setting Pressure 41-207 bar
(600-3000 PSI)
65 4.0 (65) * Viewed from shaft end.
 A Pressure & Flow (Load Sensing)
100 6.1 (100)
Code Volume Stop Options *C Pressure, Flow & Power
Code Bearing Option Omit Volume Stop Plugged *H Pressure Comp. & Power
Omit Single Piece Shaft 2 Maximum Volume Stop **†M Remote Pressure
9* Dual Bearing 5* Max. Volume Stop with O-ring **†ME Remote Pressure
* For applications where side loading * Not available with Thru- †AM Remote Pressure & Flow
may be experienced. Max. side Shaft option on Size 100.
*†CM  Remote Pressure, Flow & Power
load = 113.4 kg (250 lbs).
*†HM  Remote Pressure & Power
Typical Applications: Code Thru-Shaft Threads*
Belt/chain drive * Power controlled pumps (H, C, HM or CM) must
Universal joint drive
Omit No Thru-Shaft
have maximum input power limit specifications at
Massive couplings 6 Thru-Shaft, UNC a particular drive speed (RPM) and compensator
Foot mount installations * Available on Size 100 only. pressure setting (PSI) included with order. Power
controlled pumps that do not have input power
Shaft Option limit specifications, will be set at default setting
Code Code Thru-Shaft Variations (22.5 HP @ 1800 RPM and 3000 PSI) “H” & “C”
Size 33/38 Size 65/100 Omit No Thru-Shaft Option (60 HP @ 1800 RPM and 3000 PSI) “HM” & “CM”
Omit 7/8" Keyed SAE B 1¼" Keyed SAE C ** “M” may be remotely controlled;
Thru-Shaft, SAE AA Pilot, 9 Tooth 20/40 “ME” requires external pilot
A3
B 13T Spline SAE B 14T Spline SAE C Pitch Spline Coupling, PAVC 100 Only † Pumps with M, ME, AM, CM or HM controls will be
C* — 1½" Keyed SAE CC Thru-Shaft, SAE A Pilot, 9 Tooth 16/32 set to compensate at 207 bar (3000 PSI) unless
A4 Chart #1 specifies otherwise.
Pitch Spline Coupling, PAVC 100 Only
D* — 17T Spline SAE CC
* Size 100 only Thru-Shaft, SAE B Pilot, 13 Tooth 16/32 Code Painting
*B3
Pitch Spline Coupling, PAVC 100 Only
Omit No Paint
Outlet Port Thru-Shaft, SAE B Pilot, 15 Tooth 16/32
*B4 P Paint
Code Pitch Spline Coupling, PAVC 100 Only
Outlet Location Type
Thru-Shaft, SAE C Pilot, 14 Tooth 12/24
Omit Str. Thread Top SAE/Inch *C3 Code Multiple Pumps
Pitch Spline Coupling, PAVC 100 Only
3* Flange Top SAE/Inch I nlet port option “2” or “8” (top/bottom) must be used Omit Single Pump
* Size 100 only with all Thru-Shaft pumps. — Pump Factory Mounted on Rear
* Use SAE C-C shaft on thru-shaft pump variation
when combined input torque of front and rear
pumps exceeds 565 N•m (5000 In-Lbs).

Chart #1
Item Setting Ordering Notes
Unless otherwise specified, pump is shipped at
RPM — maximum GPM (1800 RPM) and set to 69 bar
(1000 PSI) [See † Exceptions].
PSI — When factory settings are required, the items
HP — shown in Chart #1 must be included with order.

GPM —

= Omit if not required or to select standard option coded “omit”.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 7
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Control Options Series PAVC 33/38/65/100

Pressure Compensated Control


Swash plate angle controls the output flow of the pump. compensator control setting, the control spool moves
Swash plate angle is controlled by the force generated up, bringing the pump to maximum displacement.
against the swash plate by the pumping pistons and by
the force of the servo piston. The force of the servo P Adjustment of PAVC Pumps
piston is greater than the force of the pumping pistons PROCEDURE:
when both are at the same pressure.
a. Standard Pressure Compensated Pump
By means of internal porting, pressure is connected from Pumps are shipped from factory with a differential
the output port to the servo piston via orifice (E), and to pressure of approximately 150 PSI (10 bar) on PAVC
the control spool via passage (D). Also pressure is 33/38/65, PAVC 100 is 300 PSI (21 bar) at 50% of
applied to the control spool chamber thru orifice (F). As maximum swash angle. Differential pressure will
long as the pressures at both ends of the control spool not normally change through the life of the pump. If
remain equal, the spool will remain offset upward, due to this control has been tampered with, a close
the added force of the spring. approximation of the correct setting can be made as
When pressure reaches the setting of the compensator follows:
control, the dart leaves its seat causing the pressure in Dead head the pump (no flow) with a 0-207 bar
the spool chamber to be reduced. The spool now moves (0-3000 PSI) gauge in the OUTLET (not the low signal
downward causing pressure in the servo piston cavity to “B” port), back the pressure compensator adjustment
vent via port “A”. The reduced pressure at the servo out (full counterclockwise).
piston allows the servo piston to move to the right. This
The gauge should read between 22-26 bar
movement reduces the angle of the swash plate and
(325-375 PSI) PAVC 33, 38 & 65, 34-40 bar (500-
thereby reduces the pumps output flow.
575 PSI) PAVC 100. If the gauge reads different
As pump pressure on the control spool drops below than this, turn the differential adjustment knob
pressure and spring force in the spool chamber, (Differential Option 4) or add/remove shims (Omit
the control spool moves upward to maintain an equilibrium Option) until correct pressure figure is reached.
on both sides of the spool. If pump pressure falls below

CONTROL OPTION - ‘OMIT’ (AT CONSTANT SPEED)

SWASHPLATE AIRBLEED VALVE


ASSEMBLY
FLOW

PISTON OUTLET

PRESSURE
INLET BARREL
D

PISTON

SERVO PISTON E CONTROL


SPOOL AND
SLEEVE

CONTROL DRAIN CONTROL SPOOL


PORT “A” SPRING CHAMBER

PRESSURE DIFFERENTIAL
COMPENSATOR ADJUSTMENT
ADJUSTMENT Parker Hannifin Corporation
Hydraulic Pump Division
8 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Control Options Series PAVC 33/38/65/100

Remote Pressure Control


Control Type (M)
Remote control of the PAVC output pressure can be Multiple Pressure Standby
achieved by controlling the pressure in the low signal “B” If the pressure level in the low signal “B” port is limited
port when the pump is set up for Control Type (M). A by a relief valve, as the desired pump outlet pressure is
manual, hydraulically piloted, electrical or electro- reached, the relief valve in the “B” port will allow the
proportionally controlled pressure control device is pump to standby at a preset pressure. Adding to this
installed in the line from the low signal “B” port to tank. concept, multiple, remotely piloted relief valves plumbed
The pump will then maintain pressure approximately in parallel in the “B” port line can yield multiple, sequential
equal to the pressure in the “B” port plus the pump pressure settings.
differential setting.

Low Pressure Standby


This option can be used as an alternative to the load
sensing option (A) to achieve low pressure standby.
Minimum standby pressure is somewhat higher than that
achieved using option (A). In the compensating mode
there is approximately 1.1 LPM (.3 GPM) flow from the
low signal “B” port in addition to 3.4 LPM (.9 GPM) flow
from the control drain port “A”.

CONTROL OPTION - ‘M’

(AT CONSTANT SPEED)


SWASHPLATE AIRBLEED VALVE
ASSEMBLY

FLOW

PISTON OUTLET
PRESSURE

INLET BARREL
D

PISTON

SERVO PISTON E CONTROL


SPOOL AND
SLEEVE

PORT “B”

CONTROL DRAIN CONTROL SPOOL


PORT “A” SPRING CHAMBER

PRESSURE DIFFERENTIAL
COMPENSATOR ADJUSTMENT
ADJUSTMENT
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio USA 9
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Control Options Series PAVC 33/38/65/100

Pressure & Flow Control (Load Sensing)


Control Type (A) Low Pressure Standby
This arrangement can also be used to provide low pressure
Flow control is achieved by placing an orifice (fixed or
standby by venting the “B” port through a simple on/off
adjustable) in the pump outlet port. The pressure drop
valve suitable for flows of 3.8-7.6 LPM (1-2 GPM). When
( P) across this flow control is the governing signal that
flow or pressure is required, this valve is closed allowing
controls the pump’s output, as explained below.
system pressure to build behind the control spool and
Whenever the pressure drop at the flow control increases bringing the pump on-stroke.
(indicating an increase in output flow), the pump attempts
to compensate by decreasing the output flow. It does this Load Sensing
by sensing the lower pressure on the downstream side of If, instead of measuring the pressure drop across the
the flow control via line (C), which is balanced against orifice in the pump outlet port, it is measured downstream
the pump pressure via passage (D), on the control spool. of a directional control valve, a constant pressure drop
The control spool is forced down against the control will be maintained across the valve spool. This results in
spool spring by differential pressure. This vents the a constant flow for any given opening of the directional
servo piston cavity, destroking the pump to a point where control valve regardless of the work load downstream or
the set pressure drop across the orifice is maintained the operating speed of the pump.
and the flow is obtained. The pump “senses” the amount of pressure necessary to
The converse of this is also true whenever the pressure move the load and adjusts output flow to match the valve
drop decreases (indicating a decrease in output flow). In opening selected and pressure to overcome the load
this case, the control spool is forced up. This increases plus the preset P across the valve spool.
pump displacement in an attempt to maintain the The benefits of this arrangement are that excellent,
predetermined pressure drop or constant flow. repeatable flow characteristics are achieved, and
It should be noted that the pump is still pressure considerable energy savings are realized while metering,
compensated and destrokes at the selected pressure compared to using a straight pressure compensated
setting. The pressure compensator control will override system.
the flow control whenever the pressure compensator
control setting is reached.

CONTROL OPTION - ‘A’


(AT CONSTANT SPEED)

SWASHPLATE AIRBLEED VALVE FLOW CONTROL


ASSEMBLY ADJUSTMENT
FLOW

PISTON SYSTEM PRESSURE

INLET BARREL
D PRESSURE

PISTON

C
SERVO PISTON E CONTROL
SPOOL
AND
SLEEVE

SIGNAL LINE

PORT “B”
F

CONTROL DRAIN CONTROL SPOOL


PORT “A” SPRING CHAMBER

PRESSURE COMPENSATOR DIFFERENTIAL


ADJUSTMENT ADJUSTMENT

Parker Hannifin Corporation


Hydraulic Pump Division
10 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Control Options Series PAVC 33/38/65/100

Pressure & Power (Torque) Control


Control Type (H)
The power control is sensitive to the position of the spool to move downward, venting the servo piston cavity
servo piston. When the servo piston is to the right, the and causing the servo piston to move to the right. This
swash plate causes low flow and the power control reduces output flow and thereby power.
piston develops maximum spring pressure on its
As indicated in the pictorial drawing, pressure in
companion poppet (mechanical feedback). When the
the control spool chamber is affected by both the pressure
servo piston is left and the flow is high, the power control
compensator control and the power control. The resultant
piston reduces spring pressure on the poppet. This
pressure in this chamber is a function of the set points of
allows it to open under less pressure in the control spool
these two controls. Both set points are adjustable.
chamber, thereby venting some of the pressure in the
control spool chamber. As with the operation of the
pressure compensator control, this allows the control

(AT CONSTANT SPEED)


FLOW
CONTROL OPTION - ‘H’
SWASHPLATE AIRBLEED VALVE
ASSEMBLY
PRESSURE

PISTON OUTLET

INLET BARREL
D

PISTON

SERVO PISTON E CONTROL


SPOOL AND
SLEEVE
POWER
CONTROL
PISTON

CONTROL DRAIN CONTROL SPOOL


PORT “A” SPRING CHAMBER

POWER (TORQUE) PRESSURE DIFFERENTIAL


ADJUSTMENT COMPENSATOR ADJUSTMENT
ADJUSTMENT

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 11
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Control Options Series PAVC

Pressure, Power & Flow Control


Control Type (C)
In addition to the three control configurations just
discussed, it is possible to combine all three control
devices in one pump. In this mode, the position of
the control spool is a function of the actions of the
pressure compensator adjustment, power adjustment,
and flow control.

(AT CONSTANT SPEED)


FLOW
PRESSURE

CONTROL OPTION - ‘C’


SWASHPLATE AIRBLEED VALVE FLOW CONTROL
ASSEMBLY ADJUSTMENT

PISTON SYSTEM PRESSURE

INLET BARREL
D

PISTON

C
SERVO PISTON E CONTROL
SPOOL
AND
SLEEVE
POWER
CONTROL SIGNAL LINE
PISTON
PORT “B”
F

CONTROL DRAIN CONTROL SPOOL


PORT “A” SPRING CHAMBER

POWER (TORQUE) PRESSURE DIFFERENTIAL


ADJUSTMENT COMPENSATOR ADJUSTMENT
ADJUSTMENT

Parker Hannifin Corporation


Hydraulic Pump Division
12 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Technical Information Series PAVC 33/38/65/100

How to read input power control curve data.

1800 RPM
FLOW KW HP
18.6 (25)
N·m In-Lbs
90.4 (800)
LPM GPM
60.6 (16) 14.9 (20)

53.0 (14)

Input Power
67.8 (600)

Input Torque
45.4 (12) 11.2 (15)
Flow

37.9 (10)
45.2 (400)
30.3 (8) 7.5 (10)
22.7 (6)
22.6 (200)
15.1 (4) 3.7 (5)
7.6 (2)
0 (0) 0 (0) 0 (0)
Bar 0 69 138 207
PSI (0) (1000) (2000) (3000)
Pressure
POWER

1. Power “A” curve corresponds to flow “A” curve. This represents a particular
setting of the power (torque) control.

2. With this setting the maximum power required will be as shown


at the apex (maximum point) of the power curve.

3. The flow at this setting will follow the flow vs. pressure curve shown.

4. Example – 1800 RPM, curve labeled “C”:


A. Flow will follow curve “C” and pump will deadhead at 190 bar (2750 PSI).
B. Full flow will not be realized above 83 bar (1200 PSI).
C. Flow at 103 bar (1500 PSI) will be approximately 48.1 LPM (12.7 GPM).
D. Maximum power [11 KW (15 HP)] occurs at approximately 117 bar (1700 PSI).

5. Torque values are shown to correspond to powers at speed shown.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 13
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Technical Information Series PAVC 33/38

Performance Information
Series PAVC 33/38 Pressure Compensated,
Variable Volume, Piston Pumps

Features
• High Strength Cast-Iron Housing
• Built-In Supercharger
• High Speed Capability – 3000 RPM
• Two Piece Design for Ease of Service
• Cartridge Type Controls ­– Field Changeable
• Replaceable Bronze Clad Port Plate
• Airbleed Standard for Quick Priming
• Hydrodynamic Cylinder Barrel Bearing
• Full Pressure Rating on Water Glycol Fluids Specifications
• Filtered and/or Cooled Drain Line Capable Pressure Ratings:
7 bar (100 PSI) Maximum
Outlet Port: 207 bar (3000 PSI) Continuous (P1)
248 bar (3600 PSI) Peak (P3)
Controls
• Pressure Compensation Inlet Port: 1.72 bar (25 PSI) Maximum
• Remote Pressure Compensation 0.17 bar (5 In. Hg.) Minimum
@ 1800 RPM (See Inlet Chart for
• Load Sensing
other speeds)
• Power (Torque) Limiting
• Power Limiting and Load Sensing Control Drain: 7 bar (100 PSI) Maximum
• Adjustable Maximum Volume Stop Speed Ratings: 600 to 3000 RPM
• Low Pressure Standby
Operating Temperature Range: – 40°C to 71°C
(– 40°F to 160°F)
Schematic Symbol
(Basic Pump) Housing Material: Cast-Iron
Filtration: Maintain SAE Class 4, ISO 16/13,
ISO 18/15 Maximum Recommended
Mounting: SAE B 2-Bolt Flange Mount or Diagonally
Weight and Package Size on SAE B 4-Bolt Flange Mount.

Weight
Length From
Height Height Installation Data: See page A46 of this catalog for
Mounting specific recommendations pertaining to system
Model In in CM in CM
Kg (Lb) Face in CM (Inches) (Inches)
(Inches)
cleanliness, fluids, start-up, inlet conditions, shaft
alignment, drain line restrictions and other important
PAVC 33/38 18 (40) 18.41 (7.25) 16.00 (6.30) 16.81 (6.62)
factors relative to the proper installation and use of
these pumps.
Quick Reference Data Chart
Pump Delivery *Approx. Noise Levels dB(A) Input Power At
Displacement @ 21 bar (300 PSI) @ Full Flow 1800 RPM (1200 RPM) 1800 RPM, Max.
Pump Model CM3/REV in LPM (GPM) 34 bar 69 bar 138 bar 207 bar Displacement &
(IN3/REV)
1200 RPM 1800 RPM (500 PSI) (1000 PSI) (2000 PSI) (3000 PSI) 207 bar (3000 PSI)

PAVC33 33 (2.0) 39.4 (10.4) 59.0 (15.6) 75 (69) 76 (72) 78 (75) 79 (77) 21.3 kw (28.5 hp)
PAVC38 38 (2.3) 45.0 (11.9) 67.8 (17.9) 75 (69) 76 (72) 78 (75) 79 (77) 24.6 kw (33.0 hp)
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the
field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured
and recorded in accordance with applicable ISO and NFPA standards.

Parker Hannifin Corporation


Hydraulic Pump Division
14 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Performance Data Series PAVC 33/38

Typical Performance Data - Fluid: Standard Hydraulic Oil 100 SSU @ 49°C (120°F)
PAVC33 @ 1800 RPM PAVC38 @ 1800 RPM
LPM GPM Volumetric Efficiency LPM GPM Volumetric Efficiency
100 113.6 (30) 100 113.6 (30)
Efficiency - %

Efficiency - %
Overall Efficiency iency
Effic
90 102.2 (27) 90 102.2 (27)
all
Over
80 90.9 (24) 80 90.9 (24)
KW HP KW HP
70 79.5 (21) 26.1 (35.0) 70 79.5 (21) 26.1 (35.0)

60 68.1 (18) 22.4 (30.0) 60 68.1 (18) Flow 22.4 (30.0)

Flow
Flow

Flow
57.8 (15) 18.6 (25.0) 57.8 (15) 18.6 (25.0)

45.4 (12) 14.9 (20.0) 45.4 (12) r 14.9 (20.0)


r we w
o we w o
t P Fl o
o pu ll
34.1 (9) 11.2 (15.0) 34.1 (9) 11.2 (15.0)

Power

Power
t P Fl In t Fu
pu ll
22.7 (6) In t Fu 7.5 (10.0) 22.7 (6)
a 7.5 (10.0)
a
sate d Power wer
11.4 (3)
Compen
3.7 (5.0) 11.4 (3) sated Po 3.7 (5.0)
Compen
0 (0) 0 (0) 0 (0) 0 (0)
Bar 0 69 138 207 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000) PSI (0) (1000) (2000) (3000)
Pressure Pressure

NOTE: The efficiencies and data in the graph are good only WHERE:
for pumps running at 1800 RPM and stroked to maximum. To Q = Actual Output Flow in GPM
calculate approximate input power for the other conditions, use PSI = Pressure At Pump Outlet
the following formula:
CHp = Input Power @ Full Compensation

[
HP = Q x (PSI)
1714 ] + (CHp) @ 1800 RPM (from graph read at
operating pressure)

Actual GPM is directly proportional to drive speed and


maximum volume setting. Flow loss, however, is a function
of pressure only.

Compensated Control
Inlet Characteristics at Full Displacement Drain Flow @ 1800 RPM
bar PSI (Graph only valid at sea level) LPM GPM
.41 (6) 5.7 (1.5)
Recommended
.28 (4)
Operating Condition 4.5 (1.2)
.14 (2)
Inlet Pressure

Drain Flow

bar In-Hg 3.4 (.9)


0 (0)

.17 (5) 2.3 (.6)


Vacuum

.34 (10)
DO NOT OPERATE
.51 (15) IN THIS REGION 1.1 (.3)

.68 (20) 0 (0)


0 500 1000 1500 2000 2500 3000 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000)
Shaft Speed - RPM
System Pressure

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 15
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Performance Data Series PAVC 33/38

Typical Performance Data -

Minimum Power Settings Attainable


With Control Options C, H, CM & HM

PAVC33
KW HP
22.4 (30) 207 bar (3000 PSI)
Comp. Setting PAVC33
Flow vs. Shaft Speed

Outlet Flow @ Max. Displacement


17.9 (24) LPM GPM
172 bar (2500 PSI) 151.5 (40.0)
Comp. Setting

13.4 (18)
113.6 (30.0)
Power

138 bar (2000 PSI)


Comp. Setting
8.9 (12) Full Flow Boundary
75.7 (20.0)
103 bar (1500 PSI)
Comp. Setting
4.5 (6) 69 bar (1000 PSI) 37.9 (10.0)
Comp. Setting

0 (0) 0 (0)
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000

Shaft Speed - RPM Shaft Speed - RPM

NOTE: Minimum attainable HP setting means that input Determine maximum input power limitation at desired RPM.
power will not exceed the indicated setting at the indicated All points above desired compensator setting curve can be
RPM and that the pump will achieve full compensator achieved.
pressure selected. If setting input power limiter below full
flow boundary, full flow may not be obtained at low operating
pressure.

Power (Torque) Limiting Curves

PAVC33 PAVC33
@ 1200 RPM @ 1800 RPM
LPM GPM KW HP LPM GPM KW HP
60.6 (16) 14.9 (20) 75.7 (20) 18.6 (25) N·m In-Lbs
N·m In-Lbs
90.4 (800) 68.1 (18) 90.4 (800)
53.0 (14)
60.6 (16) 14.9 (20)
45.2 (12) 11.2 (15)
53.0 (14) 67.8 (600)
Input Power
Input Power

67.8 (600) Input Torque


Input Torque

37.8 (10)
45.2 (12) 11.2 (15)
Flow

Flow

30.3 (8) 7.5 (10) 37.8 (10)


45.2 (400) 45.2 (400)
30.3 (8) 7.5 (10)
22.7 (6)
22.7 (6)
15.1 (4) 3.7 (5) 22.6 (200) 22.6 (200)
15.1 (4) 3.7 (5)
7.6 (2) 7.6 (2)
0 (0) 0 (0) 0 (0) 0 (0) 0 (0) 0 (0)
Bar 0 69 138 207 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000) PSI (0) (1000) (2000) (3000)
Pressure Pressure

See page 12 for “How to Read Curves” information.

Parker Hannifin Corporation


Hydraulic Pump Division
16 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Performance Data Series PAVC 33/38

Typical Performance Data -

Minimum Power Settings Attainable


With Control Options C, H, CM & HM

PAVC38
KW HP
22.4 (30) 207 bar (3000 PSI)
Comp. Setting PAVC38
Flow vs. Shaft Speed

Outlet Flow @ Max. Displacement


17.9 (24) LPM GPM
172 bar (2500 PSI) 151.5 (40)
Comp. Setting

13.4 (18)
138 bar (2000 PSI) 113.6 (30)
Power

Comp. Setting
Full Flow Boundary
8.9 (12) 103 bar (1500 PSI) 75.7 (20)
Comp. Setting

4.5 (6) 69 bar (1000 PSI)


Comp. Setting 37.9 (10)

0 (0) 0 (0)
0 500 1000 1500 2000 2500 3000 0 500 1000 1500 2000 2500 3000

Shaft Speed - RPM Shaft Speed - RPM

NOTE: Minimum attainable HP setting means that input Determine maximum input power limitation at desired RPM.
horsepower will not exceed the indicated setting at the indicated All points above desired compensator setting curve can be
RPM and that the pump will achieve full achieved.
compensator pressure selected. If setting input power limiter
below full flow boundary, full flow may not be obtained at low
operating pressure.

Power (Torque) Limiting Curves

PAVC38 PAVC38
@ 1200 RPM @ 1800 RPM
LPM GPM KW HP LPM GPM KW HP
60.6 (16) 14.9 (20) 75.7 (20) 29.8 (40)
N·m In-Lbs
N·m In-Lbs
53.0 (14) 90.4 (800) 26.1 (35) 135.6 (1200)

45.2 (12) 11.2 (15) 56.8 (15) 22.4 (30)


113.0 (1000)
Input Power

Input Power

67.8 (600)
Input Torque

37.8 18.6 (25)


Input Torque
(10)
90.4 (800)
Flow
Flow

30.3 (8) 7.5 (10) 37.8 (10) 14.9 (20)


45.2 (400) 67.8 (600)
22.7 (6) 11.2 (15)
45.2 (400)
15.1 (4) 3.7 (5) 18.9 (5) 7.5 (10)
22.6 (200)
3.7 (5) 22.6 (200)
7.6 (2)

0 (0) 0 (0) 0 (0) 0 (0) 0 (0) 0 (0)


Bar 0 69 138 207 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000) PSI (0) (1000) (2000) (3000)
Pressure Pressure

See page 12 for “How to Read Curves” information.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 17
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 33/38

Rear Ported Pump Dimensions


* Inch equivalents for millimeter dimensions are shown in (**).

NOTE:
1. Pump shown and dimensioned is a clockwise rotation pump. Outlet
port, A and B ports, and controls will be on opposite side for a
counterclockwise rotation pump.
63.50
(2.50)
INLET PORT 25.40 VENT & FILL PLUG
1-5/8-12UN-2B ST. THREAD OUTLET PORT (1.00)
O-RING SAE-20 1-1/16-12UN-2B
ST. THREAD
O-RING SAE-12
63.50
(2.50) 25.40
SHAFT OPTION (1.00)
31.75 “OMIT”
(1.25) SAE “B” SHAFT
7/8" KEYED
VARIABLE VOLUME PUMP

MAX. TORQUE 31.75


74.68 = 209 N·m (1.25)
CC/REV ROTATION

PSI MAX

INITIAL FACTORY SETTINGS BELOW

HP RPM
(2.94) (1,850 IN-LBS)
GPM

PSI

96.77
HYDRAULIC PUMP/MOTOR DIVISION
OTSEGO,MICH. 49078 USA

(3.81)
LOW SIGNAL PORT “B”
7/16-20UNF-2B
ST. THREAD O-RING
SAE-4 12.70
(.50)
98.55
(3.88) 20.57
(.81) TORQUE CONTROL ADJUSTMENT:
56 N·m (500 IN-LB) PER TURN
Rear View Top View PRESSURE COMPENSATOR
ADJUSTMENT: 55 BAR (800 PSI)
PER TURN
CLEARANCE FOR .500 DIA.
MOUNTING BOLTS. SAE “B”
84.07 84.07 2-BOLT PATTERN
(3.31) (3.31) 58.67 184.15
CLEARANCE FOR (2.31) (7.25)
72.89 72.89 .500 DIA. BOLTS
(2.87) (2.87) MOUNTED DIAGONALLY OPTIONAL LOW ROTATION
63.50 63.50 ON SAE “B” 9.39 SIGNAL PORT ARROW
(2.50) (2.50) 4-BOLT PATTERN (.37) (PORT “B”)
6.35 (.250)
WIDE KEY B
14.224
(.560) 25.09 (.988)
14.986 24.73 (.974) 41.40
(.590) 101.60 (1.63)
(4.000)
Ø 101.54
(3.998) 44.45
22.22 (.875)
Ø 22.19 (.874) (1.75)
74.68
(2.94)
NON-ADJUSTABLE CONTROL DRAIN A
18.79 DIFFERENTIAL PORT “A”
(.74) OPTION “OMIT” 7/16-20UNF-2B
ST. THREAD
O-RING SAE-4 25.40
65.28 35˚ ADJUSTABLE 27.69
DIFFERENTIAL (1.00)
(2.57) (1.09)
OPTION “4” 52.32
(2.06) MAX
AIRBLEED DRAIN PORT
7/16-20UNF-2B SENSITIVITY: 41.15 74.68
ST. THREAD O-RING 13.8 BAR (200 PSI) (1.62) (2.94)
SAE-4 PER TURN
115.06
(4.53) Side View
MAX.VOLUME STOP
OPTION “2”
SHAFT OPTION “S” 2.2 CC/REV/TURN (PAVC33)
SAE “B” SHORT SHAFT 2.5 CC/REV/TURN (PAVC38)
Front View 7/8" KEYED
MAX. TORQUE =
209 N·m (1,850 IN-LBS)

61.97
SHAFT OPTION “B” (2.44)
SAE “B” SPLINED SHAFT MAX
13 TOOTH MAX.VOLUME STOP
16/32 PITCH OPTION “5”
MAX. TORQUE = 2.5 CC/REV/TURN (PAVC33)
209 N·m (1,850 IN-LBS) 2.8 CC/REV/TURN (PAVC38)

Parker Hannifin Corporation


Hydraulic Pump Division
18 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 33/38

Side Ported – Dimensions Port Location


* Inch equivalents for millimeter dimensions Option Outlet Port Inlet Port Control Drain Signal Port
are shown in (**).
SAE-12 1-1/4 SAE 4-Bolt Flange SAE-4 SAE-4
2 Straight Thread 7/16-14UNC Threads Standard Straight Thread Straight Thread
NOTE:
(1-1/16-12UNC) Pressure Series (Code 61) (7/16-20UNF) (7/16-20UNF)
1. Shown and dimensioned is a clockwise
pump. Ports A and B, delivery port and
pump controls will be on the opposite
side for a counterclockwise pump. 63.50 VENT & FILL PLUG
(2.50)
25.40
105.92 89.66 (1.00)
(4.17) (3.53) OUTLET PORT
SEE CHART
FOR SIZE

25.40
VARIABLE VOLUME PUMP

63.50 (1.00)
CC/REV ROTATION

PSI MAX

(2.50)
INITIAL FACTORY SETTINGS BELOW

SHAFT OPTION
HP RPM

GPM

“OMIT”
PSI

HYDRAULIC PUMP/MOTOR DIVISION


OTSEGO,MICH. 49078 USA

SAE “B” SHAFT


7/8" KEYED
MAX. TORQUE 31.75
= 209 N·m (1.25)
74.67 (1,850 IN-LBS)
(2.94)
LOW SIGNAL
PORT “B”
104.65 SEE CHART
(4.12) FOR SIZE
12.70
(.50)
20.57 TORQUE CONTROL ADJUSTMENT:
(.81) 56 N·m (500 IN-LB) PER TURN
Rear View CLEARANCE FOR .500 DIA.
MOUNTING BOLTS. SAE “B” PRESSURE COMPENSATOR ADJUSTMENT:
2-BOLT PATTERN 55 BAR (800 PSI) PER TURN
89.41 89.66 CLEARANCE FOR
(3.52) (3.53) INLET PORT SAME
.500 DIA. BOLTS Top View BOTH SIDES
72.89 72.89 MOUNTED DIAGONALLY SEE CHART FOR SIZE
(2.87) (2.87) ON SAE “B” 4-BOLT 58.67 185.93
PATTERN (2.31) (7.32)
63.50 63.50 89.66
(2.50) (2.50) 9.37
6.35 (.250) (.37) (3.53)
WIDE KEY

25.09 (.988)
14.22 (.56) 24.73 (.974)
14.98 (.59)
101.60
(4.000)
Ø 101.54
(3.998)
63.50
74.68 22.22 (.875) (2.50)
Ø 22.19 (.874)
(2.94)

58.93
NON-ADJUSTABLE (2.32)
DIFFERENTIAL
OPTION “OMIT”
65.28 35˚
(2.57) 18.79 CONTROL DRAIN
PORT “A” 52.32 30.23 27.69
(.74) 25.40 (1.19)
AIRBLEED DRAIN PORT SEE CHART (1.00) (2.06) (1.09)
7/16-20 UNF-2B FOR SIZE 74.68 (2.94) MAX
ST. THREAD O-RING 144.53
SAE-4 41.15
(1.62) (5.69)
OPTION “8”
ISO 6149-4
ADAPTER FITTING
Side View
ADJUSTABLE
ON OPTION “8” DIFFERENTIAL
SHAFT OPTION “S” MAX.VOLUME STOP OPTION “2”
Front View OPTION “4” 2.2 CC/REV/TURN (PAVC33)
SAE “B” SHORT SHAFT
SENSITIVITY: 7/8" KEYED 2.5 CC/REV/TURN (PAVC38)
115.06 13.8 BAR (200 PSI) MAX. TORQUE =
(4.53) PER TURN 209 N·m
(1,850 IN-LBS)

SHAFT OPTION “B”


SAE “B” SPLINED SHAFT 61.97
13 TOOTH (2.44)
16/32 PITCH MAX
MAX. TORQUE = MAX.VOLUME STOP OPTION “5”
209 N·m 2.5 CC/REV/TURN (PAVC33)
(1,850 IN-LBS) 2.8 CC/REV/TURN (PAVC38)

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 19
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Technical Information Series PAVC 65

Performance Information
Series PAVC65 Pressure Compensated,
Variable Volume, Piston Pump

Features
• High Strength Cast-Iron Housing
• Built-In Supercharger
• High Speed Capability - 3000 RPM
• Two Piece Housing for Ease of Service
• Cartridge Type Controls - Field Changeable
• Replaceable Bronze Clad Port Plate
• Airbleed Standard for Quick Priming
• Hydrodynamic Cylinder Barrel Bearing
• Full Pressure Rating on Water Glycol Fluids
• Filtered and/or Cooled Drain Line Capable - Specifications
7 bar (100 PSI) Maximum Pressure Ratings:
Outlet Port: 207 bar (3000 PSI) Continuous (P1)
Controls 248 bar (3600 PSI) Peak (P3)
• Pressure Compensation Inlet Port: 1.7 bar (25 PSI) Maximum
• Remote Pressure Compensation 0.17 bar (5 In. Hg.) Minimum
• Load Sensing @ 1800 RPM (See Inlet Chart for
• Power (Torque) Limiting other speeds)
• Power Limiting and Load Sensing Control Drain: 7 bar (100 PSI) Maximum
• Adjustable Maximum Volume Stop Speed Ratings: 600 to 3000 RPM*
• Low Pressure Standby * See Inlet Characteristics Chart on page A155 and
consider using Dual Inlet Port configuration on
page A178 for applications above 2700 RPM.
Schematic Symbol
(Basic Pump) Operating Temperature Range: – 40°C to 71°C
(– 40°F to 160°F)
Housing Material: Cast-Iron
Filtration: Maintain SAE Class 4, ISO 16/13,
ISO 18/15 Maximum Recommended
Mounting: SAE C 2-Bolt Flange Mount or Diagonally
Weight and Package Size on SAE C 4-Bolt Flange Mount
Length From
Weight
Mounting
Height Height Installation Data: See page A46 of this catalog for
Model In in CM in CM specific recommendations pertaining to system
Kg (Lb) Face in CM (Inches) (Inches)
(Inches) cleanliness, fluids, start-up, inlet conditions, shaft
PAVC65 28 (62) 22.40 (8.82) 18.84 (7.42) 20.32 (8.00) alignment, drain line restrictions and other important
factors relative to the proper installation and use of
these pumps.
Quick Reference Data Chart
Pump Delivery *Approx. Noise Levels dB(A) Input Power At
Displacement @ 21 bar (300 PSI) @ Full Flow 1800 RPM (1200 RPM) 1800 RPM, Max.
Pump Model CM3/REV in LPM (GPM) 34 bar 69 bar 138 bar 207 bar Displacement &
(IN3/REV)
1200 RPM 1800 RPM (500 PSI) (1000 PSI) (2000 PSI) (3000 PSI) 207 bar (3000 PSI)

PAVC65 65 (4.0) 78.7 (20.8) 118.1 (31.2) 77 (75) 78 (76) 80 (78) 81 (79) 43.1 kw (57.8 hp)
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the
field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured
and recorded in accordance with applicable ISO and NFPA standards.

Parker Hannifin Corporation


Hydraulic Pump Division
20 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Performance Data Series PAVC 65

Typical Performance Data - Fluid: Standard Hydraulic Oil 100 SSU @ 49°C (120°F)

PAVC65 @ 1200 RPM PAVC65 @ 1800 RPM


LPM GPM Volumetric Efficiency LPM GPM Volumetric Efficiency
100 113.6 (30) 100 151.4 (40)
Efficiency - %

Efficiency - %
Overall Efficiency y
Efficienc
90 102.2 (27) 90 136.3 (36)
KW HP Overall KW HP
80 90.9 (24) 29.8 (40) 80 121.1 (32) Flow 59.7 (80)

70 79.5 (21) Flow 26.1 (35) 70 106.0 (28) 52.2 (70)

60 68.1 (18) 22.4 (30) 60 90.6 (24) 44.7 (60)


Flow

Flow

Input Power
Input Power
57.8 (15) 18.6 (25) 75.7 (20) 37.1 (50)

45.4 (12) 14.9 (20) 60.6 (16) 29.8 (40)


er
Fl er

ow ow
ll ow
ow

P
t Fl
Fu P

34.1 (9) 11.2 (15) 45.4 (12) 22.4 (30)


pu ull
at put

n
I tF
In

22.7 (6) 7.5 (10) 30.3 (8) a 14.9 (20)

wer
sated Po
11.4 (3) 3.7 (5) 15.1 (4) 7.5 (10)
Compen Power
Compensated
0 (0) 0 (0) 0 (0) 0 (0)
Bar 0 69 138 207 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000) PSI (0) (1000) (2000) (3000)
Pressure Pressure

NOTE: The efficiencies and data in the graph are good only WHERE:
for pumps running at 1800 RPM and stroked to maximum. To Q = Actual Output Flow in GPM
calculate approximate input power for the other conditions, use PSI = Pressure At Pump Outlet
the following formula:
CHp = Input Power @ Full Compensation

[
HP = Q x (PSI)
1714 ] + (CHp) @ 1800 RPM (from graph read at
operating pressure)

Actual GPM is directly proportional to drive speed and


maximum volume setting. Flow loss, however, is a function
of pressure only.

Compensated Control
Inlet Characteristics at Full Displacement Drain Flow @ 1800 RPM
bar PSI (Graph only valid at sea level) LPM GPM
.41 (6) 7.6 (2.0)

Recommended
.28 (4)
Operating Condition
5.7 (1.5)
.14 (2)
Inlet Pressure

Drain Flow

bar In-Hg
0 (0)
3.8 (1.0)
.17 (5)
Vacuum

.34 (10)
DO NOT OPERATE 1.9 (.5)

.51 (15) IN THIS REGION


.68 (20) 0 (0)
0 500 1000 1500 2000 2500 3000 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000)
Shaft Speed - RPM
System Pressure

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 21
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Performance Data Series PAVC 65

Typical Performance Data -

Minimum Power Settings Attainable


With Control Options C, H, CM & HM

PAVC65
KW HP
44.7 (60)
PAVC65
207 bar (3000 PSI)
Flow vs. Shaft Speed

Outlet Flow @ Max. Displacement


Comp. Setting
35.8 (48) LPM GPM
227.4 (60)
172 bar (2500 PSI)
Comp. Setting
26.8 (36)
Power

170.3 (45)
138 bar (2000 PSI)
Comp. Setting
17.9 (24) 103 bar (1500 PSI)
Comp. Setting 113.6 (30)
69 bar (1000 PSI)
Comp. Setting
8.9 (12) 56.8 (15)

0 (0) 0 (0)
0 600 1200 1800 2400 3000 0 500 1000 1500 2000 2500 3000

Shaft Speed - RPM Shaft Speed - RPM

NOTE: Minimum attainable HP setting means that input Determine maximum input power limitation at desired RPM.
power will not exceed the indicated setting at the indicated All points above desired compensator setting curve can be
RPM and that the pump will achieve full compensator achieved.
pressure selected. If setting input power limiter below full
flow boundary, full flow may not be obtained at low operating
pressure.

PAVC65 PAVC65
@ 1200 RPM Power (Torque) Limiting Curves
@ 1800 RPM
LPM GPM KW HP LPM GPM KW HP
33.6 (45) 132.5 (35) 52.2 (70)
N·m In-Lbs N·m In-Lbs
75.7 (20) 29.8 (40)
113.6 (30) 44.7 (60) 226.0 (2000)
226.0 (2000)
26.1 (35)
94.6 (25) 37.3 (50)
56.8 (15) 22.4 (30) 226.0 (1600)
Input Power
Input Power

Input Torque
169.5 (1500)
Input Torque

18.6 (25) 75.7 (20) 29.8 (40)


Flow

Flow

169.5 (1200)
37.9 (10) 14.9 (20)
56.8 (15) 22.4 (30)
113.0 (1000)
11.2 (15) 113.0 (800)
37.9 (10) 14.9 (20)
18.9 (5) 7.5 (10)
56.5 (500)
56.5 (400) 18.9 (5) 7.5 (10)
3.7 (5)

0 (0) 0 (0) 0 (0) 0 (0) 0 (0) 0 (0)


Bar 0 69 138 207 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000) PSI (0) (1000) (2000) (3000)
Pressure Pressure

See page 12 for “How to Read Curves” information.

Parker Hannifin Corporation


Hydraulic Pump Division
22 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 65

Dimensions – Rear Port


* Inch equivalents for millimeter dimensions are shown in (**).

Notes:
1. Pump shown and dimensioned is a clockwise rotation pump. Outlet port, A and B ports, and controls
will be on opposite side for a counterclockwise rotation pump.
2. Pump mounting and shaft comply with SAE “C” dimensions. 81.03
(3.19)
INLET PORT
1-7/8-12UN-2B 31.75
OUTLET PORT (1.25)
ST. THREAD O-RING 1-5/16-12UN-2B
SAE-24 ST. THREAD O-RING
SAE-16

38.10
(1.50) 25.40
88.90 (1.00)
(3.50)
SHAFT OPTION
“OMIT”
SAE “C” SHAFT
1-1/4" KEYED
MAX. TORQUE
= 641 N·m

ROTATION

RPM
(5,680 IN-LBS)

VARIABLE VOLUME PUMP

HYDRAULIC PUMP/MOTOR DIVISION


Otsego, MI 49078 MADE IN USA
88.90

INITIAL FACTORY SETTINGS BELOW

@
31.75

PSI MAX
CC/REV

PSI
(3.50)

GPM
115.82

HP
(1.25)
(4.56)
“PORT B” LOW SIGNAL
7/16-20UNF-2B
ST. THREAD O-RING
SAE-4 VENT/FILL PLUG

Rear View 15.75


TORQUE CONTROL ADJUSTMENT
(.62)
SENSITIVITY: 90 N·m (800 IN-LB)
101.60 101.60 CLEARANCE FOR Top View PER TURN
(4.00) (4.00) .625 DIA. MOUNTING
BOLTS. SAE “C” PRESSURE COMPENSATOR ADJUSTMENT
2-BOLT PATTERN SENSITIVITY: 55 BAR (800 PSI) PER TURN
90.42 90.42
(3.56) (3.56) CLEARANCE FOR
.500 DIA. BOLTS 55.63
MOUNTED DIAGONALLY 224.03
(2.19) (8.82)
81.03 81.03 ON SAE “C”
(3.19) (3.19) 4-BOLT PATTERN 12.45 31.75
(.49) (1.25)
7.925 (.312)
WIDE KEY

35.33 (1.391)
70.61 35.07 (1.381) B
(2.78) 50.80
(2.00)
127.00
(5.000)
ø 126.94
52.32 (4.998)
(2.06)
ø 31.75 (1.250)
31.69 (1.248)

23.37
(.92) “PORT A” CONTROL DRAIN
9/16-18UNF-2B
ST. THREAD O-RING
SAE-6
31.75 63.50
65.28 35˚ (1.25) (2.50)
(2.57) ADJUSTABLE
DIFFERENTIAL 95.25
OPTION “4” (3.75)
AIRBLEED DRAIN PORT SENSITVITY: 13.8 BAR 219.20
7/16-20UNF-2B 115.06 (200 PSI) PER TURN (8.63)
ST. THREAD O-RING (4.53)
SAE-4 Side View
Front View

SHAFT OPTION “B”


14 TOOTH OPTION “5” OPTION “2”
SAE “C” SPLINE VOLUME STOP VOLUME STOP
12/24 PITCH SENSITIVITY: SENSITIVITY:
MAX TORQUE = 83.82 4.2 CC/REV/TURN 27.68 3.8 CC/REV/TURN
641 N·m 55.63 (3.30) (1.09)
(5,680 IN-LBS) (2.19) MAX MAX

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 23
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 65

Dimensions – Top Port Port Location


* Inch equivalents for millimeter dimensions are Option Outlet Port Inlet Port Control Drain Signal Port
shown in (**).
SAE-16 1-1/2 SAE 4-Bolt Flange SAE-6 SAE-4
NoteS: 2 Straight Thread 1/2-13UNC Threads Standard Straight Thread Straight Thread
(1-5/16-12UNC) Pressure Series (Code 61) (9/16-18UNF) (7/16-20UNF)
1. Pump shown and dimensioned is a
clockwise rotation pump. Outlet port,
A and B ports, and controls will be on
opposite side for a counterclockwise
pump. 192.02
(7.56)
2. Pump mounting and shaft comply with 81.03
(3.19)
SAE “C” dimensions. 31.75 35.81
OUTLET PORT (1.41)
SEE CHART (1.25) INLET PORT
FOR SIZE SEE CHART
FOR SIZE

25.40
85.85 (1.00)
(3.38)
SHAFT OPTION
“OMIT”
SAE “C” SHAFT
1-1/4" KEYED 69.85
MAX. TORQUE = (2.75)
641 N·m

ROTATION

RPM
(5,680 IN-LBS)

VARIABLE VOLUME PUMP

HYDRAULIC PUMP/MOTOR DIVISION


Otsego, MI 49078 MADE IN USA
88.90

INITIAL FACTORY SETTINGS BELOW


31.75

@
PSI MAX
CC/REV
115.82

PSI
(3.50)

GPM
HP
(4.56) (1.25)

SIGNAL PORT
“PORT B”
SEE CHART VENT/FILL PLUG
FOR SIZE
TORQUE CONTROL ADJUSTMENT
SENSITIVITY: 90 N·m (800 IN-LB)
Rear View CLEARANCE FOR 15.74
(.62) PER TURN
.625 DIA. MOUNTING
BOLTS. SAE “C” PRESSURE COMPENSATOR ADJUSTMENT
101.60 101.60 2-BOLT PATTERN Top View SENSITIVITY: 55 BAR (800 PSI) PER TURN
(4.00) (4.00)
CLEARANCE FOR
90.42 90.42 .500 DIA. BOLTS
(3.56) (3.56) MOUNTED DIAGONALLY 55.62 224.02
ON SAE “C” (2.19) (8.82)
81.02 81.02 4-BOLT PATTERN
(3.19) (3.19) 12.44 31.75
(.49) (1.25)
7.925 (.312)
WIDE KEY

70.61 35.33 (1.391)


(2.78) 35.07 (1.381) B 50.80
(2.00)

52.32
(2.06) 31.75 (1.250)
Ø 31.69 (1.248)

Ø 127.00 (5.000) A
126.94 (4.998)
23.36
(.92)
CONTROL DRAIN PORT
SEE CHART FOR SIZE 63.50 SECONDARY
31.75 VENT/FILL
(1.25) (2.50)
65.27 35˚
(2.57) ADJUSTABLE 95.25
DIFFERENTIAL (3.75)
OPTION “4” 219.20
(8.63)
AIRBLEED DRAIN PORT SENSITIVITY: 13.8 BAR
7/16-20UNF-2B 115.06
ST. THREAD O-RING (4.53) (200 PSI) PER TURN Side View
SAE-4
OPTION “8”
Front View
ISO 6149-4 OPTION “5”
ADAPTER FITTING SHAFT OPTION “B” VOLUME STOP OPTION “2”
ON OPTION “8” 14 TOOTH VOLUME STOP
SAE “C” SPLINE SENSITIVITY:
12/24 PITCH 4.2 CC/REV/TURN 27.68 SENSITIVITY:
83.82 3.8 CC/REV/TURN
MAX. TORQUE = 55.63 (3.30) (1.09)
641 N·m (5,680 IN-LBS) (2.19) MAX MAX

Parker Hannifin Corporation


Hydraulic Pump Division
24 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Notes Series PAVC

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 25
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Technical Information Series PAVC 100

Performance Information
Series PAVC100 Pressure Compensated,
Variable Volume, Piston Pump

Features
• High Strength Cast-Iron Housing
• Built-In Supercharger
• High Speed Capability - 2600 RPM
• Cartridge Type Controls - Field Changeable
• Replaceable Bronze Clad Port Plate
• Airbleed Standard for Quick Priming
• Hydrodynamic Cylinder Barrel Bearing
• Full Pressure Rating on Water Glycol Fluids
• Filtered and/or Cooled Drain Line
Capable 7 bar (100 PSI) Maximum
• Thru-Shaft Capable
Specifications
Controls
Pressure Ratings:
• Pressure Compensation
Outlet Port: 207 bar (3000 PSI) Continuous (P1)
• Remote Pressure Compensation 248 bar (3600 PSI) Peak (P3)
• Load Sensing
Inlet Port: 1.7 bar (25 PSI) Maximum
• Power (Torque) Limiting
0.17 bar (5 In. Hg.) Minimum
• Power Limiting and Load Sensing @ 1800 RPM (See Inlet Chart
• Adjustable Maximum Volume Stop for other speeds)
• Low Pressure Standby
Control Drain: 7 bar (100 PSI) Maximum
Speed Ratings: 600 to 2600 RPM
Operating Temperature Range: – 40°C to 71°C
Schematic Symbol (– 40°F to 160°F)
(Basic Pump)
Housing Material: Cast-Iron
Filtration: Maintain SAE Class 4, ISO 16/13,
ISO 18/15 Maximum Recommended
Mounting: SAE C 2-Bolt Flange Mount or Diagonally
Weight and Package Size on SAE C 4-Bolt Flange Mount

Weight
Length From
Height Height
Installation Data: See page A46 of this catalog for
Model In
Mounting
in CM in CM specific recommendations pertaining to system
Kg (Lb) Face in CM (Inches) (Inches) cleanliness, fluids, start-up, inlet conditions, shaft
(Inches)
alignment, drain line restrictions and other important
PAVC100 50 (110) 30.73 (12.10) 24.90 (9.82) 21.59 (8.50) factors relative to the proper installation and use of
these pumps.
Quick Reference Data Chart
Pump Delivery *Approx. Noise Levels dB(A) Input Power At
Displacement @ 21 bar (300 PSI) @ Full Flow 1800 RPM (1200 RPM) 1800 RPM, Max.
Pump Model CM3/REV in LPM (GPM) 69 bar 138 bar 207 bar Displacement &
(IN3/REV)
1200 RPM 1800 RPM (1000 PSI) (2000 PSI) (3000 PSI) 207 bar (3000 PSI)

PAVC100 100 (6.1) 119.6 (31.6) 179.8 (47.5) 82 (78) 82 (79) 85 (80) 71.2 kw (95.5 hp)
* Since many variables such as mounting, tank style, plant layout, etc., effect noise levels, it cannot be assumed that the above readings will be equal to those in the
field. The above values are for guidance in selecting the proper pump. Noise levels are A-weighted, mean sound pressure levels at 1 meter from the pump, measured
and recorded in accordance with applicable ISO and NFPA standards.

Parker Hannifin Corporation


Hydraulic Pump Division
26 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Performance Data Series PAVC 100

Typical Performance Data - Fluid: Standard Hydraulic Oil 100 SSU @ 49°C (120°F)
PAVC100 @ 1200 RPM PAVC100 @ 1800 RPM
LPM GPM Volumetric Efficiency KW HP LPM GPM Volumetric Efficiency KW HP
100 189.3 (50) 74.6 (100) 100 189.3 (50) 74.6 (100)
Efficiency - %

Efficiency - %
90 170.3 (45) 90 170.3 (45) Flow
iency
67.1 (90) 67.1 (90)
Effic
Overall
80 151.4 (40) 59.7 (80) 80 151.4 (40) cy 59.7 (80)
icien
ll Eff
era
70 132.5 (35) 52.2 (70) 70 132.5 (35) 52.2 (70)
Flow Ov
60 113.6 (30) 44.7 (60) 60 113.6 (30) 44.7 (60)

Power

Power
Fl er
Flow

Flow
94.6 (25) 37.3 (50) 94.6 (25) 37.3 (50)

ll w
ow
Fu Po
at put
75.7 (20)
er 29.8 (40) 75.7 (20) 29.8 (40)
w w

In
o
P lo
56.8 (15)
p ut ll F 22.4 (30) 56.8 (15) 22.4 (30)
In t Fu
37.9 (10)
a 14.9 (20) 37.9 (10) 14.9 (20)

wer
wer sated Po
18.9 (5)
sated Po
7.5 (10) 18.9 (5) Compen 7.5 (10)
Compen
0 (0) 0 (0) 0 (0) 0 (0)
Bar 0 69 138 207 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000) PSI (0) (1000) (2000) (3000)
Pressure Pressure

NOTE: The efficiencies and data in the graph are good only WHERE:
for pumps running at 1800 RPM and stroked to maximum. To Q = Actual Output Flow in GPM
calculate approximate input power for the other conditions, use PSI = Pressure At Pump Outlet
the following formula:
CHp = Input Power @ Full Compensation

[
HP = Q x (PSI)
1714 ] + (CHp) @ 1800 RPM (from graph read at
operating pressure)

Actual GPM is directly proportional to drive speed and


maximum volume setting. Flow loss, however, is a function
of pressure only.

PAVC100
Inlet Characteristics at Full Displacement Compensated Control
bar PSI
(Graph only valid at sea level) LPM GPM
Drain Flow @ 1800 RPM
.41 (6) 15.1 (4)

Recommended
.28 (4)
Operating Condition
11.3 (3)
.14 (2)
Inlet Pressure

Drain Flow

bar In-Hg
0 (0)
7.6 (2)
.17 (5)
Vacuum

.34 (10)
DO NOT OPERATE 3.8 (1)

.51 (15) IN THIS REGION


.68 (20) 0 (0)
0 500 1000 1500 2000 2600 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000)
Shaft Speed - RPM
System Pressure
Parker Hannifin Corporation
Hydraulic Pump Division
Marysville, Ohio USA 27
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Performance Data Series PAVC 100

Typical Performance Data -

Minimum Power Settings Attainable


With Control Options C, H, CM & HM

PAVC100
KW (HP)
55.9 (75)
207 bar (3000 PSI)
Comp. Setting

NOTE: Minimum attainable HP setting means that input power


44.7 (60) 172 bar (2500 PSI)
Comp. Setting will not exceed the indicated setting at the indicated RPM and
that the pump will achieve full compensator pressure selected.
138 bar (2000 PSI)
33.6 (45) Comp. Setting If setting input power limiter below full flow boundary, full flow
Power

Full Flow Boundary may not be obtained at low operating pressure.


103 bar (1500 PSI) Determine maximum input power limitation at desired RPM.
22.4 (30) Comp. Setting All points above desired compensator setting curve can be
69 bar (1000 PSI)
Comp. Setting achieved.
11.2 (15) 34 bar (500 PSI)
Comp. Setting

0 0
0 600 1200 1800 2400 3000

Shaft Speed - RPM

Power (Torque) Limiting Curves

PAVC100 PAVC100
@ 1200 RPM @ 1800 RPM
LPM GPM KW HP LPM GPM KW HP
132.5 (35) 52.2 (70) 189.3 (50) 74.6 (100)
170.3 (45) 67.1 (90) N·m In-Lbs
113.6 (30) 44.7 (60) N·m In-Lbs 339.0 (3000)
339.0 (3000) 151.4 (40) 59.7 (80)
94.6 (25) 37.3 (50) 132.5 (35) 52.2 (70) 282.5 (2500)
282.5 (2500)
Input Power
Input Power

Input Torque
113.6 (30) 44.7 (60)
Input Torque

75.7 (20) 29.8 (40) 226.0 (2000)


226.0 (2000)
Flow

Flow

94.6 (25) 37.3 (50)


56.8 (15) 22.4 30 75.7 (20) 169.5 (1500)
169.5 (1500) 29.8 (40)

37.9 (10) 14.9 (20) 56.8 (15) 22.4 (30)


113.0 (1000) 113.0 (1000)
37.9 (10) 14.9 (20)
18.9 (5) 7.5 (10) 56.5 (500) 56.5 (500)
18.9 (5) 7.5 (10)
0 (0) 0 (0) 0 (0) 0 (0) 0 (0) 0 (0)
Bar 0 69 138 207 Bar 0 69 138 207
PSI (0) (1000) (2000) (3000) PSI (0) (1000) (2000) (3000)
Pressure Pressure

See page 12 for “How to Read Curves” information.

Parker Hannifin Corporation


Hydraulic Pump Division
28 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 100

Rear Ported Pump Dimensions


* Inch equivalents for millimeter dimensions are shown in (**).

Note:
Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain,
signal port and pump controls will be on other side.

Port Location
Outlet Inlet
Outlet Port Inlet Port Control Drain Signal Port
Option Option
2" SAE 4-Bolt Flange SAE-6 SAE-4
SAE-20 Straight Thread
Omit Omit 1/2-13UNC Threads Standard Straight Thread Straight Thread
(1-5/8-12UNC)
Pressure Series (Code 61) (9/16-18UNF) (7/16-20UNF)
1-1/4" SAE Flange
2" SAE 4-Bolt Flange SAE-6 SAE-4
7/16-14UNC Thread
3 Omit 1/2-13UNC Threads Standard Straight Thread Straight Thread
Standard Pressure
Pressure Series (Code 61) (9/16-18UNF) (7/16-20UNF)
Series (Code 61)

Ø 38.100 (1.500)
38.049 (1.498)

55.62 42.392 (1.669) 61.97


(2.19) 42.138 (1.659) (2.44)
SHAFT OPTION “B” SHAFT OPTION “C” SHAFT OPTION “D”
SAE “C” SPLINE SAE “C-C” SHAFT SAE “C-C” SPLINE
14 TOOTH 12/24 DP MAX. TORQUE = 17 TOOTH 12/24 DP
MAX. TORQUE = 1,218 N·m (10,780 IN-LBS) MAX. TORQUE =
639 N·m (5,680 IN-LBS) 1,218 N·m (10,780 IN-LBS)

107.95 107.95 OUTLET PORT


(4.25) (4.25) VENT-FILL/INLET OPTION “OMIT”
77.72 GAUGE PORT SEE CHART FOR 139.70
(3.06) 7/16-20UNF-2B PORT SIZE (5.50)
STRAIGHT
THREAD O-RING 41.40
(1.63)

117.34
(4.62)
28.70
(1.13)
93.21
(3.67)
42.92
(1.69)
141.47
Rotation

RPM

(5.57)
VARIABLE VOLUME PUMP

INITIAL FACTORY SETTINGS BELOW

31.75
Otsego, Mich. 49078 USA
Fluidpower Pump Division
@
PSI max
cc/Rev

PSI

(1.25)
GPM
HP

101.60
(4.00) SHAFT OPTION “OMIT”
Ø50.80 SAE “C” SHAFT
(2.00) MAX. TORQUE =
639 N·m
(5,680 IN-LBS)

PRESSURE COMPENSATOR TORQUE CONTROL ADJUSTMENT


REAR INLET PORT ADJUSTMENT SENSITIVITY: (CONTROL OPTIONS C,H,CM & HM)
(INLET PORT OPTION “OMIT”) 55 BAR (800 PSI) PER REV SENSITIVITY: 130 N·m
SEE CHART FOR PORT SIZE (1,150 IN-LBS) PER REV.

Rear View Top View

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 29
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 100

Rear Ported Pump Dimensions


* Inch equivalents for millimeter dimensions are shown in (**).

Note:
Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain,
signal port and pump controls will be on other side.

41.40 OPTION “3”


(1.63) OUTLET PORT
Ø 31.75 (SEE CHART ON PAGE A166
(1.25) FOR PORT SIZE)

28.70
(1.13)
58.67
(2.31)

30.22
Option “3”
(1.19) Outlet Port

ADAPTABLE TO SAE “C” 2-BOLT


MOUNTING OR DIAGONALLY ON
SAE “C” 4-BOLT MOUNTING

OUTLET 90.42 90.42


PRESSURE (3.56) (3.56)
GAUGE PORT
7/16-20UNF-2B 81.02 81.02 55.62 303.53
(3.19) (3.19) PORT “B” SIGNAL (2.19) (11.95)
STRAIGHT STRAIGHT THREAD
THREAD O-RING O-RING
SEE CHART ON A166 ROTATION ARROW
FOR PORT SIZE 12.44
(.49)
7.925 (.312)
WIDE KEY 158.49
7.11 (6.24)
R
(.28)
35.33 (1.391)
91.94 35.07 (1.381)
(3.62)
127.00
(5.000)
Ø 126.94
(4.998)
74.67 31.75 (1.250)
(2.94) Ø31.69 (1.248)

112.77
(4.44)
AIRBLEED 36.32 PORT “A” CONTROL 2.54
DRAIN PORT (1.43) STRAIGHT THREAD O-RING OPTION “2” (.10)
7/16-20UNF-2B SEE CHART ON A166 41.40 MAX. VOLUME MAX
ST. THREAD O-RING FOR PORT SIZE 73.15 (1.63) ADJUSTMENT
SAE-4 (2.88) SENSITIVITY:
5CC/REV/REV 55.88
104.90
(4.13) (2.20)
OPTION “4” MAX
114.30
(4.50) DIFFERENTIAL
MAX PRESSURE
ADJUSTMENT OPTION “5”
28 BAR (400 PSI) MAX. VOLUME ADJUSTMENT
PER REV. SENSITIVITY: 5.6CC/REV/REV

Front View Side View

Parker Hannifin Corporation


Hydraulic Pump Division
30 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 100

Top/Bottom Ported Pump Dimensions


* Inch equivalents for millimeter dimensions are shown in (**).

Notes:
1. Pump shown and dimensioned is a clockwise rotation top/
bottom inlet option pump. For a counterclockwise rotation
pump the outlet port, control drain, signal port, and pump
controls will be on other side.
2. For other available shafts see page A34.
OPTION “2”
INLET PORT FLANGE
VENT-FILL/INLET INLET PORT
GAUGE PORT SEE CHART A169
107.95 107.95 7/16-20UNF-2B
(4.25) (4.25) 244.34 (9.62) FOR PORT SIZE
STRAIGHT THREAD
O-RING 139.70 (TOP PORT) BOTTOM PORT
(5.50) OPPOSITE SIDE
SAME PATTERN
41.40 ROTATED 90˚
THREADED OURTLET PORT (1.63)
OUTLET PORT OPTION “OMIT”
SEE CHART A169
114.30 FOR PORT SIZE
(4.50)
28.70
93.21 (1.13)
(3.67) SHAFT OPTION
“OMIT”
SAE “C” SHAFT 42.92
MAX. TORQUE = (1.69)
101.60 639 N·m

Rotation

RPM
(4.00) (5,680 IN-LBS)

VARIABLE VOLUME PUMP


31.75

INITIAL FACTORY SETTINGS BELOW

Otsego, Mich. 49078 USA


Hydraulics Pump Division
@
ø 50.80

PSI max
cc/Rev
138.43 (1.25)

PSI
GPM
HP
(5.45) (2.00)

159.25
(6.27)
PRESSURE COMPENSATOR 77.72
ADJUSTMENT SENSITIVITY: (3.06)
55 BAR (800 PSI) PER REV
TORQUE CONTROL ADJUSTMENT
(CONTROL OPTIONS C,H,CM & HM)
ADAPTABLE TO
SAE “C” 2-BOLT
Rear View Top View SENSITIVITY: 130 N·m (1,150 IN-LB) PER REV.
MOUNTING OR SIGNAL PORTS
DIAGONALLY ON PORT “B”
SAE “C” 4-BOLT 90.42 90.42 SEE CHART, A169
MOUNTING (3.56) (3.56) FOR PORT SIZE
81.02 81.02 55.62 310.13 (12.21)
OUTLET (3.19) (3.19) (2.19)
PRESSURE
GAUGE PORT 12.44 ROTATION ARROW
7/16-20UNF-2B (.49)
ST. THREAD
O-RING 7.925 (.312)
WIDE KEY 159.49
R7.11 (6.24)
(.28)
35.33 (1.391)
91.94 35.07 (1.381)
(3.62)

74.67
(2.94) ø 31.75 (1.250)
31.69 (1.248)

127.00 (5.000)
ø 126.94 (4.998)
36.32
(1.43)
112.77
(4.44) CONTROL DRAIN
PORT “A” OPTION “2”
SEE CHART, A169 MAX. VOLUME
AIRBLEED FOR PORT SIZE
DRAIN PORT ADJUSTMENT
7/16-20UNF-2B 41.40 5CC/REV/REV
73.15
ST. THREAD O-RING (1.63) (2.88)
SAE-4 BOTTOM
104.90 INLET PORT
OPTION “8” OPTION “4” (4.13)
ISO 6149-4 114.30 DIFFERENTIAL 237.99 (9.37) 49.53
ADAPTER FITTING (4.50) PRESSURE (BOTTOM PORT) (1.95)
ON OPTION “8” MAX ADJUSTMENT MAX.
28 BAR (400 PSI)
PER REV
OPTION “5”
Front View Side View MAX. VOLUME
ADJUSTMENT
5.6CC/REV/REV

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 31
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 100

Top/Bottom Ported Pump Dimensions


* Inch equivalents for millimeter dimensions are shown in (**).

Note:
Pump shown and dimensioned is a clockwise rotation pump. For a counterclockwise rotation pump the outlet port, control drain,
signal port and pump controls will be on other side.

Port Location
Outlet Inlet
Outlet Port Inlet Port Control Drain Signal Port
Option Option
2" SAE 4-Bolt Flange SAE-6 SAE-4
SAE-20 Straight Thread
Omit 2 1/2-13UNC Threads Standard Straight Thread Straight Thread
(1-5/8-12UN)
Pressure Series (Code 61) (9/16-18UNF) (7/16-20UNF)
1-1/4" SAE Flange 2" SAE 4-Bolt Flange SAE-6 SAE-4
3 2 7/16-14UNC Thread Standard 1/2-13UNC Threads Standard Straight Thread Straight Thread
Pressure Series (Code 61) Pressure Series (Code 61) (9/16-18UNF) (7/16-20UNF)

Dimensions – Thru-Shaft Options


* Inch equivalents for millimeter dimensions are shown in (**).

Variation
Ø 82.58/82.60 106.38
6A4 — N/A 3/8-16UNC-2B N/A 9 Tooth 16/32 Pitch N/A
(3.251/3.252) (4.188)
53.98 Ø 101.63/101.65 146.05 89.81
6B3 1/2-13UNC-2B 1/2-13UNC-2B 13 Tooth 16/32 Pitch N/A
(2.125) (4.001/4.002) (5.750) (3.536)
53.98 Ø 101.63/101.65 146.05 89.81
6B4 1/2-13UNC-2B 1/2-13UNC-2B 15 Tooth 16/32 Pitch N/A
(2.125) (4.001/4.002) (5.750) (3.536)
53.98 Ø 127.03/127.05 180.98 114.50
6C3 5/8-11UNC-2B 1/2-13UNC-2B 14 Tooth 12/24 Pitch N/A
(2.125) (5.001/5.002) (7.125) (4.508)

Parker Hannifin Corporation


Hydraulic Pump Division
32 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Dimensional Data Series PAVC 100

Thru-Shaft Options – Dimensions


* Inch equivalents for millimeter dimensions are shown in (**).

Notes:
1. Rear adapters may be rotated 90°.
2. Pump shown is a clockwise rotation pump. For a
counterclockwise pump the outlet port, control drain and control
adjustments will be on opposite side.
3. Maximum torque transmitting capacity for rear mounting of
pumps is 639 N•m (5,680 In. Lbs). Lower allowables may
apply based on pump mounted on rear.

299.72
(11.80) A
C
C
2

Side View Rear View

Variations 6A* & 9A*

H
C
C
2

D
2
D
G

D
2
D

Rear View
Variations 6B* & 6C*
9B* & 9C*

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 33
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Installation Information Series PAVC 33/38/65/100

Generic Pump Assembly


MAX VOL. STOP
VARIATION - 5

95 N·m
(70 FT. LBS.)
TORQUE

MAX VOL. STOP


VARIATION - 2

23 N·m
(17 FT. LBS.)
TORQUE

1 TRUNNION CAP ASSEMBLY 4 RETAINER DETAIL 7 AIR BLEED ASSEMBLY

THRUST WASHER
(Not on PAVC100)

SNAP RING BODY


O-RING SPRING STAKE BALL
TRUNNION CAP IN PLACE
BALL
ROLLER BEARING
5 BEARING SHAFT ASSEMBLY 8 ADJUSTING STEM ASSEMBLY
2 SLEEVE ASSEMBLY

PLUG 1 2 1 1 2
STEM
SLEEVE 1 2 1 2 2 1 O-RING 1
O-RING 1 BACK-UP RING 2
BACK-UP RING 2
9 PORT PLATE
3 PLUG ASSEMBLY 6 PISTON - DIFFERENTIAL LEFT HAND (CCW) PORT PLATE
SHOWN IN ASSEMBLY (ABOVE).
CONTROL
RIGHT HAND (CW) PORT PLATE
SHOWN BELOW.
PISTON BODY
SLEEVE
1 2
O-RING 1
O-RING 1 1 2
BACK-UP RING 2
BACK-UP RING 2

Parker Hannifin Corporation


Hydraulic Pump Division
34 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Installation Information Series PAVC 33/38/65/100

THESE ITEMS ARE SHOWN IN


POSITION FOR CONTROL OPTION
“OMIT”. SEE SEPARATE DIAGRAM
FOR OTHER CONTROL OPTIONS.
13.5 N·m
(10 FT. LBS.)
TORQUE
169 N·m 5
(125 FT. LBS.)
TORQUE
76

7
108 N·m
(80 FT. LBS.)
TORQUE 6 ADJUSTABLE
2 DIFFERENTIAL
VARIATION - 4

5
9

68 N·m
(50 FT. LBS.)
TORQUE
3
NON-ADJUSTABLE
8 DIFFERENTIAL
VARIATION - OMIT
27 N·m
(20 FT. LBS.)
TORQUE
PAVC 33, 38, 65
Position
3 Control
Option
Omit Open 800599 108 x 4 108 x 4 Omit
A 102 x 1 800599 Open 108 x 4   787474*
C 102 x 1 800599 Open 108 x 4   787474*
H Open 800599 108 x 4 108 x 4 Omit
M 800599 Open Open 108 x 4 Omit
ME 102 x 1 800599 Open 108 x 4   787474*
S 800599 Open Open 108 x 4 Omit
SE 102 x 1 800599 Open 108 x 4 Omit
AM 102 x 1 800599 786635 Open   787474*
CM 102 x 1 800599 786635 Open   787474*
HM 800599 Open Open 108 x 4 Omit
* Available Only on PAVC65.
4
PAVC 100
Position
POSITION 1 Control ‡

Option
POSITION 2 Omit Open 690870 108 x 4 108 x 4 787474
A 102 x 1 690870 Open 108 x 4 787474
10 TORQUE (HP) CONTROL (See next page) C 102 x 1 690870 Open 108 x 4 787474
H Open 690870 108 x 4 108 x 4 787474
11 VOLUME SERVO FEEDBACK (See next page) M 690870 Open Open 108 x 4 787474
Part Number Description ME 102 x 1 690870 Open 108 x 4 787474
102 x 1 Solid Pipe Plug (1/16") S 690870 Open Open 108 x 4 787474
108 x 4 SAE Plug - 4 SE 102 x 1 690870 Open 108 x 4 787474
690870 .028 Orifice Plug (1/16") AM 102 x 1 690870 786635 Open 787474
800599 .034 Orifice Plug (1/16")
786635 .034 Orifice Fitting CM 102 x 1 690870 786635 Open 787474
787474 Upstroke Spring HM 690870 Open Open 108 x 4 787474

787474 is always included with the PAVC100.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 35
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Installation Information Series PAVC 33/38/65/100

10 CONTROL OPTION “C” & “H”


PRESSURE, POWER & FLOW

27 N·m (20 FT.-LBS.) TORQUE


14 N·m (10 FT.-LBS.) TORQUE
10-32UNF-2B SET @ MAX. PRESSURE PER TEST
OMIT SPEC. THEN INSTALL JAM NUT, LOCKING
NUT AND LOCKING TAB.

ADD

11 CONTROL OPTION “S” & “SE”


SERVO VOLUME FEEDBACK

16 N·m (12 FT.-LBS.) TORQUE

HAND TIGHTEN NUT


TORQUE AT TEST

102 x 1 PIPE
PLUG

ADD
98 x 16 BALL
ADD

10-32UNF-2B OMIT

SERVO VOLUME ASSEMBLY


PIPE PLUG
102 x 1

RETAINING O-RING
SLEEVE
O-RING PROBE
SPRING

BALL
LVDT ASSEMBLY
PUMP SERVO
HOUSING VOLUME LOCKING NUT
CONTROL HOUSING
BUTTON
Parker Hannifin Corporation
SERVO
Hydraulic Pump Division
PISTON
36 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Installation Information Series PAVC 33/38/65/100

Use Of A Relief Valve


The use of a relief valve, while not mandatory is
recommended in the main circuit to suppress hydraulic
shock loads and additional system protection. If a
minimum volume stop is used,
the use of a relief valve is mandatory.

Fluid Recommendations
Premium quality hydraulic oil with a viscosity range
between 150-250 SSU (30-50 cst.) at 38°C (100°F).
Normal operating viscosity range between 80-1000
SSU (17-180 cst.). Maximum start-up viscosity is
4000 SSU (1000 cst.).
Note: Consult Parker when exceeding 71°C (160°F)
operation. Oil should have maximum anti-wear
properties, rust and oxidation treatment.

Filtration
For maximum pump and system component life, Installation and Mounting
the system should be protected from contamination at When a PAVC Series Pump is mounted above the fluid
a level not to exceed 125 particles greater than level, the position of the “control drain” is not restricted
10 microns per milliliter of fluid. (SAE Class 4/ISO but the inlet port should not be on the bottom
16/13). Due to the nature of variable displacement (PAVC100). When a PAVC Series Pump is mounted
pumps, variations in pump inlet conditions, fluid below the fluid level the position of all ports are not
acceleration losses, system aeration, and duty cycle restricted. The “control drain” should be a separate line
we do not recommend suction line filters. We do to the reservoir and extend below the oil level as far
recommend the use of a properly sized, in-tank suction from the inlet line as possible. The “control drain” line
strainer. Contact your Parker representative for can be filtered and/or cooled (must not exceed 7 bar
assistance. (100 PSI) back pressure). Suggested maximum line
length is 10 feet.
Start-Up
On initial start-up, the case should be filled with oil, A built in airbleed is standard on all PAVC 33, 38, 65
pressure should be reduced and the circuit should be and 100 Pumps. To connect, remove airbleed drain
open or the air bled from the pump outlet to permit plug and connect a line unrestricted to reservoir
priming. Use of the airbleed is recommended on initial extending below minimum oil level. Back pressure
start-up. See Installation and Mounting Section to in this line must not exceed .28 bar (4 PSI).
connect airbleed.
Special Installations
Inlet Conditions Consult your Parker representative for any application
Not to exceed .17 bar (5 In. Hg.). Vacuum at 1800 RPM requiring the following:
on petroleum base fluids. See recommended speed Pressure above rated, drive speed above maximum,
spectrum for specific inlet conditions. indirect drive, fluid other than petroleum oil,
oil temperature above 71°C (160°F).
Shaft Rotation and Line Up
Pump and motor shaft alignment must be within Inlet Pressure
.010 TIR maximum, using a standard floating coupling. Not to exceed 1.72 bar (25 PSI).
Please follow coupling manufacturer’s recommended
installation instructions to prevent
end thrust on pump shaft. Turn pump to assure
freedom of rotation. Pump and motor must be
on a rigid base.
The coupling should be sized to absorb the peak
horsepower developed.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 37
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Notes Series PAVC

Parker Hannifin Corporation


Hydraulic Pump Division
38 Marysville, Ohio USA
Catalog HY28-2662-CD/US Variable Displacement Piston Pumps
Offer of Sale Series PAVC

The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, Hydraulics Group, and its authorized distributors (“Seller”) are hereby
offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions. Buyer’s order for
any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be referred to as “Products”.

1. Terms and Conditions. Seller’s willingness to offer Products, or accept an order for 11. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise,
Products, to or from Buyer is expressly conditioned on Buyer’s assent to these Terms and Seller shall retain a security interest in the goods delivered and this agreement shall be
Conditions and to the terms and conditions found on-line at www.parker.com/saleterms/. deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes
Seller objects to any contrary or additional term or condition of Buyer’s order or any other Seller as its attorney to execute and file on Buyer’s behalf all documents Seller deems
document issued by Buyer. necessary to perfect its security interest. Seller shall have a security interest in, and lien
2. Price Adjustments; Payments. Prices stated on the reverse side or preceding pages upon, any property of Buyer in Seller’s possession as security for the payment of any
of this document are valid for 30 days. After 30 days, Seller may change prices to reflect any amounts owed to Seller by Buyer.
increase in its costs resulting from state, federal or local legislation, price increases from its 12. Improper Use and Indemnity. Buyer shall indemnify, defend, and hold Seller harmless
suppliers, or any change in the rate, charge, or classification of any carrier. The prices stated from any claim, liability, damages, lawsuits, and costs (including attorney fees), whether for
on the reverse or preceding pages of this document do not include any sales, use, or other personal injury, property damage, patent, trademark or copyright infringement or any other
taxes unless so stated specifically. Unless otherwise specified by Seller, all prices are F.O.B. claim, brought by or incurred by Buyer, Buyer’s employees, or any other person, arising out
Seller’s facility, and payment is due 30 days from the date of invoice. After 30 days, Buyer of: (a) improper selection, improper application or other misuse of Products purchased by
shall pay interest on any unpaid invoices at the rate of 1.5% per month or the maximum Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use
allowable rate under applicable law. of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product;
3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and or (d) Buyer’s failure to comply with these terms and conditions. Seller shall not indemnify
Seller shall not be responsible for any damages resulting from any delay. Regardless of the Buyer under any circumstance except as otherwise provided.
manner of shipment, title to any products and risk of loss or damage shall pass to Buyer 13. Cancellations and Changes. Orders shall not be subject to cancellation or change by
upon tender to the carrier at Seller’s facility (i.e., when it’s on the truck, it’s yours). Unless Buyer for any reason, except with Seller’s written consent and upon terms that will indemnify,
otherwise stated, Seller may exercise its judgment in choosing the carrier and means of defend and hold Seller harmless against all direct, incidental and consequential loss or
delivery. No deferment of shipment at Buyers’ request beyond the respective dates indicated damage. Seller may change product features, specifications, designs and availability with
will be made except on terms that will indemnify, defend and hold Seller harmless against notice to Buyer.
all loss and additional expense. Buyer shall be responsible for any additional shipping 14. Limitation on Assignment. Buyer may not assign its rights or obligations under this
charges incurred by Seller due to Buyer’s changes in shipping, product specifications or in agreement without the prior written consent of Seller.
accordance with Section 13, herein. 15. Entire Agreement. This agreement contains the entire agreement between the Buyer
4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects in and Seller and constitutes the final, complete and exclusive expression of the terms of the
material or workmanship for a period of eighteen months from the date of delivery to Buyer. agreement. All prior or contemporaneous written or oral agreements or negotiations with
The prices charged for Seller’s products are based upon the exclusive limited warranty respect to the subject matter are herein merged.
stated above, and upon the following disclaimer: DISCLAIMER OF WARRANTY: THIS 16. Waiver and Severability. Failure to enforce any provision of this agreement will not
WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO waive that provision nor will any such failure prejudice Seller’s right to enforce that provision
PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRAN- in the future. Invalidation of any provision of this agreement by legislation or other rule of law
TIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR shall not invalidate any other provision herein. The remaining provisions of this agreement
A PARTICULAR PURPOSE. will remain in full force and effect.
5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon 17. Termination. This agreement may be terminated by Seller for any reason and at any
delivery. No claims for shortages will be allowed unless reported to the Seller within 10 days time by giving Buyer thirty (30) days written notice of termination. In addition, Seller may by
of delivery. No other claims against Seller will be allowed unless asserted in writing within written notice immediately terminate this agreement for the following: (a) Buyer commits a
60 days after delivery or, in the case of an alleged breach of warranty, within 30 days after breach of any provision of this agreement (b) the appointment of a trustee, receiver or custo-
the date within the warranty period on which the defect is or should have been discovered dian for all or any part of Buyer’s property (c) the filing of a petition for relief in bankruptcy
by Buyer. Any action based upon breach of this agreement or upon any other claim arising of the other Party on its own behalf, or by a third party (d) an assignment for the benefit of
out of this sale (other than an action by Seller for any amount due to Seller from Buyer) must creditors, or (e) the dissolution or liquidation of the Buyer.
be commenced within thirteen months from the date of tender of delivery by Seller or, for 18. Governing Law. This agreement and the sale and delivery of all Products hereunder
a cause of action based upon an alleged breach of warranty, within thirteen months from shall be deemed to have taken place in and shall be governed and construed in accordance
the date within the warranty period on which the defect is or should have been discovered with the laws of the State of Ohio, as applicable to contracts executed and wholly performed
by Buyer. therein and without regard to conflicts of laws principles. Buyer irrevocably agrees and
6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, consents to the exclusive jurisdiction and venue of the courts of Cuyahoga County, Ohio
REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE with respect to any dispute, controversy or claim arising out of or relating to this agreement.
PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, Disputes between the parties shall not be settled by arbitration unless, after a dispute has
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS arisen, both parties expressly agree in writing to arbitrate the dispute.
THE RESULT OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no
OF USE OF THE PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets
EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER’S WRITTEN CONSENT, or similar rights except as provided in this Section. Seller will defend and indemnify Buyer
EVEN IF SELLER HAS BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress
OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER’S LIABILITY UNDER ANY and trade secrets (“Intellectual Property Rights”). Seller will defend at its expense and will
CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCTS. pay the cost of any settlement or damages awarded in an action brought against Buyer
7. Contingencies. Seller shall not be liable for any default or delay in performance if based on an allegation that a Product sold pursuant to this Agreement infringes the Intel-
caused by circumstances beyond the reasonable control of Seller. lectual Property Rights of a third party. Seller’s obligation to defend and indemnify Buyer
8. User Responsibility. The user, through its own analysis and testing, is solely responsible is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of
for making the final selection of the system and Product and assuring that all performance, such allegations of infringement, and Seller having sole control over the defense of any
endurance, maintenance, safety and warning requirements of the application are met. The allegations or actions including all negotiations for settlement or compromise. If a Product is
user must analyze all aspects of the application and follow applicable industry standards and subject to a claim that it infringes the Intellectual Property Rights of a third party, Seller may,
Product information. If Seller provides Product or system options, the user is responsible for at its sole expense and option, procure for Buyer the right to continue using the Product,
determining that such data and specifications are suitable and sufficient for all applications replace or modify the Product so as to make it noninfringing, or offer to accept return of
and reasonably foreseeable uses of the Products or systems. the Product and return the purchase price less a reasonable allowance for depreciation.
9. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confiden- Notwithstanding the foregoing, Seller shall have no liability for claims of infringement based
tial information or equipment furnished by Buyer or any other items which become Buyer’s on information provided by Buyer, or directed to Products delivered hereunder for which
property, may be considered obsolete and may be destroyed by Seller after two consecutive the designs are specified in whole or part by Buyer, or infringements resulting from the
years have elapsed without Buyer placing an order for the items which are manufactured modification, combination or use in a system of any Product sold hereunder. The foregoing
using such property. Seller shall not be responsible for any loss or damage to such property provisions of this Section shall constitute Seller’s sole and exclusive liability and Buyer’s sole
while it is in Seller’s possession or control. and exclusive remedy for infringement of Intellectual Property Rights.
10. Special Tooling. A tooling charge may be imposed for any special tooling, including 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise, sales,
without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. use, property, occupational or like taxes which may be imposed by any taxing authority upon
Such special tooling shall be and remain Seller’s property notwithstanding payment of any the manufacture, sale or delivery of Products.
charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging to 21. Equal Opportunity Clause. For the performance of government contracts and where
Seller which is utilized in the manufacture of the Products, even if such apparatus has been dollar value of the Products exceed $10,000, the equal employment opportunity clauses in
specially converted or adapted for such manufacture and notwithstanding any charges paid Executive Order 11246, VEVRAA, and 41 C.F.R. §§ 60-1.4(a), 60-741.5(a), and 60-250.4,
by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or otherwise are hereby incorporated.
dispose of any special tooling or other property in its sole discretion at any time.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 39
North America Truck Tel: (39) 02 45 19 21 Mahape, Navi Mumbai
USA Tel: (91) 22 5613 7081
Industrial The Netherlands
USA Eastern Region Oldenzaal Korea
Chicago Region Cleveland, OH Tel: (31) 541 585000 Seoul
Naperville, IL Tel: (440) 519 1125 Tel: (82) 2 559 0400
Norway
Tel: (630) 964 0796 Western Region Malaysia
Ski
Great Lakes Region San Ramon, CA Tel: (47) 64 91 10 00 Subang Jaya
Fairlawn, OH Tel: (925) 735 9573 Tel: (60) 3 5638 1476
Tel: (330) 670 2680 Poland
Canada New Zealand
Warsaw
Northeast Region Milton, Ontario Tel: (48) 22 57 32400 Mt. Wellington
Lebanon, NJ Tel: (905) 693 3000 Tel: (64) 9 574 1744
Tel: (908) 236 4121 Portugal
México Japan
Pacific Region Leca da Palmeira
Apodaca, N.L. Tel: (351) 22 999 7360 Tokyo
Buena Park, CA Tel: (52) 81 8156 6000
Tel: (714) 228 2509 Romania Tel: (81) 3 6408 3900
Southern Region Europe Bucharest Singapore
Alpharetta, GA Tel: (40) 21 252 1382 Jurong Town
Austria
Tel: (770) 619 9767 Russia Tel: (65) 6 887 6300
Wiener Neustadt
Canada Tel: (43) 2622 23501 0 Moscow Taiwan
Milton, Ontario Belgium Tel: (7) 495 580 9145 Taipei
Tel: (905) 693 3000 Slovenia Tel: (886) 2 2298 8987
Nivelles
México Tel: (32) 67 280 900 Novo Mesto Thailand
Toluca, Edo. de México Czech Republic and Tel: (386) 7 337 6650 Bangkok
Tel: (52) 72 2275 4200 Slovakia Tel: (662) 717 8140
Spain
Klecany Madrid
Mobile Tel: (420) 284 083 111 Tel: (34) 91 675 7300 Middle East
USA Denmark United Arab Emirates
Ballerup Sweden
Global Mobile Abu Dhabi
Lincolnshire, IL Tel: (45) 4356 0400 Spanga
Tel: (46) 8 597 95000 Tel: (971) 2 678 8587
Tel: (847) 821 1500 Finland
Central Region Vantaa Ukraine Latin America
Lincolnshire, IL Tel: (358) 20 753 2500 Kiev
Tel: (380) 44 494 2731 Pan American Division
Tel: (847) 821 1500 France Miami, FL
Eastern Region Contamine-sur-Arve United Kingdom Tel: (305) 470 8800
North Canton, OH Tel: (33) 4 50 25 80 25 Warwick,
Tel: (330) 284 3355 Tel: (44) 1926 317878 Argentina
Germany Buenos Aires
Midwest Region Kaarst
Hiawatha, IA Asia Pacific Tel: (54) 33 2744 4129
Tel: (49) 2131 4016 0
Tel: (319) 393 1221 Australia Brazil
Greece
Southern Region Athens Castle Hill Cachoeirinha RS
Aledo, TX Tel: (61) 2 9634 7777 Tel: (55) 51 3470 9144
Tel: (30) 210 933 6450
Tel: (817) 441 1794 Venezuela
Hungary China
Western Region Beijing Caracas
Buena Park, CA Budapest Tel: (58) 212 238 5422
Tel: (36) 1 220 4155 Tel: (86) 10 6561 0520
Tel: (714) 228 2509
Ireland Shanghai
Canada Tel: (86) 21 5031 2525 Africa
Milton, Ontario County Dublin, Baldonnell
Hong Kong South Africa
Tel: (905) 693 3000 Tel: (353) 1 466 6370
Tel: (852) 2428 8008 Kempton Park
México Italy Tel: (27) 11 961 0700
Apodaca, N.L. Corsico, Milano India
Tel: (52) 81 8156 6000

© 2012 Parker Hannifin Corporation, all rights reserved This literature replaces ALL previous literature
Catalog HY28-2662-CD/US
Parker Hannifin Corporation 5/12

Hydraulic Pump Division


14249 Industrial Parkway
Marysville, OH 43040 USA
phone 937.644.4532
fax 937.642.3639
www.parker.com