You are on page 1of 20

Catalog HY28-2661-CD/US Low Profile Power Units

Volume Control
Series V-Paks
Series V-Pak
Low Profile Power Units

Catalog HY28-2661-CD/US zpu02

1 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Introduction Volume Control
Series V-Paks

SINGLE REMOV-
ABLE TOPPLATE
PRESSURE PORT
RETURN PORT
FILLER/BREATHER

PUMP COMPENSATOR
CONTROL

OIL LEVEL GUAGE


WITH THERMOM- PUMP CASE PREFILL PORT
ETER
406mm (16") GLYCERINE FILLED
CLEANOUT COVER PRESSURE GUAGE WITH
SHUT-OFF VALVE
SAFETY RELIEF VALVE
SAE-12 RESERVOIR
DRAIN

Standard Features Benefits

• Vertical Design • Saves Floor Space


• Submerged Pump • Positive Pump Inlet
• Precision Pump Mounting Adapters • Longer Pump Life
• Suction Strainer • Protects Pump from Contamination
• Glycerine Filled Pressure Gage with Shut Off • Improved Diagnostics
• Oil Level Gage with Thermometer • Helps to Maintain Trouble-Free Performance
• Remote Compensator and Safety Relief • Protects Against System Shock
• Breather and Fill Cap • Easy to Fill Tank, Control Ingression of Airborne
Contaminants
• 1800 RPM Motor • More Flow at Less Cost
• Drain Plug • Allows Drainage of Fluid
• Clean Out Cover • Easy Access to Inside of Reservoir
• Single Removable Topplate • Easy Servicability of Internal Components
• Extra SAE-20 Return Port • Allows Flexibility for Customer Return Plumbing
• All Hydraulic Connections SAE Straight Thread • No Leaks

Quick Reference Data Chart


Low Profile Tank Size Pump Flow Electrical Motors Maximum
V-Pak Liters (Gallon) LPM (GPM) @ 1800 RPM KW (HP) BAR (PSI)
V8 302.8 (80) 136.7 (36.1) 5.6 - 30 (7 1/2 - 40) 207 (3000)

2 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Introduction Volume Control
Series V-Paks

Performance Data
Standard Features
• Vertical Design
• Submerged Pump
• Precision Pump Mounting Adapters
• Suction Strainer
• Glycerine Filled Pressure Gage with Shut Off
• Oil Level Gage with Thermometer
• Relief Valve
• External Pump Compensator Control
• Breather and Fill Cap
• 1800 RPM TEFC Motor
• Cleanout Cover
• Pressure and Return Port Block with Safety Relief
• Remote Pump Compensator Control Valve

Options
• D05 (D02) Single Station Manifold Warranty
with Safety Relief The hydraulic components on these Parker Power
• D05 (D02), D08 (D06) Multi-Station Manifold Units are warranteed for one year. This warranty may
with Safety Relief be extended to three years by using and properly
• Pressure & Return Filters (10 Micron) maintaining Parker filters.
• Variety of Manapak Sandwich Valves SUPPLY RETURN
• Heat Exchangers (Air/Oil) Schematic Symbol PORT PORT
SAE-16 SAE-20
• Combination Temp/Float Switch - Temp Fixed (Basic Unit) P T
• Single Pressure Remote Compensator “O”
OPTION
• Single Pressure Remote Compensator with Low MANIFOLD

Pressure Standby
• Bi-Pressure Remote Compensator
• Bi-Pressure Remote Compensator with Low
Pressure Standby
• Load Sensing (Flow Control)-Consult Factory M SAE-20
SPARE
• Horsepower Limiting-Consult Factory RETURN
“OMIT”
OPTION
COMP
Specifications CONTROL
SAE X
Parker “V-Pak” Hydraulic Power Units are vertical -12
design, 303 liter (80 gallon) reservoirs utilizing Parker V-PAK BASIC UNIT
Variable Volume Piston Pumps. —————————
NO OPTIONS OR ACCESSORIES
“OMIT” OPTION PUMP COMPENSATOR
“O” OPTION MANIFOLD
Installation Data:
See page 19 of this catalog or Parker Installation/
Maintenance Manual for specific recommendations
pertaining to start-up, system cleanliness, fluids,
temperatures and other important factors relative to
proper installation and use of these power units.

Pump Tank Size Pump Flow Electrical Motors Maximum


Model Liters (Gallon) LPM (GPM) @ 1800 RPM KW (HP) BAR (PSI)

V8 302.8 (80) 136.7 (11.0-36.1) 5.6 - 30 (7 1/2 - 40) 207 (3000)

3 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Ordering Information Volume Control
Series V-Paks
Omit If Not Omit If Not Omit If Not
Required Required Required

OR Reduced W
Flow

Reservoir Remote Pump Pump No Motor Electric Manifold


Compensator Control Flow (See Note) Motor
Options (GPM)
**
Ordering Code Motor Description (KW(HP)-RPM-Frame-Type)
Ordering Reservoir Size Ordering Pump Control
Code Liters (Gallons) Code Option M 5.6 (7.5)-1800-213TC-TEFC
V8 302.8 (80) Std. Remote N 7.5 (10)-1800-215TC-TEFC
Omit
Compensator
P 11.2 (15)-1800-254TC-TEFC
Load Sense
A* S 14.9 (20)-1800-256TC-TEFC
(Flow Control)
Q 18.6 (25)-1800-284TC-TEFC
* Unless otherwise
specified, a SAE-6 37° R 22.4 (30)-1800-286T-TEFC
flared port will be
Ordering Compensator supplied for customer V 29.8 (40)-1800-324T-TEFC
Code Description connection.
Electric motors are 230/460V, 60Hz, 3PH. Consult factory for
** Consult factory for other motor speeds (RPM) and voltages.
Single Pressure
Omit horsepower and hi-lo ** Use “W” prefix when no motor is required on unit. When
Remote
pump control options. ordering, “W” must be followed by motor model code equivalent
Compensator Lead time is four to frame size of motor to be used.
weeks. **Example: V815WM***=302.8 Lit (80 Gal) reservoir, std PVP33 unit
Single Pressure
B to accept a 5.6KW(7.5 HP)/213TC C-face frame motor.
Remote
Compensator With
Low Pressure Ordering Pump Flow Rate Pump Used and Description
Standby Code @ 1800 RPM
LPM (GPM)
Single Pressure
BJ 15 59 (15.6) PVP33 - Std. Remote Compensator
Remote
Compensator With
23 87 (23.0) PVP48 - Std. Remote Compensator
Low Pressure
Standby, 24VDC 36 137 (36.1) PVP 76 - Std Remote Compensator

Bi-Pressure Remote * Specify in GPM Destroked (Reduced) Flow


C
Compensator
* Unless otherwise specified, units are shipped at max. flow rate (GPM)
Bi-Pressure Remote at 1800 RPM. When reduced flow setting is required,
CJ Reduced flows from 22.5 to 8.0 GPM, specify in 0.5 GPM increments.
Compensator,
24VDC Reduced flows from 35.0 to 24.0 GPM, specify in 1.0 GPM increments.
Example: V*9.5**-- = PVP33 Pump Destroked to 9.5 GPM
Bi-Pressure Remote V*A31**-- = PVP76 Load Sense Pump Destroked to 31.0 GPM
D
Compensator With
Low Pressure
Standby
Ordering Supply/Return Port
Pump Control/Mounting Other
Bi-Pressure Remote Code Actuator Port Size
DJ
Compensator With Pressure and Return Port Block with “P” Port SAE-16
Low Pressure O None
Safety Relief and Pump Compensator Control Valves “T” Port SAE-20
Standby, 24VDC
D05 Single Station Subplate with “A” & “B” Ports
Provision For S5 None
E Safety Relief and Pump Compensator Control Valves SAE-10 Str. Thr’d
Customer Supplied
Remote Control (2) D05 Multistation Parallel Circuit Manifold with “A” & “B” Ports
M5 * None
Relief Valve Safety Relief and Pump Compensator Control Valves SAE-8 Str. Thr’d

D08 Two Parallel Circuit Manifold with “A” & “B” Ports "Y" Port
M82
Safety Relief and Pump Compensator Control Valves SAE-16 Str. Thr’d SAE-8 Str. Thr'd

* When ordering Multi-Station Manifolds, the number of stations must be specified. If valves are to be mounted,
specify the valves and sequence, if the model code exceeds 25 digits, utilize the special ordering code X.
Example: V815QM53 BCB1 Example: V815QM55B1B1CBC
3 Station D05 Manifold 5 Station D05 Manifold
Station #1: B Station #1: B1
Note: Station #2: C Station #2: B1
1. Manifolds are mounted vertically Station #3: B1 Station #3: C
Station #4: B
bottom station is number 1.
Station #5: C
2. M5-2 and 5 station available.
M8-2 station available.
For shaded option M8, lead time
is 2 weeks.

4 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Ordering Information Volume Control
Series V-Paks
Omit If Not Omit If Not Omit If Not
Required Required Required

P
Consult Factory
Directional **Manapak Options and Accessories For Special Modifications
Control Valve Control Valves

Ordering Model Technical


Valve NFPA Nominal Code Function Number Data
Ordering Model Mounting Flow LPM Circuit
Function Continuous Pump
Air/Oil: Max
Code Number Pad (GPM) Symbol A* RM-08-2-2 Oil Flow 17 LPM (4.5 GPM)
Case Cooling
-ACTUATOR- 0.6 KW (0.8 HP) Heat Rejection
Flow Control A B
Continous Pump Air/Oil: Max
1 (Meter Out) FM3DDKN D05 45 (12 )
B* Pump Case RM-19-2-2 Oil Flow 17 LPM (4.5 GPM)
-VALVE- Cooling 1.1 KW (1.5 HP) Heat Rejection

-ACTUATOR- AOC-22-2-1PH Air/Oil w/1 PH Motor


Filter/Cooling
A B C* 40CN205Q Oil Flow 32 LPM (8.5 GPM)
Pilot Operator Loop
3.3 KW (4.5 HP) Heat Rejection
3 Check CPOM3DDN D05 45 (12)
-VALVE- 10 Micron-Microglass II
Pressure P210QM250NN1 Dual Element
H Filter Mech. Indicator
** Manapak valves mounted in order of callout. First valve will be nearest DCV; last
Check Valve 493-16-D1-2 .3 BAR (5 PSI)
valve will be on manifold. K
Pump Outlet Cracking Pressure
4.6 BAR (65 PSI)
L Bypass Check C2020S65 Cracking Pressure
10 Micron-Microglass II
Return
N 40CN210Q Dual Element Mech.
Filter
Indicator *** (8 PSID)
Combination Fixed Temp at 65°C(149°F)
R1 Float/Temp. SW 877501 Close at Low Level
N.O. Float Up And/Or 68°C(149°F) (N.O.)
Combination Fixed Temp at 68°C(149°F)
Valve NFPA Nominal R2 Float/Temp. SW 877502 Open at Low Level
Ordering Circuit N.C. Float Up And/Or 68°C(149°F) (N.C.)
Model Mounting Flow LPM
Code Symbol
Number Pad (GPM) Description *Heat rejection data is based on 100SSU oil leaving the cooler 4°C (40°F)
Double A B higher than the ambient air temperature used for cooling.

B D3W1CN** D05 78 (20)



(Spr. Ctr) P T Option "A" available from .6 KW (7.5 HP) thru 18.5 KW (25 HP).
Option "C" not available with option "A" or "B".
Double A B

C D3W4CN** D05 57 (15) ***Based on max. 136 LPM (36 GPM) w/ 150SUS oil.

(Spr. Ctr)

P T

5 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

Dimensions – Basic
Shown with “Omit” Option Manifold
Inch equivalents for millimeter dimensions are shown in (**)
Motor Motor Description Dimension
Code KW(HP)-RPM-Frame-Typ e "A" "B

451
M 5.6(7.5)-1800-213TC-TEFC N/A
(16.6)
273.1
(10.75)
"B" 451
N 7.5(10)-1800-215TC-TEFC N/A
(17.2)

451 48
P 11.2(15) -1800-254TC-TEFC
(20.0) (1.88)
231.7
FILTER (9.12) 597 48
BREATHER S 14.9(20)-1800-256TC-TEFC
(STANDARD)
(23.5) (1.88)

579 51
Q 18.6(25)-1800-284TC-TEFC
(22.8) (2.0)
819.2
PUMP COMPENSATOR

(32.25)
CONTROL

SAE-20 620 51
R 22.4(30)-1800-286TC-TEFC
PUMP PRIME

SPARE RETURN (24.4) (2.0)


PORT
627 144
T V 29.8(40)-1800-324TC-TEFC
P
(24.7) (5.69)
SAFETY RELIEF
DO NOT ADJUST

SUPPLY PORT
72.9 736.6 SAE-16 ORB
(2.87) (29.0)
838.2
(33.0) RETURN PORT
914.4 SAE-20 ORB
(36.0)
"O" OPTION
SAE-20 SPARE RETURN MANIFOLD
PORT (AVAILABLE WITHOUT
RETURN FILTER ONLY)

SAFETY RELIEF VALVE


MAINTAIN 31 BAR (450 PSI) REMOTE PUMP
ABOVE PUMP COMPENSATOR COMPENSATOR
CONTROL SETTING CONTROL ADJUSTMENT

TOPPLATE PUMP CASE "A"


LIFTING EYE FILL PORT
TYP.-3 PLCS.
PRESSURE GUAGE
WITH SHUT-OFF VALVE
CLEAN-OUT
COVER

V-PAK

FULL MARK

725
(28.56)
432
(17.0)
Ø15.9 (.625)
TYP. -4 PLCS.

63.5
SAE-12 952.5 (2.50) 68.6
TANK DRAIN (37.5) 711.2 (2.70)
990.6 (28.0)
(39.0)
769.5
(31.36)
878.6
(34.59)

6 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

S5 Option Manifolds
Inch equivalents for millimeter dimensions are shown in (**)

S5
SUBPLATE OPTION
FOR USE WITH D3W VALVE
(NFPA D05)

T P

71.4
(2.81)

38.1
(1.50)
A-D03 B-D03
B-D05 A-D05

26.9
(1.06) 54.1
(2.13)
SUPPLY RETURN
PORT PORT
SAE-12 SAE-12
X

RETURN P T "A"
PORT X P A PORT
SAE-12 SAE-10
T B "B"
PORT
SAE-10
RETURN D05
X MNTG
PORT
SURFACE
SAE-12
PUMP
SUPPLY

7 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

M53/M55 & M82 Option Manifolds


Inch equivalents for millimeter dimensions are shown in (**)

"M53/M55 Option" RETURN


PORT
SAE-12

X
P T
A

"A"&"B"PORTS

3 AND 5 STATIONS
B

SAE-8

T
A

P
G B
"G" 1.25
SAE-6 D05
MNTG
SURFACE

PUMP
SUPPLY
M53 AND M55
3 AND 5 STATION MANIFOLD OPTIONS

FOR USE WITH NFPA D05 VALVES 83.0


(3.25)
PER STATION

3 AND 5 B A
STATION
AVAIL. G
165.0 83.0
(6.5) (3.25)
B A

40.0
17.5 (1.56)
(0.69) 54.0
(2.12)

"M82 Option"
RETURN
PORT
SAE-16
X

P
T

"Y"
SAE-8
Y
B
A

"A"&"B"PORTS

(2 STATIONS)
-16 SAE
B
A

"G"
G

-6 SAE
T P
P
T

46.0
(1.81)
M82
2 STATION MANIFOLD OPTION

FOR USE WITH NFPA D08 VALVES


SAE-8 "Y" PORT, NO "X" PORT

B A

266.7
(10.50) 133.4
G
(5.25)
B A

50.8
26.9 (2.00)
(1.06)
66.8
(2.63)

8 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

V-Pak - Compensator Options


Inch equivalents for millimeter dimensions are shown in (**)

"B" OPTION
"OMIT" OPTION T
HIGH LOW
SINGLE PRESSURE
SINGLE PRESSURE PSI PSI LOW SOL
REMOTE COMPENSATOR STANDBY
REMOTE COMPENSATOR
W/LOW PRESS STANDBY

P T HIGH
SOL
P
P

SAE SOLENOID IS LOW WATT


-6 WITH DIN.43650 CONNECTOR
AND MANUAL OVERRIDE
PUMP CASE AUX.VENT PORT (SAE-6)
PRE-FILL PORT PUMP CASE LOW PRESS.STANDBY(N.O.)
PUMP COMPENSATOR PRE-FILL PORT ENERGIZE TO BUILD PRESSURE
CONTROL ADJUSTMENT
PUMP COMPENSATOR
CONTROL ADJUSTMENT
HI LO
SOL SOL

HI
LO

"C" OPTION "D" OPTION


T T
BI-PRESSURE HIGH LOW HIGH LOW
PSI PSI
BI-PRESSURE PSI PSI LOW SOL
REMOTE COMPENSATOR REMOTE COMPENSATOR STANDBY
W/LOW PRESS STANDBY

HIGH HIGH
SOL SOL
P P

SOLENOID IS LOW WATT SOLENOIDS ARE LOW WATT


WITH DIN.43650 CONNECTOR WITH DIN.43650 CONNECTOR
AND MANUAL OVERRIDE AND MANUAL OVERRIDE
PUMP CASE PUMP CASE
PRE-FILL PORT HIGH PRESS.SOLENOID (N.O.) PRE-FILL PORT HIGH PRESS. SOLENOID (N.O.)
ENERGIZE FOR HIGH PRESSURE ENERGIZE FOR HIGH PRESSURE

PUMP COMPENSATOR LOW PRESS. STANDBY (N.O.)


HIGH PRESS.CONTROL ENERGIZE FOR LOW PRESSURE
HI LO HI LO
SOL SOL SOL SOL

HI HI

LO LO

PUMP COMPENSATOR
PUMP COMPENSATOR HIGH PRESS. CONTROL
LOW PRESS.CONTROL
PUMP COMPENSATOR
LOW PRESS. CONTROL

SAE-6
"E" OPTION 37˚ FLARE
P T
PROVISION FOR
CUSTOMER SUPPLIED
P
REMOTE COMPENSATOR

PUMP COMPENSATOR
T PRESSURE (INLET) PORT
PUMP COMPENSATOR
TANK (RETURN) PORT

PUMP CASE SAE-6 37˚ FLARE "P" & "T" PORTS


PRE-FILL PORT ATTACH POINTS FOR CUSTOMER
SUPPLIED REMOTE COMPENSATOR

9 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Accessory Options Volume Control
Series V-Paks

HEAT EXCHANGER
PRESSURE SWITCH
RETURN FILTER

BREATHER MULTI-STATION
MANIFOLD

PRESSURE FILTER
TEMP/LEVEL
SWITCH
TEMP. SWITCH

EXAMPLE OF VARIOUS
ACCESSORIES INSTALLED
FOR REFERENCE ONLY

SCHEMATIC - BASIC UNIT


WITH ACCESSORIES

M
SEE
COMPENSATOR
OPTIONS

SEE MANIFOLD
A B OPTION OPTIONS
P T

H L N

SEE
M M M COMPENSATOR
OPTIONS
SEE R*
COMPENSATOR
OPTIONS

SAE
X
-12

C OPTION HYDRAULIC SCHEMATIC

Option A Cooling Loop (0.6 KW (0.8 HP) Removal) Option K Pump Outlet Check Valve
Option B Cooling Loop (1.1 KW (1.5 HP) Removal) Option L Bypass Check-Return Ht. Ex. Only
Option C System Cooling/Filter Loop (3.4 KW (4.5 HP) Removal) Option N Return Filter - Dual Element
Option H Pressure Filter Option R* Combination Level/Temperature Switch

10 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

Dimensions - Accessories
V8 reservoir with "Omit" manifold shown
Inch equivalents for millimeter dimensions are shown in (**)
Ordering Note: Units with PVP76 pumps and requiring options "A", "B" or "C" can only be ordered with
V8 (302.8 L/80 Gal.) reservoir.

HEAT REMOVAL OPTION A .6 KW (.80 HP*)

HEAT REMOVAL OPTION B 1.1 KW (1.5 HP*)

*Performance data are based on 100SSU oil leaving the cooler 4°C (40°F) higher than the ambient air temperature used for cooling.

PUMP COMPENSATOR

PUMP COMPENSATOR
CONTROL

CONTROL
PUMP PRIME

PUMP PRIME
T T

P P

SAFETY RELIEF SAFETY RELIEF


DO NOT ADJUST DO NOT ADJUST

129.8
(5.11)
85.9
(3.38)

V-PAK V-PAK

Option "A" Cooling Loop Option "B" Cooling Loop


5.6 KW - 18.6 KW (7.5 HP - 25 HP) ONLY

11 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Volume Control
Series V-Paks
Technical Information

Dimensions - Accessories
V8 reservoir with "Omit" manifold shown
Inch equivalents for millimeter dimensions are shown in (**)
Ordering Note: Units with PVP76 pumps and requiring options "A", "B" or "C" can only be ordered with
V8 (302.8 L/80 Gal.) reservoir.

HEAT REMOVAL OPTION C 3.4 KW (4.5 HP*)

*Performance data are based on 100SSU oil leaving the cooler 4°C (40°F) higher than the ambient air temperature used for cooling.

PUMP COMPENSATOR
CONTROL
PUMP PRIME
OUT

IN

SAFETY RELIEF
DO NOT ADJUST

415.3
(16.35)

V-PAK

Option "C" System Cooling/Filter Loop

12 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

Dimensions - Accessories
V8 reservoir with H, N & R Options shown
Inch equivalents for millimeter dimensions are shown in (**)

"H" OPTION FILTER

PUMP COMPENSATOR
CONTROL
GPM
GAL

PSI
Fluidpower

HYDRAULIC PUMP/MOTOR DIVISION


Systems

OTSEGO MICH 49078 USA


MODEL NUMBER

TANK

PRESSURE MAX
PUMP FLOW
S/N
T
OPTION "R" P
COMBINATION TEMP/LEVEL SWITCH SAFETY RELIEF
DO NOT ADJUST

(1/2 NPT ELEC. CONN.)

"N" OPTION FILTER

470
(18.5)

13 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

Performance Data- Maximum Working Pressure

**** Represents maximum operating pressure with pump/motor combination. This will be the maximum
relief valve or compensator setting.
**** Represents maximum operating pressure with pump/motor combination. When used on power unit
products this will represent a 207 bar (3000 psi) relief valve or compensator setting.

V-Pak - Pump/Motor Combinations Maximum Operating Pressure


Bar (PSI)

FLOW LPM (GPM) 5.6 KW 7.5 KW 11.2 KW 14.9 KW 18.6 KW 22.3 KW 29.8 KW
PUMP
@ 1725 RPM (7.5 HP) (10 HP) (15 HP) (20 HP) (25 HP) (30 HP) (40 HP)

75.2 98.6 146.9 194.4 239.2


PVP33 41.6 (11.0)
(1090) (1430) (2130) (2820) (3470)

72.4 95.1 141.3 186.8 230.3


PVP33 43.5 (11.5)
(1050) (1380) (2050) (2710) (3340)

69.6 91.7 135.8 180 222


PVP33 45.4 (12.0)
(1010) (1330) (1970) (2610) (3220)

66.9 88.3 131 173.7 213.7


PVP33 47.3 (12.5)
(970) (1280) (1900) (2520) (3100)

64.8 85.5 126.9 167.5 206.8 247.5


PVP33 49.2 (13.0)
(940) (1240) (1840) (2430) (3000) (3590)

62.7 82.7 122.7 162 200 239.2


PVP33 51.1 (13.5)
(910) (1200) (1780) (2350) (2900) (3470)

60.7 80 118.6 157.2 193.7 232.4


PVP33 52.9 (14.0)
(880) (1160) (1720) (2280) (2810) (3370)

59.3 77.9 115.1 152.4 188.2 224.8


PVP33 54.8 (14.5)
(860) (1130) (1670) (2210) (2730) (3260)

57.2 75.2 111.7 147.5 182.7 218.6


PVP33 56.7 (15.0)
(830) (1090) (1620) (2140) (2650) (3170)

14 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Volume Control
Series V-Paks
Technical Information

Performance Data- Maximum Working Pressure

**** Represents maximum operating pressure with pump/motor combination. This will be the maximum
relief valve or compensator setting.
**** Represents maximum operating pressure with pump/motor combination. When used on power unit
products this will represent a 207 bar (3000 psi) relief valve or compensator setting.

V-Pak - Pump/Motor Combinations Maximum Operating Pressure


Bar (PSI)

FLOW LPM (GPM) 5.6 KW 7.5 KW 11.2 KW 14.9 KW 18.6 KW 22.3 KW 29.8 KW
PUMP
@1725 RPM (7.5 HP) (10 HP) (15 HP) (20 HP) (25 HP) (30 HP) (40 HP)

53.8 70.3 103.4 137.9 170.3 203.4 270.2


PVP48 58.6 (15.5)
(780) (1020) (1500) (2000) (2470) (2950) (3920)

53.1 68.9 101.4 133.8 166.2 198.6 263.4


PVP48 60.5 (16.0)
(770) (1000) (1470) (1940) (2410) (2880) (3820)

57.1 67.6 98.6 130.3 162 193.1 256.5


PVP48 62.4 (16.5)
(750) (980) (1430) (1890) (2350) (2800) (3720)

50.3 65.5 96.5 126.9 157.9 188.2 249.6


PVP48 64.3 (17.0)
(730) (950) (1400) (1840) (2290) (2730) (3620)

49 64.1 93.8 124.1 153.8 183.4 243.4


PVP48 66.2 (17.5)
(710) (930) (1360) (1800) (2230) (2660) (3530)

48.3 62.8 91.7 121.3 150.3 179.3 237.9


PVP48 68.1 (18.0)
(700) (910) (1330) (1760) (2180) (2600) (3450)

46.9 61.4 89.6 118.6 146.9 175.1 232.4


PVP48 70.0 (18.5)
(680) (890) (1300) (1720) (2130) (2540) (3370)

46.2 60 87.6 115.8 143.4 171 226.8


PVP48 71.9 (19.0)
(670) (870) (1270) (1270) (2080) (2480) (3290)

45.5 58.6 86.2 113.1 140 167.5 222


PVP48 73.8 (19.5)
(660) (850) (1250) (1640) (2030) (2430) (3220)

44.1 57.2 84.1 110.3 137.2 163.4 216.5


PVP48 75.7 (20.0)
(640) (830) (1220) (1600) (1990) (2370) (3140)

43.4 56.5 82 108.2 134.4 160 212.4


PVP48 77.6 (20.5)
(630) (820) (1190) (1570) (1950) (2320) (3080)

42.7 55.2 80.7 106.2 131.7 157.2 206.8


PVP48 79.4 (21.0)
(620) (800) (1170) (1540) (1910) (2280) (3000)

42.1 54.5 79.3 104.1 128.9 153.8 203.4


PVP48 81.3 (21.5)
(610) (790) (1150) (1510) (1870) (2230) (2950)

41.4 53.8 77.9 102 126.2 151 199.3


PVP48 83.2 (22.0)
(600) (780) (1130) (1480) (1830) (2190) (2890)

40.7 52.4 75.8 100 124.1 147.5 195.8


PVP48 85.1 (22.5)
(590) (760) (1100) (1450) (1800) (2140) (2840)

40 51.7 74.5 97.9 121.3 144.8 191.7


PVP48 87.0 (23.0)
(580) (750) (1080) (1420) (1760) (2100) (2780)

15 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Volume Control
Series V-Paks
Technical Information

Performance Data- Maximum Working Pressure

**** Represents maximum operating pressure with pump/motor combination. This will be the maximum
relief valve or compensator setting.
**** Represents maximum operating pressure with pump/motor combination. When used on power unit
products this will represent a 207 bar (3000 psi) relief valve or compensator setting.

V-Pak - Pump/Motor Combinations Maximum Operating Pressure


Bar (PSI)

FLOW LPM (GPM) 5.6 KW 7.5 KW 11.2 KW 14.9 KW 18.6 KW 22.3 KW 29.8 KW
PUMP
@ 1725 RPM (7.5 HP) (10 HP) (15 HP) (20 HP) (25 HP) (30 HP) (40 HP)

20.7 31.7 55.2 78.6 100 121.3 167.2


PVP76 90.8 (24.0)
(300) (460) (800) (1140) (1450) (1760) (2425)

20 31 53.4 75.8 96.5 117.2 160.3


PVP76 94.6 (25.0)
(290) (450) (775) (1100) (1400) (1700) (2325)

18.6 29.6 52.4 73.8 94.5 113.8 155.8


PVP76 98.4 (26.0)
(270) (430) (760) (1070) (1370) (1650) (2260)

17.9 29.3 50.3 71 91.4 113.8 155.8


PVP76 102.2 (27.0)
(260) (425) (730) (1030) (1325) (1650) (2260)

17.6 27.6 48.3 68.3 88.3 106.5 144.1


PVP76 106.0 (28.0)
(255) (400) (700) (990) (1280) (1545) (2090)

17.2 26.9 46.5 65.5 86.9 104.5 140.7


PVP76 109.8 (29.0)
(250) (390) (675) (950) (1260) (1515) (2040)

26.9 45.5 63.8 83.4 103.4 137.9


PVP76 113.6 (30.0) -
(390) (660) (925) (1210) (1500) (2000)

25.9 43.8 61.4 80.7 97.9 132.4


PVP76 117.3 (31.0) -
(375) (635) (890) (1170) (1420) (1920)

24.8 42.7 60.3 78.6 95.1 128.6


PVP76 121.1 (32.0) -
(360) (620) (875) (1140) (1380) (1865)

23.4 41.4 57.9 75.8 92.4 124.8


PVP76 124.9 (33.0) -
(340) (600) (840) (1100) (1340) (1840)

22.4 39.6 56.9 74.1 90.3 121.7


PVP76 128.7 (34.0) -
(325) (575) (825) (1075) (1310) (1765)

21.4 36.5 55.2 70.7 87.9 118.9


PVP76 132.5 (35.0) -
(310) (530) (800) (1025) (1275) (1725)

20.7 35.2 53.1 68.9 84.8 111


PVP76 136.7 (36.0) -
(300) (510) (770) (1000) (1230) (1610)

16 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

Performance Data
Fluid Standard Hydraulics Oil 100 SSU @ 49°C (120°F)

Flow, Horsepower and Efficiency Charts

PVP33 @ 1800 RPM LPM GPM PVP48 @ 1800 RPM KW HP


LPM GPM Volumetric Efficiency 100 90.9 24 44.8 60.0
100 75.7 20
Flow cy
90
Efficien

Efficiency - %
Efficiency - %

90 68.2 18 79.5 21
Overall Efficiency
80 60.6 16 80 68.1 18 33.6 45.0
Flow
70 53.0 14

Flow
70 60.6 16

Power
60 45.4 12

r
we
KW HP
60 45.4 12 22.4 30.0
Flow

Po
50 37.9 10 29.8 40.0

ow
50 34.1 9

Fl
30.3 8 low 23.9 32.0
ll F

ll
Fu
Fu 22.7 6 11.2 15.0
Power

22.7 6
r at 17.9 24.0
we
Po 11.4 3
15.1 4
ut
11.9 16.0
d Power
In
p Compensate
7.6 2 6.0 8.0 0 0 0 0
wer
Compensated Po Bar 0 69 138 207 275
0 0 0 0 PSI 0 1000 2000 3000 4000
Bar 0 69 138 207 275
PSI 0 1000 2000 3000 4000
Pressure
Pressure

NOTE: The efficiencies and data in the graph are


PVP76 @ 1800 RPM good only for pumps running at 1800 RPM and
LPM GPM Volumetric Efficiency KW HP stroked to maximum. To calculate approximate
100 227.2 60 119.4 160.0 horsepower for the other conditions, use the following
formula:
Overall Efficiency
Efficiency - %

75 170.4 45

Flow
89.5 120.0
HP =
[ Q x (PSI)
1714 ] + (CHp)
Power
Flow

50 113.6 30 59.7 80.0


Actual GPM is directly proportional to drive speed
and maximum volume setting. Flow loss, however, is
w er a function of pressure only.
Po
w 29.8 40.0
Flo
56.8 15
ll
Fu
WHERE:
Compensated Power Q = Actual Output Flow in GPM
0 0 0 0
Bar 0 69 138 207 275 PSI = Pressure at Pump Outlet
PSI 0 1000 2000 3000 4000
CHp = Input Horsepower @ Full Compensation @
Pressure
1800 RPM (from graph read at operating
pressure)

NOTE: Maximum input HP to the pump may exceed


electric motor drive capability. Select motor size (HP)
to exceed application requirements (HP).

17 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Technical Information Volume Control
Series V-Paks

AIR COOLED

HORSEPOWER REMOVED
OIL HEAT EXCHANGER

BY COOLER KW (HP)
227 & 303 LITER (60 & 80 GALLON) OPTION "G"
14.9
(20)

7.5
(10)

3.7
(5) 26 30 34 38 57 76 95 114 151 189 OIL PRESSURE DROP
(7) (8) (9) (10) (15) (20) (25) (30) (40) (50)
AT 100 SSU
OIL FLOW-LPM (GPM)
= .34 BAR (5 PSI)
"G" - Return Line HT. EX. 30 LPM - 136 LPM (8 GPM - 36 GPM MAX.) = .69 BAR (10 PSI)
= 1.0 BAR (15 PSI)
Performance data is based on 100 SSU oil leaving the cooler = 1.4 BAR (20 PSI)
4.4°C (40°F) higher than the ambient air temperature used for cooling.

RESERVOIR SIZE LITERS (GALLONS)


Heat removal is based on static
303 (80)
ambient air of 29°C (85°F) and max. oil
.89 (1.2) temperature of 57°C (135°F).
KW (HP) REMOVAL

18 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA
Catalog HY28-2661-CD/US Low Profile Power Units
Installation Information Volume Control
Series V-Paks

Operating Notes Fluid Recommendations


• Jog the electric motor once and verify that the Premium quality hydraulic oil with a viscosity range
electric motor is rotating in the same direction as between 150-250 SSU (30-50 cst.) at 38°C (100°F).
the arrow on the electric motor housing. If direction Normal operating viscosity range between 80-1000 SSU
is incorrect, reverse two of the three leads on a 3- (17-180 cst.). Maximum start-up viscosity is 4000 SSU
phase electric motor. (1000 cst.).
• V-Pak power units are tested and pressure control NOTE: Consult Parker when exceeding 71°C (160°F)
valves are factory preset. If adjustments are needed, operation. Oil should have maximum anti-wear
follow the procedure below: Begin adjusting relief properties, rust and oxidation treatment.
valve and pump compensator control valve to
increase pressure gradually. (NOTE: Always set relief
valve 28-31 bar (400-450 psi) higher than pump
compensator pressure control valve or severe
overheating will occur.)
Filtration
For maximum pump and system component life, the
• If pump fails to prime, vent pump discharge to system should be protected from contamination at a
atmosphere to establish fluid flow. level not to exceed 125 particles greater than 10
microns per milliliter of fluid. (SAE Class 4 / ISO 16/
• Reservoir temperature should not exceed 66°C
13.) Due to the nature of variable displacement pumps,
(150°F). System reliability and component service
variations in pump inlet conditions, fluid acceleration
life will be reduced when system is operated at
losses, system aeration, and duty cycle must be
higher temperature.
carefully considered before specifying suction line
• Clean fluid = improved system reliability and longer filtration. Contact your Parker representative for
component service life, change filter elements assistance.
whenever filter indicators indicate a dirty element
condition.
• It is recommended that every 4,000 operating hours
or once a year, whichever occurs first, the filler/
breather cap and suction strainer should be
replaced.

19 Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA