You are on page 1of 1

Steel Grade,fy 500 N/mm2 Depth of found,H= 2.

5 m
Concrete Grade 20 N/mm2
Unit weight of RCC 2.5 t/m2
Unit weight of Earth 1.8 t/m2
Footing Thicknees,D 0.4 m Effective Thickness of footing= 0.340 m
400

F1 d= 0.15
150
m 340 mm

Initial Size Of Footing Lx 2.30 m LZ 2.30 m


Size of Footing Provided Lx 2.3 m LZ 2.3 m
Pedestal Ht above NGL. m
Column Length(Cx) 0.5 m P3= 20.5074375 t (Filling Weight)
Column Width(Cz) 0.4 m P2= 5.29 t (Footing Self Weight)
Footing Weight P1= 32 t (Load From STAAD)
11.00 Pnet=P1+P2
Total Vertical Load(With Surcharge Load), P= 57.7974375 T SBC t/m2 +P3= 57.7974375 t

Guiding Pressure, Q 10.93 t/m2 ok (As Guiding base pressure is less than SBC)
109.2579 KN/m2

Check:

(1) One Way Shear/ Wide Beam Shear


Shear Force at adistance "d" from colum face,
Vx=(Lx/2-Cx/2-d)*q*Lz 153.2889 KN
Shear Stress, ζ= Vx/(Lz*d) 196.0216 KN/m2
0.196022 N/mm2 Ast minimum = 0.12 %
For %age of tension steel, So, from Table 19 of IS 456-2000,for
M25 Grade of concrete ,Design shear strength ζc = 0.328307 N/mm2 Ast PROVIDED= 0.23453735 % b 1000 mm
AS ζ<ζc Depth is Safe d 340
(2) Two Way Shear/ Punching Shear ζc=
Vertical Load,P= 577.9744 KN (frOM Table19 of IS 456,2000) 0.15 0.28
Punching Area=(Cx+d)*(Cz+d) 0.6216 m2 0.2345373499 X
Punching Perimeter=(2*Cx+2*Cz+4*d) 3.16 m 0.5 0.48
Punching Stress, ζp'= P-q*(Cx+d)*(Cz+d)/(2*Cx+2*Cz+4*d)*d 474.7391 KN/m2 By Interpolation x= 0.328307057
0.474739 N/mm2 (Where x= ζc for provided reinf.)
Permissible Punching Stress, ζp,as per IS 456:2000 =
0.25sqrt(fck) 1.118034 N/mm2 d/2
AS ζp'<ζp Depth is Safe

Reinforcement
Reinforcement Along X-Direction/ Parellel to Lx d/2 d/2
Moment at face of Column, Mz=q*Lz(Lx/2-Cx/2)^2/2 101.7737 kN-m For a beam width=Lz= 2.3 m
44.24946 kN-m/m (For Unit width of beam)
Ultimate Moment=1.5*Mx 66.37418 kN-m/m
b= 1000 mm
Let, x is neutral axis depth, d/2
x/d=1.2-sqrt((1.2^2-(6.68Mu/fck*b*d^2)) 0.082759
Lever Arm, Z=d*(1-0.416*x/d) 328.2945 PUNCHING CHECK.
Ast= Mu/(0.87*fy*z) 712.6608 mm2 Provide Ast Calculated
Let 12 dia bar is used,
158.6168 c/c DIA OF BAR USED:
Ast(min), 0.12% 0.18 12
let 10mm dia bar is used, 436111.1 c/c CX
So, Provide, 12 Φ@ 100 C/C

Reinforcement Along Z-Direction/ Parellel to Lz


Moment at face of Column, Mx=q*Lx(Lz/2-Cz/2)^2/2 113.3961 kN-m For a beam width=Lx= 2.3 m
49.30263 kN-m/m (For Unit width of beam) CZ
LZ
Ultimate Moment=1.5*Mx 73.95395 kN-m/m
b= 1000 mm
Let, x is neutral axis depth,
x/d=1.2-sqrt((1.2^2-(6.68Mu/fck*b*d^2)) 0.092604
Lever Arm, Z=d*(1-0.416*x/d) 326.9021
Ast= Mu/(0.87*fy*z) 797.427 mm2 Provide Ast Calculated COLUMN
Let 12 dia bar is used,
141.7559 c/c DIA OF BAR USED:
Ast(min), 0.12% 0.18 12 LX
let 10mm dia bar is used, 436111.1 c/c
So, Provide, 12 Φ@ 100 C/C
FOOTING