Design calculation sheet

Project no.: Date: Sheet no.: of Computed by:

Checked by:
Subject:
Approved by:

Design of Isolated Footing UnderVertical Load Only - According to ACI 318-02


Net bearing capacity = 18.32 t/m2
Conc. cylinder strength of PC footing (f 'c PC) = 250 kg/cm2
Conc. cylinder strength of RC footing (f 'c RC) = 350 kg/cm2 Steel yield stress (f y) = 4200 kg/cm2
Soil density (Gs) = 1.85 t/m3 b1 1.8

Footing ID: F3 e t F3 e t

Ultimate column load = 400.00 t A1 = 0.28 m2


Service column load = 290.00 t A2 = 19.14 m2
400.0 t
Column Dimensions
Length = 80.00 cm
Width = 35.00 cm
trc
Footing Dimensioning tpc
Required bearing area on soil = 17.41 m2
tpc Lrc tpc

Required Plain Concrete Dimensions Chosen Plain Concrete Dimensions Reinforced Concrete Dimensions
Length = 4.45 m Length = 5.00 m Length = 4.40 m
Width = 4.00 m Width = 5.00 m Width = 4.40 m
Thickness = 0.30 m Thickness = 1.00 m
Depth = 0.90 m
Working stress under P. C. footing = 12.15 t/m2 (Safe)
Ult. stress under PC footing = 16.66 t/m2
Working stress under R. C. footing = 15.63 t/m2
Max. Ult. bending moment (Sect. III-III) = 3.75 mt (Safe)
Max. Ult. bending moment (Sect. IV-IV) = 3.75 mt (Safe)
Nominal bearing strength of column = 541.45 t (Safe)
Nominal bearing strength of footing = 1082.90 t (Safe)

Footing Reinforcement III I


Ultimate bearing pressure = 21.44 t/m2 tpc
Max. Ult. bending moment (Sect. I-I) = 44.52 m t/ m' m tm t II
Max. Ult. bending moment (Sect. II-II) = 56.34 m t/ m' m tm t
Wrc
Bar sizes to be chosen are ( 12, 16, 20, 22, 25, 32, 40) IV
tpc
As I-I = 18.0 cm2 As I-I(chosen) = 9 f 16 / m'
As II-II = 18.0 cm 2 As II-II(chosen) = 9 f 16 / m'
As min 18 cm2 tpc Lrc tpc

Check Wide Beam Action ( Shear )


Area subject to Shear stress = 4.95 m2
Maximum allowable footing resistance for shear = f Vn = 0.75 * (( f ' c) ^ 0.5 * b *d / 6)= 292.85 t
Ultimate shearing force acting on footing (Vu) = 106.13 t < 292.85 t (Safe)

Check Two Way Action (Punching)


Area subject to punching shear = 17.24 m2
Perimeter resisting punching shear (bo) = 5.90 m
Maximum allowable footing resistance to punching is the Least of :
1- 0.75*((f 'c)^0.5*bo*d)/3 = 785.36 t
2- 0.75*((1+2/bc)*(f 'c)^0.5*bo*d/6) = 736.27 t
3- 0.75*(((as*d/bo)+2)*(f 'c)^0.5*bo*d/12) = 1590.7 t

where, bc is the ratio of long side to short side of the column, concentrated load or reaction area
and, as is 40 (for interior columns)

525398016.xls Rev. 1.0 1/2 05/25/2021


Punching Force acting on Footing (Vps) = 369.54 t < 736.27 t (Safe)

525398016.xls Rev. 1.0 2/2 05/25/2021