ECG Project Name

Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


COLUMN ID :- ( C-2 )

DESIGN CASE :- (D.L+L.L) a Steel grade St.52


Fy = 3.60 t/cm2
1)- APPLIED FORCES :- Fu = 5.20 t/cm2
Mx1 = 5.00 mt
Mx2 = -6.00 mt if Mx2 at the other side put -ve sign
My = 0.00 mt
N = 5.10 t

2)-DIM. OF SECTION :-
Mx
The section is Rolled section IPE 600
bFL.U = 220 mm
tFL.U = 19.0 mm
hWEB = 600 mm
tWEB = 12.0 mm
bFL.L = 220 mm
tFL.L = 19.0 mm

m.nour
3)-COLUMN DATA :- Mx
Total length of column = 8.50 m Y
Lu act.of comp. Flange = 8.50 m bY
Y
Length subject to buckling in plan = 11.10 m tfl
Length subject to buckling out plan = 8.50 m
Length of girder Lg = 11.00 m
Ix (rafter) = 16270.00 cm4 X
X h tw
Base type = Fixed
My
4)- PROPERTIES OF SECTION :-

A = 156.00 cm2 Y

Y = 300.00 cm
X = 110.00 cm
Ix = 92080.00 cm4
Iy = 3390.00 cm4
Sx = 3070.00 cm3
Sy = 308.00 cm3
rx = 24.30 cm
ry = 4.66 cm

5)- CHECK COMPACTNESS :-


dw/tw = 42.833 Web is Compact
C/tf = 5.789 Flange is Compact
The sec is Compact
ECG Project Name
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL

Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.

P.O.Box No. 1167, Cairo 11511, Egypt. M.Nour Sheet No.


6)- CHECK STRESSES :-
fbcx = 0.16 t/cm2
fbcy = 0.00 t/cm2
Fbcy = 2.59 t/cm2
fca = 0.03 t/cm2
a = -1.20
Cb = 0.92
( 20.bf ) / (√ fy ) = 2.319 m
Lumax = 2.319 m
( 1380.Af ) / ( fy.d ) x Cb = 2.46 m
(Lateral torsional buckling of comp.flange) There is L.T.B
Fltb = 0.805 t/cm 2

Fbcx = 0.805 t/cm2


GA = 1 (according to base type)
GB = 7.32
K = 2.10 E.C.O.P (P.61)
Lbin = 23.31 m
Lbout = 8.50 m
lin = 95.93
lout = 182.40
lmax = 182.40 < 180 Unsafe
Fc = 0.23 t/cm 2

fca / Fc = 0.15
Cmx = 0.85
A1 = 1.00
Cmy = 1.00
A2 = 1.00

APPLYING THE INTERACTION EQUATION :

( fca / Fc ) + ( fbcx / Fbcx ) A1 +( fbcy / Fbcy ) A2 = 0.347 < 1.00 SAFE