You are on page 1of 3

ER-26 ECN: 201800355 VER: 22 - 5-14-18

Hold-down Bolting to Resist Shaking


Forces and Couples in Reciprocating
Compressors
Requirements
 1.  To use the torques in the tables, the ultimate strength (Su) of the stud material must equal or exceed 
100,000 psi (690 MPa); higher strength stud material is preferred. In all cases, torque the nuts to stress 
the stud to about 55% of the ultimate strength of the stud material. Torques shown in tables are based on 
100,000 psi ultimate strength material for imperial sizes and 830 MPa ultimate strength material for 
metric sizes. Higher strength materials require higher torques than shown in the tables. Material strength 
and torque are directly proportional. Example: for 120,000 psi (830 MPa) ultimate strength Imperial 
bolting: 120,000 ÷ 100,000 = 1.2 x min. torque for Imperial size from table = required torque for given nut 
size. To use a different stud diameter, consult Ariel for feasibility and torque.
 2.  Compressor frame foot hold-down studs and crosshead guide support foot hold-down studs should be 
as long as possible. Ariel recommends a minimum 12 to 1 length to diameter ratio.

NOTE: Bolting long enough to reach only through the compressor foot and a deck plate or
flange of an I-beam can loosen if not provided with engineered devices to maintain bolt pre-
load.

 3.  Tighten nuts as recommended above  TABLE 1 Crosshead Guide to Support Bolt Torques


to maintain fastener pre-load during 
operation. Ariel also recommends  Bolting Size Bolting Torque
Compressor Model
rolled threads and hardened  inch--TPI lb-ft (N•m)
spherical washers for hold down  JG:A:W:M:P:N:Q, KB100 5/8 - 11 90 (120)
bolting to help compensate for 
fastener to frame bolt surface angular  JGI N/A
misalignment.
JGR:J 3/4 - 10 160 (215)
 4.  Use grade 8 or 9 bolting to hold 
crosshead guides to supports. JGH:E 7/8 - 9 255 (345)

 5.  Re-preserve any fasteners subject to  JGK:T a 1" - 8 380 (515)


corrosion after installation. KBK:T 1" - 14 395 (535)
 6.  Follow lubrication guidelines and  JGC:D:F:Z:U 1-1/4 - 7 770 (1040)
recommended procedures for torque 
accuracy in the appropriate ER- KBZ:U 1-1/4 - 12 780 (1060)
96.2.x series document.
JGB:V, KBB:V 1-1/2 - 6 1340 (1810)

 a.  For JGT compressors with ET crosshead guides, use 7/8”–9 TPI size in TABLE 1 
as the minimum torque.

ER-26, Ver. 22 888-397-7766 (toll free USA & Canada) or Page 1 of 3


740-397-3602 (International)
www.arielcorp.com | arc@arielcorp.com
TABLE 2 Crosshead Guide Support Foot and Frame Foot Hold-down Bolting - Minimum Torques a

Imperial Size
Metric Size (Class 8.8) c
Foot Hold- Hole (basis 100,000 psi)
Compressor
down Bolt Diameter Recom. Min. Nut Recom. Min. Nut
Model
Application b inch (mm) Stud Size Torque e Stud Size d Torqued
inch--TPI lb-ft (N•m) mm x pitch lb-ft (N•m)

JGM:P:N:Q,  Frame f 3/4 (19) 5/8 - 11 100 (140) M16x2 125 (170)


KB100

JG:A Guide Support 3/4 (19) 5/8 - 11 100 (140) M16x2 125 (170)

JG:A:I Frame f 7/8 (22) 3/4 - 10 175 (235) M18x2.5 175 (235)

M20x2.5 250 (340)

JGR:J:W Guide Support  1 (25) 7/8 - 9 280 (380) M22x2.5 340 (460)


and Frame
M20x2.5 250 (340)

JGH:E:K:T Guide Support  1-1/4  (32) 1-1/8 - 7 600 (810) M27x3 630 (850)


and Frame
M30x3.5 850 (1150)

KBK:T Guide Support  1-3/8 (35) 1-1/4 - 7 850 (1150) M30x3.5 850 (1150)


and Frame
M33x3.5 1170 (1590)

JGC:D:F Guide Support  1-1/2  (38) 1-3/8 - 6 1100 (1500) M33x3.5 1170 (1590)


and Frame
M36x4 1500 (2030)

JGZ:U Guide Support 1-1/2  (38) 1-3/8 - 6 1100 (1500) M33x3.5 1170 (1590)

M36x4 1500 (2030)

JGZ:U Frame 1-7/8  (48) 1-3/4 - 5 2300 (3100) M42x4.5 2400 (3250)

JGB:V,  Guide Support  1-7/8  (48) 1-3/4 - 5 2300 (3100) M42x4.5 2400 (3250)


KBZ:U:B:V and Frame
 a.  See #1, "Requirements".
 b.  Crosshead guide support feet and frame feet with counterbored holes are designed to accept 12-point fasteners. To use hex head fasteners 
or studs and nuts instead, a washer thick enough to clear the counterbore is required to provide adequate clearance for the fastener and any 
tooling used for installation. A washer is also recommended for feet with holes that are milled flat.
 c.  Ultimate Strength: 830 MPa (120,000 psi); Yield Strength: 660 MPa (95,700 psi).
 d.  Where two sizes appear, the first is the preferred size, and the second is an alternate size.
 e.  For a stud pitch other than those listed above in the same nominal diameter size, use this formula to determine required torque: Torque = 
(TABLE 2  fastener torque) x (target fastener root area ÷ TABLE 2  fastener root area).
 f.  Crosshead guide supports do not apply to JGM:P:N:Q:I and KB100 frames.

The contents of this document are proprietary and confidential. They are the property of Ariel Corporation and may
not be disclosed, reproduced, or used for manufacture in part or in whole without written permission from Ariel
Corporation.

ER-26, Ver. 22 888-397-7766 (toll free USA & Canada) or Page 2 of 3


740-397-3602 (International)
www.arielcorp.com | arc@arielcorp.com
DATE: VER: ECN: DESCRIPTION:
5-14-18 22 201800355 Page 2, Table 2: Column heading - "Foot Hold-down Bolt Applicationb" was "Foot Hold-down 
Bolt Application"; inserted footnote b - "Crosshead guide support feet and frame feet with 
counterbored holes are designed to accept 12-point fasteners. To use hex head fasteners or 
studs and nuts instead, a washer thick enough to clear the counterbore is required to provide 
adequate clearance for the fastener and any tooling used for installation. A washer is also 
recommended for feet with holes that are milled flat."; subsequent footnotes re-lettered 
accordingly.

ER-26, Ver. 22 888-397-7766 (toll free USA & Canada) or Page 3 of 3


740-397-3602 (International)
www.arielcorp.com | arc@arielcorp.com

You might also like