250MPa

200MPa

150MPa

100MPa

50MPa
3
2

Procedure:
1.- Calculate e.c/r² , with this you choose curve
2.- Calculate Le/r and enter the horizontal axis and go up to the curve (1)
3.- From the curve, go horizontally until you cut the vertical axis and read a value (P/A)
4.- That value (3) is P/A, with A from tables of profiles, calculate P= (P/A) * A
Profesor Dr Miguel X. Rodríguez P. @mxrp (Twitter)