You are on page 1of 2

DynaTrol I-XL

Specification Data Sheet



Architectural Weatherproofing Products
General Purpose Polyurethane Sealant U.S.A. • since 1862

Field-test is required and user must to the width. In joints wider than 3/8”
1. Basic Uses determine suitability. Paintable after 7 days. (9 mm), but not exceeding 1-1/4” (31mm),
Dynatrol™ I-XL is intended for use in the depth should be maintained at 3/8”
expansion and control joints in precast • Lighter colors may exhibit discolor-
ation after extensive UV exposure. (9 mm). For joints wider than 1-1/4”
panels, tilt-up walls, metal curtain walls, (31 mm), please consult Technical
masonry, copings, window and door • Light colors can yellow slightly if
Services.
perimeters, panel bedding, canal and exposed to direct gas fired heating
reservoir joints. elements prior to formation of initial
skin. 5. INSTALLATION
Surface Preparation: Joint surfaces
2. Manufacturer and backer rod must be dry and free
Pecora Corporation PACKAGING of all contaminants such as oil, grease,
165 Wambold Road • 10 fl. oz. (300 ml) cartridges wax, dust, corrosion, tar, asphalt, loose
Harleysville, PA 19438 • 20 fl. oz. (592 ml) sausages aggregate, frost, form-release agents and
Phone: 215-723-6051 • 5-gallon (18.9 L) pails (special order) decorative and protective coatings. Precast
800-523-6688 panels using form release agents other
Fax: 215-721-0286 COLOR than polyethylene film must be sandblasted
Website: www.pecora.com • Black, Limestone, Aluminum Stone,
White, Tan, Beige, Classic Bronze and
or mechanically abraded and blown or
Anodized Aluminum. brushed dust free. Glass, metal and other
nonporous surfaces must be free of any
3. PRODUCT DESCRIPTION coatings and wiped clean with solvent.
Dynatrol™ I-XL is a moisture-curing, Priming: Never a substitute for proper
single-component non-sag polyurethane 4. TecHNicaL DaTa surface preparation, priming is not
sealant. It is designed to maintain an applicable standards: Meets Federal required on glass or anodized aluminum
effective bond and seal between materials Specification TT-S-00230C, Type II, Class and usually not necessary on most other
of similar and dissimilar surfaces, porosities A and ASTM C-920 Type S, Grade NS, common building materials. However,
and coefficients of expansion. Class 25, Use NT, T, M, A, G, O, and I. varieties of brick, natural stone, plastics,
Limitations: Dynatrol™ I-XL should not ASTM C-1247. NSF/ANSI Standard 61, paints, coatings and other treatments of
be used: Section 6 for Joining and Sealing Materials, surfaces often present difficult substrates
• as a cap, heel or toe bead in certain CAN/CGSB-19.13-M87. USDA acceptance to which to adhere. Due to the number
glazing installations with high-perfor- for use inmeat and poultry plants. and unpredictable nature of these
mance glass or plastic. Joint Design: Thewidthofthejoint substrates, a field or laboratory test is
shouldbeaminimumoffour(4)timesthe recommended to determine the adhesion
• in joints less than 1/4” (6 mm) in depth. anticipatedmovement.Thewidthordepth of Dynatrol™ I-XL with or without primer.
• in joints where contact may be made ofthejointshouldnotbelessthan1/4” When priming is indicated, P-75 or P-150
with polysulfide sealants. (6mm).Injointsupto3/8”(9mm)wide, should be used on porous substrates and
• in areas exposed to harsh chemicals. thedepthofthesealantshouldbeequal P-120 on nonporous substrates subject
• on certain architectural paints and
finishes without laboratory or field
typical physical properties
testing.
at 77°F (25°C), 50% RH
• in horizontal joints subject to vehicular
traffic unless protected by a wearing Test Property Value Test Procedure
surface. 100% Modulus (psi) 65 ASTM D412-75
• Although Dynatrol™ I-XL is considered Adhesion-in-Peel (pli) 20 ASTM C920
a paintable sealant, due to variability in Bond Durability-Class 25 Passes ASTM C920
Hardness, Shore A (15-50) 35 ASTM C920
paint products and their raw materials, Service Temperature Range -20°F to +180°F
installation conditions, installation tech- (-29°C to 82°C)
niques, as well as primers, it is required Stain and Color Change Passes ASTM C920
that the contractor who applies paint, Tack Free Time (hrs) 6-12 hrs ASTM C679
pretest paint on sealant to determine Tensile Strength (psi) 175 ASTM D412-75
suitability. Contractor is responsible for Ultimate Elongation (%) 550 ASTM D412-75
test as well as results. Oil based paints Weep and Sag (max 3/16”) Passes ASTM C920
can exhibit a slow/non-curing condition. Weight loss after heat aging (max 10%) Passes ASTM C920
VOC (g/L) <100 ASTM D3960

Since Pecora architectural sealants are applied to varied substrates under diverse environmental conditions and construction situations it is recommended that substrate testing be conducted prior to application.
Specification Data Sheet

to applicable VOC regulations. Consult (27°C), 50% R.H. Consistently higher tem- recaulk. No primer is required. If the
Technical Services for details concerning peratures and/or humidity will shorten this bond has been affected, remove the
primer selection and application. Never shelf life. No shelf life is warranted on bulk sealant, clean and prepare the joint in
use P-75 on nonporous substrates. packages of Dynatrol™ I-XL. accordance with the instructions under
Dynatrol™ I-XL should be applied within Precautions: Contains diisocyanates. “INSTALLATION”.
eight hours after priming; otherwise, it Contact with uncured sealant, with vapors
will be necessary to reprime. Because generated during curing, or with dust 9. TECHNICAL SERVICES
architectural stones such as marble and formed from cured sealant may cause eye,
granite vary considerably in porosity, some Pecora representatives are available to
skin, or respiratory tract irritation or aller- assist you in selecting an appropriate
bleeding of the sealant into the substrate gic reaction. Do not breathe fumes, dusts,
is a possibility. A field or laboratory test to product and to provide on-site application
vapors or mist. Keep container closed. Use instructions or to conduct jobsite
confirm this possibility is recommended. only with adequate ventilation or wear an
Pecora offers complimentary adhesion and inspections. For further assistance
appropriate NIOSH-approved respirator. call our Technical Service Department
stain testing in its laboratory on actual field Harmful if swallowed. Do not swallow
samples of substrate from the jobsite or at 800-523-6688.
or take internally. Do not get in eyes, on
on representative samples from the same skin, or on clothing.Wash thoroughly after
lots. Contact Technical Services for details. handling. Keep away from heat, sparks 10. FILING SYSTEMS
Joint Backing: Backer rod controls the and flame. Repeated contact may, without • http://www.4specs.com
depth of the sealant and allows it to be symptoms, increase susceptibility of these - 07 10 00 Waterproofing
applied under pressure. Use a size that will effects. Refer to Material Safety Data Sheet - 07 92 00 Joint Sealants
compress 25%. (MSDS) for more information.
Denver Foam open-cell polyurethane
or reticulated (soft) polyethylene rod is FOR PROFESSIONAL USE ONLY.
recommended. Closed-cell polyethylene KEEP OUT OF THE REACH
may be used but care must be taken not
to puncture the rod which can cause OF CHILDREN.
outgassing or bubbling/blistering in the
sealant. 6. AVAILABILITY AND
In joints too shallow for backer rod, use a COST
polyethylene bond-breaker tape to prevent Pecora products are available from stocking
three-sided adhesion. distributors nationwide. For the name
Application: Joints should be masked to and telephone number of your nearest
ensure a neat appearance. Sealant should representative, call the number below or
be applied in a continuous operation using visit our website at www.pecora.com.
sufficient pressure to fill the joint and
make complete contact to the joint sides. 7. WARRANTY
Tool the sealant slightly concave using
solvent or dry-tooling techniques. Do not Pecora Corporation warrants its products
tool with soap or detergent and water to be free of defects. Under this warranty,
solutions. we will provide, at no charge, replacement
materials for, or refund the purchase price
Tool Time (initial skin): 3-6 hours at of, any product proven to be defective
77°F (25°C); 50% relative humidity Higher when installed in accordance with our
temperatures and/or humidity will shorten published recommendations and in applica-
this time. tion considered by us as suitable for this
Cleaning: Use mineral spirits to remove product.The determination of eligibility
excess sealant before it cures and to clean for this warranty, or the choice of rem-
equipment. Refer to manufacturers MSDS. edy available under this warranty, shall be Issued to: Pecora Corporation
Product: Dynatrol™ I-XL
Storage Life: One-Part urethanes are made in our sole discretion and any deci-
C719: Pass ____ Ext:+25% Comp:-25%
extremely moisture and heat sensitive. sions made by Pecora Corporation shall
Substrate: Unprimed anodized aluminum and
Dynatrol™ I-XL has a shelf life of twelve be final.This warranty is in lieu of any and glass substrates
months from date of manufacture when all other warranties, expressed or implied, Validation Date: 4/23/13 – 4/22/18
stored in original unopened cartridges or and in no case will Pecora be liable for
sausages at conditions not exceeding 80°F incidental or consequential damages. No. 413-DIXL418 Copyright © 2013

SEALANT VALIDATION
8. MAINTENANCE
If the sealant is damaged and the bond
is intact, cut out the damaged area and
www.pecora.com
p e o p l e • p r o d u c t s • p e r f o r m a n c e

PEC 126 165 Wambold Road, Harleysville, PA 19438


10/14 Phone: 800-523-6688 • 215-723-6051 • FAX: 215-721-0286