You are on page 1of 14

Bill-B (CONTRACT-01)

B-1: B-2: B-3: B-4: B-5: B-6: B-7: B-8:


RESIDEN RESIDEN RESIDENCE RESIDEN OFFICER JR.OFFIC REST WAPDA
CE CE CATEGORY-3 CE 'S ER'S HOUSE PROJEC
CATEGO CATEGO (39- CATEGO HOSTEL HOSTEL (01 NO) T
RY-1 (8- RY-2 (51- BLOCKS / RY-4 (26- CATEGO CATEGO OFFICE
Item BLOCKS BLOCKS 78-UNITS) BLOCKS RY 2 (4 RY-3 (01
No. ITEMS OF WORK UNIT / 8- / 51- / 104- NOS.) NO)
UNITS) UNITS) UNITS)

G.F
F.F
2nd. F
Other
1.1 CIVIL WORKS
I)- Ground Excavation and Filling
Excavation in foundation of buildings including disposal
a) Ordinary soil, soft rock and small boulders not requiring
m³ 1,895 27,919 10,716 5,724 1,978 940 682 2,168
1 blasting (less than 0.5 m)
b) Hard rock and large boulders requiring blasting (greater
m³ 474 18,612 7,144 3,816 1,319 627 455 1,445
than 0.5 m)
Backfilling the excavated stuff in trenches in 150 mm thick
2 m³ 1,139 40,518 9,383 5,476 1,726 878 621 1,640
layers
3 Termite proofing m² 5,012 22,754 33,157 14,881 5,240 2,795 1,665 5,493
II) - Concrete Works
Plain cement concrete (PCC)

1 a) Under ground floors & plinth protection, 10 Mpa (Class D) m³ 457 1,702 2,333 1,644 418 184 119 424

b) Under first floor, 20 Mpa (Class B) m³ 90 544 554 1,367 91 165 24 196
Reinforced cement concrete (RCC)
a) In foundations, 20 Mpa (Class B) m³ 595 3,479 4,890 2,468 865 570 308 1343
2
b) In slabs, beams & columns, 28 Mpa
m³ 1,441 5,775 10,991 5,041 1,638 936 499 1,886
(Class A)
3 Reinforcing steel grade 60, ASTM A615 kg 293,879 750,430 1,323,792 626,200 282,414 158,257 90,731 364,022
III) - Masonry
Precast cement concrete blocks, 10 MPa (Class D)
1 a) Hollow blocks in external walls m³ 365 1,462 2,694 1,435 376 248 152 978
b) Solid blocks in internal walls m³ 851 3,412 6,285 3,348 878 579 356 2,282
2 Vertical damp proof course, 20 mm thick m² 102 58 95 49 138 95 113 311
IV) - External & Internal Finishes
1 Supplying and filling sand under ground floors m³ 214 6,391 1,007 705 1,744 73 49 278
2 Cement sand plaster (1:4) 13 mm thick m² 19,668 88,491 125,943 61,644 22,712 13,476 5,567 33,848
3 Terrazo flooring including skirting m² 3,187 6,647 25,122 5,261 421 3,195 72 1,546
4 Precast cement concrete tiles 8,795
5 Painting doors & windows surfaces m2
6 Plastic emulsion paint 3-coats m² 7,219 53,657 88,370 15,605 9,517 4,461 10,017
7 Weather shield paint 3-coats m² 10,981 26,539 28,204 7,679 3,767 2,795 1,741
8 French polishing on wood works complete in all respects m² 844 3,112 8,822 12,816 588 1,151 244 1,316
9 Distemper 3-coats m2 43 3,694
10 Texture paint m2 7,896
11 White washing 3-coats m2 6,545 5,104 23,099 87 88 35
12 Painting on metal works complete in all respects m² 169 816 2,763 511 19 7 4 59
13 Precast cement concrete paving 50 mm m² 453 2,336 2,898 324 391 1,509
14 Providing and fixing aluminium joint cover (gole) m 466
15 White marble tiles on floors including skirting m² 1,170 5,345 603 1,588 81 375 2,760
16 Ceramic tiles & Skirting m² 2,043 1,858 14,882 556 288 665 961
17 Porcelain tiles m² 789 3,026 2,221 551 763
18 False ceiling comprising plaster of paris m2 2,663
19 False ceiling comprising thermopore sheet m2
20 Khuprail tiles on slant roof m² 505 2,167 2,843 750 362 35 56
21 Plain cement concrete (PCC) flooring oil paint coated m2
22 Vinyle tiles on floor m2
23 Providing and laying lead shield m2
24 Chequered tiles on floor m2
25 Enamel paint 3-coats m2
V) - Joinery and Metal Works
1 Fixed aluminium windows including glazing m² 15 280 2,934 2,104 546 39
2 Fixed aluminium vetilators including glazing m2 17
3 Openable/sliding aluminium windows including glazing m² 325 1,462 2,934 2,104 253 103 970
4 Openable/sliding aluminium ventilators including glazing m2 23
5 Providing and erecting entrance gate Each 8 51 78 52 4 1 1
6 Providing and fixing stair railing complete in all respects m 52 311 435 291 76
7 Solid wood panelled doors m² 422 1,556 4,411 6,408 294 576 122 658
8 Providing and fixing mortice lock in doors Each 202 750 1,911 936 328 250 42 274
9 Providing and fixing wardrobe m² 235 1,756 3,079 1,061 561 937 150
10 Providing and fixing kitchen cabinets m² 65 173 612 284 26 4 7
Bill-B (CONTRACT-01)

B-1: B-2: B-3: B-4: B-5: B-6: B-7: B-8:


RESIDEN RESIDEN RESIDENCE RESIDEN OFFICER JR.OFFIC REST WAPDA
CE CE CATEGORY-3 CE 'S ER'S HOUSE PROJEC
CATEGO CATEGO (39- CATEGO HOSTEL HOSTEL (01 NO) T
RY-1 (8- RY-2 (51- BLOCKS / RY-4 (26- CATEGO CATEGO OFFICE
Item BLOCKS BLOCKS 78-UNITS) BLOCKS RY 2 (4 RY-3 (01
No. ITEMS OF WORK UNIT / 8- / 51- / 104- NOS.) NO)
UNITS) UNITS) UNITS)

11 Providing and fixing MS pipe railing m 423 322 1,417 301 94 65 76 111
12 Providing and fixing steel frame of MS channel section m 180
Providing and fixing poly glass/fibre glass sheet on top of steel
13 m2 60
frame of MS channel section
14 Providing and fixing cooking range of 3 burners Each 8 51 156 104 4 1 1 3
15 Providing and fixing Stainless steel round Pipe m
VI) - Roof Drainage Treatment
1 Roof treatment m² 681 5,161 10,896 6,155 2,603 874 847 2,783
UPVC rain water down-pipe 100 mm dia complete in all
2 m 114 802 1,227 409 63 94 31 96
respects
3 Khuras on Roof (600 x 600 x 150 mm) Each 16 102 156 52 8 8 4 8
4 Bottom Khuras (1200 mm x 600 mm x 115 mm) Each 16 102 156 52 8 8 4 8
VII) - Land Preparation for Lawns
Removal of stones, weeds/undesirable grass and ploughing,
1 m² 1,823 12,006 3,293 2571 13864 3455 2690 3500
leveling and dressing of lawns
VIII) - Miscellaneous
1 Providing and applying 2-coats of hot bitumen m2
2 Providing and fixing pvc water stopper 190 mm m
3 Providing and fixing inlet and outlet sluice valves No.
4 Providing and fixing manhole covers 600mm dia No.
5 Providing and fixing galvanised maleable cast iron steps No.
6 Precast Cement Concrete in Boundary wall for
a) Vertical Member m3
b) Horizontal Members m3
Total of 1.1
Bill-B (CONTRACT-01)

B-1: B-2: B-3: B-4: B-5: B-6: B-7: B-8:


RESIDEN RESIDEN RESIDENCE RESIDEN OFFICER JR.OFFIC REST WAPDA
CE CE CATEGORY-3 CE 'S ER'S HOUSE PROJEC
CATEGO CATEGO (39- CATEGO HOSTEL HOSTEL (01 NO) T
RY-1 (8- RY-2 (51- BLOCKS / RY-4 (26- CATEGO CATEGO OFFICE
Item BLOCKS BLOCKS 78-UNITS) BLOCKS RY 2 (4 RY-3 (01
No. ITEMS OF WORK UNIT / 8- / 51- / 104- NOS.) NO)
UNITS) UNITS) UNITS)

1.2 PUBLIC HEALTH WORKS


I)-Water Supply
Providing, laying, jointing & testing heavy water or steam
quality PPR pipes & specials inside buildings & trenches
a) 20 mm dia m 528 1,479 1,170 650 328 340 200 435
b) 25 mm dia m 976 4,896 2,430 494 440 600 60 625
1
c) 32 mm dia m 200 255 1,170 130 328 360 65 110
d) 40 mm dia m 120 47 82 110
e) 50 mm dia m 136 110 15 75
f) 63 mm dia m 15

Providing and fixing fixtures of toilets (wash basin, C.I.


2 brackets, rubber plug with chain, connection pipe, mirror, Each 48 255 234 52 92 60 22 54
towel rail, soap dishes, glass shelves) complete in all respects

Providing and fixing peet valves complete in all respect


a) 20 mm i/d Each 160 1,020 780 520 80 20 20 45
3
b) 25 mm i/d Each 64 408 312 208 32 8 8 28
c) 32 mm i/d Each 32 204 156 104 16 4 4 18
4 Providing and fixing C.P. bib tap: 13 mm i/d Each 64 306 234 104 40 15 10 30
5 Providing and fixing C.P. Tee stop cocks: 13 mm i/d Each 144 765 702 156 276 180 66 158
Providing and fixing Chromium plated shower mixer 13 mm
6 Each 40 153 156 52 92 60 22 16
complete set
Providing and fixing Stainless Steel sink: 51 cm x 101 cm
7 Each 8 51 78 52 4 1 1 3
including C. I. brackets
Providing and fixing Chromium plated Basin Mixer 13 mm
8 Each 48 255 234 52 84 60 22 54
complete set including connections etc
Providing and fixing C.P. Double bib tap: 13 mm i/d with
9 Each 24 102 156 52 92 60 22 50
Muslim shower complete set
Providing and fixing Sink mixer (Kitchen Sink) 13 mm
10 Each 8 51 78 52 4 1 1 3
complete set including connections
Construction of peet valves or stop cock masonry chamber,
11 Each 40 153 156 52 72 40 22 30
(230 mm x 230 mm inside) of standard design:
II)-SEWERAGE
1 Excavation of trenches for sewerage pipe lines m3 467 1,343 1,106 210 389 151 86 186
2 Providing, lowering & laying 150 mm i/d pipe m 576 1,989 1,365 260 480 186 106 230

Providing and fixing White glazed earthen ware water closet


3 Each 32 153 234 52 84 60 22 40
European style domestic of best quality (with seat cover).

Providing and fixing White glazed earthen ware water closet


4 Each 16 102 39 104 16 5 5 10
squatting type orrisa pattern domestic of best quality

Providing and fixing White glazed earthen ware urinal local


5 Each 12
best quality flat back/corner type
6 Providing and fixing P.Trap 102 mm i/d China-ware Each 16 102 39 104 16 5 5 10

Providing and fixing Floor trap 100 mm x 50 mm (including 50


7 Each 112 459 351 208 96 60 25 87
mm concrete chamber all round): With C.I. grating

Providing and fixing 100 mm i/d gully trap of cement concrete


8 (including 305 mm x 305 mm masonry chamber and C.I. Each 64 204 117 26 20 22 6 13
grating 150 mm x 150 mm)
9 Providing and fixing Toilet paper holders: Chromium plated Each 48 255 234 52 92 60 22 50
10 Providing and fixing flushing cistern & flushing bend Each 48 255 234 52 92 60 27 50
11 Providing and fixing C.P. waste coupling: 32 mm dia Each 48 255 234 78 92 60 22 50
12 Providing and fixing C.P.Bottle trap: 32 mm dia Each 40 255 234 52 92 60 22 50
Providing, laying and jointing µPVC soil pipes class 'D'
including specials (Elbows,Bends & Sockets etc) with
appropriate adhesive solution.
13 a) 50 mm i/d m 56 408 273 130 240 117 67 100
b) 75 mm i/d m 288 1,581 1,365 416 356 565 105 235
c) 100 mm i/d m 144 1,224 624 182 392 360 95 132
d) 150 mm i/d m 18
Providing and fixing C.I. manhole covers with frames:
14 a) 300 mm i/d Each 64 204 117 26 20 22 6 13
b) 450 mm i/d Each 72 255 195 26 24 20 11 16
15 Construction of Manhole 0.7mx0.7mx0.9m Each 72 255 195 26 24 20 11 16
Total of 1.2
B-1.3 INTERNAL ELECTRIFICATION WORK
Supply, installation, wiring, testing and commissioning of fan
1 point. Per Point 152 714 780 728 204 142 52 261
Bill-B (CONTRACT-01)

B-1: B-2: B-3: B-4: B-5: B-6: B-7: B-8:


RESIDEN RESIDEN RESIDENCE RESIDEN OFFICER JR.OFFIC REST WAPDA
CE CE CATEGORY-3 CE 'S ER'S HOUSE PROJEC
CATEGO CATEGO (39- CATEGO HOSTEL HOSTEL (01 NO) T
RY-1 (8- RY-2 (51- BLOCKS / RY-4 (26- CATEGO CATEGO OFFICE
Item BLOCKS BLOCKS 78-UNITS) BLOCKS RY 2 (4 RY-3 (01
No. ITEMS OF WORK UNIT / 8- / 51- / 104- NOS.) NO)
UNITS) UNITS) UNITS)

Supply, installation, wiring, testing and commissioning of light


2 Per Point 792 2,351 2,925 1,612 992 509 244 1,342
Point.
Supply, installation, wiring, testing of 3-pin 5A wall socket
3 Per Point 384 4,590 2,106 806 400 249 101 484
point.
Supply, Installation, wiring, testing and commissioning of
4 m 1,960 8,900 4,300 2,700 2,400 17,000
Power Plugs.
Supply, installation, wiring, testing and commissioning of
5 m 5,700 25,000 9,300 8,320 7,200 5,500
mains with 2-1/7/.085.
Supply, installation, wiring, testing and commissioning of
6 m 14,000 2,340 10,200
mains with 2-1/1.78.
Supply, installation, wiring, testing and commissioning of
7 m 40
mains with 2-1/7/1.70.
Supply, Installation, wiring, testing and commissioning of main
8 m 480 1,020 1,560 540
circuits for chandelier with 2-1/7/0.85.
Supply, Installation, wiring, testing and commissioning of
Fluorescent and other lighting fixture
(a) Hanging light (LED 10W) Each
(b) Ceiling light (LED 10W) Each 352 308 546 264 120 81 222
(c) Bracket light (LED 10W) Each 160 816 1,170 988 384 141 73 480
(d) Wall bracket water tight light 1 x 100W PLC (engergy
Each 176 561 468 130 72 30 15 41
savers)
9 (e) Tube light (1x40W) with Patti, Choke, Starter, tube rod and
Each 80 510 507 494 272 218 73 500
power factor, correction capacitor
(f) Tube light (2x40W) with Patti, Choke, Starter, tube rod and
Each 99
power factor, correction capacitor
(g) Gate light (Energy Saver 24W ) Each 105 156 2
(h) Chandelier (100W) including Energy Saver Each 78
(i) Chandelier (200W) including Energy Saver Each 24 51 12 3 36
(j) Park Light (100W) Each 7 2 3
Supply, Installation, wiring, testing and commissioning of
10 Each 96 459 468 416 120 77 27 216
ceiling fan (56-Inches)
Supply, Installation, wiring, testing and commissioning of
11 Each 56 255 312 312 84 65 25 45
exhaust FAN 12" .
Supply, installation, wiring, testing and commissioning of Flush
12 type water tight 3 pin 5 Amps S.P. Plug-socket recessed in the Each 1
wall
Supply and Installation of Flush type 3 pin 5 Amps S.P. Plug-
13 Each 384 4,590 1,092 806 400 249 100 1200
socket on Metal Board recessed in the wall
Supply, Installation, wiring, testing and commissioning of 2
14 Each 8 51 78 104 12 8 12
ways light point.
Supply and Installation of Flush type 3 pin 15 Amps S.P. Plug-
15 Each 56 255 255 96 60 22 161
socket and switch
Supply and Installation of 20 mm PVC conduit recessed in
16 m 200 200 2000 1,147 200 100 200 700
the wall
Supply, Installation, wiring, testing and commissioning of
17 Intercom system as per drawings including push-buttons and Set 8 4 1 365
the amplifie (2A-220 volts)
Supply, installation, wiring, testing and commissioning of A.C. Each
18 102 78
or D.C. electric Buzzer 200/250 volts
Telephone Junction Box 25 Pairs (TJB) (MTJB): Supply, Each
Installation, testing and commissioning of Telephone junction
19 box 2.50/5, designation level including disconnecting modules 12
for incoming and outgoing telephone cable all necessary
accessories

Supply, Installation, wiring, testing and commissioning of


20 Each 48 255 78 80 2 52 286
Telephone point complete in all respects.
Supply and fixing of 2 module modular metal box in recess
21 with modular cover plate including fixing 1 No. coaxial TV Each 40 204 78 80 62 22 26
outlet connection and all accessories
Supply and Installation of Coaxial TV Cable RG - 6 on the
22 m 200 4,080 780 1,500 620 200 1,040
existing surface/ recessed steel/ PVC conduit
Distribution board, Three phase 40-Amps. 230 volts 1- phase
23 with 1- No. incoming circuit breaker 60 Amps and 230 volts Each 104
O/G circuit breakers S.P: 6A,10A,16A

Distribution board Three phase 60-Amps. 400 volts with 1-No.


incoming circuit breaker 60 Amps. 400 volts O/G circuit Each
24 8 51 78 8 6
breaker S.P :10A,16A,20A,60A

Distribution boards, Three phase 100-A, 35KA, 400V 4 way


25 1- No. incoming circuit breaker and O/G circuit breakers S.P. Each 2 12
10A, 16A, 20A, 60A

Main distribution board, Three phase circuit breaker 125-


A,400V 4 way per phase with 1- No. incoming circuit breaker
125A, 25kA, 400V and O/G three phase circuit breakers: Each 4
26
Bill-B (CONTRACT-01)

B-1: B-2: B-3: B-4: B-5: B-6: B-7: B-8:


RESIDEN RESIDEN RESIDENCE RESIDEN OFFICER JR.OFFIC REST WAPDA
CE CE CATEGORY-3 CE 'S ER'S HOUSE PROJEC
CATEGO CATEGO (39- CATEGO HOSTEL HOSTEL (01 NO) T
RY-1 (8- RY-2 (51- BLOCKS / RY-4 (26- CATEGO CATEGO OFFICE
Item BLOCKS BLOCKS 78-UNITS) BLOCKS RY 2 (4 RY-3 (01
No. ITEMS OF WORK UNIT / 8- / 51- / 104- NOS.) NO)
UNITS) UNITS) UNITS)

26

60-A(400V) Each 8
Distribution board, Three phase 200A, 400V with 1-No.
incoming circuit breaker 3-Phase 200A trip pole MCCB, RC
27 50 KA at 400V and O/G breakers: 3-Phase 125 Amps trip pole Each
MCCB, RC, 35 KA at 400V

Main distribution board, Three phase 160-A,400V 4 way per


phase with 1- No. incoming circuit breaker 160 A, 35KA, 400V
28 Each 2
and O/G: three phase 100-A, 35KA, 400V

Main distribution boad, Three phase 300-A tri-pole 400 V 1-


No. incoming circuit breaker 300-Amps tri-pole MCCB, RC,
29 35KA, 400 V and O/G circuit breaker T.P: 60 A 4 way per Each 1
phase MCCB, RC, 25 KA at 400 V
Main Pannel:
Incoming:
Supply, installation, wiring, testing and commissioning of LT
Panel cubicle type, 600/1000V, 25KA, fitted with 3-Phase 630
Amps tri pole moulded case circuit breaker MCCB, RC, 35 KA,
rated voltage 400 V, having over current & magnetic release
protection, IP54, neutral and earthing bus bars separately,
100x100mm.sq. flush Voltmeter, scale 0-500V, with three way
on off selector switch and 100x100 mm. sq. Ameter,0-500A
scale with 3 way on off selector switch, provision of entery of
30 cables complete with with bus bars as per drawing: No. 1
Outgoing:
(i) 3-Phase 250 Amps tri pole moulded case circuit breaker
MCCB, RC, 35 KA at 400 V, 3 No. (ii)
3-Phase 100 Amps tri pole moulded case circuit breaker
MCCB, RC, 35 KA at 400 V, 12 No.

Supplying,laying and connecting hard drawn earthing copper


31 wire 2.5mm² as earth continuity conductor with any given main m 4,500 21,000 18,500 2,600 8,000 5,000 1,000 2,000
or sub-main in all system of wiring.
Supply, Installation, and connecting copper earth electrodes
32 5/8" dia, 10 ft. long, driven vertically in ground including cost Each 8 51 78 104 8 7 3 14
of construction of manhole deep
Supply, Installation of Earth Connecting Point (ECP): Copper
33 plate 3/4" x 1 1/2" x 12" thick to be installed Each 8 51 78 104 8 7 3 14

Earth Continuity Conductor (ECC): Supply, Installation and


34 connecting of 25mm2 earth continuity copper conductor with m 80 510 780 1,040 200 96 60 300
related accessories
Providing and fixing of SITC of CO 2 Type - 4.5 KG Capacity
35 Each 32 12 8 24
Fire extinguishers fixed on walls
Providing and laying of Cable from Ground Floor Main
Distribution Board to First & Second Floor Distribution Board 4
Core , LV, PVC/PVC, Al. cable :
36
50mm² thro PVC pipe 50 mm Dia. m 10
70mm² in suitable PVC Pipe Dia m 150
Supply , installation , testing and comissioning of Service
Cable from Pole Meter to Distribution Board of 4- Core ,
PVC/PVC, Al. cables:
4-core, 10mm² in rigid PVC pipe 50mm Dia,burried m 4,160
4-core, 25mm² thro PVC pipe 50 mm Dia,burried. m 2,040 3,240
37 4-core, 50mm² thro PVC pipe 50 mm Dia,burried. m 320
4-core, 70mm² thro PVC pipe 50 mm Dia,burried. m 50
1-core, 185mm² thro PVC pipe suitable Dia,burried. 240
4-core, 120mm² thro PVC pipe suitable Dia,burried. m 240
1-core, 300mm² thro PVC pipe suitable Dia,burried. m 240
Supply, wiring, testing and commissioning of PVC insulated,
PVC sheathed,Unarmoured Auminum conductor cable
600/1000V grade cables to be laid and pulled through relevent
rigid PVC conduit or duct including cost of connections at both
ends with necessary lugs, thimbles, brass nuts, bolts,
washers, designation labels engraved on 6 mm plastic strips
38 of suitable size to be tied on both ends with PVC adjustable
straps, complete in all respects for the following sizes.
Approximate length is given herewith while the actual length of
cable to be laid shall be practically measured at site by the
contractor
4-Core, 95 mm2 m 485
1-Core, 185 mm2 m 40
Bill-B (CONTRACT-01)

B-1: B-2: B-3: B-4: B-5: B-6: B-7: B-8:


RESIDEN RESIDEN RESIDENCE RESIDEN OFFICER JR.OFFIC REST WAPDA
CE CE CATEGORY-3 CE 'S ER'S HOUSE PROJEC
CATEGO CATEGO (39- CATEGO HOSTEL HOSTEL (01 NO) T
RY-1 (8- RY-2 (51- BLOCKS / RY-4 (26- CATEGO CATEGO OFFICE
Item BLOCKS BLOCKS 78-UNITS) BLOCKS RY 2 (4 RY-3 (01
No. ITEMS OF WORK UNIT / 8- / 51- / 104- NOS.) NO)
UNITS) UNITS) UNITS)

Fire Detection & Alarm System


Wiring of manual station wired with 1 core 1.5mm2 PVC
insulated wire 300/;500 V. Grade and including cost of 20mm
(3/4") dia heavy duty PVC conduit recessed in walls, columns,
slab, floor or above false ceiling with all necessary fixing
accessories as per site condition, 75mm (3") high PVC
39 Each 44 344
junction boxes, pull boxes, steel wire, 2.5mm sq. PVC
insulated wire of colour green, yellow (double strip), box 16
SWG with earth terminal and two coats of all necessary
material complete in all respects

Addressable Optical Heat Detector with Base &


Accessories as
• Removable, High performance chamber
• Twin fire LED’s allow 360 degree viewing
40 • Locking mechanism (sensor to base) Each 2 24
• Variable sensitivity
• Electrically addressed
• Approved by LPBC & Vds

Optical type smoke detectors addressable module as per


41 Each 42 320
specification with orignal glass.mounting
Supply, installation and commissioning of electronic hooter
42 Each 4 12
wall mounted
Supply, installation, testing and connection of Manual call
base complete, surface or flush mounting, different color
43 options, in suitable enclosure with arrangement, to raise the Each 6 24
alarm when the glass is manually broken

02 Loop Addressable Fire Alarm Control Panel operated on


230V AC/24V DC,15 AH Secondary power as
• Fully expandable system from 1-12 loops with distributed
intelligence for added security
• 125 device addresses per loop
• Up to 12 loop sounders with 32 individually programmable
addresses per loop
• 2 fire output changeover relays and 1 fault output relay(NC)
• Blank box option for sub panels
• Detector loops fully monitored for integrity
• 8 programmable zones
• 8 fully programmable sounder and I/O groups
• Event log 2000 entries FIFO
• Backlit LCD display 4 row * 40 characters
• Multiple programming options, onboard keypad, Remote
44 IR(optional),PS2 keyboard • Windows based software for Each 1 1
programming
• Windows based PC graphic software for alarm management
and reporting(optional)
• Multiple language support(menu selectable)
• MODBUS (ASCII & RTU) and BSM support
• Evacuate / Class change input (optional)(Each smoke
sensor will be detected)
Battery: 24V DC, with floats and boost type battery chargers
and Automatic Transfer Switch.

Installation including Wiring, fitting, PVC pipe & Labor charges


Per
45
Point
1 1
Programming, Testing & Commissioning of Entire Fire Alarm Per
system. Point
1 1

39
Bill-B (CONTRACT-01)

B-1: B-2: B-3: B-4: B-5: B-6: B-7: B-8:


RESIDEN RESIDEN RESIDENCE RESIDEN OFFICER JR.OFFIC REST WAPDA
CE CE CATEGORY-3 CE 'S ER'S HOUSE PROJEC
CATEGO CATEGO (39- CATEGO HOSTEL HOSTEL (01 NO) T
RY-1 (8- RY-2 (51- BLOCKS / RY-4 (26- CATEGO CATEGO OFFICE
Item BLOCKS BLOCKS 78-UNITS) BLOCKS RY 2 (4 RY-3 (01
No. ITEMS OF WORK UNIT / 8- / 51- / 104- NOS.) NO)
UNITS) UNITS) UNITS)

Elevator
Supply, Installation, testing and commissioning of Passenger
elevators with the provision of Guarantee One year and Parts
warranty and availability. Elevators should be advanced drive
and control technology with minimum energy consumption,
size and area according to the drawing # 251-689 & 690.
Elevator should be micro-processor control, with multiple fault
protections emergency device and full load protection. High-
quality fitting and fault protection. Operating control safety and
reliabilityshould be according to IEC standards and as
required. Each
Weight capacity: 1600 kg, 2 stops and 2 levels, drive control:
39 VVVF (Simplex), motion control: collective selective, door
control: VVVF, door opening: 2 pannel side opening, power
supply: 3 phase, 380V, light supply single phase 220V, shaft
size: (WxD): 2.45x3.05m, overhead 4500mm, pit depth:
1520mm, car walls, doors etc. Hairline st./steel, car ventilation,
indicating the running operation

Supply, Wiring, Installation, testing and commissioning of Data Each


/ Ethernet point complete in all respects. 365

Supply, Wiring,Installation, testing and commissioning of 24 Each


9
part 10/1000 data / networking switch
Total of 1.3
B-9: B-10: B-11: B-12: B-13: B-14:
WAPDA COMMU WAPDA TELEPH PRECAS PUBLIC
HOSPITA NITY SECURIT ONE T HEALTH
L (01 NO) CENTER Y EXCHAN TEMPOR WORKS
(IN
OFFICE GE (01 ARY HOUSE
(01 NO) NO) FENCE SEPTIC
WALL TANKS)
(LENGTH
,
L=960m)

1,018 824 470 149 120 964

679 550 313 99 120 642

816 637 442 68 30

3,201 2,502 1,208 460

359 201 101 39 1

50 40 27 4 120

484 368 178 99 483

1,276 473 519 25

223,530 92,260 60,468 12,340 40,000 67,656

278 85 139 186


650 198 323 433
200 166 141 58

117 99 49 15
13,303 4,912 4,740 1,467
1,682 547 205

124
10,337 631 2,086 752
2,423 1,336
1,442 174 84
1,237
260
129
38 14
1,020 268
131 179
992 1,282 1,105
1,215 167 235 181
371 13 99

358
26 122 269
56
142
67
111
2,337 49

93 46

147 20 46 27
26 29 8 2
2 2 1

721 87 42 51
225 42 16 16
241
28 8
B-9: B-10: B-11: B-12: B-13: B-14:
WAPDA COMMU WAPDA TELEPH PRECAS PUBLIC
HOSPITA NITY SECURIT ONE T HEALTH
L (01 NO) CENTER Y EXCHAN TEMPOR WORKS
(IN
OFFICE GE (01 ARY HOUSE
(01 NO) NO) FENCE SEPTIC
WALL TANKS)
(LENGTH
,
L=960m)

17 22 18

1 2 2
13

1,529 362 254 306

48 39 17 306

5 5 2 20
5 5 2
10

2,640 3,234 1,178

2,403
1,025
650
650
1,644

130
192
B-9: B-10: B-11: B-12: B-13: B-14:
WAPDA COMMU WAPDA TELEPH PRECAS PUBLIC
HOSPITA NITY SECURIT ONE T HEALTH
L (01 NO) CENTER Y EXCHAN TEMPOR WORKS
(IN
OFFICE GE (01 ARY HOUSE
(01 NO) NO) FENCE SEPTIC
WALL TANKS)
(LENGTH
,
L=960m)

225 34 7 9
250 66 135 63
64 75 50
77 52 8
13 10 12

48 48 12 3

50 20 20 5
35 8 8 3
25 4 4 2
30 12 8 5
127 37 28 9

12 2 4

2 1 2

48 13 12 3

37 11 8 3

2 2 2

30 15 5 3

130 75 81 23
161 92 100 30

30 7 4 1

7 4 2

7 11 6 2

60 9 19 3

15 5 6 2

37 13 6 3
37 13 6 3
37 13 6 3
32 13 12 3

42 11 12 3
162 30 71 5
128 21 40 7
18

15 5 6 2
16 9 9 3
16 9 9 3

101 33 27 13
B-9: B-10: B-11: B-12: B-13: B-14:
WAPDA COMMU WAPDA TELEPH PRECAS PUBLIC
HOSPITA NITY SECURIT ONE T HEALTH
L (01 NO) CENTER Y EXCHAN TEMPOR WORKS
(IN
OFFICE GE (01 ARY HOUSE
(01 NO) NO) FENCE SEPTIC
WALL TANKS)
(LENGTH
,
L=960m)

815 319 144 66

298 91 56 26

1,600 450 200

2,400 500 1,500

2,200 490

1,000 100 30

40 80 240

548 149 16 28
132 38 35 12

33 39 16 9

58 33 55 17

44 60 22

6
1 2
4 4 1

66 24 20 10

35 9 7 3

298 91 108 56

4 2 1

41 17 9 6

200 200 200 300

1 26 15

1 1 1 1

25 5 26 15

17 3 1 2

200 200 20 60

6 1 1

2
B-9: B-10: B-11: B-12: B-13: B-14:
WAPDA COMMU WAPDA TELEPH PRECAS PUBLIC
HOSPITA NITY SECURIT ONE T HEALTH
L (01 NO) CENTER Y EXCHAN TEMPOR WORKS
(IN
OFFICE GE (01 ARY HOUSE
(01 NO) NO) FENCE SEPTIC
WALL TANKS)
(LENGTH
,
L=960m)

2,800 600 1,300 450

9 3 1 1

9 3 1 1

100 35 10 10

20 4 2

6
140

50 40

50
240
B-9: B-10: B-11: B-12: B-13: B-14:
WAPDA COMMU WAPDA TELEPH PRECAS PUBLIC
HOSPITA NITY SECURIT ONE T HEALTH
L (01 NO) CENTER Y EXCHAN TEMPOR WORKS
(IN
OFFICE GE (01 ARY HOUSE
(01 NO) NO) FENCE SEPTIC
WALL TANKS)
(LENGTH
,
L=960m)

93

89

1
B-9: B-10: B-11: B-12: B-13: B-14:
WAPDA COMMU WAPDA TELEPH PRECAS PUBLIC
HOSPITA NITY SECURIT ONE T HEALTH
L (01 NO) CENTER Y EXCHAN TEMPOR WORKS
(IN
OFFICE GE (01 ARY HOUSE
(01 NO) NO) FENCE SEPTIC
WALL TANKS)
(LENGTH
,
L=960m)

12 26 15

1 1 1

You might also like