1. Switch on the machine, wait a few second.
autobasictech.blogspot.com Page 2
4. Select Calibration
7. Select R134a.
autobasictech.blogspot.com Page 3
8. During this display, the process of making preparation for the R134a calibration required.
9. Open the back cover of this machine. On both sides of the machine. There are 8 screws.
autobasictech.blogspot.com Page 4
11. Enter weight at Input Placed Weight = 4980g. wait a few minutes , Calibration Complete will
display.
12. Back to Sensor Select display, select Used Oil for calibration.
13. During this display, prepare the calibration bottle weights for Used Oil, Fresh Oil and UV Dye.
autobasictech.blogspot.com Page 5
14. Back to Calibration display. Select Pressure Calibration Sensor.
WARNING
ENSURE OIL FOR VACUUM PUMP ARE ENOUGH BEFORE START PROCESS
autobasictech.blogspot.com Page 6
15. Back to Select Service. Select ACS Maintenance
autobasictech.blogspot.com Page 7
18. These display shown:
2
3
autobasictech.blogspot.com Page 8