SIZING BLOWER NP3


Date: 9/5/2019

BLOWER SIZING (find heat release rate kJ/s )

from above figure 8.1-1, to maintain temperature at 90 degC, at 50% wt concentration


A enthalpy release is 60 kJ/kg

B total volume of storage tanks 40 m3


C 50% sulphuric acid SG 1.5
D mass of sulphuric acid 60000 kg (B*C*1000)
E heat release will be 3600000 kJ (A*E)

because we are doing 2 stage dilution, therefore heat release divide by half
F new heat per stage 1800000 kJ (E/2)
G duration set to finish 1st stage 8 hrs
H power need to remove 62.50 kJ/s (F/G)

BLOWER SIZING (find mass flowrate kg/s)

(use Q = m*Cp*deltaT)
Q= power remove kJ/s
m= mass flowrate kg/s
Cp= heat capacity of air at KJ/kg.K
deltaT= temperature different in kelvin

I heat capacity of ambient air 1.006 kJ/kg.K (at constant pressure and 0 degC)
J assume air initial temp. 305 K
K final air temp desired. 363 K
L different temperature 58 K (K-J)
M cp*delta T 58.3 kJ/kg ( I*L )
N air mass flowrate 1.07 kg/s (H/M)

Q given air density 15C, 1 atm 1.208 kg/m3


R air volume flowrate I 0.89 m3/s (N/Q)
S air volume flowrate II 53 m3/min (R*60)
T air volume flowrate III 2254 cfm (O*35.31*120%)

blower specifications website https://www.taiko-kk.com/pdf/R_E.pdf


, at 50% wt concentration

(B*C*1000)
onstant pressure and 0 degC)

5.31*120%)
3500mm Note: Air bubble fo

sulphuric acid 5
50% 0
0 2
0 3
m 0
m 0
c
f
m
0
0 2
0 3
m 0
m 0
c
f
air bubble m

5 3
0 1
0 0
m m
m m
Note: Air bubble for cooling purpose
blower
TAIKO MARKETING SDN. BHD

Physical properties

You might also like