Intensive Care and

Transport Ventilator Solutions

www.axcentmedical.com
LYRA x1
Technical Specifications

Physical Specification Controlled Parameters


Dimensions: 336 mm x 330 mm x 345 mm O2%: 21-100% (increments of 1%)
(L x W x H): 6
 64 mm x 600 mm x 1370 mm VT (Tidal Volume): Adult: 100-2000 mL
(with trolley) (increments of 10 mL) / Pediatric: 20-300 mL
Weight: A pproximately 9.5 kg, (increments of 1 mL)
Approximately 31.0 kg (with trolley) f (Ventilation frequency): 1-80 bpm
(increments of 1 bpm)
Screen fSIMV (Ventilation frequency in SIMV mode):
Display Size: 12.1 Color active matrix TFT touch 1-80 bpm (increments of 1 bpm)
Display Resolution (H) x (V): 1280 x 800 pixels I:E range: 4:1-1:10 (increments of 0.5)
Brightness: Adjustable Tinsp (Inspiratory time): 0.20-10 s
(increments of 0.05 s)
Ventilation Specifications Tslope (Time of Pressure Rising): 0-2.00 s
Patient Type: Adult, Pediatic (increments of 0.05 s)
Invasive Ventilation Mode: Thigh: 0.2-30 s (increments of 0.1 s)
VCV (Volume Control Ventilation) Tlow: 0.2-30 s (increments of 0.1 s)
PCV (Pressure Control Ventilation) Tpause: 5%-60% (increments of 1%), Offff
VSIMV (Volume Synchronized Intermittent ΔPinsp: 0-60 cm H2O (increments of 1 cm H2O)
LYRA x1 Most performing and Mandatory Ventilation) ΔPsupp: 0-60 cm H2O
versatile ventilation for hospital applications PSIMV (Pressure Synchronized Intermittent (increments of 1 cm H2O)
Mandatory Ventilation) Phigh: 0-60 cm H2O (increments of 1 cm H2O)
CPAP/PSV (Continuous Positive Airway Pres- Plow: 0-45 cm H2O (increments of 1 cm H2O)
A compact turbine driven ventilator with multi-function, covers the
sure/Pressure Support Ventilation) PEEP: 1-45 cm H2O
non-invasive and invasive ventilation, and is suitable for treatment
PRVC (Pressure Regulated Volume Control) (increments of 1 cm H2O), Offff
of most patient type. LYRA x1 is a versatile specialist throughout V + SIMV (PRVC + SIMV) Flow trigger: 0.5-15 L/min
hospital and transport. Comprehensive ventilating modes, including Apnea Ventilation (increments of 0.1 L/min)
APRV, PRVC, NIV are available for all your demands and for all type of patients Non-invasive Ventilation Mode: Pressure trigger: -10 to -0.5 cm H2O
from neonatal to adult. PCV (Pressure Control Ventilation) (increments of 0.5 cm H2O)
PSIMV (Pressure Synchronized Intermittent Exp% (Expiration termination level): 10-85%
A collapsible high resolution touch-screen display makes LYRA x1 mounted on
Mandatory Ventilation ) (increments of 5%), Auto
a trolley your choice for ICU applications, as well as a high performance ventila- CPAP/PSV (Continuous Positive Airway
tor throughout hospital and transport. Pressure/Pressure Support Ventilation)
BPAP (Bilevel Positive Airway Pressure)
The inovative expiration valve disassembling concept brings more ease and efficiency for the steriliza-
APRV (Airway Pressure Release Ventilation))
tion process.As your versatile assistant, LYRA x1 is configured with O2 therapy, P-V tool, a lung titrating
gold standard, etc. Advanced features, which can maximize your confidence in all critical moment.

www.axcentmedical.com
LYRA x1
Technical Specifications

Apnea Ventilation Real time Graphics: Monitoring Accuracy Airway pressure Frequency High: 10-85 cm H2O
Vtapnea: Adult: 100-2000 mL (increments of Pressure-time waveforms: Paw-Volume Loop Airway pressure (Ppeak, Pplat, Pmean, PEEP, Inspired oxygen (FiO2) High: Actual reading
10 mL) / Pediatric: 20-300 mL (increments of Flow-time waveforms: Flow-time Loop PAP, EPAP): ±(2 cm H2O + 4% of the actual + 8% (High-pressure oxygen), 2%-100%
1 mL) Volume-time waveforms: Paw-Flow Loop reading) (Low-pressure oxygen) / Low: Actual rea-
ΔPapnea: 5-60 cm H2O (increments of 1 cm H2O) Tidal Volume: (Tvi, Tve, TVe/IBW, TVe spn): ding - 8% (High-pressure oxygen), 18%-98%
Fapnea: 1-80 bpm (increments of 1 bpm) Control Accuracy 0 ml-100 ml: ±(10 ml + 3% of the actual (Low-pressure oxygen)
Apnea Tinsp: 0.20-10 s (increments of 0.05 s) O2%: ±(3 vol.% +1% of setting) reading) (BTPS) Apnea alarm time: 5-60 s
TV: ±(10 mL +10% of setting) (BTPS) 100 ml-4000 ml: ±(3 ml +10% of the actual
Sigh Tinsp: ±0.1 s or ±10% of setting, whichever is reading) (BTPS) Trend
Sigh Switch: On, Offff greater Minute Volume (MV, MVspn, Mvleak): Type: Tabular, Graphic
Interval: 20 s-180 min (increments of 1 s from 20 I: E 2:1 to 1:4: ±10% of setting, other range: ±0.3 L/min or ±8% of the actual reading, Length: 72 hours
to 59 s, increments of 1 min from 1 to 180 min) ±15% of setting whichever is greater (BTPS) Content: Monitor Parameters, Setting Parame-
Cycles Sigh: 1-20 (increments of 1 ) f: ±1 bpm Frequency (ftotal, fmand, fspn): ±5% of reading ters (Setting Ventilation mode and Parameters)
Δint.PEEP: 1-45 cm H2O fSIMV: ±1 bpm or ±1bpm, whichever is greater
(increments of 1 cm H2O), Offff Tslope: ±(0.2 s + 20% of setting) Inspired Oxygen (FiO2): ±(2.5 vol.% + 2.5% of
PEEP: ±(2.0 cm H2O + 5% of setting) the actual reading)
Synchronized Tube Resistance Compliance ΔPinsp: ±(2.0 cm H2O + 5% of setting) Resistance: 0 to 50: ±10 cm H2O/L/s
Tube Type: ET Tube, Trach Tube, Disable STRC ΔPsupp: ±(2.0 cm H2O + 5% of setting) Other range: 50% of the actual reading
Tube I.D.: Adult: 5.0 -12.0 mm (increments of Phigh: ±(2.0 cm H2O + 5% of setting) Compliance: 25% of the actual reading or
0.5 mm) / Pediatric: 2.5 - 8.0 mm (increments Plow: ±(2.0 cm H2O + 5% of setting) ±10 ml/cm H2O, whichever is greater
of 0.5 mm) Thigh: ±0.2 s or ±10% of setting, whichever is RSBI: 0 to 1000 1/(Lmin): 15% of the actual
Compensate: 0-100% (increments of 1%) greater reading or ±20 1/(Lmin)
Expiration Compliance Switch: On, Offff Tlow: ±0.2 s or ±10% of setting, whichever is WOB: -
greater NIF: ±(2 cm H2O + 4% of the actual reading)
Monitored parameters Pressure Trigger: ±(1.0 cm H2O + 10% of setting) P0.1: ±(2 cm H2O + 4% of the actual reading)
Numeric: Flow Trigger: ±(1.0 L/min + 10% of setting) PEEPi: -
Paw Vte Cdyn Δint.PEEP: ±(2.0 cm H2O + 5% of setting) Rcexp: -
Ppeak VTi Cstat Exp%: ±10%
Pplat Oxygen concentration Rcexp fapnea: ±1 bpm Alarm settings
Pmean VTe spn WOB ΔPapnea: ±(2.0 cm H2O + 5% of setting) Tidal Volume: High: Adult: 110-4000 mL, Off /ff
PEEP VTe/IBW RSBI Tvapnea: ±(10 mL + 10% of setting) (BTPS) Pediatric: 25-600 mL, Off / Low: Adult:
Insp Flow ftotal NIF Apnea Tinsp: ±0.1 s or ±10% of setting, 50-4000 ml, Off / Pediatric: 10-600 mL, Offff
Exp Flow fmand P0.1 whichever is greater Minute Volume: High: Adult: 0.2-100.0 L/min /
MV fspn PEEPi Pediatric: 0.2-60.0 L/min / Low: Adult:
MV leak Re Continuous Flow (O Therapy) 0.1-50.0 L/min / Pediatric: 0.1-30.0 L/min
MV spn Ri

www.axcentmedical.com
LYRA x1
Technical Specifications

O2 Therapy
Controlled Parameters Others
O2%: 21-100% (increments of 1%) Communication interface: Rs232, Ethernet,
Flow: 4-60 L/min USB port, Nurse call, CO2 calibration connector
Controlled Accuracy Gas supply: O2
O2%: ±(3 vol.% +1% of setting) Pipe Connector: NIST or DISS
Flow: ±(2 L/min +10% of setting) (BTPS) Gas supply pressure: 280-600 kPa
Trolley: Dimensions
Environmental specifications 1000 mm x 676 mm x 505 mm,
Temperature: 5-40 °C (operating); -20 to 60 °C Approximately 21 kg
(storage and transport, O2sensor: -20 to 50 °C )
Relative Humidity: 10-95% (operating);
10-95% (storage and transport)
Barometric Pressure: 62-106 kPa (operating);
50-106 kPa (storage and transport)

Power Battery Backup


External AC power supply
Input voltage: 100-240 V LYRA x2 Excellent performance of
Input frequency: 50/60 Hz Non-Invasive and Invasive Ventilation
Input current: 2.5 A Max
Fuse: T2.5 AH/250 V LYRA x2 is a premium non-invasive turbine driven ventilator with
Internal battery
no compromise on the performance in invasive ventilation.
Number of batteries: One or Two (Optional)
Battery type: Build-in Lithium-ion battery, User can easily switch between a NIV mode and IV modes by UI
11.25 VDC, 6400 mAh operation only.
Battery run time: 3 hours (Powered by one
Comprehensive parameter monitoring describe the full scenario
new fully-charged battery in standard working
condition), 6 hours (powered by two new of patient’s status to the care giver.
fully-charged batteries in standard working
With mass being in ICU, giving a mechanical ventilation takes
condition).
lots of attention. An up to 18.5 inch vertical layout touching dis-
play makes the operating of the ventilator smooth & easy.

www.axcentmedical.com
LYRA x2
Technical Specifications

Physical Specification Controlled Parameters Min P (VS minimum IPAP): 5-30 cm H2O Synchronized Tube Resistance Compliance
Dimensions: 327 mm x 310 mm x 493 mm O2%: 21-100% (increments of 1%) (increments of 1 cm H2O) Tube Type: ET Tube, Trach Tube, Disable STRC
(L x W x H): 664 mm x 600 mm x 1520 mm VT (Tidal Volume): Adult: 100-2000 mL Max P (VS maximum IPAP): 6-40 cm H2O Tube I.D.: Adult: 5.0-12.0 mm (increments of
(with trolley) (increments of 10 mL) / Pediatric: 20-300 mL (increments of 1 cm H2O) 0.5 mm) / Pediatric: 2.5-8.0 mm (increments
Weight: Approximately 12.0 kg, Approximately (increments of 1 mL) Max P (PPV maximum pressure limit): of 0.5 mm)
33.0 kg (with trolley) f (Ventilation frequency): 1-80 bpm 5-40 cm H2O (increments of 1 cm H2O) Compensate: 0-100% (increments of 1%)
(increments of 1 bpm) Max V (PPV maximum volume limit): Expiration Compliance Switch: On, Off
Screen fSIMV (Ventilation frequency in SIMV mode): 200-3500 mL (increments of 5 ml)
Display Size: 18.3 Color active matrix TFT touch 1-80 bpm (increments of 1 bpm) Max E: 0-100 cm H2O/L Monitored parameters
Display Resolution (H) x (V): 1080 x 1980 pixels I:E range: 4:1-1:10 (increments of 0.5) (increments of 1 cm H2O/L) Numeric:
Brightness: Adjustable Tinsp (Inspiratory time): 0.20-10 s (increments Max R: 0-50 cm H2O/L Paw Oxygen concentration WOB
of 0.05 s) (increments of 1 cm H2O/L) Ppeak VTe spn RSBI
Ventilation Specifications Tslope (Time of Pressure Rising): Thigh PPV%: 0%-100% (increments of 1%) Pplat VTe/IBW NIF
Patient Type: Adult, Pediatric 0-2.00 s (increments of 0.05 s) Pmean f P0.1
Invasive Ventilation Mode: Tlow: 0.2-30 s (increments of 0.1 s) Apnea Ventilation PEEP ftotal PEEPi
VCV (Volume Control Ventilation) Tpause: 0.2-30 s (increments of 0.1 s) Vtvapnea: Adult: 100-2000mL (increments of Insp Flow fmand PIP
PCV (Pressure Control Ventilation) ΔPinsp: 5%-60% (increments of 1%), Off 10 mL) / Pediatric: 20-300 mL (increments of Exp Flow fspn EPAP
VSIMV (Volume Synchronized Intermittent ΔPsupp: 0-60 cm H2O (increments of 1 cm 1 mL) MV Re Pt.Trig
Mandatory Ventilation) H2O) ΔPapnea: 5-60 cm H2O MV leak Ri Pt.leak
PSIMV (Pressure Synchronized Intermittent Phigh: 0-60 cm H2O (increments of 1 cm H2O) (increments of 1 cm H2O) MV spn Cdyn Tot.leak
Mandatory Ventilation) Plow: 0-45 cm H2O (increments of 1 cm H2O) Fapnea: 1-80 bpm (increments of 1 bpm) Vte Cstat Continuous Flow (O2 Therapy)
CPAP/PSV (Continuous Positive Airway PEEP: 1-45 cm H2O Apnea Tinsp: 0.20-10 s (increments of 0.05 s) VTi Rcexp
Pressure/Pressure Support Ventilation) (increments of 1 cm H2O), Off Real time Graphics:
PRVC (Pressure Regulated Volume Control) Flow trigger: 0.5-15 L/min Sigh Pressure-time waveforms: Paw-Volume Loop
V + SIMV (PRVC + SIMV) (increments of 0.1 L/min) Sigh Switch: On, Off Flow-time waveforms: Flow-time Loop
BPAP (Bilevel Positive Airway Pressure) Pressure trigger: -10 to -0.5 cm H2O Interval: 20 s-180 min (increments of 1 s Volume-time waveforms: Paw-Flow Loop
APRV (Airway Pressure Release Ventilation) (increments of 0.5 cm H2O) from 20 to 59 s, increments of 1 min from
Apnea Ventilation Exp% (Expiration termination level): 10-85% 1 to 180 min)
Non-invasive Ventilation Mode (increments of 5%), Auto Cycles Sigh: 1-20 (increments of 1)
CPAP (Continuous Positive Airway Pressure) CPAP: 4-25 cm H2O (increments of 1 cm H2O) Δint.PEEP: 1-45 cm H2O
PCV (Pressure Control Ventilator) EPAP: 4-25 cm H2O (increments of 1 cm H2O) (increments of 1 cm H2O), Off
PPS (Proportional Pressure Support) IPAP: 4-20 cm H2O (increments of 1 cm H2O)
S/T (Spontanous and Timed) Rise time: 1-5 (increments of 1)
VS (Volume Support, similarr like AVAPS ) Ramp time: 5-45 min (increments of 5 min), Off

www.axcentmedical.com
LYRA x2
Technical Specifications

Control Accuracy Max V (PPV maximum volume limit): ±15% of Alarm settings O2 Therapy
O2%: ±(3 vol.% + 1% of setting) setting Tidal Volume: High: Adult: 110-4000 mL, Off / Controlled Parameters
TV: ±(10 mL + 10% of setting) (BTPS) Max E: - Pediatric: 25-600 mL,Off O2%: 21-100% (increments of 1%)
Tinsp: ±0.1 s or ±10% of setting, Max R: - Low: Adult: 50-4000 ml, Off / Flow: 4-60 L/min
whichever is greater Fapnea: ±1 bpm Pediatric: 10-600 mL,Off Controlled Accuracy
I: E: 2:1 to 1:4: ±10% of setting, other range: ΔPapnea: ±(2.0 cm H2O + 5% of setting) Minute Volume: High: Adult: 0.2-100.0 L/min / O2%: ±(3 vol.% +1% of setting)
±15% of setting Tvapnea: ±(10 mL + 10% of setting) (BTPS) Pediatric: 0.2-60.0 L/min Flow: ±(2 L/min +10% of setting) (BTPS)
f: ±1 bpm Apnea Tinsp: ±0.1 s or ± 10% of setting, Low: Adult: 0.1-50.0 L/min /
fSIMV: ±1 bpm whichever is greater Pediatric: 0.1-30.0 L/min Environmental specifications
Tslope: ±(0.2 s + 20% of setting) Airway pressure: High: 10-85 cm H2O Temperature: 5-40°C (operating); -20 to 60 °C
PEEP: ±(2.0 cm H2O + 5% of setting) Monitoring Accuracy Frequency: High: 1-150 bpm, Off (storage and transport, O2 sensor: -20 to 50 °C)
ΔPinsp: ±(2.0 cm H2O + 5% of setting) Airway pressure (Ppeak, Pplat, Pmean, PEEP, Inspired oxygen (FiO2): High: Actual reading Relative Humidity: 10-95% (operating); 10-95%
ΔPsupp: ±(2.0 cm H2O + 5% of setting) PAP, EPAP): ±(2 cm H2O + 4% of the actual +8% (High-pressure oxygen) / 2%-100% (storage and transport)
Phigh: ±(2.0 cm H2O + 5% of setting) reading) (Low-pressure oxygen) Barometric Pressure: 62-106 kPa (operating);
Plow: ±(2.0 cm H2O + 5% of setting) Tidal Volume (Tvi, Tve, TVe/IBW,TVe spn): Apnea alarm time: Low: Actual reading -8% 50-106 kPa (storage and transport)
Thigh: ±0.2 s or ±10% of setting, 0 ml -100 ml: ± (10 ml+3% of the actual (High-pressure oxygen) / 18%-98% (Low-pres-
whichever is greater reading) (BTPS) / 100 ml - 4000 ml: sure oxygen) / 5-60 s
Tlow: ± 0.2 s or ±10% of setting, ±(3 ml + 10% of the actual reading) (BTPS)
whichever is greater Minute Volume (MV, MVspn, Mvleak): ±0.3 L/min Trend
Pressure Trigger: ±(1.0 cm H2O + 10% of or ±8% of the actual reading, whichever is Type: Tabular, Graphic
setting) greater (BTPS) Length: 72 hours
Flow Trigger: ±(1.0 L/min + 10% of setting) Frequency (ftotal, fmand, fspn): ±5% of reading Content: Monitor Parameters,
Δint.PEEP: ±(2.0 cm H2O + 5% of setting) or ±1 bpm, whichever is greater Setting Parameters (Setting Ventilation mode
Exp%: ±10% Inspired Oxygen (FiO2): ±(2.5 vol.% + 2.5% of and Parameters)
CPAP: ±(2.0 cm H2O + 5% of setting) the actual reading)
EPAP: ±(2.0 cm H2O + 5% of setting) Resistance: 0 to 50: ±10 cm H2O/L/s Other
IPAP: ±(2.0 cm H2O + 5% of setting) range: 50% of the actual reading
Rise time: - Compliance: 25% of the actual reading or
Ramp time: ±1 s ±10 ml/cm H2O, whichever is greater
Min P (VS minimum IPAP): ±(2.0 cm H2O + RSBI: 0 to 1000 1/(Lmin): 15% of the actual
5% of setting) reading or ± 20 1/(Lmin)
Max P (VS maximum IPAP): ±(2.0 cm H2O + WOB: -
5% of setting) NIF: ± (2 cm H2O + 4% of the actual reading)
Max P (PPV maximum pressure limit): P0.1: ± (2 cm H2O + 4% of the actual reading)
±(2.0 cm H2O + 5% of setting) PEEPi: -
Rcexp: -

www.axcentmedical.com
LYRA x2
Technical Specifications

Power Battery Backup Others


External AC power supply Communication interface: Rs232, Ethernet,
Input voltage: 100-240 V USB port, Nurse call, CO2 calibration connector
Input frequency: 50/60 Hz Gas supply: O2₂
Input current: 2.5 A Max Pipe Connector: NIST or DISS
Fuse: T2.5 AH/250 V Gas supply pressure: NIST or DISS
Internal battery Trolley
Number of batteries: One or Two (Optional) Dimensions: 1000 mm x 676 mm x 505 mm
Battery type: Build-in Lithium-ion battery, Weight: Approximately 21 kg
11.25 VDC, 6400 mAh
Battery run time: 3 hours (Powered by one
new fully-charged battery in standard working
condition) / 6 hours (Powered by two new
fully-charged battery in standard working
condition)

www.axcentmedical.com
MUSCA x1 MUSCA x2 Emergency & Transport Ventilator
Portable Ventilator
Features
Features • Compact design with weight 3.4 kg
• Portable and easy operation • 7”color touch screen with screen lock
• Innovative voice-guided direction • Airway pressure and EtCO2 real-time waveforms
• Tidal volume range: 100~1500 ml • Smart CPR mode according to AHA guideline
• Air Mix option for 60% O2 • I:E ratio range: 1:9 to 9:1; and tidal volume range: 50-2500 ml
• 3 knobs for flexible parameters adjustment • 9 ventilation modes: IPPV, V-AC, V-SIMV, P-AC, P-SIMV, CPAP, PCV, Manual, CPR
• TFT display of airway pressure and ventilation mode • Internal PEEP valve
• 3 ventilation modes. IPPV, Assisted control and Manual control • 40% or 100% for FiO2
• Li-ion rechargeable battery with more than 10 hours of working time • Rechargeable Li-ion battery with 5 hours working time
• Optional Mainstream EtCO2 with Respironics technology
• Audible and visual alarm for multi-parameters
• IPX4 Waterproof
• EN1789 certified
www.axcentmedical.com
Intensive Care and
Transport Ventilator Solutions
For more information, please contact us.

aXcent medical GmbH


Josef-Görres-Platz 2
56068 Koblenz
Germany
Phone: +49 261 30 11 117
Fax: +49 261 30 11 111
Mail: info@axcentmedical.com

www.axcentmedical.com