Anesthesia Machines
Physical Specifications
Dimensions and Weight
Height 1410 mm
Width 780 mm (not including breathing system) Trigger window 5% - 90% (increments of 5%)
945 mm (including breathing system) Flow trigger 0.5 ~ 15 L/min (increments of 0.5L/min)
Depth 690 mm Pressure trigger -20~ -1 cmH2O (increments of 1 cmH2O)
Weight <145 kg Expiration termination level 5% - 60% (increments of 5%)
(without vaporizers and cylinders) Min Rate 2 - 60 bpm (increments of 1 bpm)
Tslope 0.0 - 2.0 s (increments of 0.1 s)
Top Shelf Apnea I: E 4:1~1:8 (increments of 0.5)
Weight limit 30 kg ∆Papnea 3 - 30 cmH2O (increments of 1 cmH2O)
Width 630 mm
Depth 315 mm Positive End Expiratory Pressure (PEEP)
Type Integrated, electronic controlled
Work Surface Range OFF, 3~30 cmH2O
Height 850 mm (increments of 1 cm H2O)
Width 545 mm
Depth 310 mm Ventilator Performance
Driving pressure 280 kPa to 600 kPa
Drawer (Internal Dimension) Peak gas flow 120 L/min + Fresh Gas Flow
Height 130 mm
Width 415 mm Monitoring Parameters
Depth 325 mm Minute volume 0 ~ 100 L/min
Tidal volume 0~2500 ml
Bag Arm Inspired oxygen (FiO2) 18% ~ 100%
Height 1150 mm Peak airway pressure -20 ~ 120 cmH2O
Length 312 mm Mean pressure -20 ~ 120 cmH2O
Connection ISO 22mm OD, 15mm ID Plateau pressure -20 ~ 120 cmH2O
I:E 8:1 ~ 1:10
Casters Rate 0 ~120 bpm
Diameter 125 mm PEEP 0 ~ 70 cmH2O
Brakes All four casters with brakes Resistance (R) 0 ~ 600 cmH2O/(L/s)
Compliance (C) 0 ~ 300 ml/ cmH2O
Ventilator Specifications
Modes of Ventilation Control Accuracy
Manual/Spontaneous Ventilation/Bypass Volume delivery < 75 ml: ± 15 ml
Volume Control Ventilation (VCV) with PLV function ≥75 ml: ± 15 ml or ± 10% of the set value,
Pressure Control Ventilation (PCV) whichever is greater
Synchronized Intermittent Mandatory Ventilation Pressure delivery ± 3.0 cmH2O or ± 8% of the set value,
(SIMV-Volume Controlled and SIMV-Pressure Controlled) whichever is greater
Pressure Support Ventilation (PS) with apnea backup PEEP delivery OFF: ≤4.0 cmH2O
3 to 30 cmH2O: ± 2.0 cmH2O or ±8% of the set
Compensation value, whichever is greater
Circuit gas leakage compensation and automatic compliance
compensation Monitoring Accuracy
Volume monitoring < 75 ml: ± 15 ml
Ventilation Parameters Range ≥75 ml: ± 15 ml or ± 10% of the reading,
Patient Size Adult, Pediatric, Infant whichever is greater
Tidal volume 20~1500 mL ( (Volume Mode) Pressure monitoring ± 2.0 cmH2O
(increments of 1 mL) PEEP monitoring ± 2.0 cmH2O or ± 10% of the reading,
5~1500 mL (Pressure Mode) whichever is greater
Pinsp 5~60 cmH2O (increments of 1 cmH2O) MV monitoring ±15% of the reading
Plimit 10~100 cmH2O (increments of 1 cmH2O)
∆Psupp 3~60 cmH2O (increments of 1 cmH2O) Trend Graph
Rate 4~100 bpm (increments of 1 bpm) Continuous trend information with time discrete events for the latest
I:E 4:1 - 1:8 (increments of 0.5) 48 hours
Inspiratory pause (Tip:Ti) OFF, 5% - 60% (increments of 1%)
Inspiratory time (Tinsp) 0.2 - 5.0 s (increments of 0.1 s)
Trend Table Sevoflurane, Desflurane, MAC, Paramagnetic
Continuous trend information together with time discrete events for O2 (optional)
the latest 48 hours Warm-up time 45 s (ISO accuracy mode)
10min (full accuracy mode)
Alarm Log Book Sample rate Adu/Ped: 150, 180, 200 ml/min
500 events storage, first in first out Neo: 100, 110, 120 ml/min
Accuracy ± 10 mL/min or ± 10% of the set value,
Alarm Setting whichever is greater
Tidal volume Low: 0 ~ 1595 ml Range CΟ2: 0% ~ 10%
High: 5 ~ 1600 ml Des: 0% ~ 18 %
Minute volume Low: 0 ~ 99 L/min Sev: 0% ~ 8%
High: 0.2 ~ 100 L/min Enf, Iso, Hal: 0% ~ 5%
Inspired oxygen Low: 18% ~ 98% O2/N2O: 0% ~ 100%
High: OFF, 20% ~ 100% AwRR range 2 ~100 bpm
Apnea alarm VTe < 10ml measured in 20s AwRR accuracy 2 bpm ~ 60 bpm:± 1 bpm
Paw < (PEEP + 3) cmH2O in 20s 61 bpm ~ 100 bpm:± 2 bpm
Airway pressure low 0 ~98 cmH2O
Airway pressure high 2 ~100 cmH2O Carbon Dioxide (CO2) Modules
Sustained airway pressure alarm: 15s Method Infrared absorption
Subatmospheric pressure alarm: Paw < -10 cmH2O Module type Mindray side-stream
Alarm silence countdown timer: 120 to 0 seconds Capnostat mainstream
Oridion micro-stream
Ventilator Components (optional)
Flow Sensor Work mode Standby or measurement
Type Variable orifice flow sensor Displayed numerics EtCO2 , FiCO2
Location Inspiratory and expiratory port Waveform Capnography
Bag-to-Ventilator Switch
Type Bi-stable
Control Switch between manual and mechanical
ventilation
25 ~ 50 L/min (Low-flow)
Pressure relief device: Pressure compensation opening to the air
State indication of the disposal system: The float falls below the "MIN"
mark on the sight glass when the disposal system does not work or the
pump rate is lower than 25 L/min (Low-flow) or 75 L/min (high-flow).
Filter Stainless screen with hole diameter of
140 ~ 150 μm
Connector of the disposal system: ISO 9170-2
Materials
All materials in contact with exhaled patient gases are autoclavable,
except flow sensors (being not capable of being autoclaved), O2 sensor,
and mechanical pressure Gauge.
All materials in contact with patient gas are latex free.
Suction Device
Venturi Suction Regulator
Gas source Air, from system gas source
Minimum flow 20 L/min
Maximum vacuum ≥72 kPa at supply gas pressure of 280 kPa;
≥73 kPa at supply gas pressure of 600 kPa
| Healthcare with reach are registered trademarks or trademarks owned by Shenzhen Mindray Bio-medical Electronics Co., LTD
Mindray Building, Keji 12th Road South, © 2017 Shenzhen Mindray Bio-medical Electronics Co., Ltd. All rights reserved. Specifications subject to changes without prior notice.
High-tech Industrial Park, Nanshan, Shenzhen 518057, P.R. China P/N: ENG-WATO EX-35 datasheet-210285X4P-20180828
Tel: +86 755 8188 8998 Fax: +86 755 26582680
E-mail: intl-market@mindray.com www.mindray.com