You are on page 1of 1

H G F E D C B A

NOTES
33.790 GENERAL
1. All measurements are shown in millimeters. Drawings not to be scaled.
Only figured dimensions to be used.
A B C D E F G H 2. The contractor must check and verify all dimensions on site before
decra roofing tiles commencement of work. Any discrepancies must be notified immediately
to the architect.
to manufacturer's specifications
02 +5,100 roof pitch=300 to S.E's specifications 3. All sections are to be read as per floor plan and all drawings must be
read in concert with each other. Any discrepancies must be notified
immediately to the architect and clarified consulting the architectural or
15000
10
9
11 consultants drawing.
12
8
200x 300mm deep RC beam

300

300

300
200 2,400 200 3,800 200 1,300 200 4,100 200 7 1,400 200 to S.E details CONSTRUCTION

X1
13

650 550
6 +2,700 4. Damp proof course must be provided under all external walls at grade.

300

300
14

200 1,200 200 3,800 200 1,300 200 4,100 15 1,600


5
200 DPC to be minimum of 150mm above ground level.

2,400
counter

200 1,950

350 1,950
4

2 x 150 = 300
5. All slab at grade to be poured at 1000mm Gauge polythene on 50mm

2
16
2 x 150 = 300 1
3 top stone blinding on hardcore.
7 7

1
2 x 150 = 300

2 x 150 = 300
2
Powder coated aluminium
17
2,148 200 1,101 200

200

Dining
1 2

windows to detail. 6. All soil under slab and around external foundations to be poisoned for
18
2

500
1,925
1
termite control.
2,025

2,025
non-slip 0.00 Kitchen 150mm thick RC
Lounge 7. Window sills must be finished before internal plastering.

100
1,775

200

100
Ceramic Tiles

100
to S.E details
6 LOUNGE 6 CIVIL

300
200

200

200
8. All soils on cut embankment to be stabilized. The slope is not to exceed

1,465
200x 600mm RC
strip foundation to S.E details the natural angle repose of the soil
1,200 675 1,200

200 2,400 200 3,800 200 1,300 200 4,100 200 1,400 200 100 800 100 4,200 100 1,400 100 3,900 100 2,500 100 700 100
12.800

Bedroom 600 100 STRUCTURAL

3,300

3,300
non-slip Master Ceramic Tiles non-slip

900
14,800
4,400

4,400
Ceramic Tiles Bedroom 9. All RC work to structural engineer's details.

4,200
Ceramic Tiles Ceramic Tiles
+0mm +0mm
1,851 200

10. Depth of foundation to be determined on site to S.E's approval.

200

200 700 200


+0mm H G F E D C B A

1,835
650 200 650

200 200 11. All walls less than 200 mm thick to be reinforced with hoop iron at
200
0.200
2,800 200
4.890
2,100 200 1,100 1,300 1,100 200 2,800 200
0.200 2.600 0.200
1,400 200 SECTION X-X 1:100 every alternate course.

1,400
5 5
2,200 200

200

200
1

2
14250

14250
MECHANICAL
01

200 1,600 200 4,600 200 1,300 200 4,100 200


2,400

2,025 200 780 1,200 1,120 700 850

1,500
+0mm 12. All plumbing and drainage to comply with city councils specifications..

2,800
Utility +0mm

03
2 x 150 = 300

2,600

2,600

2,600
Cinema +0mm 13. All service ducts to be accessible from all floors

400 200 600


+0mm 14. Deep seal or anti-vac to all fittings connected to the SVP or waste pipes.
200

4 4 All bends and junctions to have inspection plates


200

2 x 150 = 300
+150mm 15. SVP (soil vent pipes) to be provided at the head of the drainage.
200

200

200
X X
Kitchen

1,200
-300mm 16. Drain pipes passing beneath buildings and driveways to be encased in
3,300

2 x 150 = 300

Ceramic Tiles Dining Area 2 x 150 = 300


150 mm concrete surround.
3,100

200 7,200 200


Ceramic Tiles 1,300 200 5,000 200
3,600

17. All under ground foul and waste drainpipes shall be UPVC to

300
3,600

3,600

MANICURED
comply to BSS 4514 & 5255.
2

+0mm Lounge

4,900
1,200

LAWN
Ceramic Tiles 18. The storm water drain to comply to BSS 556.
3 3
19. All inspection chamber covers and frames shall be cast iron to
2,025 200
1,225 900

675 200

500
comply to BSS 497 table 6 grade C.
Front Porch
0.200

2 2 20. Minimum slopes in drainpipes shall be 1%.


200

200

200
+0mmLOUNGE
8,925 200
21. No chases will be allowed in the slabs for pipes. Sleeves will be allowed
with the written approval of the S.E.
10

1 1
2 x 150 = 300

2 9

1,125

1,125
450

11
8 1,700 15,722 5,082
1
22. All testing of pipes must be completed before plastering.
12
7
BEDROOM 260 200 200 495 630 200 500 13 22,503

200 1,395 1,500 905 1,200 740 1,200 1,300 1,500 875 1,500 6
200 14 .
23. All mechanical work must be coordinated with electrical work. Any
5
500 4
15
MANICURED
conflicts must be clarified before work begins.
200 7,200 200 1,300 200 5,000 200 200 LAWN LAWN
16
X1

3
5.550

17

15000
18 2
ELECTRICAL
1 Existing sewer line

KITCHEN/ WORKERS

LIBRARY
04 24. All conduits must be laid before plastering

QUARTERS
25. All electrical work must be coordinated with mechanical
35.400

1.401

A B C D E F G H EXISTING WALKWAY
11.700

0.150

FLOOR PLAN LAYOUT REVISIONS & CONSIDERATIONS


KITCHEN 1:100 NO
. DATE DESCRIPTION BY
5.600

A B CBEDROOM D E F G H
SITE LAYOUT PLAN 1:250

800 2,600 4,000 1,500 4,300 900 700

14600 H G F E D C B A 7 6 5 4 3 2 1
0.200
600

600

7 7
0.200

0.200
2,025

275 600 605 LOUNGE


595
1,250

1,251

600 5125 600 900 600 2,500 600 1,600 10


+6.630
decra roofing tiles
to manufacturer's specifications +6.630 ARCHITECT
9
roof pitch=300 to S.E's specifications
609

6 6
11
12 8
600

7
+5.100 +5.100
13
14 6
2,903

4.300
15 5
BEDROOM
*All Drawings are exclusively copyrighted
16 4
5.286
4,400

3,800

17 3

18 2
by the architect
Concrete moulding to detail
587

+2.700 Steel casement window +2.700


KITCHEN
600

to schedule
300

200mm thick masonary wall


CONSULTANTS
5 5

0.200
10.900

14,575
14575

keyed to architect's approval


2,200 600
2,400

1,800

0.150

FRONT ELEVATION RIGHT ELEVATION


ELEVATION 01 ELEVATION 02
600

4 KITCHEN 4
2.164

1:100 1:100
600 3,207 593
2,700
3,300

7 6 5 4 3 2 1 H G F E D C B A
0.200

BEDROOM
600

BEDROOM

3 3
PROJECT
1,225 900

2.700

decra roofing tiles


1,425

+6.630 +6.630
2 LOUNGE 2 to manufacturer's specifications
525

roof pitch=300 to S.E's specifications LOUNGE


PROPOSED RESIDENTIAL DEVELOPMENT FOR
1 1 +5.100 +5.100
600 3,810 600 3,090 600 4,600 600
0.200
600

600

DR. STEVE OUMA AKOTH

13,900 Wall plastered and painted


to architect's approval PLOT NO.... UGENYA
0.200 3.450 0.200 4.450 0.200
Steel casement door

E-04
+2.700 +2.700
42.778 to schedule
200mm thick masonary wall 4190
A B C D E F G H keyed to architect's approval
E-01 E-01
DRAWING TITLE
Job No
.
E-02

FOUNDATION PLAN LAYOUT ELEVATION 03 ELEVATION 04 Presentation Drawings


1:100 PENTHOUSES 1:100
1:75 1:100 SCALE DRAWN CHECKED DATE
Dwg No.

GITAU JAMES DEC, 2017


GSPublisherVersion 0.0.100.100

You might also like