Professional Documents
Culture Documents
MeCA406i
MeTroy620
With the spirit of respect for life and the philosophies
MeCA812i BoCA X1
of human health, future creation, and quality-first
MEDIGATE Inc. has focused on development and
distribution of high-quality medical equipment.
Electrocardiograph Electrocardiograph
MeCA303i MeCA406i
12 Lead Resting ECG Analysis System. 12 Lead Resting ECG Analysis System.
12 Lead Interpretative ECG. 12 Lead Interpretative ECG.
3Ch ECG Recording. 3/6Ch ECG Recording.
3 Inch Roll & Z-fold Type ECG Recording Paper. 4 Inch Roll & Z-fold Type ECG Recording Paper.
4.3” Color TFT LCD (480 × 272) 4.3” Color TFT LCD (480 × 272)
Multi-language. Multi-language.
Internal and External (SD card) ECG Memory. Internal and External (SD card) ECG Memory.
Lead-Fail, Pacemaker Pulse Detection. Lead-Fail, Pacemaker Pulse Detection.
Rechargeable Battery. Rechargeable Battery.
ECG Management PC Software (Mecalyzer). ECG Management PC Software (Mecalyzer).
2 3
Electrocardiograph
Writer
Thermal dot array
Type
(Voltage axis : 8dots/mm, Time axis : 16dots/mm)
Number of Traces 3, 6 or 12 user-selectable 3 or 6 user-selectable
Sensitivity / Gain 5, 10, 20mm/mV
Speeds 5, 10, 25, 50mm/sec
Amplitude Accuracy ±5%
Speed Accuracy ±5%
Z-fold 282mm × 215mm 110mm × 100mm 80mm × 80mm
(W × L × sheets) × 200 sheets × 300 sheets × 300 sheets
Paper
Roll
× 110mm × 30m 80mm × 30m
(Length)
Electrical
Power Supply AC or Battery operation
AC Input 100-240VAC 50/60Hz, 110VA 100-240VAC, 50/60Hz, 60VA 100-240VAC, 50/60Hz, 70VA
14.4V Rechargeable 9.6V Rechargeable
Battery Type
Ni-MH, 3,800mAh Ni-MH, 3,800mAh
Printing @Automode 200 records 100 records
Battery Capacity
Standby Time 5 hours 5 hours
Physical
Dimension (W × L × H) 385mm × 367mm × 101mm 311mm × 242mm × 85mm
Weight 4.5kg 2.4kg
Safety
Classification Class I, Internally powered
Type of protection Type CF with defibrillation protection
Patient Leakage Current < 10㎂
4 5
ECG Simulator
MeCA-SIM12 • Operating
* Choose the signal using 4 digit number key.
ECG Simulator * Then press enter key to the output signal.
12 Lead Electrocardiogram. Pace Pulse Signal.
• Operating Example
4 Digit FND Display. Battery (9V) and DC Adapter (9~12V) Operate.
* If you want NSR 60BPM, Gain 1mVp-p, 60Hz Artifact signal.
State Beep Sound. Low Battery Detecting (LED, Beep Indicate).
→ You should choose the number "0212" then press Enter key.
8 Number Control Key and Enter Key. Auto Power Down (no input while 30min).
Normal Sinus Rhythms and Artifact. Dimensions (W × D × H) : 1180mm × 2160mm × 620mm • FND Message when Wrong Number (Command) Input Error
Basic Signal (Sinusoidal, Triangular, Square Wave). * noSI : Do not have Signal.
Sinusoidal Wave
Frequency 0.67, 1, 10, 25, 35, 40, 50, 60, 70, 90, 100, 110, 120, 130, 150, 180, 500 Hz
Amplitude 0.25, 0.5, 1, 1.5, 2, 3, 4, 5, 10 mVp-p
Pace Pulse
Pacer Spike Duration 0.1, 0.5, 1, 1.5, 2 ms
Pacer Spike Amplitude 0.5, 1, 2, 4 mV
6 7
Mobile Cart Body Composition Analyzer
MeTroy620 BoCA X1
Mobile Cart & Cable Arm Multi Frequency Body Composition Analyzer
Net Weight - 9kg Multi Frequency Analysis(2~1,0000kHz).
Gross Weight - 11kg Segmental Body Composition & Abdominal Fat Analysis.
MeTroy Body - Steel Tetrapolar 8-Points Tactile Electrode Method.
MeTroy Arm - ABS Plastic Trend Review.
Exercise & Dietary Prescription.
85cm
A Cable Arm
58cm D Wheel
Bocalyzer : Software
Operating System Windows 2000/XP/Vista/7
CPU Intel Pentium Ⅲ or Ⅳ, IBM-PC or compatible
Hard Disk 200MB of available hard-disk space
Memory(RAM) 512MB
Graphic Card & Monitor 16bit, 1024*768 resolution
Port Serial port or USB
Intracellular Ware, Extracellular Water, Edema, Mineral, Protein,
Muscle, Fat, Fat Free Mass, Segmental Muscle Mass, Segmental
Analysis Item
Fat Mass, Visceral Fat, Subcutaneous Fat Area, Target Weight,
Weight Control, Fat Control, Muscle Control, Body Balance.
Body Composition Analysis, Segmental Analysis, Trend &
Report Exercise Prescription, Exercise Menu, Exercise Prescription,
Dietary Prescription, Food Table Page.
8 9
Body Composition Analysis Report
◆ Reference
BMI (body mass index),
WHI (Waist/ Height ratio),
◆ Final Result WHR (Waist/ Hip ratio),
Muscle, fat and weight to lose are BMR (Basic metaboism),
analyzed and presented. daily required calories and
ECF (external cellular fluid)
rate are presented.
10 11
HQ / Factory / R&D Center
42-10, Taejanggongdan-gil, Wonju-si, Gangwon-do, Korea.
Tel. +82 - 33 - 747 - 3552 Fax +82 - 33 - 747 - 3691
Homepage: www.medigate.biz E-mail: medigate@medigate.biz