You are on page 1of 1

OPERATING INSTRUCTIONS SAFETY SUMMARY 3. Slide the equipment using appropriate tools and 2.

SUMMARY 3. Slide the equipment using appropriate tools and 2. For bigger loads, use interposing relay/contactor
All safety related codification, symbols and holding the unit from the front side, slide it over the 230VAC
800XA instructions that appear in this operating instruction fixed rail. L N
manual must be strictly observed to ensure operator as
well as equipment safety. The instruction manual is
WIRING GUIDELINES
A1 25
meant for personnel involved in wiring, installation, CAUTION: (L)

operation and routine maintenance of the 1. The power should be turned off while wiring and 15
(COM1) 26

equipment. maintenance to prevent the risk of electric shock. Do


LOAD 1
If the equipment related above safety measures are not touch the terminals when power is ON. A2
not practiced, the manufacturer does not have any 2. Wiring shall be done strictly according to the CONTACTOR
NO
COM
liability for human or equipment safety. terminal layout with shortest connections. Confirm A1

! CAUTION: Read complete instructions prior to 16 28


installation and operation of the unit. that all the connections are correct. (NC1)
C R 18 A2
CAUTION: Risk of electric shock. 3.Use lugged terminals to meet M3 screws and Snubber (NO1) (N)

SPECIFICATIONS ensure that the screws are tightened .


MAINTENANCE
SUPPLY 20V to 240V AC (AC : 50 or 60 Hz) 1. The power supply should be switched off before TERMINAL CONNECTIONS
VOLTAGE .12V to 240 VDC removing the equipment for cleaning. Ensure that no 1) Snubber Part No.: APRC - 01.
parts are charged. A1 25 2) MOV Part No.: AP-MOV - 03.
DELAY MODES On delay / Interval 2. Clean the equipment with a clean, soft cloth Note: Use snubber as shown above to increase the life
15 26 of internal relay.
soaked in water. Do not use any other cleaning
TIME RANGES 3 /10/30/60 sec./ Min agent other than the one specified by COM DIP SWITCH SETTINGS FOR SELECTION OF
S NC DELAY MODES
OUTPUT 2C/O (5A@250V AC/24V DC) manufacturer. U
Resistive NO NC
CONTACT INSTALLATION GUIDELINES P NO
COM DIR 4 MODE
P
ACCURACY Setting : ± 5% of full scale. ! CAUTION: L ON DELAY

Repeat : ± 0.5% or 50 msec . 1. The equipment is built-in type with Class II Y


16 28 INTERVAL
whichever is greater. construction and is protected by reinforced
LED INDICATION 1) Power ‘ON’. 18 A2
insulation. Terminals are a part of the front panel ON DELAY INTERVAL
2) Relay ‘ON’. and are protected by means of finger guard. Finger
POWER
t t
RELAY
RESET On interruption of power. guards are not to be removed during wiring, TERMINAL DESCRIPTION t = Set time
Reset time : Less than 100 ms. installation, operation or maintenance. A1 L TIMER SUPPLY
2. Conductors must not come in contact with the A2 TIMER SUPPLY DIP SWITCH SETTINGS FOR SELECTION OF
RELAY RATING 5 A @ 250 V AC / 24 VDC, N
TIME RANGE
resistive. internal circuitry of the equipment as it may lead to 15 COM
RELAY SWITCH SETTINGS
a safety hazard. 16 NC
MOUNTING 1) DIN rail mounting. CONTACT
3. Circuit breaker or main switch should be installed 18 NO 1 2 3 RANGE 1 2 3 RANGE
2) Screw mounting. 3 SEC 3 MIN
between power source and supply terminals to
SIZE (in mm) 22.5(W) x 75(H) X 101(D).
facilitate power ON/OFF function. This installation 10 MIN
TYPICAL LOAD CONNECTIONS 10 SEC

TEMPERATURE Operating: 0 to 500C, must be in a convenient position normally 30 SEC 30 MIN


Storage: 0 to 500C. 1. For load current less than 0.5A
accessible to the operator.
60 SEC 60 MIN
HUMIDITY Upto 95% RH. 230VAC
! CAUTION:
HOUSING ABS plastic 1. The equipment should not be installed in the L N (Specifications subject to change as development is a
WEIGHT 129 grams. environmental conditions other than those continuous process)
mentioned in this manual. A1 25 Selec Controls Pvt. Ltd.
2. Fuse Protection: The equipment does not have a (L) (Formerly Selectron Process Controls Pvt. Ltd.)
PANEL DIMENSIONS 15 26 Tel:91-22-28476443, Fax:91-22-28471733,
m 11.5mm
built-in fuse. A fuse of rating 275 VAC/1Amp is (COM1)
22.5m m
80
m
recommended. Website: www.selec.com
101mm 4.
Snubber E- mail: sales@selec.com.
EMC Installation Guidelines: L Document name: Operating/0711/800XA/ Version 1 OP217-V01
C O
1. Use proper input power cables with shortest A
R
8 9
connections and twisted type. D
10

10
61.0mm

7
6 75 35 75 R
5
4
mm mm mm
2. Layout of connecting cables shall be away from any 1 16 28
3 0 (NC1)
0

2 1
ON

internal emf source. 18 A2


(NO1) (N)
Mechanical Installation Guidelines:
1. The equipment uses a clamp for T type DIN rail only.
85mm Mounting holes 2. Ensure that the rail clamp is correctly fitted.