You are on page 1of 1

Vijaytech Consultants Pvt. Ltd.

H-17,GAUTAM MARG, SHYAM NAGAR, JAIPUR-19 INDIA


Phone : 91-141 2294432, 3257592 , Fax : 91-141-4023198
E-mail : vijaytech.jpr@gmail.com

PROJECT DETAILS:

UNNATI GROUP HOUSING

AT SIRSI ROAD
ARCHITECT:

A N K I T S H A R MA
B-4, C-49, VIDHYA APARTMENT, BAPU NAGAR, JAIPUR
Phone- 0141-4069251, Mobile: (+91) 9928407365,
arch_ankits@yahoo.com

300

#8@100C/C
GENERAL NOTES:-

1080
#8@200C/C 1. ALL DIMENSION ARE IN FEET, INCHES.
#8@150C/C

#8@200C/C
2. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH

1380
#8@75C/C

#8@150C/C RELEVANT ARCHITECTURAL AND SERVICE DRAWING ANY


ALTERNATE DISCREPANCY SHOULD BE IMMEDIATELY BROUGHT TO NOTICE.

#8@100C/C
3. DEWATERING SHALL BE DONE UP TO 1.50 M BELOW THE
850 FOUNDING LEVEL.
#8@75C/C

#8@75C/C

300

262
4. ALL LOOSE BOULDERS SHOULD BE FULLY REMOVED, BEFORE
#8@200C/C PLACEMENT OF PCC BED.

300 R-5(AS/ SHAP) FOR 46#BAR 5. ALL FOUNDATION PITS SHOULD BE BACK-FILLED WITH

R-6(AS/ SHAP) FOR 32#BAR 1150 WELL-COMPACTED GRAVEL / MORUM.

6. GRADE OF CONCRETE

a.) RAFT FOOTING - M-25

b.) RETAINING WALL M-25

7. GRADE OF STEEL SHALL BE Fe-500.

8. .WATER PROOFING OF RAFT, FOOTING, STITCHING SLAB &


RETAINING WALLS SHALL BE DONE BY MIXING INTEGRAL
WATER PROOFING ADMIX XYPEX ADMIX CA-2000 NF " XYPEX
CONCRETE WATER PROFING BY CRYSTALIZATION" TO
CONCRETE AS PER SPECIFICATION. ALONG WITH KUNISEAL
WATER STOP BAR (AN ACTIVE BENTONITE BASED WATER STOP)
USED IN HORIZONTAL & VERTICAL CONSTRUCTION JOINTS AS
PER SPECIFICATION UNLESS OTHERWISE NOTED.

300 1150
SIZE AS/ SHAP SIZE AS/ SHAP SIZE AS/ SHAP SIZE AS/ SHAP 16#12
GROUND FLOOR

300
FIRST FLOOR

7#20
8#12

300

262
M-30 M-30 M-30 M-30

300
1080

MIX. MIX. 5#20 MIX. MIX.


1380
TO

850

1380
850

8#12
24#12 12#20 12#20 24#12

1080
REINF. REINF. REINF. REINF.
300

262

+22#10 300
+20#12 +20#12 +22#10 REINFORCEMENT DETAILS

5#20

300
16#12 7#20 CHARACTERISTIC STRENGTH 500 N/SQ.MM CONFORMING TO IS

RINGS R-5 1150 RINGS R-6 RINGS R-6 RINGS R-5 300
1786-1985, SHALL BE USED.

2. LAP SHALL BE STAGGERED SO THAT NO MORE THAN 1/3 OF

BARS SHALL BE LAPPED AT ANY SECTION

3. LAP LENGTH FOR HIGH YIELD STRENGTH DEFORMED BARS

300 1150 SHALL BE:-

SIZE AS/ SHAP SIZE AS/ SHAP SIZE AS/ SHAP SIZE AS/ SHAP
GROUND FLOOR

16#12
300

CONC.GRADE Ldt

7#20
8#12

300 M-20
M-25

262
M-30 M-30 M-30 M-30
FOOTING

1080

300
MIX. MIX. 5#20 MIX. MIX. M-30
1380

CONCRETE DETAILS
1. GRADE OF CONCRETE SHALL BE M-25 CONFORMING TO IS
850
TO

456-2000 UNLESS OTHERWISE NOTED.

1380
2. CLEAR COVER OF CONCRETE TO THE MAIN REINFORCEMENT
850

8#12
24#12 12#20 12#20 24#12 UNLESS SPECIFIED,OTHERWISE SHALL BE :-

1080
REINF. REINF. REINF. REINF.
300

262

PARTICULARS BOTTOM TOP SIDES

+22#10 300
+20#12 +20#12 +22#10 FOOTING
COLUMNS

WALLS,FLOOR
2"(50MM.) 2"(50MM.) 2"(50MM.)
1 1/2"(40MM.)
1"(25MM.)
ON WATER FACE

5#20

300
SLAB & ROOF
SLAB OF 1 1/2"(40MM.)

16#12 7#20 WATER TANK. (ON EARTH SIDE)


WHERE APPLICABLE

RINGS R-5 1150 RINGS R-6 RINGS R-6 RINGS R-5 300
REVISION:

COLUMN CC-4 CC-12 CC-22 CC-33 DRAWN BY: LUCKY

CHECKED BY: RONAK GODHA

COPYRIGHT:
VIJAYTECH CONSULTANTS PVT. LTD.
SHEET TITLE:

COLUMN SCHEDULE
{BLOCK-B,PART-III}

DATE - 13/12/2019
DRG. NO. - S-01
SHEET - 01 OF 01
REVISION - 00
STAMP:

You might also like