Bearing capacity from SPT numbers


One of most commonly method for determining allowable soil bearing capacity is from standard penetration test (SPT) numbers. It
is simply because SPT numbers are readily available from soil boring. The equations that are commonly used were proposed by
Meryerhof based on one inches of foundation settlement. Bowles revised Meyerhof’s equations because he believed that Meryerhof’s
equation might be conservative.

Meryerhof’s equations:

For footing width, 4 feet or less:


Qa = (N/4) / K [1.12]
For footing width, greater than 4 ft:
Qa = (N/6)[(B+1)/B]2 / K [1.13]

Bowles’ equations:

For footing width, 4 feet or less:


Qa = (N/2.5) / K [1.14]
For footing width, greater than 4 ft:
Qa = (N/4)[(B+1)/B]2 / K [1.15]
2
Qa: Allowable soil bearing capacity, in kips/ft .
N: SPT numbers below the footing.
B: Footing width, in feet
K = 1 + 0.33(D/B) £ 1.33
D: Depth from ground level to the bottom of footing, in feet.

Example 7: Determine soil bearing capacity by SPT numbers


Given

Soil SPT number: 10


Footing type: 3 feet wide strip footing, bottom of footing at 2 ft below ground surface.

Requirement: Estimate allowable soil bearing capacity based on.


Solution:
Meryerhof's equation
K = 1+0.33(D/B) = 1+0.33*(2/3) = 1.22
Qa = (N/4) / K = (10 /4) /1.22 = 2 kips/ft2
Bowles’ equation:
Qa = (N/2.5) / K = (10 /2.5) /1.22 = 3.3 kips/ft2

www.ce-ref.com/Foundation/Bearing capacity/SPT.html 1/2


05/12/2019 SPT
Example 8: Determine soil bearing capacity by SPT numbers

Given:

Soil SPT number: 20


Footing type: 8 feet wide square footing, bottom of footing at 4 ft below ground surface.

Requirement: Estimate allowable soil bearing capacity based on Meryerhof’s equation.


Solution:
Meryerhof’s equation
K = 1+0.33(D/B) = 1+0.33*(4/8) = 1.17
Qa = (N/6)[(B+1)/B]2 / K = (20/6)[(8+1)/8]2 /1.17 = 3.6 kips/ft2
Bowles’ equation:
Qa = (N/4)[(B+1)/B]2 / K = (20/4)[(8+1)/8]2 /1.17 = 5.4 kips/ft2

Related topics

Pressure under footing

Foundation settlement

Spread footing design

Combined footing design

Strap footing design

RC retaining wall design

Home | About | Calendar | Contact | Employees | Employment | FAQ | Information Links | News | Photo Gallery | Press | Products |
Promotions | Services | Site Map

Disclaimer: The content of this website was obtained and edited from various resources. The editor made reasonable effort of
editing. Nevertheless, the editor does not warrant, and assume no liability for accuracy and completeness of its content. The viewer
shall use his/her professional knowledge and judgment in use of the web content. Webmaster: www.ce-ref.com

Copyright: www.ce-ref.com. All Rights Reserved.

www.ce-ref.com/Foundation/Bearing capacity/SPT.html 2/2

You might also like