Philippe Lebrun
CERN, Geneva, Switzerland
3000
NbTi @ 4.5 K
NbTi @ 1.8 K
2500 Nb3Sn @ 4.5 K
LHC Spec Cable 1
LHC Spec Cable 2
2000
Jc [A/mm2]
+ 3 tesla
1500
1000
500
0
6 7 8 9 10 11 12
B [T]
Cryogenic system layout
• 5 cryogenic islands
• 8 cryogenic plants, each serving adjacent sector, interconnected when possible
• Cryogenic distribution line feeding each sector
Configuration of cryogenics at LHC even point
Surface
Warm Warm Warm Warm
Compressor Compressor Compressor Compressor
Station Station Station Station
Shaft
Lower
Cavern
Cold Box
Cold Cold
Compressor Compressor
box Interconnection
Interconnection Box
Box box
Tunnel
Distribution
Distribution Line
Line Distribution Line Line
Distribution
Analysis Management
• Heat inleaks
– Radiation 70 K shield, MLI
– Residual gas conduction Vacuum < 10-4 Pa
– Solid conduction Non-metallic supports
Heat intercepts
• Joule heating
– Superconductor splices Resistance < a few nΩ
• Beam-induced heating
– Synchrotron radiation }
– Beam image currents } 5-20 K beam screens
– Acceleration of photoelectrons }
– Beam halo absorbed in cold mass
Steady-state heat loads [W/m]
(Cryomagnets and distribution line in LHC arcs)
Qinstalled = Max [Foc (Fin Qstat + Qdyn nom); (Fin Qstat + Qdyn ult)]
50 10000
30 6000
20 4000
10 2000
0 0
YR PB WB YB Specif. Rev. As YR PB WB YB Specif. Rev. As
1987 1991 1993 1995 1997 2000 built 1987 1991 1993 1995 1997 2000 built
CL cooling [g/ s]
40
2000
30
1000 20
10
0 0
YR PB WB YB Specif. Rev. As YR PB WB YB Specif. Rev. As
1987 1991 1993 1995 1997 2000 built 1987 1991 1993 1995 1997 2000 built
Installed cooling duties in the LHC sectors
Temperature
High-load sector Low-load sector
level
20-280 K 41 27 [g/s]
Evolution of installed power to heat load ratio
3
50-75 K 5-20 K 1.9 K CL cooling
2.5
Capacity ratio [-]
1.5
Overcapacity target
1
YR PB WB YB Specif. Rev. As
1987 1991 1993 1995 1997 2000 built
Procurement from industry
New Upgraded
Temperature level Unit
refrigerator refrigerator
20-280 K [g/s] 41 27
Scaling laws for cost of cryogenic He refrigerators
(single cold box, no LIN precooling, controls excluded)
How to specify an efficient He refrigerator
• Include capital & operating costs over amortization period (10 years)
in adjudication formula
• Operating costs dominated by electricity
• Include externalities in electricity costs => 60 CHF/MWh
– distribution & transformation on CERN site
– heat rejection in aero-refrigerants
• Establish shared incentive in the form of bonus/malus on measured
vs. quoted electrical consumption
• Break “high efficiency = high investment” pseudo-rule: for given
(specified) output, a more efficient plant is smaller, resulting in lower
investment (direct & indirect) as well as cheaper operation
How to make an efficient refrigerator
(exemplified on Carnot cycle schematic)
T isentropic T
Ideal Real adiabatic
Tw B A B A
Tw
Work Work
Tc Tc
C D C D
Cooling power
S ∆S1 ∆S2 S
Widen the low-temperature end of the cycle as shown in the T-S diagram
E1
Process cycle & T-S diagram
T1
of 18 kW @ 4.5 K cryoplant
E3
E4 T2
20 K - 280 K loads
(LHC current leads)
Pa
Pa
Pa
M
M
LN2
1
1.
0.
0.
Precooler
201 K
50 K - 75 K loads T1
E6 T3 from LHC loads
(LHC shields)
E7 T2
75 K
T3
E8 T4
49 K
LHC shields
Adsorber 32 K
E9a
T4
20 K
E9b
13 K T5 T7
from LHC loads
10 K
E10 T5 T7
4.5 K - 20 K loads
9K
(magnets + leads + cavities) T8
T6
E11
4.4 K
Pa
M
3
0.
T6
E13 T8
Compressor station of 4.5 K refrigerator
HP supply
ORS 1680 g/s @ 20 bar
MP return
880 g/s @ 3.9 bar
LP return
800 g/s @ 1.05 bar
Oil removal system
HP
MP
LP
4.5 K supply
20 K return
50 K supply
75 K return
300 K 75 K 50 K 20 K 4.5 K
Cold box of Air Liquide 4.5 K refrigerator
Cold box of Linde 4.5 K refrigerator
HP
MP
LP
4.5 K supply
20 K return
50 K supply
75 K return
300 K 90 K 75 K 50 K 20 K 4.5 K
Cold box of Linde 4.5 K refrigerator
Guaranteed vs measured performance
of the new LHC 4.5 K refrigerators
500
400
C.O.P. [W/W @ 4.5K]
300
200
100 Carnot
Limit
0
TORE RHIC TRISTAN CEBAF HERA LEP LHC
SUPRA
Liquid nitrogen precooling
1000
SUPER-
CRITICAL
Pressure [kPa]
He II He I
CRITICAL
100 POINT
PRESSURIZED He II SATURATED He I
(Subcooled liquid)
10
VAPOUR
Compression > 80
SATURATED He II
1
0 1 2 3 4 5 6
Temperature [K]
• Compress large mass-flow rate of gaseous helium across high pressure ratio
⇒ maximum density at suction, i.e. cold
• Non-lubricated, contact-less machinery ⇒ hydrodynamic compressor, multistage
• Heat of compression rejected at low temperature ⇒ high thermodynamic efficiency
Main Features of LHC Cold Compressors
300 K under
atmosphere
Active 3-phase induction
magnetic electrical motor
bearings (rotational speed
200 to 700 Hz)
Fixed-vane
diffuser
Outlet
Cold under
Spiral volute
vacuum
Axial-centrifugal
impeller (3D)
Pressure ratio Inlet
2 to 3.5
Cold hydrodynamic compressors for the LHC
IHI-Linde Air Liquide
Specification of LHC 1.8 K refrigeration units
4.5 K
CCB WCS
D
0.13 MPa, 4.5 K refrigerator below 30 K
20 -30 K (reduced capacity) to 20 K
C (installed capacity).
0.3 MPa
4.6 K – Capacity check in standalone
mode (Interface B closed)
B
LHC Sector
Load
LHe 1.8 K Q1.8K
1.8 K refrigeration cycles for the LHC
1.8 K Refrigeration Unit Cycles
4.75 bar 9.4 bar
WC
0.59 bar WC WC
0.35 bar WC HX
HX Adsorber
Adsorber
Intercepts
CC Heat
T
HX
4.6 bar
HX
CC
T
CC CC
T
CC
CC
CC
4 K, 15 mbar 20 K, 1.3 bar
124 g/s 124 g/s CC
P2
2 80 LHC
2' 70 CEBAF
800
600
400
0
Air Liquide IHI-Linde
Controls for LHC cryogenics
Challenges & solutions
4.5 K
Tunnel 1.8 K units QUI Common TOTAL
refrigerators
• Supervision layer
- Interface for operation team
- All operators action are
taken from this level
• Field layer
- Interface to process direct
I/O Boards, Fieldbuses
Operator-friendly SCADA
Animated
synoptics
PID
controllers
Trend charts
Alarm &
event lists
Some references
• Ph. Lebrun, Cryogenics for the Large Hadron Collider, IEEE Trans. Appl.
Superconductivity 10 (March 2000) 1500-1506
• S. Claudet, P. Gayet & U. Wagner, Specification of four new large 4.5 K
helium refrigeration systems for the LHC, Adv. Cryo. Eng. 45B (2000)
1269-1276
• S. Claudet, P. Gayet, B. Jager, F. Millet, P. Roussel, L. Tavian & U. Wagner,
Specification of eight 2400 W @ 1.8 K refrigeration units for the LHC, Proc.
ICEC18 Mumbai, Narosa (2000) 207-210
• Ph. Lebrun, Large cryogenic refrigeration system for the LHC, Proc.
ICCR’2003 Hangzhou, IIR (2003)
• H. Gruehagen & U. Wagner, Measured performance of four new 18 kW @
4.5 K helium refrigerators for the LHC, Proc. ICEC20 Beijing, Elsevier (2005)
991-994
• L. Serio et al., Validation and performance of the LHC cryogenic system
through commissioning of the first sector, Adv. Cryo. Eng. 53B (2008)
1411-1418
• S. Claudet, Ph. Lebrun, L. Serio, L.Tavian, R. van Weelderen & U. Wagner,
Cryogenic heat load and refrigeration capacity management at the Large
Hadron Collider, presented at ICEC22 Seoul (2008)