You are on page 1of 17

Eclipse Software Release

Notes
Version 4.1
P/N 260-668060-001 Rev 031.
21st September 2007

www.harrisstratex.com 10/8/2007 1352 1352-084-Eclipse Software Customer Release Notes.doc Page 1 of 17


Release Notes White Paper

Copyright © 2007 by Harris Stratex Networks.


All rights reserved. No part of this publication may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language or computer
language, in any form or by any means, electronic, magnetic, optical, chemical, manual or
otherwise, without the prior written permission of Harris Stratex Networks.

DISCLAIMER
Harris Stratex Networks makes no representation or warranties with respect to the
contents hereof and specifically disclaims any implied warranties or merchantability or
fitness for any particular purpose. Further, Harris Stratex Networks reserves the right to
revise this publication and to make changes from time to time in the content hereof
without obligation of Harris Stratex Networks to notify any person of such revision or
changes.

TECHNICAL SUPPORT
If you require technical assistance or if you have discovered a product issue, please
contact the Technical Help Desk nearest to you as soon as possible. Their contact
details are shown below:

USA Europe, Middle East & Asia/Pacific


Africa
Harris Stratex Networks Harris Stratex Networks
120 Rose Orchard Way Harris Stratex Networks Bldg 10 Unit B, Philexcel
4 Bell Drive Industrial Park
San Jose, CA 95134 -1358
Hamilton International Technology Clark Special Economic Zone
Phone: +1 800 227 8332 free
within US only Park Clark Field
Blantyre, Scotland, G72 0FB Pampanga
Harris Stratex Networks United Kingdom Philippines
5727 Farinon Drive Phone : +44 1698 714 073 Phone: +63 45 599 5192
San Antonio, TX 78249
Phone: +1 866 882 5381 free Harris Stratex Networks E-mail: Asia.Help@hstx.com
within US only Centrale Parc, Bâtiment 4 Pasteur TAC.APAC@hstx.com
Avenue Sully Prud'homme
E-mail: Americas.Help@hstx.com 92298 Châtenay-Malabry Cedex
TAC.AM@HSTX.com France
Phone : 33-1-55-52-80-00

E-mail: EMEA.Help@hstx.com
TAC.EMEA@hstx.com

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 2 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Table of Contents
Scope and Purpose .......................................................................................................... 4
Software Introduction........................................................................................................ 4
Supported Functionality .................................................................................................... 5
Configuration..................................................................................... 5
Diagnostics ....................................................................................... 6
Protection Support ............................................................................. 7
Communications & Networking............................................................. 7
Miscellaneous Features ....................................................................... 7
Alarms.............................................................................................. 7
Logs................................................................................................. 7
Security............................................................................................ 8
Software Loading ............................................................................... 8
Portal Help ........................................................................................ 8
Compatibility ..................................................................................................................... 9
Eclipse Hardware Supported ................................................................ 9
Operating Systems Supported............................................................ 12
Computer Hardware Supported .......................................................... 13
Regional Settings Supported .............................................................. 13
Network Time Protocol (SNTP) Servers Supported ........................................................ 14
Closed Field Issues ........................................................................................................ 14
Closed Significant Issues................................................................................................ 14
Portal and Embedded Compatibility History.................................................................... 14
Important Notes .............................................................................................................. 16

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 3 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Scope and Purpose


This document provides software release information on supported functionality,
compatibility, and known customer affecting issues, relating to the released software
versions.
The intended users of this document are:
• Harris Stratex Networks Customers
• Harris Stratex Networks Value Added Resellers
• Harris Stratex Networks Value Added Service Providers
• Harris Stratex Networks Product Support staff
• Harris Stratex Networks Field Service staff

Software Introduction
This software has been made available for customer release. In addition to previously
supported hardware and functionality it now provides additional support for:
• RAC 4X Support
• 2xSTM-1 128QAM
• 75xE1 16QAM
• 93xE1 256QAM
• 100xE1 32QAM and 128QAM
• 1xSTM-1 16QAM
• 127xDS1 64QAM and 128QAM
• 1xOC-3 16QAM and 64QAM
• 2xOC-3 256QAM
• IDU 300 20x v2 – added E1 performance monitoring
• GCAS 3344 – RAC 40 not recovering after fading activity

Product Part Number Version Build HSX


Reference #

Eclipse Embedded 275-250219-040116 4.1 16 1341-102


Software
Eclipse Portal Software 280-200010-0400259 4.0 259 0184-093

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 4 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

This release is supported by ProVision Element Manager System software version 6.0.1
with the following exceptions:
• Protected links are not supported in a ring configuration.
• Device type is not displayed correctly for the IDU 300 20x v2.
• New capacities supported by this release may not be displayed correctly in the
ProVision reports.

• E1 performance monitoring is not supported.

Supported Functionality
The following headings list functionality that is currently supported by version 4.01
embedded and Portal software. Additional functionality (since version 4.0) is highlighted
in bold italics.

Configuration
• Populate information fields such as terminal name, site name, etc
• View expected plug-in layout
• Configure frequency, power, modulation and capacity
• Configure tributary interface parameters
• Configure DAC ES ports
• Configure circuits
• Configure IP routing
• Set radio date and time
• Manage software versions and download
• View active license and download license
• Configure ring protection
• Configure dynamic routing
• View equipment part numbers and serial numbers
• Configure custom T/R splits
• Configure trap destinations
• Configure XP4 compatibility mode
• Configure ring wrap and unwrap criteria
• Configure system function names
• Configure ring unwrap time
• Configuration backup & restore
• RWPR for DAC GE
• Layer 2 link aggregation
• Layer 1 link aggregation with redundancy
• E1/DS1 backplane for DAC GE

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 5 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

• Status forwarding for DAC GE


• DAC GE - Generic L2 Link Aggregation and Enhanced VLAN usability
• E1 performance monitor
• Performance and Monitoring
• View RSL
• View G.826 15-minute and daily registers
• View history graphs and reports
• View real time G.826
• View event log and view event history
• View temperature values
• View forward power data
• View available supply voltages
• Estimated BER (G.821) performance monitor for link history reports
• Save performance data to file
• View Ethernet performance statistics
• View Ethernet performance history
• View combined performance data for 1+1 protected links
• G.826 Performance statistics are available for the offline receiver in a 1+1 link.

Diagnostics
• Activate tributary/AUX line facing loop back
• Activate tributary/AUX radio facing loop back
• Activate digital loop back
• Activate IF loop back
• Activate circuit loopbacks
• Transmit AIS on individual tributaries
• Enable TX PA mute
• View system summary
• View problem and severity indicators
• Disable ATPC
• Enable DAC PRBS
• Configure safety timers
• View and control ring status
• PRBS tester reset control
• Perform software rollback and reset
• Clear event log
• Troubleshoot Ethernet circuits

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 6 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Protection Support
• Equipment protection supported
• Hitless path protection supported
• Unidirectional ring protection supported
• Optical tributary protection supported
• IDU 300 20x v2 Hot Standby Non-Protected Tributary

Communications & Networking


• Serial interface supported
• SNMPv2 interface supported
• Ethernet interface support
• NMS overhead channel supported
• Static routing supported
• OSPF routing supported
• RIP II routing supported
• Configure default gateway
• Discover radios on local LAN

Miscellaneous Features
• Manufacturing details supported
• Watch dog supported
• ATPC supported
• Portal auto-version supported (upload Portal from radio)
• Soft reset without interrupting traffic
• As-built report supported
• Data file to send to Stratex Help Desk
• Manage Eclipse via XP4 links
• Launch new Portal session for remote terminal

Alarms
• Alarm hierarchy supported
• User configurable alarm thresholds
• Alarm I/O supported

Logs
• Event log operational
• Informational event log entries
• Event log notes

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 7 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Security
• Features controlled by license key
• Portal user security
• Auto-login support for ProVision

Software Loading
• Software loading – internal users only
• Software loading – customer usable

Portal Help
• Customer support details
• About Eclipse Portal
• Eclipse Help integration with alarm troubleshooting entries

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 8 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Compatibility
Eclipse Hardware Supported

The following table details the hardware that is supported by this software and
corresponding part numbers.
Hardware Type Part Number Description

IDC EXC-001, EXC-002 Indoor Chassis, 1RU

IDCe EXE-001 Indoor Chassis, 2RU Extended

NCC EXN-001, EXN-002 Node Controller Card

FAN EXF-001, EXF-002 Fan Card

FAN 2RU EXF-101 2RU Fan Card - INUe

INU EXX-000-001, EXX-000-002 Intelligent Node Unit, 1RU

INUe EXX-000-201, EXX-000-202 Intelligent Node Unit, Extended

NPC EXS-001 Node Protection Card

IDU 100 8x EXB-081-001 Indoor Unit, 8xE1, QPSK

IDU 100 16x EXB-161-001 Indoor Unit, 16xE1, QPSK

IDU 100 20x EXB-201-001 Indoor Unit, 20xE1, Hot Standby

IDU 300 8x EXG-081-001 Indoor Unit, 8xE1/DS1

IDU 300 20x EXG-201-001 Indoor Unit, 20xE1/DS1, Hot


Standby

IDU 300 20x v2 EXG-231-001 Indoor Unit, 20xE1/DS1, Hot


Standby, version 2

IDU 300 ES EXG-211-001 Indoor Unit, Fast Ethernet +


8xE1/DS1

IDU 300 SP 4x EXG-041-001 Indoor Unit, 4xE1, QPSK

IDU 300 SP 16x EXG-161-001 Indoor Unit, 16xE1, QPSK, Hot


Standby

IDU 300 155o EXG-999-001 Indoor Unit, 1xSTM-1/OC3, Hot


Standby

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 9 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

AUX EXA-001 Auxiliary and alarm I/O card

DAC 4x EXD-040-001 Data Access Card, 4xE1/DS1

DAC 16x EXD-160-001 Data Access Card, 16xE1/DS1

DAC 155o EXD-152-001 Data Access Card, 1xSTM-


1/OC3, Optical

DAC 155oM EXD-153-001, EXD-156-001 Data Access Card, 1xSTM-1/OC3


Multiplexed to 63E1/84DS1,
Optical

DAC ES EXD-171-001 Data Access Card, 10/100baseT


Fast Ethernet

DAC GE EXD-180-001 Data Access Card, Gigabit


Ethernet

DAC 2x155e EXD-254-001 Data Access Card, 2xSTM-


1/OC3, Electrical
DAC 3xE3/DS3 EXD-330-001 Data Access Card, 3xE3/DS3,
tributary protection
DAC 3xE3/DS3M EXD-331-001 Data Access Card,
3xE3/DS3,tributary protection,
2xE3 Mux ports for framed E3 to
E1 Bus or transparent E3
(34Mbps pipe) to 17E1
RAC 10 EXR-011-001 Radio Access Card, ODU 100
RAC 10 v2 EXR-011-002 Radio Access Card, ODU 100,
version 2
RAC 30 EXR-999-001, EXR-999-002 Radio Access Card, ODU 300
RAC 30 v3 EXR-999-003 Radio Access Card, ODU 300,
version 3
RAC 40 EXR-966-001 Radio Access Card, ODU 300
RAC 3X EXR-900-001 Radio Access Card, ODU 300
RAC 4X EXR-906-001 Radio Access Card, ODU 300

Hardware Part Number Description


Type

ODU 100 ECS-07-0154-* ECS-07-0161-* ECS-07-0196-* Frequency bands supported


ECS-07-0245-* ECS-08-0119-* ECS-08-0126-* are:
ECS-08-0151-* ECS-08-0266-*ECS-08-0311-* 7, 8, 11, 13, 15, 18, 23, 26, 31,
ECS-08-0305-* ECS-11-0490-* ECS-11-0500-* 32, 38 GHz
ECS-11-0530-* ECS-13-0266-* ECS-15-0315-*
Note: the software supports
ECS-15-0420-* ECS-15-0490-* ECS-15-0644-*
these frequency bands/splits
ECS-15-0728-* ECS-18-0340-* ECS-18-1010-* however the hardware option
ECS-18-1092-* ECS-23-0600-* ECS-23-1008-* may not exist.
ECS-23-1200-* ECS-23-1232-* ECS-26-1008-*
* All numbers supported

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 10 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

ECS-31-0225-* ECS-31-0410-* ECS-31-0450-*


ECS-31-0490-* ECS-31-1008-* ECS-31-1975-*
ECS-32-0812-* ECS-38-1260-*

ODU 300 EDH-05-0300-* EDH-05-0312-* EDH-06-0160-* Frequency bands supported


EP EDH-06-0170-* EDH-06-0252-* EDH-06-0340-* are:
EDH-07-0154-* EDH-07-0161-* EDH-07-0168-* 5, 6, 7, 8, 10, 11, 13, 15, 18,
EDH-07-0196-* EDH-07-0245-* EDH-08-0119-* 23, 26, 28, 31, 32, 38 GHz
EDH-08-0126-* EDH-08-0151-* EDH-08-0208-*
Note: the software supports
EDH-08-0266-* EDH-08-0305-* EDH-08-0310-*
these frequency bands/splits
EDH-08-0311-* EDH-10-0065-* EDH-10-0091-* however the hardware option
EDH-10-0143-* EDH-10-0230-* EDH-10-0350-* may not exist.
EDS-11-0490-* EDS-11-0500-* EDS-11-0530-*
* All numbers supported
EDH-13-0266-* EDH-15-0315-* EDH-15-0420-*
EDH-15-0475-* EDH-15-0490-* EDH-15-0644-*
EDH-15-0728-* EDH-18-0340-* EDH-18-1008-*
EDH-18-1010-* EDH-18-1092-* EDH-18-1120-*
EDH-18-1560-* EDH-23-0600-* EDH-23-1008-*
EDH-23-1200-* EDH-23-1232-* EDH-26-0800-*
EDH-26-0855-* EDH-26-1008-* EDH-28-0450-*
EDH-28-1008-* EDH-31-0225-* EDH-31-1975-*
EDH-32-0812-* EDH-38-0700-* EDH-38-1000-*
EDH-38-1260-*

ODU 300 EQS-07-0154-* EQS-07-0161-* EQS-07-0168-* Frequency bands supported


SP EQS-07-0196-* EQS-07-0245-* EQS-08-0119-* are:
EQS-08-0126-* EQS-08-0151-* EQS-08-0208-* 7, 8,11, 13, 15, 18, 23, 26, 28,
EQS-08-0266-* EQS-08-0305-* EQS-08-0310-* 31, 32, 38 GHz
EQS-08-0311-* EQS-11-0490-* EQS-11-0500-*
Note: the software supports
EQS-11-0530-* EQS-13-0266-* EQS-15-0315-*
these frequency bands/splits
EQS-15-0420-* EQS-15-0475-* EQS-15-0490-* however the hardware option
EQS-15-0644-* EQS-15-0728-* EQS-18-0340-* may not exist.
EQS-18-1008-* EQS-18-1010-* EQS-18-1092-*
* All numbers supported
EQS-18-1120-* EQS-18-1560-* EQS-23-0600-*
EQS-23-1008-* EQS-23-1200-* EQS-23-1232-*
EQS-26-0800-* EQS-26-0855-* EQS-26-1008-*
EQS-28-0450-* EQS-28-1008-* EQS-31-0225-*
EQS-31-1975-* EQS-32-0812-* EQS-38-0700-*
EQS-38-1000-* EQS-38-1260-* EFS-07-0154-*
EFS-07-0161-* EFS-07-0168-* EFS-07-0196-*
EFS-07-0245-* EFS-13-0266-* EFS-15-0315-*
EFS-15-0420-* EFS-15-0490-* EFS-15-0644-*
EFS-15-0728-* EFS-18-0340-* EFS-18-1120-*
EFS-18-1560-* EFS-23-0600-* EFS-23-1008-*
EFS-23-1232-* EFS-38-1260-*

ODU 300 EAH-06-0252-* EAH-06-0160-* EAH-06-0170-* Frequency bands supported


HP EAH-06-0340-* EAH-07-0154-* EAH-07-0161-* are:
EAH-07-0168-* EAH-07-0196-* EAH-07-0245-* 6, 7, 8, 11, 13, 15, 18, 23, 26,
EAH-08-0119-* EAH-08-0126-* EAH-08-0152-* 28, 31, 32, 38 GHz
EAH-08-0208-* EAH-08-0266-* EAH-08-0306-*
Note: the software supports
EAH-08-0310-* EAH-08-0311-* EAH-11-0490-*
these frequency bands/splits
EAH-11-0500-* EAH-11-0530-* EAH-13-0266-* however the hardware option
EAH-15-0315-* EAH-15-0420-* EAH-15-0475-* may not exist.
EAH-15-0490-* EAH-15-0644-* EAH-15-0728-*
* All numbers supported
EAH-18-0340-* EAH-18-1008-* EAH-18-1010-*
EAH-18-1092-* EAH-18-1120-* EAH-18-1560-*

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 11 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

EAH-23-0600-* EAH-23-1008-* EAH-23-1200-*


EAH-23-1232-* EAH-26-0800-* EAH-26-1008-*
EAH-28-0450-* EAH-28-0900-* EAH-28-1008-*
EAH-31-0225-* EAH-31-1900-* EAH-31-1975-*
EAH-31-2050-* EAH-32-0812* EAH-38-0700-*
EAH-38-1000-* EAH-38-1260*

Operating Systems Supported


The following table details the supported Operating Systems.
Operating Notes
System

HP-UX 11i v1 -
Windows XP Pro Refer to Eclipse User Manual for XP support information
(SP1, SP2)
Windows 2000 -
Pro (SP3)
Windows NT 4.0 -
Windows 98 -
Windows Vista New Portal Installer with Microsoft Vista Support

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 12 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Computer Hardware Supported


The following table details the minimum hardware specifications required to operate
Portal.
Attributes Minimum Specifications

Processor P3,500 MHz


RAM 256 MB
HD space (install and 80 MB
operate)
Monitor adaptor SVGA
Monitor display resolution 800 x 600
Monitor colours 256
Mouse Yes

Note: ATI video cards installed with a ‘Catalyst driver’ set earlier than 4.9 will cause the
Portal performance page to stop working if the screen-saver activates. The workaround
is to install the latest video drivers from the video card manufacturer.

Regional Settings Supported


Portal supports the following locales and there are no known limitations:
Albanian, Belarusian, Bulgarian, Catalan, Croatian, Czech, Danish, Dutch, English,
Estonian, Finnish, French, German, Greek, Hebrew, Hungarian, Icelandic, Italian,
Japanese, Korean, Latvian, Lithuanian, Macedonian, Norwegian, Polish, Portuguese,
Romanian, Russian, Serbian, Serbo-Croatian, Slovak, Slovenian, Spanish, Ukrainian.
The following table details known regional settings limitations.
Locales Known Limitations

Arabic The calendar does not display the day of the week correctly
Chinese The date format is not consistent in event browser, the calendar does
not display the day of the week correctly, and the alarms page is larger
than 800 x 600 resolution
Hindi The alarms page is larger than 800 x 600 resolution
Swedish Commas are displayed instead of decimal points when entering the
TR/RX spacing and TX/RX frequency. Portal will accept commas when
the user enters TX/RX frequency, however it will not accept commas for
the TX/RX spacing.
The workaround is to use decimal points.
Thai Alarms page is larger than 800 x 600 resolution
Turkish Some event log entries in the event browser and link history pages may
not be displayed

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 13 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Network Time Protocol (SNTP) Servers


Supported
Eclipse software has been successfully tested with the following SNTP time servers.
• NetTime

Closed Field Issues


The following table lists field issues that have been fixed since the 4.0.57 release.
Trouble Issue Description
Ticket #

3344 RAC 40 : Demod not locking after fading activity in ring.


Ring networks were experiencing constant Demodulator alarms after
fading activities. This is now fixed.
5156 Rings : Wrap performance could exceed 150ms for protected links.
Ring wrapping performance has been improved for segments that
include protected links.

Closed Significant Issues


The following table lists significant issues that were discovered during
development/testing since the version 4.0.57 release. These issues have been fixed by
this release.
Software Type Issue Description

RAC 40 : Upgrade from v3.3 to 4.0.61 selects wrong profile


A very limited number of customers that experienced a RAC40 DNL
Embedded alarm condition were supplied an interim software build 4.0.61. When
upgrading from v 3.3 or earlier to 4.0.61, compatibility problems
relating to RAC40 profiles occurred. This is now fixed.

Portal and Embedded Compatibility History


Embedded Software Version Matching Portal Software Version

2.1.18 and later (Portal auto-version 2.1.1, Build 2112 and later
supported)
2.0.44 2.0.1, Build 2018
1.0.29 1.0.1, Build 1923
0.10.31 0.10.1, Build 1660

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 14 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

0.10.20 0.10.1, Build 1660 or 1722


0.9.32 0.9.2, Build 1358

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 15 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Important Notes
1. Traffic may be affected when upgrading software between two specific versions
of software. Contact a Harris Stratex Networks Technical Help Desk for details,
contact details are on page ii of these release notes.
2. When upgrading software ensure the remote end of a link is upgraded before the
local end. This is particularly important where the RAC 40 is involved.
3. When upgrading from version 2.5.63 or earlier to version 3.0.73 or later, an
interim version of software must be loaded first. The interim versions that can be
used are 2.6.58, 2.8.5, 2.8.6, 2.9.51, 2.9.66, or 2.9.69.
4. Portal Help integration requires Stratex Help revision 014 or higher. Stratex Help
is a standalone help program that is installed separately to Portal, it can be found
on the Eclipse Setup installation CD.
5. A license upgrade requires a power cycle if the backplane type changes.
6. A power cycle or a RAC reinsertion is required if a capacity change exceeds the
license capacity size.

7. To reduce the traffic outage time during a software load of an IDU 100 1+1
protected radio the following steps should be observed:
a. Lock all units to TX/RX on the Primary and load only to the high band
Secondary IDU/ODU pair
b. Keeping all units TX/RX locked on the Primary, load only to the low
band Secondary IDU/ODU pair
c. Switch all units to TX/RX on the Secondary and lock them there
d. Keeping all units TX/RX locked on the Secondary, load only to the high
band Primary IDU/ODU pair
e. Keeping all units TX/RX locked on the Secondary, load only to the low
band Primary IDU/ODU pair
f. Switch all units back to TX/RX auto
8. Care should be taken not to run OSPF and Static routing within the same internal
OSPF routing domain.
9. If Portal loses communication with an IDU 300 SP radio when changing the IP
address, restart Portal to restore communication.
10. Disable any PC firewalls before performing a software download.
11. The channel authentication feature introduced in release v4.0 may cause a
possible problem when upgrade the software. This incompatibility happens only
with current DAC-GE customers that are using:
- Transport Channel Mode sets in “Rapid Failure Detection” or “Rapid Failure
Detection and Protection”,
- Two ends of DAC-GE link have different versions (one end with v4.0 and other
end with previous version v3.7 or lower).
The following steps or procedure for upgrading software are recommended in order
to minimize user traffic impact on DAC-GE:

Step 1: Before downloading new software v4.0 to both ends, change Transport
Channel Mode in both ends to “No Failure Detection - ES Compatibility” in
Portal

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 16 of 17


Copyright © 2007 Harris Stratex Networks, all rights reserved.
Release Notes White Paper

Step 2: Download both ends with new software v4.0. After activated both ends
with new version, change Transport Channel Mode in both ends back to the
original one (“Rapid Failure Detection” or “Rapid Failure Detection and
Protection”).

Harris Stratex Networks encourages its customers to report problems so we can resolve
them as quickly as possible.
If you encounter a technical issue, please contact us using the information on page 2 of
these Release Notes.

10/8/2007 1352-084-Eclipse Software Customer Release Notes.doc Page 17 of 17