Professional Documents
Culture Documents
OUTPUT
CALCULATIONS
PART-I
(A) EFFECTIVE LENGTH REMOVED FROM HEADER
d1 (in) 4.285
(B) PRESSURE DESIGN THICKNESS
th (in) 0.080
tb (in) 0.042
(C) REINFORCING ZONE BOUNDARY
4.285
Zone)
L4 (Height of Reinforcing Zone outside 0.268
of Run pipe)
PART-II : AREAS (sq. in)
A1 (Required Reinforcement Area) 0.344
A2 (Excess Area available in Header) 0.435
A3 (Excess Area available in Branch) 0.035
A4 (Branch Weld area) 0.055
A2+A3+A4 0.525
Reinforcement Pad Required No
.
API 5L Grade A
API 5L
S
4
40
4.5
0.237
19
0.207
31.3
16000
1.00
0.4
1.0