Any commercial lighting project for a typical mall, or atrium, starts with selection of the
lamps, or light sources.Most property owners prefer to use as few lamp types as possible
to reduce maintenance and stocking costs. Four or ve lamp types is a good compromise
in most cases, but most lighting designers try to stay with one lamp wattage for each
major type speci ed.In specifying the stable

Joseph R. Knisley
APR 01, 1998

Any commercial lighting project for a typical mall, or atrium, starts with selection of the
lamps, or light sources.
Most property owners prefer to use as few lamp types as possible to reduce maintenance and
SEARCH

stocking costs. Four or five lamp types is a good compromise in most cases, but most lighting
designers try to stay with one lamp wattage for each major type specified.

In specifying the stable of lamps, consider using the following products: HID lamps (metal
halide is the only real choice), fluorescent lamps (today's popular T8 model), PAR halogen
lamps, compact fluorescent sources, and one or two incandescent lamps for accent or sparkle.

Energizing the metal halide lamp The metal halide (MH) light source is an excellent choice for
providing the ambient, or general lighting level in a shopping plaza. The layout of such lamps
should produce 20-fc horizontal, or less, of illumination. New, low-wattage MH lamps can be
applied in ceilings as low as 9 ft. For example, many designers now use MH lamps of 175-W to
250-W ratings to handle general down lighting from high ceilings. This method excludes using
a high-wattage light source that could cause distracting glare to shoppers circulating through
the area.

The single-ended MH lamp is available in a standard universal burning line, a standard


position-restricted line, a safety line, and a special shrouded arc tube line. Standard universal
burning lamps, the most widely used type, can be operated in any burning position from base-
up to base-down. They are available in clear and phosphor-coated versions, in both mogul and
medium-base designs.

Standard position-restricted lamps provide optimum output because of the construction of


their arc tubes. When a universal-burning, straight-arc-tube MH lamp is burned horizontally,
its arc tends to bow upward because of convection currents; thus, a lamp having an arc tube
bent in conformity to this natural bowing process would be position restricted.

The lumen output of a bent-arc-tube lamp is considerably higher than a horizontally burning,
straight-arc-tube lamp of the same wattage. The safety-line MH lamp uses a method of
disconnecting the power to the arc tube if the outer bulb is broken or shattered. This lamp
type is recommended for use in open bottom fixtures. The shrouded arc tube line of MH lamps
is for use in open fixtures where increased fixture efficiency and lower maintenance costs are
important. Basically, the shroud is a glass cylinder that surrounds the arc tube. Should ballast
fragments be discharged from a ruptured arc tube (at the end of lamp life), they will be
SEARCH
blocked from hitting the outer glass bulb and shattering it.

Also consider the new high-efficiency 350-W MH lamp that delivers 44,000 lumens compared
to 36,000 lumens produced by a standard 400-W lamp and the 40,000 lumens of a high
output 400/BU (base up) lamp. The lamp has wide application, particularly as replacement
for a line of lower wattage lamps in the 100-W to 400-W range.

The 350-W MH lamp's unique body arc tube also contributes to faster restart time. A standard
pinched-body arc tube typically uses a secondary smaller electrode in one end of the arc tube.
This starter electrode provides a small arc discharge inside the arc tube to facilitate
subsequent arc formation. Because of the narrow pinch seal area, a formed arc tube lacks the
room for the extra electrode. Consequently, a high-voltage ignitor provides the breakdown of
the gases to start the arc.

The high voltage pulse generally allows the lamp to start faster from a cold state; but more
importantly, the lamp ignites up to 60% faster than a conventional arc tube in a hot restart.
Additionally, color uniformity is enhanced, and the loss of lumens over time occurs more
slowly, resulting in a 40% improvement in mean lumens.
SEARCH

The new lamp type can be matched with a new 277-V linear reactor (LR) ballast, rather than
with a standard constant wattage autotransformer (CWA) ballast system, normally used with a
400-W MH lamp. The 350-W MH lamp/LR ballast combination saves 83 W and the light
output is equivalent to that of a 400-W lamp. The MH lamps features an average rated life of
20,000 hours and an apparent color temperature of 4000 K. It is worthwhile studying the
range of these lamps.

An often-overlooked specification in an HID system design for a public space is the ballast
noise rating. Premium-wound ballasts run cooler and quieter because they are potted or
otherwise acoustically dampened. An alternative solution is remote-mounting the ballast-
removing it from the fixture in the public space.

Fluorescent strips, hidden in an architectural cove, coffered ceiling, or crown molding, can
create bright, cheerful surfaces in a mall setting. The fluorescent source can be a component
of, or comprise all the ambient lighting. Introduced in the past two decades, T8 fluorescent
lamps use triphosphors that create the appearance of balanced white light. Available with
chromacities of 3000K, 3500K and 4100K, these lamps allow warm, neutral, or cool
atmospheres to be designed.

The T8 lamp is also available in a U shape with narrow leg spacings-giving designers several
options in 2-ft lamps for the increasingly popular 2- by 2-grid ceiling and corresponding
fixtures. The fluorescent lamp also comes in T10, T5 and T2 versions. The high-wattage, rapid-
start compact, single-ended fluorescent lamps such as GE's Biax , offer high lumen packages
in lamps as short as 18 inches. The four-pin, plug-based lamps operate at 18 W and 49 W.
These lamps can also be used in 2- by 2-ft fixtures.

Although they're the least efficient source, incandescent lamps offer a variety of beam
patterns, tight beam control, and an array of wattages. Used sparingly, they are ideal for
highlighting marble, granite, brass, glass, and other finishes.
The tungsten halogen lamp has gained great popularity, and is available in various sizes and
SEARCH
shapes. The lamp operates using the halogen, or iodine, cycle. In this process, evaporated
tungsten particles return to the filament within the tubular bulb. This keeps the inside wall of
the bulb nearly completely free of blackening deposits of tungsten and maintains almost
constant light output over the lamp's life.

A family of halogen capsule 50-W PAR 20 lamps has a rated life of 2000 hours. They are
available in 120 V and 130 V, with narrow spot and narrow flood beams. These lamps are more
compact than standard 75-W R30 lamps, and they offer more precise optical control.

PAR 36 halogen lamps are also available in a low-voltage design with a number of beam
spreads. This type is offered in very narrow spot, narrow spot, wide flood, and very wide
floods.

Sconces, torcheres, lanterns, and lampposts bring a human scale to interior spaces and can
become signature decorative pieces that identify a plaza or court. Even if sparingly used,
custom decorative lighting fixtures can create character and a sense of scale while at the same
time providing basic building illumination. If desired, they can also be a visible, apparent light
source.

LATEST IN CEE NEWS MAGAZINE ARCHIVE

Search Results
DEC 10, 2003
CEE News Magazine Archive
SEARCH

Poll Results
DEC 05, 2003
CEE News Magazine Archive

Email This Article


DEC 05, 2003
CEE News Magazine Archive

404 Error Message


DEC 05, 2003
CEE News Magazine Archive

Sign up for EC&M eNewsletters

Email address SIGN UP

CEE NEWS MAGAZINE ARCHIVE

Search Results
DEC 10, 2003
SEARCH

LATEST IN CEE NEWS MAGAZINE ARCHIVE

Poll Results
DEC 05, 2003
CEE News Magazine Archive

Email This Article


DEC 05, 2003
CEE News Magazine Archive

404 Error Message


DEC 05, 2003
CEE News Magazine Archive

Joe Tedesco, Author of Code Violations Illustrated


FEB 19, 2003
CEE News Magazine Archive

Load More Content


About Us Contact Us Advertise Privacy & Cookie Policy Terms of Service SEARCH

© 2019 Endeavor Business Media, LLC. All rights reserved.

You might also like