You are on page 1of 3

QUOTATION

To, Ref : AE:MKG:25092017


GULAB DEVI HOSPITAL,
JALANDHAR
Date : 25/09/17

DESCRIPTION:
100mA X-Ray Machine (APR Model), Mobile with Stationary Anode Tube

Enclosed: Technical Specifications


MODEL: AE 100
AERB, BIS, ISO AND CE CERTIFIED

100mA X-Ray Machine RS/-1,50,000


(APR Model), Mobile (One Lakh Twenty Five Thousand )Only
with Stationary Anode
Tube

TERMS:
Taxes Extra as GST@12%.
Prices inclusive of Transportation
Payment: 100% advance
Warranty: Standard Warranty for 12 months from the date of Installation or 13 months from the
date of dispatch whichever is earlier.
Delivery: within 21 Days from the receipt of Order and advance.
Looking forward to your valuable order.

Regards
For ADONIS Medical Systems Pvt. Ltd

Authorized Signatory
TECHNICAL SPECIFICATIONS AND COMPOSITION

EQUIPMENT: 100mA X-Ray Machine (APR Model), Mobile with Stationary Anode Tube

MODEL: AE 100

 BIS 7620 Part I Approved for Mechanical & Electrical Safety.

 AERB Approved for Radiation Safety.

 ADONIS is an ISO 9001 : 2008 and ISO 13485 : 2003 Company

 CE Marked Equipment
100 mA diagnostic X-Ray Machine is designed to fulfill the requirements of All Radiological
needs. The equipment incorporates many performance advances that provide a New level of
efficiency, System reliability and simplicity of operations.

 SOFT TOUCH KEY BOARD SYSTEM

 KVp, Technic and mAs can be automatically selected by selecting the Body Part.

 Each Key can be reprogrammed at the customer’s place as per customer requirements.

 2 Step kVp and Single Step mAs for better Radiographic results.

 Illuminated LCD Display.

 Digital meter for Main Line voltage display for accurate exposure.

 An indigenous product. Service capability available at all service centers in India.

 Microprocessor Based Electronic Overload Protection for Better Tube Safety Life.

 Microprocessor Based Electronic Exposure control for accurate Exposure.

 Stand by Circuitry: Machine can still operate in case of failure of Main control Panel.

 Exposure Counter: Machine is provided with Exposure counter to keep track of total
exposures taken.

 Automatic Selection of Bucky: No need to remember the activation of Bucky, Bucky


will be automatically switched ON where required.
COMPOSITION :

 100 mA Auto Programmable X-Ray Generator


 X-Ray Column
 Mobile Base
 Tube carriage
 Tube Head
 Manual Collimator
 Counter Balance Weight
 Generator cover
 Hand switch
 Operation Manual

TECHNICAL SPECIFICATIONS

1. Radiographic Rating : 40 – 100 KVp .

2. Tube Current : 25 mA, 50 mA, 75 mA and 100 mA

3. Tube Voltage : 40 – 100 kVp in Steps of 2 kVp

4. Timer : 2-300 mAs

5. Rectification : Full Wave rectified.

6. X-Ray Tube : Stationary Anode Tube


2.8 mm x 2.8 mm focal spot.

7. Collimator : Manual Light Beam Diaphragm.

8. Movements : Fully Counter Balanced, Vertical, in and out, Angular


Travel and Tube Up & Down

9. Cassette Box : Integrated Cassette Storage

10. Power Supply : 230 V, 50 Hz.

11. Overall Dimensions. : Can be moved around and in the lift.

12. Extension Operating Switch: With 2 meters cable Length.