MV SERIES - 60Hz
Boost
the pressure
and your
confidence
& 14001 : 2
: 2008 004
01 CO
90
MP
AN ISO
ANY
foundry. Eventually the founder's dream was coming true as the small
production unit he started kept growing rapidly. Now, after more than
C . R . I . I S O N E A M O N G
the few pioneers in the world to produce 100% stainless steel
THE INFRASTRUCTURE
of C.R.I. is pretty comprehensive with state-of-the-art machineries
and a high potential R&D wing, all within its own covered area of
with ISO 9001 & 14001 certifications. The R&D team always stays
N E E D L E S S T O S A Y ,
behind this legendary growth lies the untiring, innovative,
V E R T I C A L M U LT I S TA G E C E N T R I F U G A L P U M P S - M V S E R I E S
G E N E R A L
C.R.I. Vertical Multistage centrifugal pumps ( MV series) are non-self priming, axial suction and delivery
type available with DIN standard port connections. All components like impellers, diffusers & shaft of
these pumps are made of corrosion resistant AISI stainless steel and designed to deliver the best
possible hydraulic efficiency. As the diffuser chambers, impellers, shaft & pump base (casing) are made
of high grade stainless steel S.S. 304/316, these pumps can be used to pump clear water
and are quite hygienic to use in drinking water systems too. ‘O’ rings and gaskets prevent leakage at the
intermediate casing during high pressure. The replacement of the seal can even be done in the installed
position without removing the pump from the booster system. These pumps are reliable, easily serviceable
and used in water boosting units to get trouble free service for years together.
C.R.I. Multistage Vertical pumps are powered by a Totally Enclosed Fan Cooled, A.C. induction motor,
suitable for continuous duty. Motor stator is made of low watt loss steel laminations assembled under
pressure and rigidly locked in the frame. Dynamically balanced rotor ensures vibration and noise free
operations. The varnished impregnated windings made of enamelled copper wire offer excellent resistance.
Shaft of ample size made of quality steel and precisely ground is used for transmitting the rated
Horsepower. Construction of motor frames and usage of quality materials result in high performance and
low temperature rise thereby increasing the life cycle of the motor. Thermal over load protector is
incorporated in all single phase motors. These pumps require an adequate control system.
Applications : l
Pressure boosting l
Reverse osmosis system l
Fire fighting systems l
Industries & General
4
VERTICAL MULTISTAGE PUMPS
MODEL IDENTIFICATION CODE
M X X - XXX / XX X X X
Impeller Type
Multistage A = Trimmed impeller
Centrifugal B = Extra trimmed impeller
Type
V - Vertical Type of port connection
R = Round
Type of Materials of Construction (M.O.C) P = PJE
Diffuser Chamber / Impeller / Pump base (casing) / Base plates
Suc & Del Ports Phase - Connection
S = S.S.304 / S.S.304 / S.S.304 / CI / S.S. 304 1 = Single Phase-PSC
N = S.S.316 / S.S.316 / S.S.316 / CI / S.S.316 2 = Single Phase-CSCR
C = S.S.304 / S.S.304 / CI / CI / CI 3 = Three Phase-DOL
Nominal 6 = Three Phase-SD
L = S.S.304 / S.S.304 / S.S.304 / S.S.304 / S.S.304
Flow
T = S.S.316 / S.S.316 / S.S.316 / S.S.316 / S.S.316 No of Impellers
(in m3/h)
Note : To include decimal values in the nominal flow from 0.1 to 0.8 alphabets A to H are used.
TECHNICAL DATA
PERFORMANCE RANGE
OPERATION LIMITS
Suction Lift Upto 21 Feet
Maximum Liquid Temperature - 4° to + 248°F
Maximum Ambient Temperature 104OF
Max. Operating Pressure Range 30 Bar
Starts per hour 200 Times upto 5.5 HP
100 Times above 5.5 HP
MV SERIES - 60 Hz 5
COMMITMENT | RELIABILITY | INNOVATION
I M P O R T A N T N O T E S
l Read our operator's manual carefully before installation l Pump should not be operated dry l Install dry run preventor to protect the
pumpset from dry running l Use appropriate size, good quality cable and starter / protection devices l Use low friction good quality pipes
l The pipe diameters must never be smaller than the pump connections l
Install pump according to our recommended Head range l
Reduce
number of bends, elbows, T-bends as much as possible in the pipe line lAll pumps employ a prime mover motor suitable for 230 volts single
phase or 415 volts three phase, 60 Hz, A.C supply l Avoid fatal electrical shock or injury by disconnecting power before working on or around
the pumping system l Only technically qualified personnel must perform the works complying with local electricity rules and regulations l
To
reduce the risk of electrical shock during operation, an appropriate earthing is mandatory l Maximum permissible supply voltage should lie
between ±10% l The performance data and curves are at rated voltage and only indicative Pipe sizes mentioned in inches are nominal pipe
l
MATERIALS OF CONSTRUCTION
Part Name Type - C Type - S Type - N
Pump Outer Jacket S.S. 304 S.S. 304 S.S. 316
Pump Bracket C.I. C.I. C.I.
Pump Base (Casing) C.I. S.S. 304 S.S. 316
Base Plate - C.I. C.I.
Impeller S.S. 304 S.S. 304 S.S. 316
Diffuser (Chamber) S.S. 304 S.S. 304 S.S. 316
Motor Frame AL / C.I. AL / C.I. AL / C.I.
Shaft S.S. 304 / 431 S.S. 304 / 431 S.S. 316 / S.S 329
Shaft Bush Bearings Sic Carbide / Tungsten Carbide Sic Carbide / Tungsten Carbide Sic Carbide / Tungsten Carbide
Sic Carbide & Sic Carbide / Sic Carbide & Sic Carbide / Sic Carbide & Sic Carbide /
Mechanical Seal
T.C. & Carbon, Viton T.C. & Carbon, Viton T.C. & Carbon, Viton
6
VERTICAL MULTISTAGE PUMPS
PERFORMANCE CURVE CONDITIONS
1000
300 H - (feet)
H - (m)
280
900
260
800
240
220
700
200
180 600
160
500
MV-025
140
120 400
100
MV-005
MV - 0 10
MV-020
MV-040
MV-080
MV - 160
MV-015
300
80
60 200
40
100
20
0 0
0 20 40 60 80 100 120 140 160 180 200
Q - (US gpm)
Q - (lps)
0 1 2 3 4 5 6 7 8 9 10 11 12 13
0 4 8 12 16 20 24 28 32 36 40 44
Q - (m³/h)
THE CONDITIONS BELOW APPLY TO THE CURVES SHOWN ON THE FOLLOWING PAGES.
l Curve tolerance are according to ISO 9906, Annex A l The performance are taken at rated voltage & speed that are only indicative
l Actual discharge depends on availability of water in well / tank, height of water column from the suction pipe end l The measurements
were made with airless water at 20°C when pumping liquids with a density higher than of water, motors with correspondingly higher
outputs must be used l The bold curves indicate the recommended performance range l Pipe friction losses have not been included in
the performance curves & performance tables l The pipe connection threads are given as per BSP standard l The given performance are
for specific materials of constructions l
The main scales of the performance curve are feet and US gpm which have been given for head and
flow respectively.
MV SERIES - 60 Hz 7
COMMITMENT | RELIABILITY | INNOVATION
MVC (ROUND FLANGE) MVS & N (PJE) MVS & N (ROUND FLANGE)
210.0
210.0
210.0
180.0
180.0
180.0
Ø13.0 X 4Nos Ø13 X 4Nos Ø13 X 4Nos
100.0 100.0 100.0
150.0 150.0 150.0
X X
X ØY
ØY ØY
L2
L2
L2
L4+L2
Z
L1+L2
Z
L3+L2
Z
154 Sq 154 Sq
154 Sq
(DIN)
PN 25 / DN 25 / 32 (DIN)
PN 25 / DN 25 / 32
L4
L1
L3
19 X 27 Ø42.40
(PJE) 19 X 27 Ø14.0 X 4Nos
PCD 85.0
105.0
89.0
100.0
89.0
75.0
75.0
50.0
Ø35.0 250.0 Ø32.0 210.0 Ø25.0 250.0
NPSHR CURVE
H - (m)
H - (feet)
5 16
4
12
NPSHR
3
8
2
1 4
0 0
0 1 2 3 4 5 6 7 8 9 10 11 12
Q - (US gpm)
Q - (lps)
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7
8
VERTICAL MULTISTAGE PUMPS
MV-5
NOMINAL FLOW : 5 GPM
H - (m) 260
H - (feet)
MV-005
MVS-005/27 3R 60 Hz
800
240 3450rpm
MVS-005/25 3R 80
220
EFFICIENCY(%)
700 60
MVS-005/23 3R EFF %
200 40
MVS-005/21 3R
600 20
180
MVS-005/19 3R
0
160 MVS-005/17 3R
500
140 MVS-005/15 3R
MVS-005/12 3R
MVS-005/11 3R
100
MVS-005/10 3R
300
MVS-005/09 3R
80
MVS-005/08 3R
MVS-005/07 3R
60 200
MVS-005/06 3R
MVS-005/05 3R
40 MVS-005/04 3R
100 MVS-005/03 3R
MVS-005/02 3R
20
0 0
0 2 4 6 8 10 12
Q - (US gpm)
Q - (lps)
0 0.2 0.4 0.6 0.8
MV SERIES - 60 Hz 9
COMMITMENT | RELIABILITY | INNOVATION
MVC (ROUND FLANGE) MVS & N (PJE) MVS & N (ROUND FLANGE)
210.0
210.0
210.0
180.0
180.0
180.0
Ø13.0 X 4Nos Ø13 X 4Nos Ø13 X 4Nos
100.0 100.0 100.0
150.0 150.0 150.0
X X
X ØY
ØY ØY
L2
L2
L2
L4+L2
Z
L1+L2
Z
L3+L2
Z
154 Sq 154 Sq
154 Sq
(DIN)
PN 25 / DN 25 / 32 (DIN)
PN 25 / DN 25 / 32
L4
L1
L3
19 X 27 Ø42.40 (PJE) 19 X 27 Ø14.0 X 4Nos
PCD 85.0
105.0
89.0
100.0
89.0
75.0
75.0
50.0
Ø35.0 250.0 Ø32.0 210.0 Ø25.0 250.0
MVS-010/02 3R 0.37 0.5 269 222 217 249 273 113 113 140 145 15.60 10.40 12.00 10 9
MVS-010/03 3R 0.55 0.75 287 242 232 267 291 113 113 140 145 16.30 11.10 12.70 11 10
MVS-010/04 3R 0.75 1.0 305 267 252 285 309 113 113 140 145 17.00 11.80 13.40 12 11
MVS-010/05 3R 1.1 1.5 323 284 264 303 327 118 118 160 145 17.70 12.50 14.10 16 15
MVS-010/06 3R 1.1 1.5 341 284 264 321 345 118 118 160 145 18.40 13.20 15.70 16 15
MVS-010/07 3R 1.5 2.0 359 294 295 339 363 136 136 187 163 19.10 13.90 15.50 20 20
MVS-010/08 3R 2.2 3.0 377 320 295 357 381 136 136 187 163 19.80 14.60 16.20 21.50 20
MVS-010/09 3R 2.2 3.0 395 320 295 375 399 136 136 187 163 20.60 15.40 17.00 21.50 20
MVS-010/10 3R 2.2 3.0 413 320 295 393 417 136 136 187 163 21.30 16.10 17.70 21.50 20
MVS-010/11 3R 2.2 3.0 431 320 295 411 435 136 136 187 163 22.00 16.80 18.40 21.50 20
MVS-010/12 3R 2.2 3.0 449 320 295 465 489 136 136 187 163 22.70 17.50 19.10 21.50 20
MVS-010/13 3R 3 4.0 485 340 320 483 507 136 136 187 163 23.60 19.00 20.60 23.0 21.50
MVS-010/15 3R 3 4.0 521 340 320 501 525 136 136 187 163 25.00 20.40 22.00 23.0 21.50
MVS-010/18 3R 4 5.5 575 - 354 555 579 - 136 187 163 27.10 22.50 23.60 - 26.00
NPSHR CURVE
H - (feet)
H - (m)
30
8
20
NPSHR
4
10
0 0
0 2 4 6 8 10 12 14 16 18 20
Q - (US GPM)
0 0.20 0.40 0.60 0.80 1.0 Q - (lps) 1.20
10
VERTICAL MULTISTAGE PUMPS
MV-10
NOMINAL FLOW : 10 GPM
260
H - (m)
H - (feet)
MV-010
60 Hz
800 MVS-010/18 3R
240 3450rpm
60
EFFICIENCY ( % )
220
EFF%
700
MVS-010/15 3R
200 40
600 MVS-010/13 3R
180
MVS-010/12 3R 20
160
500 MVS-010/11 3R
140 MVS-010/10 3R
MVS-010/09 3R
120 400
MVS-010/08 3R
100
MVS-010/07 3R
300
MVS-010/06 3R
80
MVS-010/05 3R
60 200
MVS-010/04 3R
40 MVS-010/03 3R
100 MVS-010/02 3R
20
0 0
0 2 4 6 8 10 12 14 16 18 20 22
Q - (US gpm)
Q - (lps)
0 0.2 0.4 0.6 0.8 1.0 1.2
Note : Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. Last digit '3' stands for 3 phase.
The given performance is same for Type - C, S, N
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.
MV SERIES - 60 Hz 11
COMMITMENT | RELIABILITY | INNOVATION
MVC (ROUND FLANGE) MVS & N (PJE) MVS & N (ROUND FLANGE)
210.0
210.0
210.0
180.0
180.0
180.0
Ø13.0 X 4Nos Ø13 X 4Nos Ø13 X 4Nos
100.0 100.0 100.0
150.0 150.0 150.0
X X
X ØY
ØY ØY
L2
L2
L2
L4+L2
Z
L1+L2
Z
L3+L2
Z
154 Sq 154 Sq
154 Sq
(DIN)
PN 25 / DN 25 / 32 (DIN)
PN 25 / DN 25 / 32
L4
L1
L3
19 X 27 Ø42.40
(PJE) 19 X 27 Ø14.0 X 4Nos
PCD 85.0
105.0
89.0
100.0
89.0
75.0
75.0
50.0
Ø35.0 250.0 Ø32.0 210.0 Ø25.0 250.0
NPSHR CURVE
H - (feet)
H - (m)
5 16
4
12
3 NPSHR
8
2
1 4
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24
Q - (US GPM)
Q - (lps)
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
0 1 2 3 4 5
Q - (m³/h)
12
VERTICAL MULTISTAGE PUMPS
MV-15
NOMINAL FLOW : 15 GPM
H - (m)
H - (feet)
260
MV-015
60 Hz
800 3450rpm
240 MVS-015/25 3R
220 MVS-015/23 3R
700 80
MVS-015/21 3R
EFFICIENCY ( % )
200 EFF %
60
MVS-015/19 3R
600 40
180
20
MVS-015/17 3R
160
500 MVS-015/15 3R 0
140
MVS-015/13 3R
120 400
MVS-015/12 3R
MVS-015/11 3R
100 MVS-015/10 3R
300
MVS-015/09 3R
80 MVS-015/08 3R
MVS-015/07 3R
60 200 MVS-015/06 3R
MVS-015/05 3R
40 MVS-015/04 3R
MVS-015/03 3R
100
20 MVS-015/02 3R
0 0
0 2 4 6 8 10 12 14 16 18 20 22 24
Q - (US gpm)
Q - (lps)
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
Note : Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. Last digit '3' stands for 3 phase.
The given performance is same for Type - C, S, N
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.
MV SERIES - 60 Hz 13
COMMITMENT | RELIABILITY | INNOVATION
MVC (ROUND FLANGE) MVS & N (PJE) MVS & N (ROUND FLANGE)
210.0
210.0
210.0
180.0
180.0
180.0
Ø13.0 X 4Nos Ø13 X 4Nos Ø13 X 4Nos
100.0 100.0 100.0
150.0 150.0 150.0
X X
X ØY
ØY ØY
L2
L2
L2
L4+L2
Z
L1+L2
Z
L3+L2
Z
154 Sq 154 Sq
154 Sq
(DIN)
PN 25 / DN 25 / 32 (DIN)
PN 25 / DN 25 / 32
L4
L1
L3
19 X 27 Ø42.40
(PJE) 19 X 27 Ø14.0 X 4Nos
PCD 85.0
105.0
89.0
100.0
89.0
75.0
75.0
50.0
Ø35.0 250.0 Ø32.0 210.0 Ø32.0 250.0
MVS-020/01 3R 0.37 0.5 287 222 217 267 291 113 113 140 145 18.90 13.70 15.30 10 9
MVS-020/02 3R 0.75 1.0 287 267 252 294 318 113 113 140 145 19.60 14.40 16.00 12 11
MVS-020/03 3R 0.75 1.0 314 267 252 321 345 113 113 140 145 20.30 15.10 16.70 12 11
MVS-020/04 3R 1.5 2.0 341 295 295 348 372 118 118 187 163 21.00 15.80 17.40 20 20
MVS-020/05 3R 2.2 3.0 368 320 295 375 399 136 118 187 163 21.70 16.50 18.10 21.5 20
MVS-020/06 3R 2.2 3.0 395 320 295 402 426 136 136 187 163 22.40 17.20 18.80 21.5 20
MVS-020/07 3R 3 4.0 440 340 320 447 471 136 136 187 163 23.10 18.50 20.10 23 21.5
MVS-020/08 3R 3 4.0 467 340 320 474 498 136 136 187 163 23.80 19.20 20.80 23 21.5
MVS-020/10 3R 4 5.5 521 - 354 528 552 - 136 187 163 25.10 20.50 22.10 - 26.00
MVS-020/12 3R 4 5.5 575 - 354 582 606 - 136 187 163 26.40 21.80 23.40 - 26.00
MVS-020/14 3R 5.5 7.5 629 - 385 636 660 - 204 257 197 27.10 22.50 24.10 - 70.50
MVS-020/16 3R 5.5 7.5 683 - 385 690 714 - 204 257 197 29.00 24.40 26.00 - 70.50
NPSHR CURVE
3 10
H - (feet)
H - (m)
8
2
6
NPSHR
4
1
2
0 0
0 5 10 15 20 25 30 35 Q - (US gpm)
0 0.5 1.0 1.5 2.0 Q - (lps)
0 1 2 3 4 5 6 7 8 9
Q - (m³/h)
14
VERTICAL MULTISTAGE PUMPS
MV-20
NOMINAL FLOW : 20 GPM
H - (feet)
260
H - (m)
MV-020
60Hz
800
3450rpm
EFFICIENCY ( % )
240
MVS-020/16 3R
220
700
MVS-020/14 3R
200 EFF% 60
600
180
MVS-020/12 3R
40
160
500
MVS-020/10 3R
140 20
MVS-020/07 3R
100
300 MVS-020/06 3R
80
MVS-020/05 3R
60 200 MVS-020/04 3R
MVS-020/03 3R
40
100 MVS-020/02 3R
20
MVS-020/01 3R
0 0
0 5 10 15 20 25 30 35 Q - (US GPM)
Q - (lps)
0 0.4 0.8 1.2 1.6 2 2.4
0 1 2 3 4 5 6 7 8 Q - (m³/h)
Note : Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. Last digit '3' stands for 3 phase.
The given performance is same for Type - C, S, N
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.
MV SERIES - 60 Hz 15
COMMITMENT | RELIABILITY | INNOVATION
MVC (ROUND FLANGE) MVS & N (PJE) MVS & N (ROUND FLANGE)
210.0
210.0
210.0
180.0
180.0
180.0
Ø13.0 X 4Nos Ø13 X 4Nos Ø13 X 4Nos
100.0 100.0 100.0
150.0 150.0 150.0
X X
X ØY
ØY ØY
L2
L2
L2
L4+L2
Z
L1+L2
Z
L3+L2
Z
154 Sq 154 Sq
154 Sq
(DIN)
PN 25 / DN 25 / 32 (DIN)
PN 25 / DN 25 / 32
L4
L1
L3
19 X 27 Ø42.40
(PJE) 19 X 27 Ø14.0 X 4Nos
PCD 85.0
105.0
89.0
100.0
89.0
75.0
75.0
50.0
Ø35.0 250.0 Ø32.0 210.0 Ø32.0 250.0
NPSHR CURVE
H - (feet)
H - (m)
5 16
4
12
3 NPSHR
8
2
1 4
0 0
0 5 10 15 20 25 30 35 40
Q - (US GPM)
Q - (lps)
0 0.4 0.8 1.2 1.6 2.0 2.4
0 1 2 3 4 5 6 7 8 9
Q - (m³/h)
16
VERTICAL MULTISTAGE PUMPS
MV-25
NOMINAL FLOW : 25 GPM
260
H - (m)
H - (feet)
MV-025
60Hz
800
240 MVS-025/24 3R 3450rpm
MVS-025/22 3R
220
700 80
EFF %
MVS-025/20 3R
EFFICIENCY ( % )
200 60
600 MVS-025/18 3R 40
180
20
160 MVS-025/16 3R
500 MVS-025/15 3R 0
140 MVS-025/14 3R
MVS-025/13 3R
MVS-025/11 3R
MVS-025/10 3R
100
300 MVS-025/09 3R
80 MVS-025/08 3R
MVS-025/07 3R
200 MVS-025/06 3R
60
MVS-025/05 3R
40 MVS-025/04 3R
100 MVS-025/03 3R
20 MVS-025/02 3R
0 0
0 5 10 15 20 25 30 35 Q - (US GPM)
Q - (lps)
0 0.4 0.8 1.2 1.6 2 2.4
0 1 2 3 4 5 6 7 8 Q - (m³/h)
Note : Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. Last digit '3' stands for 3 phase.
The given performance is same for Type - C, S, N
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.
MV SERIES - 60 Hz 17
COMMITMENT | RELIABILITY | INNOVATION
MVC (ROUND FLANGE) MVS & N (PJE) MVS & N (ROUND FLANGE)
215.0
265.0
215.0
265.0
215.0
265.0
Ø13 X 4Nos Ø13 X 4Nos Ø13 X 4Nos
130.0 130.0 130.0
175.0 175.0 175.0
X X X
ØY ØY ØY
L2
L2
L2
(DIN)
L3+L2
L4+L2
(DIN)
Z
Z
L1+L2
PN 25 / DN 40 (PJE) PN 25 / DN 40
195Sq 195 Sq 195 Sq
L3
L4
PCD 110.0 PCD 110.0
Ø60.30
80.0
80.0
80.0
MVS-040/01 3R 0.75 1.0 347 267 252 353 353 113 113 140 145 32.50 27.50 28.50 12.00 11.00
MVS-040/02 3R 1.5 2.0 379 294 295 385 385 136 136 187 163 33.50 28.50 29.50 20.00 20.00
MVS-040/03 3R 2.2 3.0 411 320 295 417 417 136 136 187 163 34.50 29.50 30.50 21.50 20.00
MVS-040/04 3R 3.0 4.0 454 340 320 460 460 136 136 187 163 35.50 30.50 31.50 23.00 21.50
MVS-040/05 3R 3.0 4.0 486 340 320 492 492 136 136 187 163 36.50 31.50 32.50 23.00 21.50
MVS-040/06 3R 4.0 5.5 518 - 354 524 524 - 136 187 163 37.50 32.50 33.50 - 26.00
MVS-040/08 3R 5.5 7.5 582 - 385 588 588 - 204 257 197 39.50 34.50 35.50 - 70.50
MVS-040/10 3R 5.5 7.5 656 - 385 662 662 - 204 257 197 41.50 36.50 37.50 - 70.50
MVS-040/12 3R 7.5 10 720 - 424 726 726 - 204 257 197 43.50 38.50 39.50 - 71.50
MVS-040/14 3R 7.5 10 784 - 424 790 790 - 204 257 197 49.50 44.50 45.50 - 71.50
NPSHR CURVE
12
H - (feet)
H - (m)
3
8
2
NPSHR
4
1
0 0
0 10 20 30 40 50 60
Q - (US GPM)
Q - (lps)
0 1 2 3 4
0 2 4 6 8 10 12 14
Q - (m³/h)
EFFICIENCY ( % )
H - (feet)
MV-040
H - (m)
280 60Hz
900
3450rpm
260
800 EFF % 60
240
40
220 MVS-040/14 3R
700 20
200 0
MVS-040/12 3R
180 600
160 MVS-040/10 3R
500
140
MVS-040/08 3R
120 400
100
MVS-040/06 3R
300
80 MVS-040/05 3R
MVS-040/04 3R
60 200
MVS-040/03 3R
40 MVS-040/02 3R
100
20 MVS-040/01 3R
0 0
0 10 20 30 40 50 60
Q - (US GPM)
Q - (lps)
0 1 2 3 4
0 2 4 6 8 10 12 Q - (m³/h)
Note : Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. Last digit '3'' stands for 3 phase.
The given performance is same for Type - C, S, N
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.
MV SERIES - 60 Hz 19
COMMITMENT | RELIABILITY | INNOVATION
215.0
265.0
215.0
265.0
Ø13 X 4Nos Ø13 X 4Nos
130.0 130.0
175.0 175.0
X X
ØY ØY
L2
L2
(DIN) (DIN)
L3+L2
Z
Z
PN 25 / DN 50
L1+L2
PN 25 / DN 50 195Sq 195 Sq
L3
PCD 125.0 PCD 125.0
90.0
90.0
MVS-080/03 3R 5.5 7.5 477 473 - 385 - 204 257 197 44.0 39.0 41.30
MVS-080/04 3R 7.5 10.0 522 518 - 424 - 204 257 197 45.0 40.0 47.60
MVS-080/05 3R 7.5 10.0 567 563 - 424 - 204 257 197 46.0 41.0 47.60
MVS-080/06 3R 11.0 15.0 612 608 - 495 - 223 312 225 47.50 42.50 110.0
MVS-080/07 3R 11.0 15.0 657 653 - 495 - 223 312 225 48.50 43.50 110.0
MVS-080/08 3R 15.0 20.0 702 698 - 495 - 223 312 225 49.50 44.50 110.0
NPSHR CURVE
H - (feet)
10
H - (m)
30
8
6 20
NPSHR
4
10
2
0 0
0 20 40 60 80 100 Q - (US gpm)
Q - (lps)
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
0 4 8 12 16 20 24
Q - (m³/h)
20
VERTICAL MULTISTAGE PUMPS
MV-80
NOMINAL FLOW : 80 GPM
H - (m)
H - (feet)
MV-080
220 700
60Hz
3450rpm
200
650
180 600
80
EFF%
550
160 MVS-080/08 3R
500 60
140 MVS-080/07 3R
450
40
350 MVS-080/05 3R 20
100
300
MVS-080/04 3R
80
250
MVS-080/03 3R
60 200
150
40
100
20
50
0 0
0 20 40 60 80 100 Q - (US GPM)
Q - (lps)
0 1.0 2.0 3.0 4.0 5.0 6.0 7.0
0 4 8 12 16 20 24 Q - (m³/h)
MVS-080/03 3R 5.5 7.5 208 203 197 188.5 174.5 147.5 100
TOTAL MANOMETRIC HEAD IN FEET
MVS-080/04 3R 7.5 10.0 274.5 270.5 265 254 231 187 160
MVS-080/05 3R 7.5 10.0 337.5 333.5 327.5 319 302.5 265 225
MVS-080/06 3R 11.0 15.0 393 387.5 374 348 305 242 208.5
MVS-080/07 3R 11.0 15.0 457 449.5 433 404 352.5 278.5 239
MVS-080/08 3R 15.0 20.0 525 518 500 466.5 410 327 281.5
Note : Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. Last digit '3' stands for 3 phase.
The given performance is same for Type - C, S, N
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.
MV SERIES - 60 Hz 21
COMMITMENT | RELIABILITY | INNOVATION
X X
Y Y
L2
L2
Z
Z
(DIN)
(DIN) PN16 - 25 - 40 / DN65
PN16 - 25 - 40 / DN65
L1
L1
Ø18.0 X 8Nos Ø18.0 X 8Nos
PCD 145.0 PCD 145.0
Ø185.0
Ø145.0
Ø185.0
Ø145.0
Ø74.0
Ø74.0
105.0
105.0
NPSHR CURVE
10
30
H - (feet)
H - (m)
8 25
6 20
15
4
10
2
NPSHR
5
0 0
0 40 80 120 160 200
Q - (US GPM)
0 6 8 10 Q - (lps)
2 4 12
0 10 20 30 40 Q - (m³/h)
22
VERTICAL MULTISTAGE PUMPS
MV-160
NOMINAL FLOW : 160 GPM
1000
H - (feet)
H - (m)
300 MV-160
MVS-160/11 3RB 60Hz
MVS-160/10 3R
3450 rpm
900
MVS-160/10 3RB
80
MVS-160/09 3R
EFFICIENCY ( % )
250
800 60
MVS-160/09 3RB
MVS-160/08 3R 40
200 0
MVS-160/07 3R
MVS-160/06 3R
MVS-160/06 3RB
150 500
MVS-160/05 3R
MVS-160/05 3RB
400
MVS-160/04 3R
300
MVS-160/03 3R
MVS-160/03 3RB
200
MVS-160/02 3R
50 MVS-160/02 3RA
MVS-160/02 3RB
100
MVS-160/01 3R
MVS-160/01 3RA
0 0
0 40 80 120 160 200
Q - (US GPM)
Q - (lps)
0 2 4 6 8 10 12 13
0 10 20 30 40 Q - (m³/h)
Note : Letter 'R' stands for Round Flange and it will be replaced with 'P' for PJE connection. Last digit '3' stands for 3 phase, 'A' stands for Trimmed impeller & 'B' stands
for extra trimmed impeller.
The given performance is same for Type - C, S, N
In view of the continuous developments the Information / Descriptions / Specifications / Illustrations are subject to change without notice.
MV SERIES - 60 Hz 23
COMMITMENT | RELIABILITY | INNOVATION
B O O S T E R S Y S T E M C O N T R O L
Booster controllers and control system are used to ensure uninterrupted water supply with constant pressure.
These control systems are imperative to control single or multiple pump booster systems.
C.R.I. MV Series pumps are compatible for different types of controllers such as step controllers (Relay logic) PLC
(Programmable Logic Controllers) and VFD (Variable Frequency Drive) with PID (Proportional integrated
Derivative) controlers. These controllers are suitable for both 50 & 60 Hz operations. Based on the number of
pumps and motor power used in the booster system controllers can be designed / selected suitably. These
control systems will indicate all the electrical parameters besides pressure and flow of each pump installed in the
PID control systems are available with Auto / Manual mode and are incorporated with inverter and LCD display.
Other equipments such as pressure transmitter and dry run monitor are connected to the control systems. In case
of any pump failure while operating multiple pumps the controller will skip the failed pump. The controller will
record all data of the control system and sense and display the nature of faults or abnormalities, if any.
These controllers are also available with automatic pump changeover mechanism which ensures evenly
24
VERTICAL MULTISTAGE PUMPS