You are on page 1of 2

Flashback Arrestor according to EN 730-1, ISO 5175

Model: DG91 N

Pos: 1 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Absichern FD und ES @ 0\mod_1188811405744_61.doc @ 6753

For protection of Cylinder-Regulators and Tapping


Points.
Pos: 2 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Produktbeschreibung DG91N @ 0\mod_1189163494249_61.doc @ 7400

Always used where high flow rates with low pressure drops
are necessary for an undisturbed production process. The
high flow rates guarantee a long product life with the highest
level of safety and functionality.

Pos: 3 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Sicherheitselemente NV, FA, TV @ 0\mod_1188812629962_61.doc @ 6771

Safety elements:
• Gas non-return valve NV
• Flame arrestor FA
• Thermal cut-off valve TV

Dust filter promotes long shelf-life


Pos: 4 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Gewindeanschlüsse 02 @ 0\mod_1188976637482_61.doc @ 7183

Threads:
In accordance with EN 560, ISO 3253 or country specific connections
Fuel Gas: G3/8“LH, M16X1.5LH, UNF9/16“-18LH, UNF5/8“-18LH, 1/4“-NPT
Oxygen/Compressed Air: G1/4“RH, G3/8“RH, M16X1.5RH, UNF9/16“-18RH, UNF5/8“-18RH, 1/4“-NPT
For additional connections please contact IBEDA
Pos: 5 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Gasarten Sicherungen @ 1\mod_1193309206207_61.doc @ 11473

Gas-Types:
Acetylene (A), Town Gas (C), Ethylene (E), Hydrogen (H), Natural Gas (Methane) (M), Propane (P), MPS Methyl-
acetylen-Propadien-Mixture (Y), Oxygen (O), Compressed Air (D)
Pos: 6 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Betriebsdrücke 03 @ 0\mod_1189063355643_61.doc @ 7253

Working pressure:
A 1.5 bar ; H 4.0 bar ; CEMPY 5.0 bar ; DO 15.0 bar
Pos: 7 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Maße und Gewicht DG91N @ 0\mod_1189163584327_61.doc @ 7409

Measure and weight:


diameter: 32,00 mm
length: 107,00 mm
weight: 375,00 g
Pos: 8 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Wartung Sicherungen @ 0\mod_1188917982996_61.doc @ 7130

Maintenance:
The safety devices are to be tested by a qualified and authorised person at regular intervals according to country
specific regulations. They are to be tested for gas tightness and gas return at least once a year.
Pos: 9 />> VERTRIEB <</DATENBLÄTTER/Gassicherheitstechnik/Ausführungen @ 0\mod_1188918091230_61.doc @ 7139

Design:
Other materials and surface finishing on request.
===== Ende der Stückliste =====