You are on page 1of 2

0197

BS330 Disposable Plasma Bilirubin HA330-II Disposable


Product Parameter
Adsorption Column Hemoperfusion Cartridge

Loading capacity(ml) 330±3 330±3 Double Plasma Molecular Adsorption System


Volumn(ml) 160±5 185±5
A recommended artificial liver system in CMA Liver Failure Guidelines[1]

DPMAS
Adsorbent material Styrene Divinylbenzene Copolymers Styrene Divinylbenzene Copolymers

Housing material Polycarbonate Polycarbonate

Sterilization method Moist Heat Sterilization Irradiation Sterilization

Unit Package 280mm(L)×105mm(W)×108mm(H) 0.90kg 280mm(L)×105mm(W)×108mm(H) 0.90kg

Jafron — the largest manufacturer of adsorption columns in the world

HA130 HA230 HA280 HA330/HA380 HA330-Ⅱ


ESRD Acute Poisoning Immune Disease Critical Disease Hepatic Failure

BS330 DNA230
Bilirubin Adsorption SLE

Comprehensive Solution
for Hepatopathy

DPMAS-02-01-Mar.-2018

Jafron High-Tech Park CE ISO 9001 ISO 13485

JAFRON BIOMEDICAL CO., LTD.


Address: No. 98 Technology Six Road, High-tech Zone, Zhuhai, Guangdong, China
Tel: 0086-756-3619986 0086-756-3619196
E-mail: overseatrade@jafron.com
Post Code: 519080
Website: en.jafron.com
Double Plasma Molecular Adsorption System (DPMAS) is a comprehensive Clinical Efficacy Compatible with Multiple Machines
solution for liver disease. It specifically adsorbs bilirubin, effectively clears inflammatory
(ng/ml)
mediators, eases inflammation and immune responses as well as considerably relieves the
Before treatment
clinical symptoms and eventually improves the long-term prognosis of patients. 30
After treatment
25
38.6%
20
34.99%
15

10

Liver Failure & Complications 5


(e.g. hepatic encephalopathy) Pre & Post Liver Transplant
0
TNF-α Total bilirubin(TB)

Conclusion: DPMAS efficiently removes bilirubin


[4]
while clearing inflammatory mediators.

Virus Hepatitis Jaundice


Optional Treatment for Liver Disease
Non-virus Hepatitis
BS330 plasma adsorption
Anticoagulant Plasma Pump

DPMAS — Efficient Liver Support System Blood Pump


For hyperbilirubinemia and hyperbileacidemia

BS330
Plasma separator
Effectively improve jaundice symptom
Anticoagulant
Plasma Pump

Blood Pump

Plasma Adsorption
Plasma separator

HA330-Ⅱdirect blood adsorption


BS330 HA330-II Anticoagulant

Blood Pump
For early hepatitis
Extensively remove toxins induced by liver disorder
such as inflammatory mediators, ammonia, phenol
BS330+HA330-II Plasma adsorption HA330-II mercaptan, etc.

BS330 specifically adsorbs bilirubin, bile acid Direct Blood Perfusion


HA330-II broad-spectrum adsorbs toxins such as
and endotoxin.[2] inflammatory mediators, ammonia, phenol mercaptan, etc.[3]
Reference:
[1] Liver Failure and Artificial Liver Group, Society of Infectious Diseases, Chinese Medical Association Guidelines for Non-bioartificial Liver Support System in
Treatment of Liver Failure(2016 Edition) Chin J Clin Infect Dis, April 2016, Vol.9, No.2.
[2] Jiajia Chen, Jianrong Huang, Yuemei Chen, et al. A clinical study on the treatment of severe hepatitis by a combined artificial liver hepato-gastroenterology
2012; 59(119): Ahead of print.
[3] Maoqin Li, Zhidong Wang, Yining Wang, et al. Part of plasmapheresis with plasma filtration adsorption combined with continuous hemodiafiltration in
BS330 Disposable Plasma Anion-exchange resin HA330-II Disposable Neutral-macroporous resin
the treatment of severe acute liver failure. Experimental and Therapeutic Medicine 2016; 1
Bilirubin Adsorption Column Hemoperfusion Cartridge [4] Qi Xia*, Xiahong Dai*, Jianrong Huang et al. A single-center experience of non-bioartificial liver support systems among Chinese patients with liver failure
Int J Artif Organs 2014; 37 (6): 442-454.2(8): 2582-2584.