You are on page 1of 8

DATA SHEET FOR AHU

SL. NO. Description UNITS


A GENERAL INFORMATION No's
1 Make
2 Model
3 Type
4 Outdoor Design condition
5 Summer DBT/WBT deg.C
6 Indoor Design Condition deg.C/ RH
7 Type of duty operation hours
8 Total cooling capacity-Required TR
9 Total Volume Flow Rate cfm
B FILTERS
Stages of filtration
First Stage
1
Second Stage
2
Third Stage ( Only Critical Areas)

3
Filter Material

4
Filter casing material

5
6 Size & Thick & Qty. mm
7 Pressure drop, initial mm of WG
8 Pressure drop, final mm of WG
9 Total cross section filter area m2
10 Total Air Flow m3/hr
11 Air velocity M/sec
C System definition

1 System ADP deg.C

Available Entering Chilled water


2 Temperature deg.C

Available Leaving Chilled water


3 Temperature deg.C
4 AHU COIL air inletlet Conditions
EDBT deg.C
EWBT deg.C
LDBT deg.C
LWBT deg.C
E COOLING COIL
1 Nos. of cooling coil bays No's
2 Nos. of coil per bay No's
3 Finned length mm
4 Fin Height: mm
5 Fin depth: mm

6 Number of rows No's


7 Number of circuits No's
8 Total coil face area per bay m2
9 Total surface area m2
10 Header diameter: mm
11 Tubes material:
12 Tubes wall thickness mm
13 Tube diameter mm
14 Fin material
15 Fin thickness mm
16 Fin Spacing FPI
17 Type of fins
18 By pass factor
19 Tube turbulator vane
20 Inlet water temperature deg.C
21 Leaving water temperature deg.C
22 Mass water flow rate GPM
23 Water velocity inside tube m / sec
24 Pressure drop on water side max. 5 m of WG
25 Coil inlet /outlet nozzle size mm
26 Coil face Velocity FPM
27 Pressure drop on Air side mm of WG

F BLOWER
AHU Fan should be Plug Fan
( Backward curved or Aerofoil )
1 Type
2 Make
3 Certification YES//NO
4 Model No.
5 Volume flow rate CFM
6 Outlet Velocity FPM
7 Wheel diameter mm

8 External static pressure at AHU discharge mm of WG


9 Velocity pressure mm of WG
10 Total Pressure mm of WG
11 Rated Speed RPM
12 Critical Speed RPM
13 Static efficiency %
14 Mechanical Efficiency %
15 Absorbed power BkW
16 Noise Level dB ( A )
17 Vibration Level Microns

18 Painting Microns

G BLOWER MOTOR
1 Type

2 Frame Size
3 Supply by
4 Installed power kW
5 Maximum absorbed power
6 Maximum speed RPM
7 Voltage
8 Frequency Hz
9 No. of Phases No's
10 Vibration isolators 1 set
11 Bearing for blower 1 set

12 Inlet guard for blower 1 set

H CASING
Inner skin
1 mm
Outer skin
2 mm
Frame work
3
4 Base frame
5 Painting
6 Thermal insulation bet. Panels Check for Pressure.
7 Drain pan
8 continuous rubber sealing
9 Access window mm X mm
10 Matching Flanges for plenum
I ACCESSORIES
1 Flexible canvass for Blower 1 per fan
2 Vibration isolators 1 per fan
3 Inlet guard for blower 1 per fan
4 Electric control panel - Local 1 per fan
5 Starter 1 per fan
J DIMENSIONAL DETAILS(Max)
1 Length mm
2 Width mm
3 Height mm
4 Weight kg
K ANALYSIS
1 Sp. Power consumption kW/1000cfm
2 Sp. Cross section sq.ft/1000cfm
OR AHU
Consultant Specs Vendor Specs

22.77/55
24
As per the list
As per the list

10 micron with 90 %
efficiency

3micron with 99 %
efficiancy

Terminal 0.3
micron/HEPA
filters(Ductmounted)

Washable/synthetic/non-
woven fiber media for
10 micron and 5 micron
filters.

MS powder coated with


SS fastners( if flanged
type offered)
Vender to specify
Vender to specify
Vender to specify
Vender to specify
As per the list
1.7

10

13

Refer AHU on/off coil


temp sheet
Refer AHU on/off coil
temp sheet

Vender to specify
Vender to specify
Vender to specify
Vender to specify
Vender to specify

6 Row deep Cooling Coil


Vender to specify
Vender to specify
Vender to specify
Vender to specify
Copper
Vender to specify
Vender to specify
Aluminium
Vender to specify
Vender to specify
Vender to specify
Vender to specify
Vender to specify
6
13
1.9GPM / TR
Vender to specify
Vender to specify
Vender to specify
330
Vender to specify

Shall be designed for


VFD application

Vender to specify
Vender to specify
AMCA certification
Vender to specify
As per the list
Vender to specify
Vender to specify

Vender to specify
Vender to specify
100
Vender to specify
Vender to specify
Vender to specify
Vender to specify
Vender to specify
below 50 db(A) at 1 m
below 60 micron

below 150 micron Zinc


coating

Shall be designed for


Variable frequency drive
application
Vender to specify
Vender to specify
Vender to specify
Vender to specify
Vender to specify
1440
415+15%/-15%
50 +3% -3%
3
Vender to specify
Vender to specify
yes

should be Thermal
Break

Not less than 0.63


Aluminium

Not less than 0.63


Aluminium

Extruded Aluminium
Sections
Al
Powder coated
50 mm,PUF
Insulated
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Vender to specify
Vender to specify
Vender to specify
Vender to specify

Vender to specify
Vender to specify

You might also like