You are on page 1of 2

Shape and Dimension Tolerance

of H - Beam and Wide Flange


According to JIS G.3192 unit :mm
Dimension Tolerance Remarks

Width ( B ) ± 3.0

Nominal height under 400 ± 3.0


Height (H) 400 to 600 excl. ± 4.0
600 to over ± 5.0
Under 16 ± 1.0
16 to 25 excl. ± 1.5
Web ( t1 )
25 to 40 excl. ± 2.0
Thickness

40 and over ± 2.5


Under 16 ± 1.5
16 to 25 excl. ± 2.0
Flange ( t2 )
25 to 40 excl. ± 2.5
40 and over ± 3.0
+ 40
7 m or under
-0

Add 5 mm to the above plus


Length
side tolerance for every
over 7 m
increase of 1 m of length ir
its fraction

1.2% or less of flange B.


The minimum value of
300 or less in nominal heigth
tolerance, however, shall be
2.0 mm.
Out - of - Square (T)
1.5% or less of flange B.
The minimum value of
Over 300 in nominal heigth
tolerance, however, shall be
2.0 mm.
300 or under in nominal depth 0.20 % or under of length to be applied to warpage upward
Warpage
Over 300 in nominal depth 0.10 % or under of length and downward, to the right and

300 or less in nominal height ± 3.0


Eccentricity (S)
Over 300 in nominal height ± 4.5

Under 400 in nominal depth 2.0


Concavity of Web ( W ) 400 or over to and excl. 600 2.5
600 or over 3.0

16 % or under of less of the


flange B or height H. The
Squareness of cut section ( e )
minimum value of tolerance,
however, shall be 3.0 mm.

Minimum Fillet Weld Sizes

Base - Metal Thickness (T)1 Minimum Size of Fillet Weld2


in mm in mm
T ≤ 1/4 T≤6 1/8 (Note 3) 3 (Note 3)

1/4 < T ≤ 1/2 6 < T ≤ 12 3/16 5


1/2 < T ≤ 3/4 12 < T ≤ 20 1/4 6
3/4 < T 20 < T 5/16 8

QUALITY CONTROL DEPT.


Shape and Dimensional
Tolerance of Angles, I - beam and Channels
According to JIS G.3192 unit : mm

Dimension Tolerance Remark

Leg Under 50 ± 1.5


length 50 or over to and excl. 100 ± 2.0
(A or B) 100 or over to and excl. 200 ± 3.0
200 or over ± 4.0
Under 100 ± 1.5
Depth 100 or over to and excl. 200 ± 2.0
(H) 200 or over to and excl. 400 ± 3.0
400 or over ± 4.0

For leg length Under 6.3 ± 0.6


A ( A for T 6.3 or over to
± 0.7
section ) : and excl. 10
Thick - under 130 10 or over to
± 0.8
ness in dept and excl. 16
(t t1t2) 16 or over ± 1.0
For leg length Under 6.3 ± 0.7
A ( A for T 6.3 or over to
± 0.8
section ) : and excl. 10
130 or over 10 or over to
± 1.0
p
in depth and excl. 16
16 or over to
± 1.2
and excl. 25
25 or over ± 1.5
+ 40
7 m or under
0
Add 5 mm to the
plus side tolerance
given in the
Length
above column for
Over 7 m
every 1 m increase
in length or its
fraction

2.0 % or under
Out - of I section of width B
square
(T) Sections excluding 2.5 % or under of
I section width of flange B
( or leg length )

0.20 % or under
I and T section of width B
To be applied to bend such as
Bend
Sections excluding 0.30 % or under sweep and camber.
I and T section of width B

QUALITY CONTROL DEPT.