You are on page 1of 11

]~´p0-mk,Calculate And Selection Result

1.Project Parameter

Project Name: 001_EMBAIXADA_SYS01


Nation: Brazil
Location: Brasilia
Address: Embaixada da Itália
Name:
Job Title:
Outdoor barometric pressure in summer(Pa): 89000
Outdoor mean air velocity in summer(m/s): 7.42
Summer Outdoor Dry-bulb: 32.1
Summer Outdoor Wet-bulb: 22.2
Winter Outdoor Dry-bulb: 7
Winter Outdoor Wet-bulb: 6

2.Material List

Model Qty Description


4TVH0192BK000AA 1 TVR II HP Outdoor 380-415V
3N 60Hz
4TVH0096BK000AA 1 TVR II HP Outdoor 380-415V
3N 60Hz
4TVH0096BK000AA 1 TVR II HP Outdoor 380-415V
3N 60Hz
4TVW0009B1000AA 6 High Wall
4TVA0024DF000AA 1 DC High ESP Ducted
4TVB0012B1000AA 3 4-way Cassette compact
4TVW0015B1000AA 3 High Wall
4TVB0015B1000AA 1 4-way Cassette compact
4TVW0024B1000AA 1 High Wall R
TRDK225HP 3 Distributor
TRDK112HP 6 Distributor
TRDK056HP 5 Distributor
TODK002HP 1 Distributor
Ø31.8 55.5m Copper Pipe
Ø19.1 45.0m Copper Pipe
Ø25.4 20.0m Copper Pipe
Ø12.7 81.0m Copper Pipe
Ø22.2 16.0m Copper Pipe
Ø15.9 31.5m Copper Pipe
Ø6.35 52.0m Copper Pipe
Ø9.53 14.0m Copper Pipe
Individual controllers (wired or wireless) must be ordered separately. They are not included with
indoor units.

3.Sys01

3.1 Material List

Model Qty Description


4TVH0192BK000AA 1 TVR II HP Outdoor 380-415V
3N 60Hz
4TVH0096BK000AA 1 TVR II HP Outdoor 380-415V
3N 60Hz
4TVH0096BK000AA 1 TVR II HP Outdoor 380-415V
3N 60Hz
4TVW0009B1000AA 6 High Wall
4TVA0024DF000AA 1 DC High ESP Ducted
4TVB0012B1000AA 3 4-way Cassette compact
4TVW0015B1000AA 3 High Wall
4TVB0015B1000AA 1 4-way Cassette compact
4TVW0024B1000AA 1 High Wall R
TRDK225HP 3 Distributor
TRDK112HP 6 Distributor
TRDK056HP 5 Distributor
TODK002HP 1 Distributor
Ø31.8 55.5m Copper Pipe
Ø19.1 45.0m Copper Pipe
Ø25.4 20.0m Copper Pipe
Ø12.7 81.0m Copper Pipe
Ø22.2 16.0m Copper Pipe
Ø15.9 31.5m Copper Pipe
Ø6.35 52.0m Copper Pipe
Ø9.53 14.0m Copper Pipe
3.2 Specifications

Room Description Model RTC ATC RTH ATH Air Flow Sound Dimension Weight Static Pressure Power Supply
kW kW kW kW m^3/h dBA mm kg Pa
45 Indoor Unit 4TVW0009B1000AA 2.8 2.65 3.2 3.075 557 35 915*210*290 12 0 220-240,60,1
1
05 Indoor Unit 4TVA0024DF000AA 7.1 6.63 8 7.336 1500 46 952*420*690 41 25 220-240,60,1
1
10 Indoor Unit 4TVW0009B1000AA 2.8 2.61 3.2 2.935 557 35 915*210*290 12 0 220-240,60,1
5
20 Indoor Unit 4TVB0012B1000AA 3.6 3.37 4 3.693 496 41.5 570*260*570 18 0 208-230,60,1
15 Indoor Unit 4TVW0009B1000AA 2.8 2.62 3.2 2.96 557 35 915*210*290 12 0 220-240,60,1
2
25 Indoor Unit 4TVW0009B1000AA 2.8 2.63 3.2 2.992 557 35 915*210*290 12 0 220-240,60,1
1
27 Indoor Unit 4TVB0012B1000AA 3.6 3.38 4 3.75 496 41.5 570*260*570 18 0 208-230,60,1
5
30 Indoor Unit 4TVW0015B1000AA 4.5 4.24 5 4.733 842 40 1070*210*315 15 0 220-240,60,1
3
17 Indoor Unit 4TVB0012B1000AA 3.6 3.38 4 3.752 496 41.5 570*260*570 18 0 208-230,60,1
6
35B Indoor Unit 4TVW0015B1000AA 4.5 4.24 5 4.758 842 40 1070*210*315 15 0 220-240,60,1
9
40 Indoor Unit 4TVW0009B1000AA 2.8 2.65 3.2 3.084 557 35 915*210*290 12 0 220-240,60,1
4
50 Indoor Unit 4TVB0015B1000AA 4.5 4.25 5 4.783 496 41.5 570*260*570 18 0 208-230,60,1
6
60 Indoor Unit 4TVW0009B1000AA 2.8 2.63 3.2 3.018 557 35 915*210*290 12 0 220-240,60,1
7
55 Indoor Unit 4TVW0024B1000AA 7.1 6.68 8 7.544 1190 45 1250*245*325 19.9 0 220-240,60,1
8
35A Indoor Unit 4TVW0015B1000AA 4.5 4.25 5 4.78 842 40 1070*210*315 15 0 220-240,60,1
5
Outdo Outdoor 4TVH0192BK000AA 59.8 57.6 67.2 67.34 15000 57 960*1615*765 490 N/A 380-3-60
or Unit +960*1615*76
5
The information provided by the software is for informational purposes needs to be verified with the IOM manual and that any discrepancy between the software
and IOM should be communicated in writing for further verification.
RTC: Required total cooling capacity
ATC: Available total cooling capacity
RTH: Required total heating capacity
ATH: Available total heating capacity
3.3 Pipe And Refrigerant Distributors

IU quantity 15/24
Combination Ratio 106.79%
Additional refrigerant charge 20.90kg
= 52.00(6.35) * 0.022 + 14.00(9.53) * 0.057 +
33.50(12.7) * 0.11 + 19.50(15.9) * 0.17 +
46.00(19.1) * 0.26
Total pipe length 162.5m/350m
Furthest Actual 84m/150m
Furthest equivalent 89m/175m
Drop height between IU and IU 2m/15m
After first branch length 43.5m/40.0(90.0)m
Drop height between IU and OU(Below OU) 3m/50m
Available Cooling Capacity 57.6 kW
Available Heating Capacity 67.34 kW
1 branch 0.5m Copper pipe.

Pipe
No Length Gas Pipe Liquid Pipe
(1) 45.0m Ø31.8 Ø19.1
(2) 2.5m Ø25.4 Ø12.7
(3) 2.0m Ø25.4 Ø12.7
(4) 3.0m Ø22.2 Ø12.7
(5) 6.0m Ø22.2 Ø12.7
(6) 3.5m Ø25.4 Ø15.9
(7) 3.0m Ø25.4 Ø12.7
(8) 3.5m Ø25.4 Ø12.7
(9) 2.5m Ø22.2 Ø12.7
(10) 3.0m Ø22.2 Ø12.7
(11) 1.5m Ø22.2 Ø12.7
(12) 1.5m Ø12.7 Ø6.35
(13) 8.0m Ø15.9 Ø9.53
(14) 8.0m Ø12.7 Ø6.35
(15) 4.5m Ø12.7 Ø6.35
(16) 6.5m Ø12.7 Ø6.35
(17) 1.0m Ø12.7 Ø6.35
(18) 3.0m Ø12.7 Ø6.35
(19) 3.0m Ø12.7 Ø6.35
(20) 3.5m Ø25.4 Ø15.9
(21) 6.0m Ø12.7 Ø6.35
(22) 6.5m Ø31.8 Ø15.9
(23) 3.0m Ø12.7 Ø6.35
(24) 1.5m Ø12.7 Ø6.35
(25) 1.5m Ø12.7 Ø6.35
(26) 6.0m Ø12.7 Ø6.35
(27) 6.0m Ø15.9 Ø9.53
(28) 4.0m Ø31.8 Ø15.9
(29) 6.5m Ø12.7 Ø6.35

Distributor
No Load kW Model
(1) 59.8 TRDK225HP
(2) 20 TRDK112HP
(3) 17.2 TRDK112HP
(4) 14.4 TRDK056HP
(5) 9.9 TRDK056HP
(6) 30.8 TRDK112HP
(7) 22.7 TRDK112HP
(8) 19.1 TRDK112HP
(9) 16.3 TRDK056HP
(10) 13.5 TRDK056HP
(11) 9.9 TRDK056HP
(12) 26.3 TRDK112HP
(13) 35.3 TRDK225HP
(14) 39.8 TRDK225HP
3.4 Drawing
TVR 60Hz R410A
57.6 kW

4TVH0192BK000AA

(1) (2) (3) (4) (5) 6.688 kW


Ø31.8,Ø19.1 Ø25.4,Ø12.7 Ø25.4,Ø12.7 Ø22.2,Ø12.7 Ø22.2,Ø12.7 Ø15.9,Ø9.53 4TVW0024B1000AA
55
TRDK225HP TRDK112HP TRDK112HP TRDK056HP TRDK056HP

2.637 kW
Ø12.7,Ø6.35 4TVW0009B1000AA
60

4.256 kW
Ø12.7,Ø6.35 4TVB0015B1000AA
50

2.651 kW
Ø12.7,Ø6.35 4TVW0009B1000AA
45

2.654 kW
Ø12.7,Ø6.35 4TVW0009B1000AA
40

(14) (13) (6) (12) (7) (8) (9) (10) (11) 6.631 kW
Ø31.8,Ø15.9 Ø31.8,Ø15.9 Ø25.4,Ø15.9 Ø25.4,Ø15.9 Ø25.4,Ø12.7 Ø25.4,Ø12.7 Ø22.2,Ø12.7 Ø22.2,Ø12.7 Ø22.2,Ø12.7 Ø15.9,Ø9.53 4TVA0024DF000AA
05
TRDK225HP TRDK225HP TRDK112HP TRDK112HP TRDK112HP TRDK112HP TRDK056HP TRDK056HP TRDK056HP

2.615 kW
Ø12.7,Ø6.35 4TVW0009B1000AA
10

3.37 kW
Ø12.7,Ø6.35 4TVB0012B1000AA
20

2.622 kW
Ø12.7,Ø6.35 4TVW0009B1000AA
15

2.631 kW
Ø12.7,Ø6.35 4TVW0009B1000AA
25

3.385 kW
Ø12.7,Ø6.35 4TVB0012B1000AA
27

3.386 kW
Ø12.7,Ø6.35 4TVB0012B1000AA
17

4.243 kW
Ø12.7,Ø6.35 4TVW0015B1000AA
30

4.249 kW
Ø12.7,Ø6.35 4TVW0015B1000AA
35B

4.255 kW
Ø12.7,Ø6.35 4TVW0015B1000AA
35A

The piping size may be different with the actual situation because of the software's illustration limitation, please confirm the piping size according to the installation manual before installation.
3.5 Optional controller
wire gauge 0.75 mm^2 up to 200m, for larger lengths use 1.1 mm^2

OU-1

PQE 0.75mm2*3
IU1
H1,H2,E

PQE 0.75mm2*3
IU2

PQE 0.75mm2*3
IU3

PQE 0.75mm2*3
IU4

PQE 0.75mm2*3
IU5

PQE 0.75mm2*3
IU6

PQE 0.75mm2*3
IU7

PQE 0.75mm2*3
IU8

PQE 0.75mm2*3
IU9

PQE 0.75mm2*3
IU10

PQE 0.75mm2*3
IU11

PQE 0.75mm2*3
IU12

PQE 0.75mm2*3
IU13

PQE 0.75mm2*3
IU14

PQE 0.75mm2*3
IU15