You are on page 1of 12

technical data

air conditioning systems


FTYN-FV1B

R-410A

Split
Sky Air
• Indoor Units • R-410A • FTYN-FV1B

TABLE OF CONTENTS
FTYN-FV1B

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
For indoor units only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3 Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . 5


Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4 Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

5 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Wiring diagram ....................................................... 8

6 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

• Split Sky Air • Indoor Units 1


• Indoor Units • R-410A • FTYN-FV1B

1 Features

t i y n k BU S 1 V r AFt o 0- i o 1N ld 4Y npT- RF•SI Flat front panel: its stylish appearance blends easily within any • Powerful mode can be selected for rapid cooling or heating
interior décor and is more easy to clean. • Auto-swing function ensures efficient air and temperature
• Lightweight and compact distribution.
• Titanium apatite photocatalytic air purification filter

optional 5 steps

standard 50 + 60 class

2 • Split Sky Air • Indoor Units


• Indoor Units • R-410A • FTYN-FV1B

2 Specifications

2-1 FOR INDOOR UNITS ONLY


Nominal input Cooling kW
FTYN50FV1B
0.034
FTYN60FV1B
0.04
3
(Indoor only) Heating kW 0.036 0.045

2-2 TECHNICAL SPECIFICATIONS FTYN50FV1B FTYN60FV1B


Casing Colour White 2
Dimensions Packing Height mm 337 337
Width mm 1147 1147
Depth mm 366 366
Unit Height mm 290 290
Width mm 1050 1050
Depth mm 238 238
Weight Unit kg 12 12
Packed Unit kg 17 17
Heat Dimensions Length mm 863 863
Exchanger Nr of Rows 2 2
Fin Pitch mm 1.4 1.4
Nr of Stages 16 16
Tube type Hi-XA (7)
Fin Type ML fin (Multi louver)
Fan Type Cross flow fan
Quantity 1 1
Air Flow Rate Cooling High m³/min 14.7 16.2
Medium m³/min 12.4 13.6
Low m³/min 10.3 11.4
Heating High m³/min 16.1 17.4
Medium m³/min 13.9 15.1
Low m³/min 11.5 12.7
Fan Motor Quantity 1 1
Model ARW30R8P43DA
Number of steps 5 5
Motor Speed High rpm 1240 1330
(cooling) Medium rpm 1090 1170
Low rpm 930 1010
Speed High rpm 1270 1360
(heating) Medium rpm 1120 1200
Low rpm 960 1040
Fan Motor Output W 43 43
(high)
Cooling Sound Power Medium dBA 59 61
Sound High dBA 43 45
Pressure Low dBA 34 36
Heating Sound Power Medium dBA 58 60
Sound High dBA 42 44
Pressure Low dBA 33 35
Refrigerant Type R-410A
Piping Liquid (OD) Diameter mm 6.4 6.4
connections (OD)
Gas Diameter mm 12.7 12.7
(OD)
Drain Diameter mm 18 18
(OD)
Heat Insulation Both liquid and gas pipes
Air Filter Removable/washable/Mildew proof
Air direction control Right, Left, Horizontal, Downward
Temperature control Microcomputer control

• Split Sky Air • Indoor Units 3


• Indoor Units • R-410A • FTYN-FV1B

2 Specifications

2-2 TECHNICAL SPECIFICATIONS FTYN50FV1B FTYN60FV1B


Standard Item Titanium apatite photocatalytic air purification filter
Accessories Quantity 2 2
Item Operation manual
Quantity 1 1
Item Installation manual
2
Quantity 1 1
Item Batteries
Quantity 2 2
Item Remote control holder Mounting plate
Quantity 1 1
Item Mounting plate Indoor unit fixing screws
Quantity 1 2
Item Indoor unit fixing screws Wireless remote control
Quantity 2 1
Item Wireless remote control
Quantity 1

2-3 ELECTRICAL SPECIFICATIONS FTYN50FV1B FTYN60FV1B


Power Supply Name V1
Phase 1 1
Frequency Hz 50 50
Voltage V 220-240
Current Nominal Cooling A 0.15 0.18
running current Heating A 0.16 0.20
(RLA)
Maximum Running Current A 0.17 0.21
Wiring For Power Quantity 3 3
connections Supply Remark 4 for interunit wiring (including earth wiring)

4 • Split Sky Air • Indoor Units


• Indoor Units • R-410A • FTYN-FV1B

3 Dimensional drawing & centre of gravity


3-1 Dimensional drawing
FTYN50-60F unit (mm) 3
Air flow (indoor)
(for performance and maintenance)
The mark (Y) shows piping direction

performance)
Rear Rear

30 Min.
(space for
Left Right

(space for
maintenance) 3
50 Min. 50 Min.
(space for
Required space maintenance)
(Including mounting plate)

Operation lamp
Model name plate
Signal receiver
Indoor unit ON/OFF
switch
Terminal block
Room temp. with earth
thermistor (Inside) terminal (inside)

Timer lamp
Gas pipe 12.7Cut (The length of pipe Drain hose for VP13 (connecting part
outside the unit: about 430) I.D.14.0, O.D.18.0)
Front grille fixing screws
Flaps (inside) (The hose length on the outside of
the unit is approx. 530)
Liquid pipe J6.4 CuT (the length of pipe outside
Signal the unit: about 480)
transmitter
Blade angles
Horizontal blade
(Automatic)
Cooling Heating Dry

Fan Wall hole J


Infrared remote control Vertical blade (Manual)
80 hole
(ARC433A72) Wall hole for embedded piping
J 80 hole
Standard locations of wall holes
3D054939A

• Split Sky Air • Indoor Units 5


• Indoor Units • R-410A • FTYN-FV1B

3 Dimensional drawing & centre of gravity


3-2 Centre of gravity
FTYN50-60F

4D040313X

6 • Split Sky Air • Indoor Units


• Indoor Units • R-410A • FTYN-FV1B

4 Piping diagram

FTYN50-60F
3
Indoor unit

Heat exchanger

Thermistor on heat
exchanger

Cross flow fan


Field piping

Fan motor
Field piping

Refrigerant flow
Cooling
Heating

4D040081P

• Split Sky Air • Indoor Units 7


• Indoor Units • R-410A • FTYN-FV1B

5 Wiring diagram
5-1 Wiring diagram
FTYN50-60F

g
Field wiring

5 Rectifier

Outdoor

CAUTION
Transmission circuit
Note that operation will restart
automatically if the main power
supply is turned off and then back
on again.

R : Protective earth
FG : Frame ground
FU : Fuse
H1∼H3 : Harness
H1P∼H2P : Pilot lamp
M1F : Fan motor
M1S : Swing motor
PCB1∼PCB4 : Printed circuit board
R1T,R2T : Thermistor
S1∼S38 : Connector
S1W : Operation switch
X1M : Terminal strip
Indoor
Signal receiver

Infrared remote
control

3D038532F

8 • Split Sky Air • Indoor Units


• Indoor Units • R-410A • FTYN-FV1B

6 Sound data
6-1 Sound pressure spectrum

FTYN50F (Cooling) FTYN50F (Heating)


3

Octave band sound pressure level


Octave band sound pressure level

dB:(0dB = 0.0002 μ bar)


dB:(0dB = 0.0002 μ bar)

approximate threshold
approximate threshold hearing for continuous
hearing for continuous noise
noise

3D050979A Octave band center frequency (Hz) 3D050979A Octave band center frequency (Hz)

NOTE NOTE
1 Operation noise differs with operation and 1 Operation noise differs with operation and
ambient conditions. ambient conditions.
2 Measure in anechoic room 2 Measure in anechoic room

Legend Legend
50Hz 220-240V (H) 50Hz 220-240V (H)
50Hz 220-240V (L) 50Hz 220-240V (L)

FTYN60F (Heating)
FTYN60F (Cooling)
Octave band sound pressure level
Octave band sound pressure level

dB:(0dB = 0.0002 μ bar)


dB:(0dB = 0.0002 μ bar)

approximate threshold
approximate threshold hearing for continuous
hearing for continuous noise
noise

3D051227A Octave band center frequency (Hz)


3D051227A Octave band center frequency (Hz)
NOTE
NOTE
1 Operation noise differs with operation and
1 Operation noise differs with operation and ambient conditions.
ambient conditions.
2 Measure in anechoic room
2 Measure in anechoic room

Legend
Legend
50Hz 220-240V (H) 50Hz 220-240V (H)
50Hz 220-240V (L) 50Hz 220-240V (L)

• Split Sky Air • Indoor Units 9


Split - Sky Air

The present publication is drawn up by way of ISO14001 assures an effective environmental Daikin units comply with the European
information only and does not constitute an offer management system in order to help protect human regulations that guarantee the safety
binding upon Daikin Europe N.V.. Daikin Europe N.V. health and the environment from the potential impact of of the product.
has compiled the content of this publication to the our activities, products and services and to assist in
best of its knowledge. No express or implied warranty maintaining and improving the quality of the
is given for the completeness, accuracy, reliability or environment.
fitness for particular purpose of its content and the
products and services presented therein. Specifications
are subject to change without prior notice. Daikin
Europe N.V. explicitly rejects any liability for any direct Daikin Europe N.V. is approved by LRQA for its Quality Daikin Europe N.V. is participating in the
or indirect damage, In the broadest sense, arising from Management System in accordance with the ISO9001 EUROVENT Certification Programme.
or related to the use and/or interpretation of this standard. ISO9001 pertains to quality assurance regarding Products are as listed in the EUROVENT
publication. All content is copyrighted by Daikin design, development, manufacturing as well as to services Directory of Certified Products.
Europe N.V.. related to the product.
Prepared in Belgium by Lannoo
EEDEN07-101 • 03/2007

Naamloze Vennootschap
Copyright © Daikin

Zandvoordestraat 300
B-8400 Ostend, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

ÉEEDEN07-1011ËÍ