You are on page 1of 382

Techlog Fundamentals

© 2011-2013 Schlumberger. All rights reserved.


Workflow/Solutions Training
Version 2012

Schlumberger Internal Use Only

Schlumberger Information Solutions


May 14, 2013
© 2011-2013 Schlumberger. All rights reserved.
Copyright Notice
© 2011-2013 Schlumberger. All rights reserved.

No part of this manual may be reproduced, stored in a retrieval system, or


translated in any form or by any means, electronic or mechanical, including
photocopying and recording, without the prior written permission of
Schlumberger Information Solutions, 5599 San Felipe, Suite100, Houston, TX
77056-2722.

Disclaimer
Use of this product is governed by the License Agreement. Schlumberger
makes no warranties, express, implied, or statutory, with respect to the product
described herein and disclaims without limitation any warranties of
merchantability or fitness for a particular purpose. Schlumberger reserves the
right to revise the information in this manual at any time without notice.

© 2011-2013 Schlumberger. All rights reserved.


Trademark Information
Software application marks used in this publication, unless otherwise indicated,
are trademarks of Schlumberger. Certain other products and product names
are trademarks or registered trademarks of their respective companies or
organizations.

An asterisk (*) is used throughout this document to designate a mark of


Schlumberger.
© 2011-2013 Schlumberger. All rights reserved.
Table of Contents

About this Manual


Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
What You Will Need . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
What to Expect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Course Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Module 1: Basics of the Techlog Window


Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Lesson 1: Components of the Main Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Procedure 1: Moving the Dock Windows . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Lesson 2: Main Dock Windows . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

© 2011-2013 Schlumberger. All rights reserved.


The Project Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Procedure 1: Filtering Data in the Project Browser . . . . . . . . . . . . . . . . . . . 15
Procedure 2: Applying Conditional Selections . . . . . . . . . . . . . . . . . . . . . . . 19
Procedure 3: Grouping Data Objects Manually . . . . . . . . . . . . . . . . . . . . . . 19
Procedure 4: Grouping Data Objects Automatically . . . . . . . . . . . . . . . . . . 21
Data Search . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Contextual Menu Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Trash Bin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Output Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Properties Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Procedure 5: Using the Properties Window . . . . . . . . . . . . . . . . . . . . . . . . 28
Zonation Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Markers Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Workspace Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Lesson 3: Synchronization Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Project Partial Loading Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Procedure 1: Disabling the Project Partial Loading Feature . . . . . . . . . . . . 34
Procedure 2: Linking Techlog to the Reference Repository . . . . . . . . . . . . . 34
Procedure 3: Retrieving Items from the Reference Repository . . . . . . . . . . 35
Procedure 4: Sending Items from the Current Project to the Reference
Repository . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Data Locking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Procedure 5: Locking Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Techlog Fundamentals, Version 2012 i


Lesson 4: Techlog Project Creation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Procedure 1: Creating a New Techlog Project . . . . . . . . . . . . . . . . . . . . . . 38
Exercise 1: Creating the My First Techlog Project . . . . . . . . . . . . . . . . . . . . 40
Techlog Project Folder Structure and Settings . . . . . . . . . . . . . . . . . . . . . . 43
Procedure 2: Opening an Existing Project . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Procedure 3: Opening an Older Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Module 2: Data Import and Export


Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Lesson 1: Data Import . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Procedure 1: Importing Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Lesson 2: DLIS File Import . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Exercise 1: Importing DLIS Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Lesson 3: LAS File Import . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
© 2011-2013 Schlumberger. All rights reserved.

Exercise 1: Importing LAS Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57


Lesson 4: Text File Import . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Exercise 1: Importing Stratigraphy Data from a TXT File . . . . . . . . . . . . . . . 60
Exercise 2: Importing the TOPS1 File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Exercise 3: Importing the TOPS2 File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Exercise 4: Importing the TOPS3 File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Lesson 5: CSV Spreadsheet Import . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Exercise 1: Importing a CSV Spreadsheet . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Exercise 2: Importing Formation Pressure Data . . . . . . . . . . . . . . . . . . . . . 68
Exercise 3: Importing a Thin Section Analysis Table . . . . . . . . . . . . . . . . . . 70
Lesson 6: Image File Import . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Procedure 1: Importing Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Exercise 1: Importing Core Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
Lesson 7: XML File Import . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Procedure 1: Importing XML Files from the Import Buffer . . . . . . . . . . . . . . 77
Procedure 2: Importing XML Files with a Drag-and-drop Method . . . . . . . . 78
Exercise 1: Loading the LQC data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Lesson 8: Time Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Exercise 1: Uploading Time Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Exercise 2: Uploading Time Data with Time Reference . . . . . . . . . . . . . . . . 84
Lesson 9: Well Identification Solver: Data Import under the Same Name . . . . . 86
Exercise 1: Importing Data with the Same Name . . . . . . . . . . . . . . . . . . . . 86
Lesson 10: Data Export . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Procedure 1: Exporting Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Exercise 1: Exporting Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90

ii Techlog Fundamentals, Version 2012


Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95

Module 3: Variable Management


Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
Lesson 1: Families Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Families Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
Procedure 1: Editing Family Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Export and Import Families . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Exercise 1: Editing Family Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Rules Activation and Deactivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Exercise 2: Creating a New Family . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Exercise 3: Using the Family Assignment Rules Tool . . . . . . . . . . . . . . . . 106
Lesson 2: Aliases Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Aliases Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Exercise 1: Adding a New alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
Exercise 2: Using the Alias Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115

© 2011-2013 Schlumberger. All rights reserved.


Exercise 3: Creating LQC Data sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119

Module 4: References Management


Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
Lesson 1: Index Data Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
Lesson 2: TVD Computation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
Procedure 1: Computing Depth Measurements . . . . . . . . . . . . . . . . . . . . 123
Exercise 1: Running a TVD Computation and Creating the Index
Data Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
Lesson 3: Index Data Set Creation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Exercise 1: Creating an Index Data Set . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131

Module 5: LogView
Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Lesson 1: LogView Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Lesson 2: LogView Plots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Track Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
Procedure 1: Inserting a Track . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
Exercise 1: Displaying Caliper Gamma Ray Sonic Data in Track 1 . . . . . . 142
Variable Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146

Techlog Fundamentals, Version 2012 iii


Procedure 2: Changing the Variable Management Type in LogView . . . . 147
Exercise 2: Checking the Variable Management Type for Track 2 . . . . . . 147
Variable Scales . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
Procedure 3: Managing the Horizontal Scale . . . . . . . . . . . . . . . . . . . . . . . 148
Exercise 3: Changing the Horizontal Scale for Density and Porosity Log
Data in Track 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Palette Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
Procedure 4: Changing the Palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
Exercise 4: Modifying the Palette for Tracks 4 and 5 . . . . . . . . . . . . . . . . . 151
Reference Tracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
Procedure 5: Displaying a New Reference Track . . . . . . . . . . . . . . . . . . . 151
Exercise 5: Creating a Reference Track for Track 6 . . . . . . . . . . . . . . . . . 152
Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Procedure 6: Creating a Zonation Track in a Layout . . . . . . . . . . . . . . . . . 154
Exercise 6: Creating a Zonation Track in a Layout for Track 7 . . . . . . . . . 155
Data Set Created from LogView . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
© 2011-2013 Schlumberger. All rights reserved.

Procedure 7: Creating a Data Set with All Data Displayed on the


Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
Exercise 7: Saving Variables from a Layout . . . . . . . . . . . . . . . . . . . . . . . 158
Lesson 3: Layout and Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Exercise 1: Saving the Layout Created as a Template . . . . . . . . . . . . . . . 159
Procedure 1: Applying a Template to Other Wells or Data Sets . . . . . . . . 159
Exercise 2: Applying the Well9_SHORT Template to Create Another
Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Exercise 3: Applying the Well9_SHORT Template to other Data Sets . . . 161
Lesson 4: More LogView Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Procedure 1: Inserting a Well Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . 165
Exercise 1: Inserting a Well Schematic for Track 3 . . . . . . . . . . . . . . . . . . 165
Plots in Tracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
Procedure 2: Creating Plots in Tracks . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
Exercise 2: Creating Plots in Tracks 6 and 9 . . . . . . . . . . . . . . . . . . . . . . . 170
Procedure 3: Displaying a Variable as Text . . . . . . . . . . . . . . . . . . . . . . . 171
Exercise 3: Displaying Variables as Text in Track 10 . . . . . . . . . . . . . . . . 171
Procedure 4: Hiding Zonation Shading in Tracks . . . . . . . . . . . . . . . . . . . . 172
Exercise 4: Displaying the STRATIGRAPHY Zonation as Patterns in
Track 10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Procedure 5: Creating a Cumulative Track . . . . . . . . . . . . . . . . . . . . . . . . 174
Exercise 5: Creating a Cumulative Track in Track 14 . . . . . . . . . . . . . . . . 175
Procedure 6: Displaying Core Images . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Exercise 6: Displaying Core Images in Track 16 . . . . . . . . . . . . . . . . . . . . 177

iv Techlog Fundamentals, Version 2012


Procedure 7: Using a Well Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
Exercise 7: Using a Well Overview in Track 17 . . . . . . . . . . . . . . . . . . . . . 177
Lesson 5: Time Data Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
Exercise 1: Creating a LogView Plot with Time Data . . . . . . . . . . . . . . . . . 178
Lesson 6: Basic Processing in LogView . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
Procedure 1: Applying a Processing Method . . . . . . . . . . . . . . . . . . . . . . . 181
Exercise 1: Applying the Smoothing Function to a DENS Variable . . . . . . 181
Lesson 7: Header Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Exercise 1: Editing a Header in Techlog . . . . . . . . . . . . . . . . . . . . . . . . . . 184
Lesson 8: Window Screenshot Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Procedure 1: Capturing Screenshots . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Lesson 9: Print Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Layout Printing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
Exercise 1: Printing a Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194

© 2011-2013 Schlumberger. All rights reserved.


Module 6: Plots
Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Lesson 1: Appearance of the Plot Interface . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Display and Icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Lesson 2: Plot Tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Variables Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Filter Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
Charts Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Exercise 1: Creating a Histogram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Exercise 2: Creating a Neutron-Density Crossplot . . . . . . . . . . . . . . . . . . 208
Exercise 3: Creating Additional Plots . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Lesson 3: Multi-well Plots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Procedure 1: Creating a Multi-well Plot . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Box Plot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Exercise 1: Creating a Multi-well Box Plot . . . . . . . . . . . . . . . . . . . . . . . . 212
Lesson 4: Matrix Plot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Procedure 1: Creating a Matrix Pot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Exercise 1: Creating a Histogram Matrix Plot . . . . . . . . . . . . . . . . . . . . . . 214
Lesson 5: Plot Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Polygon Type Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Interactive Selection Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Statistics Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220

Techlog Fundamentals, Version 2012 v


Lesson 6: Regressions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Display Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Procedure 1: Entering an Equation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Procedure 2: Editing, Removing, and Copying an Equation . . . . . . . . . . . 225
Procedure 3: Saving the Display Properties . . . . . . . . . . . . . . . . . . . . . . . 225
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226

Module 7: Depth Interaction, Interactive Selection Mode, Zonation, and


Markers
Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Lesson 1: Depth Interaction Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Procedure 1: Setting the Depth Interaction Line . . . . . . . . . . . . . . . . . . . . 229
Exercise 1: Using the Depth Interaction Tool . . . . . . . . . . . . . . . . . . . . . . . 230
Lesson 2: Interactive Selection Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
Procedure 1: Using Interaction in the General Workspace . . . . . . . . . . . . 233
© 2011-2013 Schlumberger. All rights reserved.

Exercise 1: Working with Interaction in the General Workspace . . . . . . . 233


Exercise 2: Creating a Zonation Data Set using Interactive Selection . . . 237
Lesson 3: Zonation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Procedure 1: Using a Zonation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Lesson 4: Zone Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Procedure 1: Loading and Editing Data in the Zone Editor . . . . . . . . . . . . 246
Procedure 2: Adding a Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Miscellaneous Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
Exercise 1: Editing a Zonation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Procedure 3: Creating a Zone with the Quick Zone Creation Tool . . . . . . 252
Graphical Tools for Editing Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Exercise 2: Creating Zones using the Quick Zone Creation Tool . . . . . . . 256
Zones Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Procedure 4: Picking Zones in LogView using the Zone Manager . . . . . . 260
Exercise 3: Picking Lithologies using Advanced Zones Creation . . . . . . . 261
Exercise 4: Using a Zonation to Define an Area Fill . . . . . . . . . . . . . . . . . 264
Lesson 5: Markers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Exercise 1: Creating a Markers Data Set . . . . . . . . . . . . . . . . . . . . . . . . . 267
Procedure 1: Creating a Marker from Zonation . . . . . . . . . . . . . . . . . . . . . 269
Exercise 2: Creating a Marker Data Set from the STRATIGRAPHY
Data Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272

vi Techlog Fundamentals, Version 2012


Module 8: Data Editor
Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Lesson 1: Data Editor Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Data Editor Window Tabs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Exercise 1: Creating a New Data Set in the Data Editor . . . . . . . . . . . . . . 285
Lesson 2: New Variable Calculation and Mathematical Operations . . . . . . . . 287
Procedure 1: Working with Equations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
Procedure 2: Editing an Equation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
Procedure 3: Removing an Equation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
Exercise 1: Using the Data Editor to Create an Equation . . . . . . . . . . . . . 292
Procedure 4: Displaying Variable Array Type Data . . . . . . . . . . . . . . . . . . 292
Exercise 2: Computing a Variable with an Array Variable . . . . . . . . . . . . . 294
Lesson 3: Excel Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Procedure 1: Connecting with Excel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Exercise 1: Exporting and Importing the GAMM Curve . . . . . . . . . . . . . . . 296
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296

© 2011-2013 Schlumberger. All rights reserved.


Module 9: Well Trajectories, Field Map, and Well Predict
Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
Lesson 1: 2D Well Trajectories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
Exercise 1: Displaying the Well9 Trajectory in 2D . . . . . . . . . . . . . . . . . . . 299
Lesson 2: 3D Well Trajectories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
Procedure 1: Creating a 3D Well Trajectory . . . . . . . . . . . . . . . . . . . . . . . 302
Exercise 1: Creating a 3D Well Trajectory . . . . . . . . . . . . . . . . . . . . . . . . 303
Lesson 3: Basemap Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
Procedure 1: Creating a Base Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
Exercise 1: Creating a Base Map and Displaying Plots on the Map . . . . . 305
Exercise 2: Creating a Cross Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
Lesson 4: Well Predict . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Procedure 1: Starting Well Predict . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Exercise 1: Using Well Predict . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317

Module 10: Depth Shifting Tool and Variables Splice Tool


Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Lesson 1: Manual Depth Shifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Procedure 1: Creating a Depth Shifting Window . . . . . . . . . . . . . . . . . . . . 319
Procedure 2: Depth Shifting a Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Important Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321

Techlog Fundamentals, Version 2012 vii


Procedure 3: Saving the Depth Shift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322
Procedure 4: Applying a Depth Shifting . . . . . . . . . . . . . . . . . . . . . . . . . . 322
Procedure 5: Block Shifting a Curve (Special Feature) . . . . . . . . . . . . . . . 323
Procedure 6: Applying a Horizontal Shift to a Curve . . . . . . . . . . . . . . . . . 323
Lesson 2: Automatic Depth Shifting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Procedure 1: Automatically Depth Shifting a Curve . . . . . . . . . . . . . . . . . . 323
Properties Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
Automatic Shift Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
Exercise 1: Depth Shifting a Variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327
Procedure 2: Depth Shifting a Variable from the Project Browser . . . . . . . 331
Procedure 3: Depth Shifting a Variable from the Layout . . . . . . . . . . . . . . 333
Exercise 2: Depth Shifting a Data Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335
Variables Splice Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
Procedure 4: Splicing Data Sets in the Variables Splice Tool . . . . . . . . . . 339
Exercise 3: Creating a Data Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
© 2011-2013 Schlumberger. All rights reserved.

Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344

Module 11: Project Data Management


Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
Learning Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
Lesson 1: Project Browser Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347
Exercise 1: Creating a Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
Lesson 2: Issues in the Data Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
Project Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
Inventory Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
Exercise 1: Identifying Issues in a Data Set . . . . . . . . . . . . . . . . . . . . . . . . 352
Lesson 3: Data Harmonization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354
Data Harmonization using the Project browser . . . . . . . . . . . . . . . . . . . . . 354
Procedure 1: Performing Data Harmonization using the Inventory Tool . . 355
Data Harmonization using Data Harmonization Tools . . . . . . . . . . . . . . . . 355
Data Harmonization Tools Scenarios . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357
Data Harmonization Exercises . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
Exercise 1: Correcting a Missing Unit for a Variable in a Well . . . . . . . . . . 361
Exercise 2: Correcting a Missing Unit for Variable
RHOB_DH_ADN_RT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
Exercise 3: Correcting an Unknown Unit . . . . . . . . . . . . . . . . . . . . . . . . . . 361
Exercise 4: Correcting a Missing Unit for Variable TNPH_ADN_RT . . . . . 363
Exercise 5: Correcting a Missing Family . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Exercise 6: Correcting an Unknown Family . . . . . . . . . . . . . . . . . . . . . . . . 363
Exercise 7: Correcting a Variable Assigned to Multiple Families . . . . . . . . 364

viii Techlog Fundamentals, Version 2012


Exercise 8: Correcting a Variable that is not Harmonized . . . . . . . . . . . . . 364
Exercise 9: Correcting a Variable that has Two Units . . . . . . . . . . . . . . . . 364
Exercise 10: Correcting a Variable that has an Incorrect Unit . . . . . . . . . . 365
Exercise 11: Adding a Suffix to Variables . . . . . . . . . . . . . . . . . . . . . . . . . 365
Exercise 12: Correcting a Value that is Inconsistent with its Unit . . . . . . . 365
Review Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 ix


© 2011-2013 Schlumberger. All rights reserved.

x
Techlog Fundamentals, Version 2012
Schlumberger Internal Use Only About this Manual

About this Manual

This manual discusses the platform tools implemented within


Techlog*. Techlog is a wellbore-centric petrophysical application
composed of a platform and a suite of add-on application
modules. The platform, which is the subject of this manual,
comprises tools for loading, visualizing, and editing your data.

You will learn how to load data from various vendors and sources,
display the data using the various viewers, and use a variety of
tools to prepare the data quality control. You will become
proficient with the platform tools and you will gain an
understanding of the major principles governing the software. This
training will prepare you for additional courses and advanced
training.

© 2011-2013 Schlumberger. All rights reserved.


Learning Objectives
After completing this training, you will know how to:

• load various types of data, including logs, cores, images,


arrays, and zone tops
• visualize the data using a variety of visualization tools
• manipulate data at a simple curve level (editing, smoothing)
and at the data set level (depth shifting, splicing,
harmonizing).
• find functions among the editors and graphics tools.

What You Will Need


In this training you will need the following documents, hardware,
and software:

• One of these operating systems:


• Windows 7 (32-bit or 64-bit)
• Windows Vista (32-bit or 64-bit)
• Windows XP (32-bit or 64-bit)
• 8 GB RAM

Techlog Fundamentals, Version 2012 1


About this Manual Schlumberger Internal Use Only

• Techlog installation file


• Techlog license file.

What to Expect
In each module within this training material, you will encounter
these types of information:

• Overview of the module


• Prerequisites to the module (if necessary)
• Learning objectives
• A workflow component (if applicable)
• Lessons, explaining a subject or an activity in the workflow
• Procedures, showing the steps needed to perform a task
© 2011-2013 Schlumberger. All rights reserved.

• Exercises, which allow you to practice a task by using the


steps in the procedure with a data set
• Scenario-based exercises
• Questions about the module
• Summary of the module.
You also will encounter notes, tips and best practices.

2 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only About this Manual

Course Conventions
Content in this manual uses the following conventions.

Characters in Bold Names of windows, dialog boxes,


menus and tabs, such as “the Open
Asset Model dialog."
Keyboard commands and action
buttons, such as "click OK."
Names of tools and icons, such as
“Query tool”
Schlumberger software application
names, such as Petrel*, Techlog*, or
ECLIPSE*
Characters in italics Names of files, directories and drive
navigation paths, such as “the
sample.dat file.”

© 2011-2013 Schlumberger. All rights reserved.


Names of sections and areas in
windows and dialog boxes, such as
“Experiments area”
First use of important terms or
concepts, such as compositional
simulation or “Safe mode is used
when...”
Characters in fixed-width Code, data, and other literal text the
user sees or enters, such as “Enter
0.7323.”
Characters in Times Names of options, functions,
processes, lists, columns, check
boxes, and radio buttons

Instructions to make menu selections are written using bold text


and arrows indicating the selection sequence, for example,
“Select File > Save.”

Techlog Fundamentals, Version 2012 3


About this Manual Schlumberger Internal Use Only

Icons
Throughout this manual, you will find icons in the margin
representing various kinds of information. These icons serve as
at-a-glance reminders of their associated text. See below for
descriptions of what each icon means.
© 2011-2013 Schlumberger. All rights reserved.

4 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only About this Manual

Summary
In this introduction, we:

• defined the learning objectives for Techlog introductory


training
• described the structure of the manual
• outlined what tools you will need for this training
• discussed course conventions that you will encounter within
this material.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 5


About this Manual Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

6 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Module 1 Basics of the Techlog


Window
The Techlog window is very flexible. You can customize its
appearance and organization to suit your working habits. Begin by
learning the default location and functionality of each window.

Learning Objectives
After completing this module, you will be familiar with the primary
components of the Techlog main window (Figure 1) and you will
know how to:

• customize the interface of Techlog


• access project data

© 2011-2013 Schlumberger. All rights reserved.


• access Techlog modules
• create a Techlog Project.

Techlog Fundamentals, Version 2012 7


Basics of the Techlog Window Schlumberger Internal Use Only

Lesson 1 Components of the Main


Window

In this lesson, you will learn about the components that make up
the main Techlog window and the function of each component.
© 2011-2013 Schlumberger. All rights reserved.

Figure 1 Main dock windows in Techlog

1 Title bar Indicates the version of Techlog, the


name of the project, the status of the
project, and the name of the active
workspace.
2 Menu bar Shows the Techlog domain menus:
Home, Plot, Utility, Petrophysics,
Geology, Drilling, Reservoir, and
Geophysics.

The icons at the right end of the menu


bar can be used to increase the size of
the display area.

• Click to hide the Toolbar menu.

• Click or press F11 to hide the


dock windows. To restore the dock
windows view, click or press
F11.

8 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

3 Toolbar Displays the icons that allow you to


access Techlog tools and plots under
the Techlog menu quickly. By clicking
on the bottom left corner of the toolbar
groups, you can collapse or expand a
group/module.

The toolbar contains commands related


to the project and the modules active in
the project.
4 Project Shows all the data and Techlog objects
browser loaded in the project.

Any global action on the database, such


as data importing or data filtering, can be
done in the Project browser.

© 2011-2013 Schlumberger. All rights reserved.


5 Output Displays messages from the system,
window including information and warnings, and
allows you to diagnose issues when
working in Techlog.
6 Display Displays all Techlog objects (LogView,
area crossplots, histograms).
7 Properties Displays properties of the selected
window objects. Most Techlog objects can be
retrieved, modified, and configured from
this window, including the units of a
variable and parameters.
8 Workspace Allows you to switch from one workspace
manager to another. Techlog operates a system
of independent workspaces to optimize
display.
9 Palette Allows you to select, create, and modify
editor color palettes.
10 Zonation Stores all of the interval sets within the
window project. It also allows you to limit data
display and analysis to a specific set of
intervals.
11 Markers Shows all the markers stored within the
window project.

Techlog Fundamentals, Version 2012 9


Basics of the Techlog Window Schlumberger Internal Use Only

12 Contact Allows you to manage contacts in the


manager project.
13 Action Displays a list of all the possible actions
manager available on the selected object.
14 Status bar Provides information about available
memory and disk space.

Procedure 1 Moving the Dock Windows

All of the windows described in this lesson are dockable. This


means that they can be re-arranged at your convenience.

To display the dock windows list, right-click in the Toolbar and


select the Dock windows menu.

TIP: You also can activate or deactivate a dockable window


© 2011-2013 Schlumberger. All rights reserved.

from the Dock windows menu.

1. To move the Project browser, click on the window header


and drag it to the right. The Project browser is now an
independent window that can be moved to another monitor.
Dashboard mode allows you to display windows outside the
Techlog window. This way you can have the application
open on one monitor and all the other windows (such as
Properties, Project browser, and Zonation) open on a
second monitor.

2. Move the Project browser above the Properties window.


The Project browser and the Properties window are now
docked, with two tabs displayed in the same window.
3. Restore the windows to their default position. In the View
menu, click Restore default positions .

NOTE: It also is possible to pin (auto-hide) the dock


windows individually to the left, right, or bottom.

10 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Lesson 2 Main Dock Windows

In this lesson, each of the main dock windows in Techlog is


described in detail.

The Project Browser


The Project browser is where you access and display various
Techlog objects and perform simple operations.

Click Datasets to view a list of Techlog objects, including project


wells, data sets, and variables (Figure 2 and Figure 3). The icons
representing data sets or variables provide you with information
about the data set or the type of variable.

© 2011-2013 Schlumberger. All rights reserved.

Figure 2 List of objects

Techlog Fundamentals, Version 2012 11


Basics of the Techlog Window Schlumberger Internal Use Only
© 2011-2013 Schlumberger. All rights reserved.

Figure 3 Saved layouts, plots, and workflows

12 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Project browser appearance


You use these icons in the Project browser to access and display
various types of information.

All objects in the project

Project wells

Layout, track template, and headers

Python scripts

Histograms and crossplots

Ipsom workspace maps, Kmod, and


classifications

© 2011-2013 Schlumberger. All rights reserved.


Workflows and workflows parameters

Deleted objects

Techlog Fundamentals, Version 2012 13


Basics of the Techlog Window Schlumberger Internal Use Only

Saved Levels
By default, only the objects saved at the Project level are
displayed in the Project browser. To display the objects that are
saved at any other level, right-click on the project header, where
the location path of your project is written, and select the level that
you wish to display, as shown in Figure 4.
© 2011-2013 Schlumberger. All rights reserved.

Figure 4 The four Techlog levels (Project, User, Company,


Techlog) displayed in the Project browser

You can select to display the family name and unit and sort the
objects in ascending or descending order.

14 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Procedure 1 Filtering Data in the Project


Browser

You can filter the data displayed in the Project browser to show
only what you want to view. After you apply a filter, only the
elements matching the filter criteria are displayed and the Project
browser changes color.

There are two methods in Techlog for managing filters. This


procedure shows you how to filter data by using the Filter tab or
the Create a filter menu command.

1. In the Project browser Properties window, open the


Filter tab and select the filter criteria for these options:
• Well: Apply a filter with a specific well name, or with the last
modification date or date of creation.

© 2011-2013 Schlumberger. All rights reserved.


• Dataset: Apply a filter with a specific data set name,
sampling, last modification date, date of creation, or type.
You can make several selections at one time.
• Variable: Apply a filter with a specific variable name, main
family, family, unit, version status, last modification date,
type, or description. You can make several selections at one
time.
• Group: Apply a filter with a group name.
Common operators are AND (&) and OR (|), but you also can
use an asterisk (*).

Techlog Fundamentals, Version 2012 15


Basics of the Techlog Window Schlumberger Internal Use Only

NOTE: More information about the syntax can be found in


the Techlog Help file.
© 2011-2013 Schlumberger. All rights reserved.

16 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

2. Alternatively, select variables, wells, and data sets in the


Project browser, right-click and select Create a filter.

© 2011-2013 Schlumberger. All rights reserved.

The variable, data set, or well selected is updated in the


Project browser Properties window.

Techlog Fundamentals, Version 2012 17


Basics of the Techlog Window Schlumberger Internal Use Only

After a filter is created, the Project browser changes color


and only the variables, data set, and wells selected by the
filter are displayed.
© 2011-2013 Schlumberger. All rights reserved.

3. Remove a filter by right-clicking in the Project browser and


selecting Remove the current filter.

18 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Procedure 2 Applying Conditional Selections

Conditional selection is an option that allows you to select one or


several curves, wells, or data sets. For example, you can use this
option to select specific curves to drag into a LogView layout.
Conditional selection is available only in the Project browser.

Similar to the filter option, there are two ways to manage


conditional selection in Techlog, in the Properties window and
with the Conditional selection command.

1. In the Project browser Properties window, open the


Conditional selection tab and select the filter criteria for
the Well, Dataset, Variable, and Group options.
The variables, data set, and wells selected by the conditional
selection are highlighted in gray.

© 2011-2013 Schlumberger. All rights reserved.


2. To remove a conditional selection, click in the Project
browser.

Procedure 3 Grouping Data Objects Manually

You can group wells, data sets, and variables manually according
to the properties available in the wells, data sets, and logs.
Manual grouping is accessed from the Project browser.

1. In the Project browser, select at least two wells, data sets,


or variables.
2. Right-click and select Group.
3. In the window that opens, enter a name for the group and
click OK. The group is created and displayed in the Project
browser.

Techlog Fundamentals, Version 2012 19


Basics of the Techlog Window Schlumberger Internal Use Only

TIP: You can group any objects in the Project browser.


© 2011-2013 Schlumberger. All rights reserved.

20 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Procedure 4 Grouping Data Objects


Automatically

You can use the Properties window to group wells, data sets, or
variables automatically.

1. In the Project browser Properties window, open the


Grouping tab.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 21


Basics of the Techlog Window Schlumberger Internal Use Only

2. Select one of these options for the Display type.


• Techlog: Wells, data sets, and variables are not grouped.
• Hierarchical grouping: Wells, data sets, and variables are
grouped according to wells, data sets, or variables
properties (based on country in the figure in Step 1).
• Project: Wells, data sets, and variables are grouped
according to the user.
3. Enter the grouping criteria.
This figure shows examples of how objects are displayed in
the Project browser based on the display type and grouping
criteria.
© 2011-2013 Schlumberger. All rights reserved.

22 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Data Search
You can use the search field in the Project browser to quickly
display all the variables or objects that contain the search word
that you enter. In the example shown in Figure 5, the word gamm
is entered as the search criteria and all wells and histograms that
contain a variable named gamm are displayed in the Project
browser.

Figure 5 Example of a search from the Project browser © 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 23


Basics of the Techlog Window Schlumberger Internal Use Only

Contextual Menu Commands


You can right-click on a well, data set, or a variable to access an
interactive list of the actions available for each Techlog object.
This list of actions is called the contextual menu.

The actions available in the contextual menu depend on the object


you select. You can apply these actions to wells, data sets, and
variables directly from the Project browser.
© 2011-2013 Schlumberger. All rights reserved.

Figure 6 Contextual menus for a well, data set, and variable

Trash Bin
The trash bin allows you to store data deleted from the Project
browser.

WARNING: Be aware that if data is deleted with the Delete


command, it will be stored in the trash bin and you
can retrieve it. However, if data is deleted with the
Delete definitively command, it cannot be
retrieved.

24 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Output Window
The Output window contains information about every operation
being run in Techlog. These messages provide you with valuable
information and alert you to issues with the applications.

Messages display in one of three colors, depending on the


content of the information.

• Green is for information.


• Orange is a warning.
• Red is for errors.
• Blue is for command lines.
Each error and warning message is documented with an
explanation about why the error or warning occurred. Figure 7
shows a sample green information message.

© 2011-2013 Schlumberger. All rights reserved.


Figure 7 Information message after importing a data set

Properties Window
The Properties window displays the parameters of any selected
object such as a variable, a workflow, or a log view. The content of
the window depends on the selected object. The window allows
you to edit the properties of the object.

Techlog Fundamentals, Version 2012 25


Basics of the Techlog Window Schlumberger Internal Use Only

For example, if you select the variable DENS in a layout, the


window will show the display properties of this variable. Figure 8
shows these identifying elements of an object when it is selected
in the Properties window.
© 2011-2013 Schlumberger. All rights reserved.

Figure 8 Key items in the Properties window

1 Tabs Tabs to access the parameters and


properties of the object
2 Object type Type of the selected object
3 Well, dataset, Full name of the object
variable name

26 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

4 Editable Properties that you can edit for the


properties object. You can edit only those
properties that are highlighted in green.

Figure 9 shows examples of the properties that are displayed for a


well, data set, and variable.

© 2011-2013 Schlumberger. All rights reserved.


Figure 9 Examples of different items displayed in the
Properties window, depending on the selected
object

Techlog Fundamentals, Version 2012 27


Basics of the Techlog Window Schlumberger Internal Use Only

Procedure 5 Using the Properties Window

You should keep the Properties window open at all times. You
also can use the F4 shortcut to display the Properties window for
any object in Techlog.

In this procedure, you use the F4 button to make the Properties


window display or not display.

1. Press F4 to bring the Properties window to the front.


NOTE: You can edit the unit of the variable manually.

2. Press F4 again to dock the Properties window in its original


place.

Zonation Window
© 2011-2013 Schlumberger. All rights reserved.

The Zonation window stores all of the interval sets in the project.
Zones selected in the Zonation window are reflected in plot
displays and workflows.

To select zones, choose the name of the set from the drop-down
list (Figure 10). In this example, only one set, named
STRATIGRAPHY, exists.

Figure 10 Selecting a zonation data set

28 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

After you select a data set, a list appears that contains all of the
zones within the zonation set. For example, in a layout, the selected
zones in the Zonation window are highlighted in the layout
(Figure 11).

© 2011-2013 Schlumberger. All rights reserved.


Figure 11 Zones selected in the zonation window are
highlighted in the LogView display

Techlog Fundamentals, Version 2012 29


Basics of the Techlog Window Schlumberger Internal Use Only

Markers Manager
The Markers dock window shows you all the markers available in
your project.

• Click on the drop-down menu to select the marker type data


set you want to display.
• Use the Marker pane to select those specific markers you
want to display.
© 2011-2013 Schlumberger. All rights reserved.

Figure 12 Markers manager

Workspace Manager
The Workspace manager lists the workspaces open in Techlog
and the windows open within each workspace, such as plots and
workflows. Figure 13 shows the active windows and workspaces
displayed in bold.

You can rename and save the workspace. When you reopen the
workspace, the windows will be arranged in the same way as they
were when you saved the workspace.

30 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

In Figure 13, the active window is the layout UnknownMW in the


workspace named Techlog workspace.

© 2011-2013 Schlumberger. All rights reserved.


Figure 13 Workspace manager showing several workspaces

You can switch from one workspace to another by double-clicking


on the workspace that you want to switch to in the Workspace
manager.

Techlog Fundamentals, Version 2012 31


Basics of the Techlog Window Schlumberger Internal Use Only

You also can close windows or entire workspaces from the


contextual menu (Figure 14).
© 2011-2013 Schlumberger. All rights reserved.

Figure 14 Closing workspaces and windows with the


contextual menu

TIP: Hover the mouse over a saved workspace to preview its


content.

32 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Lesson 3 Synchronization Tool

The Synchronization tool allows the asset teams to work in a


collaborative environment where data can be transferred to and
from a shared Techlog project.

Each team member must create a personal project on their local


space and from this personal project, they can link to the shared
one. After the projects are linked, team members can share their
data with the community through a send and retrieve mechanism.

© 2011-2013 Schlumberger. All rights reserved.


Figure 15 How the Synchronization tool works

Project Partial Loading Feature


It is recommended that you disable the Project partial loading
functionality when using the Synchronization tool, because the
Synchronization tool displays only the wells loaded in the
Project browser. Using the Project partial loading feature might
lead to a mismatch between the Reference repository and the
current project.

Techlog Fundamentals, Version 2012 33


Basics of the Techlog Window Schlumberger Internal Use Only

Procedure 1 Disabling the Project Partial


Loading Feature

This procedure shows you how to disable the Project partial


loading feature in Techlog.

1. Go to the Project tab in the Project browser Properties


window.
2. Select Options.
3. Go to the Parameters tab.
4. Clear the Partial project loading check box.
5. Click OK to validate.

Procedure 2 Linking Techlog to the Reference


Repository
© 2011-2013 Schlumberger. All rights reserved.

NOTE: This procedure assumes that the Reference repository


is created already.

1. Create a new Techlog project on your private disk space.


2. In the Techlog main window, select Utility >
Synchronization > Synchronization tool.

3. Click Link and browse to the location of Reference


repository. The Current project is now linked to the
Reference repository.

34 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Procedure 3 Retrieving Items from the


Reference Repository

This procedure shows you how to retrieve items from the


Reference repository to include them in your current project.

1. From the Reference repository pane, select the items to


retrieve.

2. Click to move the items to the Current project pane.

© 2011-2013 Schlumberger. All rights reserved.


3. Click Close to exit the Synchronization tool. The items are
displayed in the Project browser.
NOTE: The Send and Retrieve actions are performed at the
data set level only.

Techlog Fundamentals, Version 2012 35


Basics of the Techlog Window Schlumberger Internal Use Only

Procedure 4 Sending Items from the Current


Project to the Reference
Repository

In this procedure, you send items from a local project to the


reference repository.

1. After you worked on your data, reopen the Synchronization


tool.
2. From the Current project pane, select the items that you
modified.

3. Click to send the items you modified to the Reference


repository pane.
© 2011-2013 Schlumberger. All rights reserved.

Data Locking
You can lock data to prevent other users from overwriting the data
that you currently are working with. When data is locked, other
users still can retrieve them and modified them locally (in each
user project), but they cannot send their own changes to the
Reference repository.

You can lock data and view the locked items from either the
Current project or Reference repository pane. However, the
items are locked in the Reference repository pane only.

Therefore, items that exist only in the Current project cannot be


locked. In case of an error, a warning window opens listing all the
objects that were not locked in the Reference repository.

36 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Procedure 5 Locking Data

If you want to send a Techlog object to the Reference


repository, you must lock it first.

1. From both Synchronization tool panes, select the items to


lock.
2. Click Lock.
3. Click Close to validate. From the Project browser, you can
see a padlock on each locked item.
NOTE: From the Project browser, you can see only the
data that you locked. Go to the Synchronization tool
to see the data locked by other users.

© 2011-2013 Schlumberger. All rights reserved.


If another user forgets to unlock the data, a data
administrator can unlock them.

If all the items in a specific group are locked, a padlock on


the group name is displayed.

If you have items inside a group with at least two different


lock statuses, the icon is displayed in the parent Lock
status column.
NOTE: When several users use the same Reference
repository to exchange modified data, some
conflicts might appear between your Current project
and the Reference repository. Several tools exist to
resolve potential conflicts. A discussion of these tools
is beyond the scope of this training. More information
is available in the Techlog User Guide.

Techlog Fundamentals, Version 2012 37


Basics of the Techlog Window Schlumberger Internal Use Only

Lesson 4 Techlog Project Creation

In this lesson, you will learn how to create a new project in


Techlog.

Procedure 1 Creating a New Techlog Project

The first time you open Techlog, most of the menus and dock
windows are disabled (they appear in gray). This is because no
project is open. You will need to create a new project first.

The Project template option allows companies to define clear


formats for any feature in Techlog that must be applied for a
dedicated addressee. This option typically is offered to service
companies that deliver standard output on a per customer basis.

The Project template option copies the whole project (including


© 2011-2013 Schlumberger. All rights reserved.

data) defined as a template into the newly created project. All of


the settings applied in the project template then are available for
the new data that will be loaded into the new project.

1. In the Techlog main window, select Project > New to


open the New project wizard.
2. In the New project wizard, enter this information:
• Project name: Avoid using a slash (\) in the project name.
• (optional) Country: Entering a country will help you to filter
your projects later.
• (optional) Description: Enter information about the project.
3. Click Next to go to the Folder, status and type page.
The project is added to your Project folder automatically. If
you wish to store it in another directory, click the ellipses (...)
button to navigate to and select another location.

4. (optional) Choose a Project template from the list, or


browse for it by clicking the ellipses (...) button.
5. Set these options for the project template:
• Project status: In progress or temporary.
• Project opening default mode: In Techlog 2012, only single-
user is available (options are read/write or read only).

38 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

• Project plug-in: For best performance, choose SQLite.


• Unit system (optional): This option is available only if a
company folder exists.
6. Click Next.
A message appears asking you to confirm the creation of the
new project folder.

7. Select the modules that you wish to use. You can change this
selection after you create the project.
8. Click Finish.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 39


Basics of the Techlog Window Schlumberger Internal Use Only

Exercise 1 Creating the My First Techlog


Project

In this exercise, you create your first Techlog project named My


First Techlog Project.

1. In the Techlog main window, select Project > New to


open the New project wizard.
2. Enter the Project name, Country, and Description.
© 2011-2013 Schlumberger. All rights reserved.

40 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

3. Click Next.
The Folder, status and type window opens. In this window,
you can modify the storage path for your project. For this
exercise, use these values:

• Project status: In progress


• Project opening default mode: single user [read/write]
• Project plug-in: SQlite
• Unit system: Undefined (for the moment, no company folder
is installed).

© 2011-2013 Schlumberger. All rights reserved.

4. Click Next.
A confirmation dialog box opens asking you to confirm the
project folder creation.

5. Click Create.
Techlog creates the new project folder.

Techlog Fundamentals, Version 2012 41


Basics of the Techlog Window Schlumberger Internal Use Only

6. Select the modules that will be checked out when you open
the project.
© 2011-2013 Schlumberger. All rights reserved.

7. Click Next.
The project has now been created. Techlog displays a
summary of your project characteristics.

42 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

8. Click Finish to open your newly created project.


Notice that all of the icons are now active. You can start to
upload data into your project.

Techlog Project Folder Structure and Settings


When a project is created, Techlog creates a structure of folders
as shown in Figure 16. Each of these folders contains all of the
objects (such as plots, layouts, and processing parameters) saved
at the Project level.

© 2011-2013 Schlumberger. All rights reserved.


Figure 16 Project folder structure

The project settings are stored in Settings.xml file located in the


Settings directory. This file contains this information:

• Name of the project


• Name of the person who created the project
• Creation date
• Modification log
• Opening mode
• Licenses used in the project.

Techlog Fundamentals, Version 2012 43


Basics of the Techlog Window Schlumberger Internal Use Only

Procedure 2 Opening an Existing Project

You can open an existing project from the Project menu where
the most recent Techlog projects are listed.

1. In the Techlog main window, select Project > Recent


projects.
A list of the ten most recently saved projects appears.

2. Select the project you want to open.


© 2011-2013 Schlumberger. All rights reserved.

A confirmation window opens asking if you want to replace


the current project or open the project in a new Techlog
session.

44 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

Procedure 3 Opening an Older Project

This procedure shows you how to open a project if it is not one of


the ten most recently saved projects.

1. In the Techlog main window, select Project > Open to open


the Project selection window.
2. Select the project you want to open, then click Open.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 45


Basics of the Techlog Window Schlumberger Internal Use Only

Review Questions
• How can you access the list of dock windows?
• How do you change from Dashboard mode to Floating
mode?
• Give three actions that you can do from the Project
browser.
• Where can you read the system messages, including
information and warnings, that might help you to understand
issues arising in your project?
• What is the shortcut to display the Properties window?

Summary
In this module, you learned about:
© 2011-2013 Schlumberger. All rights reserved.

• using the Techlog main window


• customizing the interface of Techlog
• accessing project data
• accessing Techlog modules
• creating a Techlog project.

46 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Basics of the Techlog Window

NOTES

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 47


Basics of the Techlog Window Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

48 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

Module 2 Data Import and Export


Techlog can integrate many types of data, including log data,
point data, seismic, deviation files, and image files. Techlog also
supports a variety of the most common formats, including LAS,
GeologASCII, DLIS/LIS, ASCII file with the wizard, core images,
TechCSV, and the Techlog format (XML).

In addition, you can export data or any object created in Techlog


(such as plots and layouts) from Techlog to various format such
as LAS, DLIS, GeologASCII, ASCII file, TechCSV, and the
Techlog format (XML).

Learning Objectives
After completing this module, you will know how to:

© 2011-2013 Schlumberger. All rights reserved.


• import data files, such as DLIS, LAS, and TXT formats
• import spreadsheet files
• import image files, such as PNG and TIFF
• import XML Techlog files
• export data from Techlog
• use the Well Identification Solver.

Lesson 1 Data Import

You can import data in four ways:

• Drag the files to be imported into Techlog (LAS, DLIS,


Techlog XML, CSV files).
• Select Project > Import from the main Techlog window.

• Select Home > Import .


• Press Ctrl + Shift + J,I.
Regardless of the method you choose, the action opens the
import buffer (Figure 17) in the Project browser window.

Techlog Fundamentals, Version 2012 49


Data Import and Export Schlumberger Internal Use Only

The import buffer holds all of the data that you choose to import in
a temporary space. You can quality check the properties of each
variable before you import it into the project.
© 2011-2013 Schlumberger. All rights reserved.

Figure 17 Project browser (left) and the import buffer (right)

50 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

Procedure 1 Importing Data

This procedure is applicable for most of the files you will load into
Techlog.

1. Select Home > Import to open the import buffer.

2. Click Open and browse for the files to be imported.


3. If the data cannot be parsed automatically by Techlog, the
ASCII Import wizard opens.
4. In the Properties window of the wizard (on the right side),
define these parameters:
• The data set type you wish to import: continuous, point
data, or interval. (If you are importing zonation data sets,
make sure the Dataset type property is set to interval .)

© 2011-2013 Schlumberger. All rights reserved.


• The location of header information in the ASCII file (Import
from line, Variable name line, and Unit line).
• Delimiter settings.
5. Click Preview.
6. In the Preview window, define these parameters:
• Reference column (mandatory)
• If applicable, the Well name and Dataset name columns.
You can remove the unnecessary columns by clicking
Remove column(s).

NOTE: It is not necessary to define the Variable and Array


columns. Techlog identifies them automatically.

7. Click Load to the import buffer.

8. Click to import the data into the Project browser.

9. After data has been imported, click Delete to clear the


content of the import buffer.

10. Click Close to close the import buffer.

Techlog Fundamentals, Version 2012 51


Data Import and Export Schlumberger Internal Use Only

Lesson 2 DLIS File Import

There are two ways to import *.dlis data: File(s) import or


Selective DLIS import.

File(s) import (Figure 18) loads the header and the data, applies
the family assignment rules, and calculates statistics when
loading to the buffer.
© 2011-2013 Schlumberger. All rights reserved.

Figure 18 File(s) import dialog box

Selective DLIS import (Figure 19) loads the header into the
buffer and applies the family assignment rules (quick load). When
you transfer files to the Project browser, it loads the data and
calculates statistics.

Figure 19 Selective DLIS import dialog box

52 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

This type of import is useful when working with large files or when
you wish to view the content of the file. Imported data is displayed
in the import buffer where you can verify that all variables are
present.

After data is imported into the buffer, choose the data sets to be
imported into the project and click the green arrow to move
them into the Project browser (Figure 20). You can observe the
progress of the import in a Techlog window.

© 2011-2013 Schlumberger. All rights reserved.


Figure 20 Data import into the Project browser

Techlog Fundamentals, Version 2012 53


Data Import and Export Schlumberger Internal Use Only

Exercise 1 Importing DLIS Log Files

In this exercise, you load .dlis data into your project.

1. Select Home > Import .


2. In the import buffer, select Files(s) import from the drop-
down menu.

3. Click Open .
4. Choose the files listed in the \Techlog_2012\01 DLIS
directory and click Open. You now have five files in the
import buffer:
• Well1.dlis
• Well2.dlis
• Well3.dlis
© 2011-2013 Schlumberger. All rights reserved.

• Well4.dlis
• Well9.dlis.
5. The files are added as well names. Expand each well and
look at the data sets.
6. There is a problem with the name of the DATAFULL file in
Well 2. Remove the underscore (_) in the file name
a. Right-click on the data set.
b. Select Rename, or press F2.
7. Choose all the data sets named DATAFULL for all five wells.
TIP: Use the conditional selection to select only the
DATAFULL data sets.

8. Click the green arrow to import the data into the Project
browser.
9. Verify that your data was imported correctly by expanding the
wells and the data sets.
10. Click on a variable and view it in the Properties dock
window. The properties for each variable display.
TIP: The shortcut for viewing the Properties window is F4.

54 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

11. In the Project browser, note that variables display in black,


gray, or red.
• Black indicates a variable has a unit and has been assigned
to a family.
• Gray indicates the variable is missing a family or a unit.
• Red indicates the variable has no unit and no family
assigned to it.
This display helps you to harmonize and quality check the
data. (These topics are discussed later in the training.)

12. After you quality check the data, click Delete to clear the
content of the import buffer.

13. Click Close to close the import buffer.


TIP: If you click the X (in the upper right corner of the

© 2011-2013 Schlumberger. All rights reserved.


window) to close the import buffer, both the import
buffer and the Project browser window will close. To
reopen the Project browser and import buffer, right-
click Dock windows and select Project browser.

Techlog Fundamentals, Version 2012 55


Data Import and Export Schlumberger Internal Use Only

Lesson 3 LAS File Import

When importing *.las files, select File(s) import (Figure 21) from
the drop-down menu in the import buffer. All other steps in the
import process are identical to the procedure for importing *.dlis
data.
© 2011-2013 Schlumberger. All rights reserved.

Figure 21 LAS file import dialog box

56 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

Exercise 1 Importing LAS Files

In this exercise, you load the Hole Azimuth and Deviation surveys
into Techlog. These surveys are provided as .las files.

1. Select Home > Import .


2. Select File(s) import from the drop-down menu.

3. Click Open .
4. Choose these files listed under \Techlog_2012\02 LAS and
click Open.
• Well1.las
• Well2.las
• Well3.las
• Well4.las

© 2011-2013 Schlumberger. All rights reserved.


• Well9.las
5. Expand each well and view the data sets.

6. Choose the data set SURVEY for all five wells and click to
import the data into the Project browser.
This figure shows the Project browser after adding the
SURVEY files.

Techlog Fundamentals, Version 2012 57


Data Import and Export Schlumberger Internal Use Only

7. Verify that your data was imported correctly by expanding the


wells and the data sets. You can see that the SURVEY data
set has been added to each well.
This figure shows the Project browser after the SURVEY
data is imported.
© 2011-2013 Schlumberger. All rights reserved.

8. Click on a variable and view it in the Properties dock


window. The properties for each variable display.
Notice that some variables display in black, gray, or red.

• Black indicates a variable has a unit and has been assigned


to a family.
• Gray indicates the variable is missing a family or a unit.
• Red indicates the variable has no unit and no family
assigned to it.
9. Clear the content of the import buffer.
10. Close the import buffer.

58 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

Lesson 4 Text File Import

Text files are imported as *.las files using the File(s) import
command. Before *.txt files are added to the import buffer, they
display in the Data import wizard window (Figure 22). In this
window, you can verify that your data will be correctly imported.

The Data import wizard allows you to configure many


parameters.

• Dataset type (continuous data, point data, intervals)


• Specific lines from which to import
• Line for unit, if it exists
• Delimiter of the original file.

© 2011-2013 Schlumberger. All rights reserved.

Figure 22 Data import wizard for zones import

Techlog Fundamentals, Version 2012 59


Data Import and Export Schlumberger Internal Use Only

Exercise 1 Importing Stratigraphy Data from


a TXT File

In this exercise, you import the stratigraphy data for Well1, Well2,
Well3, Well4, and Well9. Before you start the exercise, you can
open the .txt file to review the data you are about to import, as
shown in the figure.
© 2011-2013 Schlumberger. All rights reserved.

1. Select Home > Import .


2. Select File(s) import from the drop-down menu.
3. From the folder \Techlog_2012\03 TXT, select the ZONES.txt
file to import. The Import Wizard window opens.
4. In the Property area, change the Dataset Type to Interval.
Notice that there are no units in this file.
5. Add the unit (FT) to the Reference variable.

60 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

6. Click Preview.
Your Data import wizard window should match this figure.

© 2011-2013 Schlumberger. All rights reserved.


7. Click Load to the import buffer.

Techlog Fundamentals, Version 2012 61


Data Import and Export Schlumberger Internal Use Only

8. Make a quality check of the data added to the import buffer.


© 2011-2013 Schlumberger. All rights reserved.

9. Click to import the data into the Project browser.


10. Clear the content of the import buffer.
11. Close the import buffer.
TIP: You can select multiple files to add to the import buffer.

Exercise 2 Importing the TOPS1 File

In the next exercises, you import three files. Because you can add
multiple files in the Techlog import buffer, you will do the final
import to the Project browser at the end of Exercise 3.

1. Select Home > Import .


2. Select File(s) import from the drop-down menu.
3. From the folder \Techlog_2012\Exercises\01 Import
Exercise\01 Import various test configurations\, select to
import the file TOPS1.txt. The Data import wizard window
opens.

62 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

4. In the Data import wizard window, define these parameters:


• Well name column
• Dataset name column
• Reference unit
• Dataset type (Interval).
Two settings are configured automatically:

• Variable name line is set to 1.


• Data import is done from line 2.
NOTE: These settings should be verified for any future files.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 63


Data Import and Export Schlumberger Internal Use Only

Exercise 3 Importing the TOPS2 File

In this exercise, you import the file named TOPS2.

1. Select Home > Import .


2. Select File(s) import from the drop-down menu.
3. From the folder \Techlog_2012\Exercises\01 Import
Exercise\01 Import various test configurations\, select to
import the file TOPS2.txt. The Data import wizard window
opens.
4. In the Property area, set the Zonation mode to zonation.
You now are able to select Top or Bottom in the table, as
shown in the figure in Step 5.

NOTE: The property Dataset type was automatically set to


interval.
© 2011-2013 Schlumberger. All rights reserved.

5. Define the Top and Bottom columns and verify that they have
the correct units.

64 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

In this exercise, there is no need to define the reference


curve. The Top variable will be used as a reference.

© 2011-2013 Schlumberger. All rights reserved.


6. Define the Well name column.
7. Define the Dataset name column in the Property area
(TOPS2). If no column is defined as Dataset name, you have
the option of entering a name.
8. Verify that Import from line is set to 3.
9. Click Load to the import buffer.
Red error messages display in the output dock window
during the import process.

Techlog Fundamentals, Version 2012 65


Data Import and Export Schlumberger Internal Use Only

10. Review the original file and make corrections as needed.


Notice that a dot is missing in line 26 of the original file.
Instead of displaying a depth of 10983.4, the depth is
displayed as 109834.

TIP: It is possible to edit the file that is currently loaded with


the wizard. Any modification performed (and saved) in
the original file will be immediately propagated in the
wizard after clicking Preview.

11. After saving corrections to the TOPS2.txt file, repeat Step 1


through Step 5 to import it.

Exercise 4 Importing the TOPS3 File

In this exercise, you import the file named TOPS3.


© 2011-2013 Schlumberger. All rights reserved.

1. Select Home > Import .


2. Select File(s) import from the drop-down menu.

3. From the folder \Techlog_2012\Exercises\01 Import


Exercise\01 Import various test configurations\, import the
file TOPS3.txt. The Data import wizard window opens.

66 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

4. In the Property pane, define Delimiter > Others as a ( ' )


separator and click Preview.
5. Set Keep consecutive separators to no and click Preview.
6. Add a unit (ft) to the Reference column.
7. Define the Dataset name as TOPS3.
8. Set the Dataset type as interval.
9. Import the data into the Project browser.
10. Clear the contents of the import buffer.
11. Close the import buffer.

Lesson 5 CSV Spreadsheet Import

Core data is imported as point data in *.csv format using the


File(s) import command. Display the Data import wizard to

© 2011-2013 Schlumberger. All rights reserved.


verify or change property settings.

NOTE: Excel files (.xls and .xlsx) are binary files and cannot be
imported using the ASCII import wizard. If you must
import Excel data in *.xls (MS Office 2003) or *.xlsx (MS
Office 2007 and 2010) formats, save the files in the *.csv
format, then import the .csv files into Techlog.

Exercise 1 Importing a CSV Spreadsheet

In this exercise, you upload core analyses in .csv format.

1. Open the folder \Techlog_2012\04 CSV and import the Well1


file. The Data import wizard opens.
2. Verify that these property settings are correct or make
changes accordingly:
• Set the Dataset type to Point Data.
• Set the Variable name line to 1.
• Set the Units line to 2.
• Set the Import from line to 3.

Techlog Fundamentals, Version 2012 67


Data Import and Export Schlumberger Internal Use Only

• Add the unit ft to the reference if it was not previously


added.
• Change the Comma delimiter to yes.
© 2011-2013 Schlumberger. All rights reserved.

After your point data is added to the import buffer, you should
see a display similar to the figure. The name of your point
data set should be MICP.

3. Repeat Step 1 and Step 2 to import Well2, Well3, Well4, and


Well9 MICP data.

Exercise 2 Importing Formation Pressure Data

In this exercise, you upload formation pressure data provided as


an Excel file.

1. Open the Excel file formation pressure.xlsx from the


\Techlog_2012\Exercises\01 Import Exercise\02 Tables and
spreadsheets\ folder and save it with the same name in a
comma delimited file .csv format.
2. Upload the .csv file into Techlog.
3. Set the Comma delimiter to yes.
4. Change the first column to be the reference.
5. Import the data into the import buffer only.
Notice that the curves were imported as array (vector)
data . This is done because in the original file, at least one
depth repeats itself.

68 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

6. Clear the contents of the import buffer.


7. In the import buffer, click on the word Datasets.
8. In the Properties window, under the ASCII import parameter,
select Array creation policy.
9. Choose the add an epsilon to the reference value option. This
option remains selected for any type of data.

© 2011-2013 Schlumberger. All rights reserved.


This configuration is not optimal for other types of data, such
as Capillary Pressure curves. Choosing the ask for each case
option could be useful for future import sessions.

10. Upload the .csv file into Techlog again.


Notice that this time the RFT variables are displayed with the
Point data icon .

11. Configure the Well name and Dataset name by right-clicking


and using the contextual menu.
12. Import the data into the Project browser.

Techlog Fundamentals, Version 2012 69


Data Import and Export Schlumberger Internal Use Only

Exercise 3 Importing a Thin Section Analysis


Table

In this exercise, you upload a different type of data: a thin section


description provided as a .csv file.

1. Select Home > Import .


2. Select File(s) import from the drop-down menu.
© 2011-2013 Schlumberger. All rights reserved.

3. From the folder \Techlog_2012\Exercises\01 Import


Exercise\02 Table and spreadsheets\, import the file Thin
section analysis.csv.
4. In the Data import wizard, set the variable name line
property of the original file to 3.
5. Click Preview. Notice that this file has no units.
6. Set the unit line property to 0.
7. Click Preview. Notice that, in this instance, the application
begins importing the file only from line 10.

70 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

8. Set the import from line property to 4 and click Preview.


9. To visualize additional lines in the lower table, increase the
number of available lines and click Preview.
10. Define the curve that will be the reference curve of the data
set.
11. Add units to the curves.
12. Enter a Dataset name.
13. Remove the Well name from column 1 and add the correct
well name.

Lesson 6 Image File Import

Image files can be imported using the Images import with


wizard command (Figure 23) in the import buffer.

© 2011-2013 Schlumberger. All rights reserved.


Figure 23 Images import with wizard command

In the Image import wizard window, you set parameters in the


Dataset information and Image information areas of the wizard to
determine how Techlog should read the file. Upon import, you
can either copy the actual file and place it in the project, or copy a
link to the location of the image.

Techlog Fundamentals, Version 2012 71


Data Import and Export Schlumberger Internal Use Only

The Image import wizard window (Figure 24) allows you to


choose and preview image files to import.
© 2011-2013 Schlumberger. All rights reserved.

Figure 24 Image import wizard for image files

Procedure 1 Importing Images

This procedure shows you how to load core data images into
Techlog.

1. Select Home > Import to open the import buffer.


2. Select Images import with wizard from the drop-down
menu.
3. Click Open and navigate to your image folder.
4. Choose all the images you wish to load and click Open. The
Image import wizard opens.
NOTE: Techlog allows you to import *.png, *.tif, *.jpg, *.bmp,
and *.gif image formats.

72 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

5. Enter a name using the correct naming convention.


You can enter the name or choose a predefined pattern. The
name of images file must comply with the naming convention
for images. For example, if your image is named
Well1_CoreImages_1567.png, the naming convention is
%WellName%_%DatasetName%_%DepthTop%

If the name of the file is more complex (for example, if the


core image file is CD10789 with 10789 as the top depth of
the core), you must type CD%DepthTop% with CD before the
% to make sure Techlog recognizes the depth automatically.

6. Copy images into the project by selecting the Copy all images
into the project check box.
If you do not select this option, a link will be created between
the variable and the actual image during the import process.

© 2011-2013 Schlumberger. All rights reserved.


TIP: If there are a lot of images to copy, the performance of
Techlog could be affected; select the Convert all images
into 8 colours bits check box.

7. In the Dataset information zone:


a. choose a proper unit
b. enter a Dataset name
c. enter a variable name.
8. Click Preview to view the correctly displayed depth
reference.
9. Click Load to the import buffer. The data set is now added
to the import buffer.

10. Click to import the data into the Project browser.

11. Click Delete to clear the contents of the import buffer.

12. Click Close to close the import buffer.

Techlog Fundamentals, Version 2012 73


Data Import and Export Schlumberger Internal Use Only

Exercise 1 Importing Core Images

Core images cannot be imported by dragging them into Techlog.


The data need to be imported using Image import wizard to be
sure Techlog puts the images at the correct depth. In this
exercise, you load some .png and .tiff core images into your
Techlog project.

1. Select Home > Import to open the import buffer.


2. Select Images import with wizard from the drop-down
menu.
3. Navigate to the folder \Techlog_2012\05 Core images PNG/
Well9/Daylight and choose all files.
© 2011-2013 Schlumberger. All rights reserved.

4. Click Open. The Image import wizard window opens.


5. Select the Copy all images into the project check box.
NOTE: You are importing the file, not creating a link to the
file.

6. In the Images information area, the Name model field


extracts information from the file name.
7. Scroll to the end of the file name list and locate Top Depth –
Bottom Depth, as indicated in the Name model field:
%DepthTop%-%DepthBottom%.

74 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

8. In the Dataset information area, choose ft from the drop-


down list in the Depth unit field.
9. Click Load to import buffer.
10. Load the second image data set by selecting Image import
with wizard from the drop-down menu in the Import
browser.
11. Navigate to the image folder \Techlog_2012\06 Core Images
TIF/Well9/UV and choose all files.
12. Click Open. The Image import wizard window opens.
13. Configure parameters to import *.tiff files.
14. Select the Copy all images into the project check box.
15. Verify the name model to be %DepthTop%-%DepthBottom%.
16. Because this core image data set is using Core Depth as a
reference, in the Dataset information area, enter the Depth

© 2011-2013 Schlumberger. All rights reserved.


name field CDEPTH and choose FT from the drop-down list
in the Depth unit field.

Techlog Fundamentals, Version 2012 75


Data Import and Export Schlumberger Internal Use Only

The table in the lower left corner shows you how the data is
stored (a data set with a link to the image at each depth). The
scale in the right lower corner lets you preview the images.

17. Review the depth table and note the empty intervals.
18. In the lower right corner of the window where a view of the
image is available, modify the zoom factor.
Each time you click Preview to apply a modification, the
scale is updated.

TIP: The Maximum interval option is ignored when the top


and bottom are available. If only tops are available,
Techlog runs a check on the difference between them,
then determines the maximum interval.

If the difference between tops is longer than the


maximum interval, the core length will be equal to the
© 2011-2013 Schlumberger. All rights reserved.

maximum interval. This prevents the core image from


being stretched between the two tops.

19. Click Load to the import buffer.


The data is now added to the import buffer. You can see the
DaylLight and UV data sets under Well9. Notice the different
references: MD for the DayLight data set and CDEPTH for
the UV data set.

20. Choose Well9 and click to import the data into the Project
browser.
21. Clear the contents of the import buffer.
22. Close the import buffer.

76 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

Lesson 7 XML File Import

XML files are data files that have been previously processed and
exported in Techlog. This format contains all the additional
information that a variable can carry, including an associated
palette and well color.

There are two ways of importing xml files into Techlog. Method 1
uses the import commands on the menu; Method 2 uses a drag-
and-drop function.

Procedure 1 Importing XML Files from the


Import Buffer

In this procedure, you import an .xml file created in Techlog using


the import buffer.

© 2011-2013 Schlumberger. All rights reserved.


1. Select Home > Import to open the import buffer.
2. Select File(s) import from the drop-down menu.

3. Click Open to choose the .xml file you wish to import. The
data you import are automatically loaded into the import
buffer.

4. Choose the data and click to import it into the Project


browser.

5. Click Delete to clear the contents of the import buffer.

6. Click Close to close the import buffer.

Techlog Fundamentals, Version 2012 77


Data Import and Export Schlumberger Internal Use Only

Procedure 2 Importing XML Files with a Drag-


and-drop Method

In this procedure, you import xml files using a drag-and-drop


method.

1. Drag your .xml file into the display area.


The files are parsed automatically in the import buffer,
because .xml is the Techlog native format.

Techlog XML data file is the preferred format when


exchanging data between Techlog users, because it
preserves all Techlog-specific settings (Families, History,
Well Color).

2. Choose the data and click to import the data into the
Project browser.
© 2011-2013 Schlumberger. All rights reserved.

3. Click Delete to clear the contents of the import buffer.

4. Click Close to close the import buffer.

78 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

Exercise 1 Loading the LQC data

In this exercise, you import an .xml file created in Techlog


containing Log Quality Control (LQC) data.

1. Drag the XML files from the \Techlog_2012\07 XML.xml


folder into the display area.
The LQC data set for the five wells is now in the import
buffer.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 79


Data Import and Export Schlumberger Internal Use Only

Notice that wells have a color and variables have a history as


shown on the History tab of the Properties window.
© 2011-2013 Schlumberger. All rights reserved.

2. Select all the wells by pressing Ctrl + A within the import


buffer.
3. Import the data into the Project browser.

80 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

4. Clear the content of the import buffer.


5. Close the import buffer.

Lesson 8 Time Data

In this lesson, you will learn how Techlog handles time data. In
the previous exercises, all the references were Measured Depth.
Sometimes you might have to upload data with a different
reference such as time data.

Techlog manages data with 16 significant figures (double


precision data). This allows it to support date-time data. A variable
is considered date-time data when its family is Date Time.

You can create a data set with a reference in date-time by


following a simple workflow within the Project browser or the

© 2011-2013 Schlumberger. All rights reserved.


Data editor. You also can import and save date-time data in a
Techlog project. All data processing tools (such as resampling,
combining or resizing data sets, and time shift) work with date-
time data.

In Techlog, a Date-time reference is stored as a number of milli-


seconds since January 1st 1900. For example, December 21st
1983, 21:26:11 is stored in the database as 2649878771116.07
ms.

You can load these date-time formats into Techlog:

• yyyy-MM-dd hh:mm:ss.zzz
• yyyy-MM-dd hh:mm:ss
• yyyy/MM/dd-hh:mm:ss
• yyyy/MM/ddThh:mm:ss
• dd/MM/yyyy-hh:mm:ss
• dd/MM/yyyy hh:mm:ss
• hh:mm:ss dd-MMM-yy
• hh:mm:ss/dd-MMM-yyyy
• hh:mm:ss.zzz
• hh:mm:ss

Techlog Fundamentals, Version 2012 81


Data Import and Export Schlumberger Internal Use Only

To upload other formats, go to the Import buffer Properties


window where you can add a specific date-time format that is not
handled by Techlog by default.

You will need to combine these expressions to import specific


date-time files.
Table 1: Expressions to Create Date-time Formats

Expression Output
h The hour without a leading zero (0 to 23 or 1 to 12 if
AM/PM display)
hh The hour with a leading zero (00 to 23 or 01 to 12 if
AM/PM display)
H The hour without a leading zero (0 to 23, even with
AM/PM display)
HH The hour with a leading zero (00 to 23, even with AM/
© 2011-2013 Schlumberger. All rights reserved.

PM display)
m The minute without a leading zero (0 to 59)
mm The minute with a leading zero (00 to 59)
s The second without a leading zero (0 to 59)
ss The second with a leading zero (00 to 59)
z The millisecond without a leading zero (0 to 999)
zzz The millisecond with a leading zero (000 to 999)
AP or A Use AM/PM display. AP will be replaced by either AM
or PM
ap or a Use am/pm display. ap will be replaced by either am
or pm

82 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

Exercise 1 Uploading Time Data

In this exercise, you upload a file containing time data. The


reference for this file is in milliseconds, a format that is recognized
by Techlog automatically.

© 2011-2013 Schlumberger. All rights reserved.


1. Drag the file 1_Well9_DateTime.las XML from the
\Techlog_2012\Exercises\01 Import Exercise\05 Time data
folder into the display area.
2. Import the data into the Project browser.
3. Clear the content of the import buffer.

Techlog Fundamentals, Version 2012 83


Data Import and Export Schlumberger Internal Use Only

4. Close the import buffer.


The DateTime data set is added to the Project browser.
Notice the reference, which is TIME with Date Time as the
family and ms as the unit.
© 2011-2013 Schlumberger. All rights reserved.

Exercise 2 Uploading Time Data with Time


Reference

In this exercise, you upload a second file containing time data as a


reference. If you drag this file into Techlog, the file will be
uploaded as any ASCII file. However, in the Project browser, you
can see that the time reference has no family. It will not load
correctly.

Furthermore, in the Project browser, the reference appears to


have no family and no unit. This indicates that the time format has
not been recognized by Techlog.

84 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

1. Open the file \Techlog_2012\Exercises\01 Import


Exercise\05 Time data\2_Well9_TimeData.asc in a text
editor.
The first column is your time data. The format is not in the list
of recognized formats. You will need to enter this specific
format in the Import buffer Properties window.

© 2011-2013 Schlumberger. All rights reserved.


2. Select Home > Import to open the import buffer.
3. In the Import buffer Properties window, enter the time date
format using the convention presented in Table 1 and shown
in this figure.

4. Drag the file 2_Well9_TimeData.asc into the import buffer.


5. In the Data import wizard, change the well name to Well9.
6. Click Load to the import buffer.
The import buffer displays the contents of the LAS file.

7. Import the data into the Project browser.


8. Clear the content of the import buffer.

Techlog Fundamentals, Version 2012 85


Data Import and Export Schlumberger Internal Use Only

9. Close the import buffer.


The TimeDate data set is added to the Project browser.
Notice that the reference time is assigned to the Date Time
family with ms as a unit.

Lesson 9 Well Identification Solver:


© 2011-2013 Schlumberger. All rights reserved.

Data Import under the Same


Name

The well identification solver is a useful tool when the names of


two wells are not identical due to a typing error, naming
conventions, or other actions that lead to a name mismatch.

Exercise 1 Importing Data with the Same


Name

In this exercise, you import data from one well to another well.
This is a useful process when the names of two wells are not
identical due to a typing error or other naming conventions.

You can import data under the same well by renaming each well
or you can use the Well Identification Solver.

1. Import the file \Techlog_2012\Exercises\01 Import


Exercise\04 Well identification solver\RUN1.las into the
Project browser.
2. Remove the RUN1 data from the import buffer.
3. Clear the contents of the import buffer.
4. Drag RUN2.las, RUN3.las, and RUN4.las into the import
buffer. Notice that the name of the well is slightly different for
each file.

86 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

5. In the import buffer, click on the word Datasets and view the
import properties. The second tab, Well Identification
Solver, is active by default.
6. Verify that the Enabled property is set to yes.

© 2011-2013 Schlumberger. All rights reserved.


On the left side there is a list of all wells in the import buffer;
on the right side there is a list of the wells that already exist in
the project.

7. Change the name of the well to Well20 to link the wells in the
buffer to the wells in the project.
8. Return to the import buffer and import the data.
9. Clear the content of the import buffer.
10. Close the import buffer.

Techlog Fundamentals, Version 2012 87


Data Import and Export Schlumberger Internal Use Only

Lesson 10 Data Export

Techlog export features allow you to export data to standard


formats, or connect to an external database.

Procedure 1 Exporting Data

In this procedure, you export objects from the Project browser

1. Click Project > Export to open the export buffer.


2. From the drop-down list, select the format in which you wish
to export the data.
© 2011-2013 Schlumberger. All rights reserved.

3. In the Project browser, select the objects that you want to


export and click .
You can export wells with zone and depth limitations. This
feature is available only with LAS 2.0 and 3.0 and TechCSV
formats. You can set the limits on the Limits tab in the
Properties window of the export buffer as shown in the
figure.

88 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

In the Properties window, you also can select the default null
values and create one or more .dlis files when exporting data
from several wells.

© 2011-2013 Schlumberger. All rights reserved.


4. Click Save and browse for an export folder.
The data will be exported in the file format that you select.

5. Click Delete to clear the content of the export buffer.

6. Click Close to close the export buffer.

Techlog Fundamentals, Version 2012 89


Data Import and Export Schlumberger Internal Use Only

Exercise 1 Exporting Data

In this exercise, you export the Caliper (CAL), Gamma ray


(GAMM), density (DENS), Neutron porosity (NEUT), and
Compressional slowness (SONI) data from the DATAFULL data
set for the wells 1, 2, 3, 4, and 9 that you loaded into your project.
However, you will export only ZoneD data.

1. Create a filter on the DATAFULL data set.


2. Select the CALI, DENS, GAMM, NEUT, and SONI variables
and create a conditional selection.
3. Create a filter.
© 2011-2013 Schlumberger. All rights reserved.

4. Select Home > Export to open the export buffer.


5. You will export this data with an LAS 2.0 format.
Select Las 2.0 (*.las) from the drop-down menu in the export
buffer.

90 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

6. Select all the data from the Project browser and click . All
of the data is now in the Export buffer window.
7. Open the Properties window for the export buffer.
8. Export data from the Stratigraphic interval D only.
a. Open the Limits tab.
b. For the Limitation parameter, select per zones.
c. For the Zonation parameter, select STRATIGRAPHY.
d. For the Top zone parameter, select ZoneD.

© 2011-2013 Schlumberger. All rights reserved.


TIP: For the Limitation parameter, you also can select to
export only a selected interval. To do this, enter the Top
and Bottom for the interval you want to export.

9. Add a property so that data is exported from ZoneD only.


a. Select DATAFULL from Well1.
b. Open the Properties window and right-click anywhere in
the Properties tab.

Techlog Fundamentals, Version 2012 91


Data Import and Export Schlumberger Internal Use Only

c. Select Add a property.


© 2011-2013 Schlumberger. All rights reserved.

d. In the Add a property window, enter these values to


define the property and click OK:
• Name: Interval Exported
• Value: ZoneD
• Unit: leave empty
• Description: Export was restricted to ZoneD.

TIP: You can add a property to any well, data set, or variable
from the Project browser by applying the same
method in the Properties window.

92 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

The new property now can be seen in the Properties


window. The modification has been made only for Well1.

© 2011-2013 Schlumberger. All rights reserved.


10. Click Save .
11. Choose to export one file per data set using the automatic file
name WellName_DatasetName [LAS Certified].
12. Save the files on your desktop.
Techlog creates five files (one for each well).

13. Open the Well1_DATAFULL.las file and note the parameter


Interval Exported.

Techlog Fundamentals, Version 2012 93


Data Import and Export Schlumberger Internal Use Only
© 2011-2013 Schlumberger. All rights reserved.

94 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Import and Export

Review Questions
• How can you load data from an Excel spreadsheet?
• Where can you find the import properties?
• How can you obtain header information while loading a .dlis
file?
• What does it mean when a variable appears in red?
• Can you export only a selected interval?

Summary
In this module, you were introduced to the Well Identification
Solver and learned about:

• importing

© 2011-2013 Schlumberger. All rights reserved.


• data files (.dlis, .las)
• spreadsheet files (csv, txt)
• image files
• XML Techlog files.
• exporting data from Techlog.

Techlog Fundamentals, Version 2012 95


Data Import and Export Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

96 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

Module 3 Variable Management


Variables are series of data (alphanumeric, scalar curves, or
vector arrays) arranged according to a chosen index or reference.
Upon import, each variable is assigned to a family using the
Family assignment rules tool. Each family has its own display
properties, regardless of the variable name.

For example, any curve assigned to the Bulk Density family


appears in a linear scale, using a red color between the limits of
1.95 – 2.95 g/cm3. If the curve has other units compatible with the
family's unit, an on-the-fly conversion is done and the display
respects the same limits. In this instance, the limits are between
1,950-2,950 Kg/M3.

Alias is a generic name for variables, but with an order of priority


that you can define.

© 2011-2013 Schlumberger. All rights reserved.


Learning Objectives
After completing this module, you will know how to:

• edit the Families database


• import and export families
• use the Family assignment rules tool
• work with the Alias system.

Techlog Fundamentals, Version 2012 97


Variable Management Schlumberger Internal Use Only

Lesson 1 Families Management

The family controls the display settings of all variables, regardless


of the variable name.

Families Database
To access the tools that allow you to change families in the
database, select the Data > Techdata > Families > Families
database (Figure 25).
© 2011-2013 Schlumberger. All rights reserved.

Figure 25 Menu to access the Families database

Figure 26 shows the Families database window that lists all


families in the database and the display settings for each family.

Figure 26 Families database window

98 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

You can see two tabs in the window: Families and Edit Families.
The Families tab displays the settings (for example, unit, min-
max, scale, and line color) corresponding to each family. The Edit
Families tab allows you to change these settings at three levels:
User, Project, or Company.

Procedure 1 Editing Family Settings

1. In the Techlog main window, select Data > Techdata >


Families > Families database. The Families database
window opens.

© 2011-2013 Schlumberger. All rights reserved.


Icons in the upper left portion of this window provide these
functions.

Add a family

Delete a family

Save your changes

Update the display

2. Choose the family to be edited.

Techlog Fundamentals, Version 2012 99


Variable Management Schlumberger Internal Use Only

3. Right-click and choose the level at which you want to edit the
family, User, Project, or Company. The Edit families tab is
activated.
© 2011-2013 Schlumberger. All rights reserved.

100 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

4. On the Edit families tab, select the family to edit and change
the settings in the Properties window. The display settings
available to modify for the family are shown in the figure.
NOTE: Permeability is assigned these attributes
automatically: a logarithmic scale, display color, line
type and thickness, wrap, and automatic palette
filling.

© 2011-2013 Schlumberger. All rights reserved.


5. Click to save the changes.

Techlog Fundamentals, Version 2012 101


Variable Management Schlumberger Internal Use Only

Export and Import Families


You can export the Families list to an Excel spreadsheet in *.csv
format, modify and add relevant information, then import the
revised list. Upon import, you are asked to define in which level
the revised list is to be saved: User, Project or Company
(Figure 27).
© 2011-2013 Schlumberger. All rights reserved.

Figure 27 Exporting the Families list in csv (Excel) format

Exercise 1 Editing Family Properties

In this exercise, you edit the properties of the Gamma Ray family.

1. Select Data > Techdata > Families > Families database to


open the Families database.
2. In the Families database window, scroll through the
Families list and locate the Gamma Ray family.
TIP: Press a letter on the keyboard that matches the first
letter of the name you wish to locate. In this instance,
press G to go directly to this family.

3. Select the family Gamma Ray / Gamma Ray and view its
display options in the Properties window.
The displayed properties have these values:

• LogView color: Black


• Limits: 0 -150
• Baseline: 75 gAPI

102 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

• Baseline fill: Yellow/Brown.

4. Edit the display by right-clicking on the family and selecting


Edit the family > Project. The Edit Families tab opens.

© 2011-2013 Schlumberger. All rights reserved.


5. Change these settings in the Properties window:
• LogView color: Green
• Area fill type: None

6. Click to save and validate these modifications.


Notice that the modified items are now saved in the Project
level.

Techlog Fundamentals, Version 2012 103


Variable Management Schlumberger Internal Use Only

7. Drag the variable into a LogView layout and view the revised
display.

8. Repeat the process for the same family, but this time, modify
© 2011-2013 Schlumberger. All rights reserved.

the display properties at the User level by selecting Edit the


family > User and save your changes.
9. In the Edit families window, click on one of the levels: User,
Project, Company, or Techlog.
10. View the Properties window. The priority order for the
display settings is User first, then Project, then Company,
and then Techlog, as shown in the figure.

Rules Activation and Deactivation


In the Edit families window, you can activate or deactivate the
rules for any level. When you deactivate a level, you do not use
the settings at that level. Instead, you use the settings for the next
level down. Deactivating a specific level is useful when you need
to generate a report or other specific output.

104 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

For example, Gamma ray displayed with Techlog settings is


always displayed with a baseline value of 75 for the area fill. If you
have no need for the settings, you can remove them from a
baseline in the User level.

Because you can use your own display settings, identical data can
be displayed in different ways. To maintain continuity, use project
settings instead of your personal settings so that all plots in the
project are harmonized. The same logic follows for the Company
level.

Exercise 2 Creating a New Family

You can create a new family at any level.

1. In the Edit families tab, select one level: User, Project,


Company, or Techlog.

© 2011-2013 Schlumberger. All rights reserved.


2. Click Add .
3. In the Family build window, select the Main family, Family,
and Level in which to save the new family and click OK.

TIP: Alternatively, you can add a new family to the


predefined list of Main families.

4. Go to the Properties window and define the display settings


for the new family.

5. Click to validate and save the changes.


6. Assign a curve to the new family.
Right-click on a curve in the Project browser and assign it to
the new family using the contextual menu that appears.

7. Display the curve in a layout and verify that the settings are
correct.

Techlog Fundamentals, Version 2012 105


Variable Management Schlumberger Internal Use Only

Exercise 3 Using the Family Assignment


Rules Tool

Upon import, variables are assigned to specific families


automatically. This is done on the fly according to the variable
name and unit by means of the Family Assignment Rules tool.

In the data set DATAFULL, some curves are not assigned to a


family. They appear in red. This means that the curve name did
not match the existing rules.

In this exercise, you use the Family Assignment Rules tool to


assign the variables C_PHI (Core Porosity) and CKK (Core
Permeability) to the correct families.

1. Select Data > Techdata > Families > Family assignment


rules.
© 2011-2013 Schlumberger. All rights reserved.

This opens the list of all the rules that were applied.

2. Use the Quick Search tool to focus on a family of interest. In


this instance, view all the rules in the Core Porosity family.
Notice that the variable C_PHI was not assigned
automatically to this family.

3. Create a new rule by choosing the list level in which the new
rule will be located in the drop-down menu. The default level
is All. Change the level to Project.
Notice that all of the rules disappear, because they all belong
to the Techlog level. Also, the icons that were grayed out are
now visible.

106 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

4. Click Add to create a new rule.


5. In the Variable name and unit dialog box, define these
values:
• Main family: Core Analysis Routine
• Family: Core Porosity
• Variable: C_PHI.
• Unit: If you leave the unit as an asterisk (*), the unit is a wild
card. This means that the rule will be applied on only the
variable name and not its unit.

© 2011-2013 Schlumberger. All rights reserved.


6. Click OK.
7. Before applying the rule, test which variables will be affected
as a result of this new assignment rule.
a. Select the Test only option and click Apply to all
variables.
b. View the list of variables in the Output dock window.
8. When you are satisfied with the results, clear the Test only
option and apply the rule.
Notice that the color of the variable changes.

9. Select the variable C_PHI in the Project browser. The


properties of this variable show that it is assigned to the Core
Porosity family.

Techlog Fundamentals, Version 2012 107


Variable Management Schlumberger Internal Use Only

10. Take another look at the list of all of the rules that assign a
curve. A new rule appears that has priority above all other
rules.
NOTE: It is possible for two or more rules to contradict each
other. Should this be the case, the rule highest in the
list will be applied first.
© 2011-2013 Schlumberger. All rights reserved.

11. Repeat Step 3 through Step 10 for the variable named CKK
and assign it to:
• Main family: Core Analysis Routine
• Family: Core Permeability.
The family assignment rules list also can be exported to
Excel, modified, and imported.

108 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

Lesson 2 Aliases Management

Aliases are generic names of variables, with an order of priority


that you can define. The priority is defined according to the level of
the alias (User, Project, Company, or Techlog) as well as within
each level.

Aliases Database
To access the Aliases database (Figure 28), select Data >
Techdata > Aliases > Alias database.

© 2011-2013 Schlumberger. All rights reserved.


Figure 28 Accessing the Alias database

This window displays a list of the alias databases in the Techlog


folder (Figure 29). From the Aliases database you can take these
actions.

Validate and save modifications

Add an alias from the selected level: User, Project, or


Company
Delete an alias from the selected level: User, Project, or
Company
Increase or decrease the priority of a variable

Update the display

Techlog Fundamentals, Version 2012 109


Variable Management Schlumberger Internal Use Only
© 2011-2013 Schlumberger. All rights reserved.

Figure 29 Alias list under the Techlog folder

Exercise 1 Adding a New alias

In this exercise, you add a new alias in the Alias database.

1. Select Data > Techdata > Aliases > Alias database.

2. In the Alias database window, click Add .


3. In the Alias creation window, enter these values and click
OK.
a. Name the alias Best_GR.
b. Assign Gamma Ray to the Main family and the Family.
c. Define the alias to be at the Project level.

You now have a new alias.

110 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

4. Assign the variable names that will be used with this alias.
a. In the Aliases database window, choose the Alias name
BEST_GR and click Add .
b. Add these names to the list:
• GR*
• GR_0*
• GR_R*
• GAM*

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 111


Variable Management Schlumberger Internal Use Only

5. Arrange the list in your preferred order of appearance, which


also will be the order of priority.
© 2011-2013 Schlumberger. All rights reserved.

6. Click to validate your modifications.


7. Open a multi-well histogram and use the alias BEST_GR by
toggling ON Alias .

8. Select Wells 1 and 9.


9. Create a filter and then a conditional selection for the
DATAFULL data sets, then a second filter on these data sets.

112 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

10. Drag the data set into the Wells pane of the histogram
window.
Notice that the list of available variables corresponds to the
priority list you defined in the Alias database.

11. Open a second multi-well histogram, but, this time, choose


the Gamma Ray family and compare the results.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 113


Variable Management Schlumberger Internal Use Only

The first figure shows a multi-well histogram using the


BEST_GR alias; the second figure shows a multi-well
histogram using the Gamma Ray family.
© 2011-2013 Schlumberger. All rights reserved.

114 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

Exercise 2 Using the Alias Inventory

The Aliases inventory window allows you to list all of the aliases
in the project. If you need to create a data set (for example, LQC)
that will contain the same set of curves for each selected well, you
can do it automatically using the Alias inventory window.

1. Select Data > Techdata > Aliases > Alias inventory.


The Quick data mining window opens and displays the
Alias inventory table.

© 2011-2013 Schlumberger. All rights reserved.


2. Click .
The Aliases selection window opens. All of the aliases that
exist in the Project browser are listed in this window.

Techlog Fundamentals, Version 2012 115


Variable Management Schlumberger Internal Use Only

3. Select the aliases you want to display on the table and click
OK. The selected aliases are now displayed in the Quick
data mining table.
Using this dialog box, you can create Log Quality Control
(LQC) data sets.

Exercise 3 Creating LQC Data sets

In this exercise, you create a Log Quality Control (LQC) data set
using the Alias Inventory tool.

1. Select Data > Techdata > Aliases > Alias inventory. This
opens the tool and lists all the aliases that exist in the
Project browser.

2. Click to include these aliases in the new data set and click
OK.
© 2011-2013 Schlumberger. All rights reserved.

• DEN
• GR
• DT
• NEU
NOTE: This step reduces the list to these four aliases only.

3. For each well, choose the curves to be included.

116 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

4. In the Properties window, under Aliases inventory


selection, verify that the property Keep the original variable
name in the harmonized data set is toggled to yes.

© 2011-2013 Schlumberger. All rights reserved.


5. In the Aliases inventory, click the Build harmonized dataset
icon.

Techlog Fundamentals, Version 2012 117


Variable Management Schlumberger Internal Use Only

6. In the Harmonized dataset creation window, enter the


information shown in the figure and click OK to create the
harmonized data set.

For each well, a new data set is created in the Project


browser using the selected curves.
© 2011-2013 Schlumberger. All rights reserved.

Review Questions
• What is the difference between families and aliases?
• What is the purpose of the Family assignment rules tool?
• Can you create new families?
• What is the use of having different levels of family
assignment rules (user, project, or company)?

118 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Variable Management

Summary
In this module, you learned about:

• editing the Families database


• importing and exporting families
• using the Family assignment rules tool
• working with aliases.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 119


Variable Management Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

120 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only References Management

Module 4 References Management


The Reference dataset tool creates correspondences between
all the references of your well such as Measured Depth, Core
Depth, True Vertical Depth, and Two-way time. The reference
data set is mandatory to:

• easily switch between references in a LogView (from MD to


TVDSS for example)
• display 2D trajectory or 3D view
• use modules such as FPress, SHM, and Geophy in which a
relationship between the various references available is
mandatory.

© 2011-2013 Schlumberger. All rights reserved.


Figure 30 Reference dataset tool

Learning Objectives
After completing this module, you will know how to use:

• the deviation survey data to calculate TVD, TVDSS,


TVDBML, X and Y OFFSETs
• the Reference Dataset tool to create an Index data set.

Techlog Fundamentals, Version 2012 121


References Management Schlumberger Internal Use Only

Lesson 1 Index Data Set

Within a single well, data sets could have different references,


such as Measured Depth, True Vertical Depth, and Two-way time.
The Index data set creates a correspondence table using the
reference of each data set to link all data sets within a well
together and to plot all data irrespective of their sampling system.

Without the Index, data cannot be displayed in 3D plots or in such


modules as Formation Pressure and Pore Pressure Prediction.

Figure 31 illustrates the variety of depth measurements for both


onshore and offshore wells, including these important
measurements:

• KB: Kelly Bushing


• TVD: True Vertical Depth
© 2011-2013 Schlumberger. All rights reserved.

• TVDBML: True Vertical Depth Below Mudline


• MD: Measured Depth (Length of wellbore along path)
• TVDSS: True Vertical Depth Sub-Sea measured from the
KB.

Onshore Offshore

KB

Elevation KB = Elevation
Ground Level
TVDBML

Water Depth
TVD

TVD TVDBML TVDSS


MD

Figure 31 Well schematics with different depth measurements

122 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only References Management

Lesson 2 TVD Computation

The first step in creating the Index data set is to compute the true
vertical depth (TVD) from the deviation survey. This application is
called TVD computation and uses deviation survey data to
calculate TVD, the offset of the well, and several additional
references.

The index reference data set is built from the deepest to


shallowest values from all of the measured depth curves in all of
the data sets. The lowest sampling rate from all of the data sets is
used to build the MD curve for the index set (if a curve is set to
Ignore, it is ignored).

Procedure 1 Computing Depth Measurements

© 2011-2013 Schlumberger. All rights reserved.


This procedure shows you how to compute the TVD, TVDSS, and
other measurements from a survey data set.

1. Select Data > Techdata > Reference and coordinates >


TVD computation.
2. In the Data source selection window, choose the data
source to be used for Measured depth, Hole Deviation, and
Hole Azimuth.
NOTE: In the Input(s) (family, alias or variable) selection
window, a white cell in the Data type assignment
column indicates that this input is mandatory; a gray
cell indicates that the input is optional.

3. Click Create.
4. Drag the survey data sets into the Datasets side box.
5. Input variables will be selected according to the data source
you chose. If needed, adjust the variables selected.
6. In the table, adjust the Elevation and Water Depth
parameters. Leave the Method set to minimum curvature
and click Apply.

Techlog Fundamentals, Version 2012 123


References Management Schlumberger Internal Use Only

7. Click Yes to confirm that you want to create an Index data


set.
For each well used as input, Techlog creates a data set
named TL_Wellpath that contains the TVD, TVDSS, Dog Leg
Severity, and an Index data set.

Exercise 1 Running a TVD Computation and


Creating the Index Data Set

In this exercise, you compute the TVD from deviation survey data
for the Wells 1, 2, 3, 4, and 9. You also will create the Index data
set.

1. Select Data > Techdata > Reference and coordinates >


TVD computation.
2. In the Data type assignment window, choose which
© 2011-2013 Schlumberger. All rights reserved.

mnemonics that you wish to use for Measured Depth, Hole


Deviation, and Hole Azimuth inputs (mandatory inputs).
3. Choose the appropriate families (Measured Depth, Hole
Deviation, and Hole Azimuth), as indicated in the figure and
click Create. An empty True Vertical Depth window opens.

4. (Optional) If the well is vertical, select the Vertical well-


without survey option. Measured depth is the only mandatory
input for this option.
5. Create a Conditional selection to select all the surveys from
the Project browser (well surveys are present only for Wells
1, 2, 3, 4, and 9).

124 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only References Management

6. Drag the deviation survey data set from the Project browser
into the left side of the True Vertical Depth window on the
Wells tab.

A line for each well appears along with additional


parameters. The parameters are read directly from the well

© 2011-2013 Schlumberger. All rights reserved.


Properties window.

In this example, Well1 appears to have an elevation of 90


feet. Elevation, water depth, and other parameters are
populated automatically if these parameters are present in
the well properties.

TIP: You can check these parameters in the well Properties


window.

7. Because the five wells are offshore, enter 1,000 ft in the


Water Depth column and click the right mouse button to fill up
or down.
8. Scroll across to the Method field on the right side of this
parameters line.
9. Use the drop-down options to change the method used to
calculate the TVD curve and sampling rate of the new data
set.
10. Click Apply.
A confirmation dialog box appears giving you the option to
create an Index data set automatically. Techlog can create
an Index data set automatically if one does not exist in your
well.

Techlog Fundamentals, Version 2012 125


References Management Schlumberger Internal Use Only

11. In the confirmation dialog box, click No.


New data sets named TL_WellPath and Index are created
under each well in the Project browser.

Each TL_WellPath data set contains

• MD: Measure Depth


• BOREHOLE_AZIMUTH
• BOREHOLE_DEVIATION
• DL: Dog Leg Severity
• THL: True Horizontal Length
• TVD: True Vertical Depth
• TVDBML: True Vertical Depth Below Mudline, measured
from the earth's surface
© 2011-2013 Schlumberger. All rights reserved.

• TVDSS: True Vertical Depth Sub-Sea measured from the


KB
• XOFFSET: Offset in the X direction from the well position,
measured from sea level
• YOFFSET: Offset in the Y direction from the well position.
TIP: You can modify the names in the properties of the
method.

126 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only References Management

12. Check your results using the Data editor by dragging the
TL_WellPath data set into a Data editor window.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 127


References Management Schlumberger Internal Use Only

Lesson 3 Index Data Set Creation

The Index data set creates a correspondence table using the


reference depth of each data set. This step is necessary to link all
data sets within a well. Without an Index data set, you cannot
display items in 3D, display 2D plots according to various
references, or work with specific modules.

As you have seen in Lesson 2, Exercise 1, you have the option to


automatically create the Index data set after your TVD
computation.

To work with all of the Techlog modules or to use simple tools


such as LogView efficiently, you must have an Index data set.
This Index data set (also called a reference data set) is a
correspondence table between all of the references of your well,
such as Measured Depth, Core Depth, TVD, and Two-way time.
© 2011-2013 Schlumberger. All rights reserved.

The automatic Index data set created during the TVD computation
does not include references like Core Depth or Two-way time.

TIP: Why do I need an Index data set if I already have a


WellPath data set?
The Index data set is a correspondence table between all
the references of the well. This includes TVD, TVDSS, and
other information in the WellPath data set, in addition to
non-depth related references, such as Two-way time
(TWT) and drilling date time.

NOTE: To create a correspondence between two references,


both references must be present in the same set. This
also means that every time you upload a new data set in
a well, you will need to re-create the Index data set.

128 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only References Management

Exercise 1 Creating an Index Data Set

In this exercise, you create the Index data set manually.

1. Select Data > Techdata > Reference and coordinates >


Create Index set….
2. Drag one or more data sets into the Datasets navigation
pane. For this exercise, use Well1, Well2, Well3, Well4, and
Well9.
NOTE: All depth measurements are displayed in the
corresponding column.

© 2011-2013 Schlumberger. All rights reserved.


3. For each data set, choose the curves to use in the Index data
set (MD and DEPTH in this case) and click Apply.

Techlog Fundamentals, Version 2012 129


References Management Schlumberger Internal Use Only

A new data set named Index is generated from this


operation. It comprises all the depth variables from the data
sets present in all wells used in the process.
© 2011-2013 Schlumberger. All rights reserved.

4. The Index correspondence table can be displayed and


checked using the Data editor. Check your results by
dragging the Index data set into the Data editor window.

130 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only References Management

Review Questions
• What are the mandatory inputs to calculate TVD?
• What is the tie-in point?
• In which cases will you need an Index data set?

Summary
In this module, you learned about using:

• deviation survey data to calculate TVD


• the Reference Dataset tool to create an Index data set.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 131


References Management Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

132 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Module 5 LogView
LogView is the Techlog tool that allows you to display any
variable present in the Project browser. The actions available in
LogView are classified by the type. The actions available to you in
the dynamic toolbar depend on the object you select. The fixed
toolbar and mouse mode always provide you with the same
actions.

Learning Objectives
After completing this module, you will know how to:

• configure the appearance of LogView


• create plots in a track
• save and apply a layout.

© 2011-2013 Schlumberger. All rights reserved.


Lesson 1 LogView Interface

LogView can display any type of data including log, zone, core
image, seismic, array data, and core measurements.

Figure 32 LogView under the Plot tab

To display data, drag one or more variables from the Project


browser into a LogView window (Figure 33).

Techlog Fundamentals, Version 2012 133


LogView Schlumberger Internal Use Only

The variables for each family display according to the parameters


set in the Families database. These settings can be viewed in the
Properties window.
© 2011-2013 Schlumberger. All rights reserved.

Figure 33 Drag variables from the Project browser into the


LogView window

134 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

TIP: If you do not see the menu bar in your log header, click
under the Help icon on the top right corner of the log.

© 2011-2013 Schlumberger. All rights reserved.


Figure 34 Menu bars in LogView

Figure 35 Dynamic toolbar common functionalities

Techlog Fundamentals, Version 2012 135


LogView Schlumberger Internal Use Only

In addition to changing the curve color and thickness, tabs in the


Properties window (select an object and press F4) allow you to
change properties such as the scale of the plot, the datum, and
the reference depth.

NOTE: Keep in mind that every object has its own properties
that you can modify from the Properties window
(Figure 36).
© 2011-2013 Schlumberger. All rights reserved.

Figure 36 Examples of Properties windows for a few LogView


objects (Multi-well layout, Ordinary track, Variable,
Bi-color area fill)

The zoom and scale settings are managed with the mouse:

• To change the layout scale, hold the Ctrl key and move the
scroll wheel.
• To zoom in and out, move the mouse up or down while
holding down the scroll wheel. If your mouse does not have a
scroll wheel, hold down the Alt key and the left mouse button
while moving the mouse up or down.
• To change track zoom factor, select a track and press Ctrl +
Shift while moving the scroll wheel.

136 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

To improve a layout, many options are available in the LogView


Properties window, the Variable Properties, and LogView
toolbars (refer to the user guide for more information).

Variable Gives you access to variables from a data set


management according to a family or alias.

Types:

• Variable management: Displays all


variables from the current well with the
exact variable name. The variable of the
equivalent data set with the same name in
the selected wells are searched (for
example, LQC for the template well and
LQC for the well where the template is
applied). In the wells, if the data set does
not exist or has a different name, all wells

© 2011-2013 Schlumberger. All rights reserved.


are checked to find a variable with the
same name.
• Variable with wildcard management:
Searches for the variable with the same
name regardless of the data set in the
selected wells. You can define an
expression to enlarge the search (for
example, to allow a suffix on the variable).
Depending on the expression you enter,
all of the curves that match this expression
(for example, the expression NEUT* to
find NEUT_1) are displayed. The default
sorting is all of the curves from the exact
set first, then all other curves matching
this expression from outside this set.
• Family management: Displays the first
variable associated to the template family
in the new layout regardless of the data
set name. Use this level when there is
only one variable per family per well.
• Alias management: Displays the alias with
the higher level if you decide on a
hierarchy within the well. If not, the first
alias that corresponds to the template is
selected.

Techlog Fundamentals, Version 2012 137


LogView Schlumberger Internal Use Only

Variable Allows you to change the appearance of the


appearance variables. Choose the variables (they then will
appear in red) and go to the Properties
window to adjust the parameters: horizontal
and vertical axes limits, variable position,
boundaries, curve color, line thickness, unit,
and connection type.
Repeated Displays the same variable in a track multiple
variable times, which is particularly useful to simulate
display seismic traces with a repeated display of
synthetic logs.
Wrap display Displays the values of a variable not visible in a
track.
Text mode Displays text values of a variable in a track.
Multiple Applies a modification to multiple variables at
© 2011-2013 Schlumberger. All rights reserved.

variable the same time.


appearance
modification These properties can be modified
simultaneously: Color, Font, Type, Thickness,
Connection, Marker (type and size), Scale, and
Type of Limits (Mnemonic, User, and Variable).
Reverse Inverts variable boundaries.
variable
boundaries
Variable Inserts a color filling between a variable and its
filling and right or left limit; inserts shading between the
shading two curves.
Baseline Modifies track appearance.

Adjust the zoom factor, display or do not


display zones, modify the background color of
the track and its width, insert a track name in
the header, adjust the number of vertical lines,
select the color and thickness of vertical lines
and their scale (linear or logarithmic).

138 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Grid As many as three grids can be displayed in a


increment track: the main reference grid, a secondary
modification grid, and a tertiary grid.

Each has a user-defined increment which


allows you to capture a greater or lesser
amount of detail from the variables displayed.
Save layout Saves a LogView layout and its properties and
and layout retrieves it later. Saved layouts are stored in
properties the Project browser under Layouts.
Apply layout Allows you to use a layout set up in LogView
and for a particular well as a model for other wells.
properties to The new wells will display the same variables,
other all of which create a display using the same
datasets/ settings as those of the original layout.
wells

© 2011-2013 Schlumberger. All rights reserved.


Lesson 2 LogView Plots

In this lesson, you will build the LogView plot (Figure 37) using a
variety of tools available in Techlog.

This is a self-guided exercise, so only the first track will be


described to you in a step-by-step manner. For the others, you will
need to refer to the procedure for each track and then create the
information required in the track by working through the exercises.

You will begin by building a simple track. You then will learn about
the other tools in Techlog as you build and modify other tracks to
create a complex LogView plot.

As you build the full LogView plot, you will learn the details of how
to control the display of information in the LogView plot tracks,
including:

• displaying log data in a track


• checking and changing variables
• changing horizontal scales
• modifying the palette
• creating a new reference

Techlog Fundamentals, Version 2012 139


LogView Schlumberger Internal Use Only

• creating zones
• creating a data set for all the data in your LogView plot.
NOTE: You will apply this layout to other wells in a later
exercise, so you must build it accurately.
© 2011-2013 Schlumberger. All rights reserved.

Figure 37 Example of a LogView plot that you will create

Track Data
The first step in creating your LogView plot is to add log data.
Exercise 1 helps you to add log data to Track1. You then can add
additional tracks and data to the plot.

140 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Procedure 1 Inserting a Track

In this procedure, you will learn how to add, move, and delete a
track.

1. Go to the Insert menu.


2. Select the type of track you want to add.
Depending on the type of data you want to display, you can
choose from Normal track, Reference track, Array creation
track, or Zonation track.

3. Hover the mouse over the right border of a track to resize it.
Alternatively, you can enter a fixed Track size value in the
track Properties window under the Track width option.

4. Move a track by selecting it and clicking the left or the right


arrows on your keyboard. When a track is selected, it

© 2011-2013 Schlumberger. All rights reserved.


appears with a light red background color.

TIP: To move a variable, use the same principle: select a


variable and move it with the left or the right arrow of
your keyboard.

5. Delete a track by selecting the track and clicking Delete.


TIP: To delete a variable, select the variable and click
Delete.

Techlog Fundamentals, Version 2012 141


LogView Schlumberger Internal Use Only

Exercise 1 Displaying Caliper Gamma Ray


Sonic Data in Track 1

In this exercise, you create Track 1 in your LogView.

1. Open LogView by selecting Plot > LogView.


2. Choose the DATAFULL data set for Well9 and create a filter
on it.
3. Choose the variable CALI from DATAFULL.
4. Drag CALI into the LogView window.
5. Hold down the Ctrl key and choose GAMM, SONI, and
BS_DK.
6. Drag them into the CALI track.
7. Zoom in and out by pushing on the scroll wheel and moving
the mouse.
© 2011-2013 Schlumberger. All rights reserved.

8. Stretch and squeeze the LogView image by holding down


the Ctrl key, pushing on the scroll wheel, and moving the
mouse.
9. Select the SONI curve by clicking on it (you can select the
curve in the track or in the variable header). Notice that when
the curve is highlighted, it turns red with dashed lines.
10. Check the properties of the SONI curve in the Properties
window (F4).
11. Change the color of the variable.
a. On the Display options tab, click Color.
b. Select a dark purple.
12. In LogView, select the BS_DK and CALI curves.

142 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

13. In the LogView menu, select Insert > Area fill… > Between
the variables or right-click and select Insert area fill
between the variables.

© 2011-2013 Schlumberger. All rights reserved.


A bi-color area fill is inserted automatically between the two
selected variables.

14. In the variable header, click on color fill and modify the colors
in the Properties window.
a. Scroll down to Bi-color and change the color by clicking on
the Color box.
b. Select the correct colors to have the washout in blue and
the mudcake in brown.
15. In the Properties window, activate the Opacity option.

Techlog Fundamentals, Version 2012 143


LogView Schlumberger Internal Use Only

16. Enter Mudcake/Washout in the Name property.


© 2011-2013 Schlumberger. All rights reserved.

Your first track is ready.

17. Save the track as a Techlog template so you can use it in


another exercise.
a. Select the track.

144 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

b. Right-click on the track and select Save the tracks as


a template….

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 145


LogView Schlumberger Internal Use Only

c. Select Project as the level, enter


CALIPER_GAMMARAY_SONIC as a name, and then click
OK.
© 2011-2013 Schlumberger. All rights reserved.

Your track is now saved in your Project browser under the


Tracks template folder.

Variable Management
The template you are creating will be used for other wells.
However, some variables might have a different name.

Notice that none of the data sets contains a variable named LLD,
except for Well9. However, Wells1, 2, 3, and 4 have the variable
DEPR in DATAFULL, and both LLD and DEPR are assigned to
the Deep Resistivity family. This is where variable management
becomes important.

NOTE: If the variable you select is not found, its name appears
in the header as in the template, but the track is empty in
the layout. This is default mode.

146 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Procedure 2 Changing the Variable Management


Type in LogView

This procedure shows you how to select and apply the type of
variable management for a track. The options are variable
management, variable management with wildcard, family
management, and alias management.
1. Select the variable in the LogView layout.
2. In the Properties window (F4), select the Limits tab.
3. Go to the Variable management field to change the Type
property value.

Exercise 2 Checking the Variable Management


Type for Track 2

© 2011-2013 Schlumberger. All rights reserved.


In preparation for the upcoming exercises, ensure that the
variables are set properly for Track 2 in the LogView plot.

1. In the LogView menu, select Insert > Normal track to


add Track 2 for resistivity data.
2. Select the LLD, LLS, and MEDR variables in the LogView
layout.
3. Change the Type property to family.

Variable Scales
All variables have scales that you can modify. The Horizontal axis
properties provide three types of limits for you to choose to control
the variable scale.

• Family: Limits are read from family settings. You cannot


customize them from the LogView plot.
• Variable: The limits are defined from the minimum and
maximum values of the variable.
• User: You can manually set the limits for the track scale.

Techlog Fundamentals, Version 2012 147


LogView Schlumberger Internal Use Only

Procedure 3 Managing the Horizontal Scale

Family settings define default variable limits. This procedure


shows you how to change the horizontal scale for a variable.

1. Select the variable in the LogView layout.


2. In the Properties window, open the Limits tab.
3. Go to Horizontal axis properties and select Variable or User.

Exercise 3 Changing the Horizontal Scale for


Density and Porosity Log Data in
Track 3

In this exercise, you change the horizontal scale for density and
porosity in Track 3.
© 2011-2013 Schlumberger. All rights reserved.

1. Add Track 3.
2. Add density and porosity log data to the track.
3. Modify the C_PHI scale to be compatible with the NEUT log.
4. Explore the PEF and DRHO variables Properties window to
create a partial track.
5. Insert a yellow area filling between NEUT and DENS.
6. Save the track as a template.

Palette Editor
You can use the Palettes dock window to:

• select a palette
• modify boundaries and color dispersions (the boundaries
represent the limit values)
• use the palette in layouts, crossplots (log-log, array-array,
3D), spectrum analyzers, histograms (variable vs. array and
3D Vue).
You can right-click on the drop-down menu to:

• Save : Save the current palette with the displayed


boundaries and cutoff.

• Create : Create a new palette.

148 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

• Delete : Delete the current palette.

• Edit : Edit the current palette.


You also can open the Palette editor to edit a palette by double-
clicking on the yellow star from the drop-down menu.

© 2011-2013 Schlumberger. All rights reserved.


The Palette tab displays the information from the Palettes dock
window including interval limit values, number of intervals, and
type of scale. The Palette editor allows you to customize the
palette by:

• defining boundaries and intervals


• adding patterns and text
• customizing colors, palette, or interval gradient.

Techlog Fundamentals, Version 2012 149


LogView Schlumberger Internal Use Only

Procedure 4 Changing the Palette

When you drag the VSH_GR variable (or the FACIES04 variable)
into LogView, Techlog automatically assigns it the palette that is
defined by the Family variable. This procedure shows you how to
change this palette.

1. Ensure that the Palettes dock window is available in your


Techlog display.
2. Drag the VSH_GR variable into a LogView layout.
3. Select Object Area fill with baseline.
4. Go to the Palettes dock window.
5. From the Palette tab drop-down menu, select the palette you
want to use. Observe the results in the layout.
NOTE: Every predefined palette has a lower boundary value
© 2011-2013 Schlumberger. All rights reserved.

and an upper predefined value.

6. Set the lower and upper limits to match your data range.
Observe the results in the layout.

150 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Exercise 4 Modifying the Palette for Tracks 4


and 5

In this exercise, you use the Palettes dock window to modify the
palette for Tracks 4 and 5 of the LogView plot.

1. Add Tracks 4 and 5 to the LogView layout.


2. Drag the VSH_GR variable into the LogView layout.
3. In the Palettes dock window, select the WBI256 palette.
4. Drag the FACIES04 variable into the LogView layout.
5. In the Palettes dock window, select the FACIES_5 palette.

Reference Tracks
You can add a track to your layout to provide a reference to your

© 2011-2013 Schlumberger. All rights reserved.


Index data set.

Procedure 5 Displaying a New Reference Track

On the same layout, you can display both the measured depth
and the TVD, TVDSS, or any other reference previously
calculated and present in the Index data set.

1. Insert a new reference track by selecting Insert >


Reference track or right-clicking on the layout and selecting
Insert a reference track.
2. Go to the Properties window of this reference track and
select the reference you want to display in the track.

Techlog Fundamentals, Version 2012 151


LogView Schlumberger Internal Use Only

Exercise 5 Creating a Reference Track for


Track 6

In this exercise, you display a new reference for Track 6.

1. Add a Reference Track as Track 6 in your layout.


2. For Track 6, display a reference track with True Vertical
Depth Sub Sea (TVDSS).
© 2011-2013 Schlumberger. All rights reserved.

152 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Zones
You can designate zonations in your LogView layout.

By default, all the zones have the same color, but it is possible to
customize these colors.

Other options also are available by right-clicking on the Zonation


dock window. The Display command allows you to display the
zones with an icon or a check box.

© 2011-2013 Schlumberger. All rights reserved.

Figure 38 Display icons command for zones

NOTE: Options are slightly different if you select one or several


zones before you right-click.

Techlog Fundamentals, Version 2012 153


LogView Schlumberger Internal Use Only

Procedure 6 Creating a Zonation Track in a


Layout

The zonation track allows you to insert and use zonation in a


layout. In this exercise, you create a zonation track in a LogView
layout.

1. Add a Zonation track for Track 7 in your layout. Go to the


layout and select Insert > Zonation track or right-click in
the layout and select Insert a zonation track.
If you are working with a layout displaying several wells, you
can insert a zonation track for each well by selecting Insert >
Plus… > Zonation track for each well.

The layout displays the newly inserted zonation track.


© 2011-2013 Schlumberger. All rights reserved.

2. From the Zonation dock window drop-down menu, select


the zonation set you want to display. The zonation track is
updated when you change selected zones or the zonation
set.

3. Define zone color:

a. Right-click in the Zonation dock window and select


Define zone color….
b. Select a color and click OK.
4. Define a pattern:

a. Right-click in the Zonation dock window and select


Define zone pattern….
b. In the Pattern selection window, pick the pattern for the
zone and click OK.

154 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

c. After the pattern is defined, switch the display of the zone


to pattern mode by right-clicking in the Zonation dock
window and selecting Display the patterns.
5. Assign zone colors automatically by right-clicking in the
Zonation dock window and selecting Automatic zone
color definition.

Exercise 6 Creating a Zonation Track in a


Layout for Track 7

1. In this exercise, you create a zonation for Track 7.


2. Insert a zonation track and display STRATIGRAPHY
zonation in color mode.
3. Define the zone colors (Automatic).
4. Define zone patterns (this will be used in a later exercise).

© 2011-2013 Schlumberger. All rights reserved.


5. Explore the Zonation track properties to reproduce the
display.

Data Set Created from LogView


After you create a layout in LogView, you can save a data set that
contains all the variables that you displayed on the LogView
layout. This is useful if you are displaying data from different data
sets on the same layout.

Techlog Fundamentals, Version 2012 155


LogView Schlumberger Internal Use Only

Procedure 7 Creating a Data Set with All Data


Displayed on the Layout

The layout is now finished. Before saving it, create a data set that
contains all of the variables displayed on the LogView layout.

1. In the Edit menu, select All variables.


© 2011-2013 Schlumberger. All rights reserved.

156 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

2. In the Edit menu, select Harmonized dataset > Build a


harmonized dataset….

© 2011-2013 Schlumberger. All rights reserved.


3. Enter a name for the new data set. Click OK.
The new data set appears in the Project browser.

Techlog Fundamentals, Version 2012 157


LogView Schlumberger Internal Use Only

Exercise 7 Saving Variables from a Layout

In this exercise, you create a data set that contains all of the
variables displayed on the layout

Save the data displayed in LogView as a data set named LQC_2.


© 2011-2013 Schlumberger. All rights reserved.

Lesson 3 Layout and Template

After setting a layout for a well, you can save the layout and apply
it to other data sets. In the Layout window, select Save > Save as
layout (Figure 39).

Figure 39 Saving a layout

The layout is saved to the Project browser under Layouts. You


can retrieve a layout in the project at a later time. You can apply it
to data sets or wells in the same layout, or you can apply it to
individual layouts.

TIP: The difference between a layout and a template is that a


template saves only the content of a layout, whereas a
layout saves the complete display.

158 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Exercise 1 Saving the Layout Created as a


Template

In this exercise, you save the layout that you created in previous
exercises as a template that you can apply to other data sets,
wells, or layouts.

1. In the LogView window, select Save > Save as a


template….
2. Enter a name for the template: WELL9_SHORT.
3. Select to save the template at the Project level.
4. Click OK.
The template is now saved in the Project browser.

© 2011-2013 Schlumberger. All rights reserved.


Procedure 1 Applying a Template to Other
Wells or Data Sets

This procedure shows you how to apply a template to other wells


or data sets.

1. Double-click a template in the Project browser.


2. In the Layout template window, select either Well template
or Dataset template.
A Well template applies to multiple data sets in a single well;
a Dataset template applies to a single data set in multiple
wells.

3. Choose the data sets or wells to which the template applies.

Techlog Fundamentals, Version 2012 159


LogView Schlumberger Internal Use Only

Exercise 2 Applying the Well9_SHORT


Template to Create Another
Template

In this exercise, you use the template that you saved in Exercise 1
to create a new layout template.

1. Double-click on the Well9_SHORT template in the Project


browser.
2. In the Layout template window, select Dataset template.
3. From the Choose datasets to plot window, select the data
set DATAFULL for Well1. Click OK.
4. Select Save > Save as layout of Well1.
© 2011-2013 Schlumberger. All rights reserved.

5. Enter a name for the layout: WELL1_SHORT.


6. Select to save the template at the Project level.
7. Click OK.
8. Close the layout.

160 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Exercise 3 Applying the Well9_SHORT


Template to other Data Sets

In this exercise, you display the correlation for the five wells.

1. Double-click on the Well9_SHORT template in the Project


browser.
2. In the Layout template window, select Dataset template.

© 2011-2013 Schlumberger. All rights reserved.


3. From the Choose datasets to plot window, select the
DATAFUL data sets for Well1. Click OK.
A LogView layout opens with the Well1 data displayed.

4. Select Layout > Other datasets (in the same layout)….

Techlog Fundamentals, Version 2012 161


LogView Schlumberger Internal Use Only

5. Select DATAFULL for Well2, Well3, Well4, and Well9


The layout containing the five wells is now displayed in
LogView. (Well9 is displayed at lower depths.)

6. Adjust the layout by clicking and .


© 2011-2013 Schlumberger. All rights reserved.

Several options are available for the multi-well layout (such


as Activate the well distance and Change the reference).

TIP: You can align the wells based on the top or bottom of
one selected zone. Click on the zone you want to align
in the zonation track.

162 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

7. Select the Alignment criteria you want to use.

© 2011-2013 Schlumberger. All rights reserved.


8. Close the multi-well layout without saving it.

Lesson 4 More LogView Options

For this lesson, you will continue to explore LogView


functionalities through practical exercises. These functions help
you to further define details in your layout.

These exercises in this lesson cover

• Well schematics
• Plots in log tracks such as histograms, crossplots and plot
groups
• Zonation shading
• Volumetric variables
• Core images
• Well overview.

Techlog Fundamentals, Version 2012 163


LogView Schlumberger Internal Use Only

As a starting point for the lesson, you need to reopen the


Well9_SHORT layout. Through the exercises you will build the
layout shown in Figure 40.
© 2011-2013 Schlumberger. All rights reserved.

Figure 40 Layout to build from Well9_SHORT template

164 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Procedure 1 Inserting a Well Schematic

The Well schematic feature allows you to display well tools and
drilling action within every track type, even the reference track.

1. Select the track where you want to insert the well schematic.
NOTE: You can insert a normal track (Insert > Normal
track) for a better display. If nothing is selected, the
well schematic is inserted in the first track of the
layout.

2. Select to Insert > Well schematic.


3. In the Well schematic dialog box, select the Type and other
parameters based on the type that you select.

© 2011-2013 Schlumberger. All rights reserved.

4. Click Add.

Exercise 1 Inserting a Well Schematic for


Track 3

For Track 3, insert the casing and openhole intervals.

Techlog Fundamentals, Version 2012 165


LogView Schlumberger Internal Use Only

Plots in Tracks
You can add histograms and crossplots for selected variables in
your layout tracks.

Histograms display plotted information about a single variable.


You can add these types of histograms:

• Stand-alone Histogram. Creates a histogram outside of the


LogView window.

• Histogram in track: Inserts a histogram into a LogView


track between two defined depths (using the Reference Top
and Bottom properties on the Limits tab of the Properties
window). You also can graphically modify the top and bottom
of the histogram.

• Histograms on depth intervals: Opens a window where


© 2011-2013 Schlumberger. All rights reserved.

you enter the parameters to create these histograms.

Figure 41 Options to create histograms on depth intervals

• Histogram per zones: Opens a window where you can


select the Zonation data set to use to create the histogram.

Figure 42 Using a zonation data set to create a histogram

166 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Crossplots allow you to display graphical information in a track


about more than one variable. You can create these types of
crossplot in LogView:

• Stand-alone Cross-plot: Creates a crossplot outside of the


LogView window.

• Cross-plot in track: Inserts a crossplot into a LogView


track between two defined depths (using the Reference Top
and Bottom properties on the Limits tab of the Properties
window). You also can graphically modify the top and bottom
of the crossplot.

• Cross-plot on depth intervals: Opens a window where you


enter the parameters to create these crossplots.

• Cross-plot per zones: Opens a window where you can


select the Zonation data set to use to create the crossplot.

© 2011-2013 Schlumberger. All rights reserved.


When you insert plots on a depth interval or plots per zone,
Techlog creates a plot group, which allows you to apply global
properties to all plots within the group. A group is locked by
default, but you can unlock the group in the Properties window.
To unlock the group, select no for the Lock option (Figure 43).

Figure 43 Option to lock and unlock a plot group

In a locked group, the display properties are global for all


displayed plots from one group. In an unlocked group, the display
properties of each plot can be set individually.

You can copy and paste a group into a plot track, move it to a plot
track, or remove it from a track. For plot per zone and plot by depth
interval options, the plotted top and the bottom depths are
different from the top and bottom of the plot itself.

Techlog Fundamentals, Version 2012 167


LogView Schlumberger Internal Use Only

You can modify the display limits in the Properties window to


produce a correct display independently of the area delimited by
the plot. Figure 44 shows an example of a corrected group plot.

You can move and stretch the plot in this interval without changing
the data. This option is activated automatically when you add plots
on a large interval; deactivate it by selecting the plot or plot group.
© 2011-2013 Schlumberger. All rights reserved.

Figure 44 Corrected plot group

After creating the plot, you can modify the top and bottom of each
plotted interval.

168 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Procedure 2 Creating Plots in Tracks

When you select one variable, you can add histograms in the
layout.

1. Select the variable you want to display on the histogram.


2. Go to the Insert menu or right-click in the LogView display.

3. Select the type of histogram plot you want to display. © 2011-2013 Schlumberger. All rights reserved.

• Stand-alone Histogram

• Histogram in track

• Histograms on depth intervals

• Histogram per zones.


4. Display a crossplot:
a. Select the variables you want to display on the crossplot.
Select the X-axis variable and second the Y-axis variable.

Techlog Fundamentals, Version 2012 169


LogView Schlumberger Internal Use Only

TIP: You can select a third variable. This last selected


variable will be used as the color scale.

b. Go to the Insert menu or right-click in the LogView


display.
© 2011-2013 Schlumberger. All rights reserved.

c. Select the type of plot you want to display.

• Stand-alone Cross-plot

• Cross-plot in track

• Cross-plot on depth intervals

• Cross-plot per zones.

Exercise 2 Creating Plots in Tracks 6 and 9

In this exercise, you insert plots into Tracks 6 and 9 (see


Figure 40).

1. In Track 6 insert a gamma ray histogram every 200 feet.


2. In Track 9 insert a Neutron density crossplot per zone, using
gamma ray as a color code.

170 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Procedure 3 Displaying a Variable as Text

This procedure shows you how to display a variable as text in a


LogView track.

1. Drag the variable into a normal track.


2. In the Properties dock window, set the Activate option of the
Text mode parameter to yes.
The variable display mode switches from curve display to
text. You can modify the text display settings from the
window.

Exercise 3 Displaying Variables as Text in


Track 10

In this exercise, you display the Hole Azimuth and Hole Deviation

© 2011-2013 Schlumberger. All rights reserved.


variables as text in Track 10 (see Figure 40).

1. Drag the Hole Azimuth and Hole Deviation variables into a


normal track.
2. Set both variables to Text mode.

Techlog Fundamentals, Version 2012 171


LogView Schlumberger Internal Use Only

Procedure 4 Hiding Zonation Shading in Tracks

This procedure shows you how to hide the zonation shading for all
the tracks (or for the one you select).

1. Select the LogView window.


2. Go to the Display options tab in the Properties window of
the multi-well layout, and set the Zonation > Area Fill >
Display property to no.
© 2011-2013 Schlumberger. All rights reserved.

3. (Optional) Select to display the Zone border.


4. Display several Zonation data sets in the same layout:
a. Insert a Zonation track.
b. Go to the Display options tab of the Zonation
Properties window and set the property Zonation >
Current zones to no. The current zonation corresponds to
the zonation selected in the Zonation dock window.
c. All of the zonation data sets present in the well are now
available for selection in the Zonation data set drop-down
menu. Select the zonation you want to display in the track.

172 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

You can display as many zonation data sets as you wish in


the layout.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 173


LogView Schlumberger Internal Use Only

Exercise 4 Displaying the STRATIGRAPHY


Zonation as Patterns in Track 10

For this exercise, display the STRATIGRAPHY zonation patterns


in Track 10 (see Figure 40).

Procedure 5 Creating a Cumulative Track

Array creation track is a track for cumulating ordinary variables.


You can display volumetric variables according to their
contribution to the rock volume.

1. In a LogView, select Insert > Track > Array creation


track.
An empty track with a pale orange background opens.
© 2011-2013 Schlumberger. All rights reserved.

2. Drag the volumetric variable you want to display into the new
track. You can drop variables one-by-one or several at the
same time.
The upper display limits are automatically adjusted when
multiple variables are added:

3. Define the limits of the track or the accumulation of all the


variables by setting the Horizontal axis value on the Limits
tab the Properties window for the track.
4. Delete variables directly by selecting them and clicking
Delete.
5. Change the order of the variables in the array track by
clicking the up/down arrow keys.
6. Change the display colors/patterns by selecting a variable
and changing its color in the Properties window.
7. Change the orientation of the header display by setting the
Header orientation option in the Display options tab of the
Properties window.

174 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

8. Save an accumulated variable:


a. Select the Array creation track.

b. From the Save menu, click Save the variables as


array, or right-click and select Save the variables as
array.
This creates one array in the Project browser that
contains the accumulated values of all the ordinary
variables composing it. The variables are saved in the
same order they were placed in the original array.

Exercise 5 Creating a Cumulative Track in


Track 14

For this exercise, create, save, and display an array in Track 14

© 2011-2013 Schlumberger. All rights reserved.


with these volumetric variables:

• VX_CALCITE
• VX_ILLITE
• VX_KAOLINITE
• VX_QUARTZ.
See Figure 39 for reference.

Techlog Fundamentals, Version 2012 175


LogView Schlumberger Internal Use Only

Procedure 6 Displaying Core Images

You can display core images in LogView in the same way as any
other log, by dragging the images into LogView. (See Figure 40,
Tracks 15 and 16.)

TIP: You can plot other logs directly on top of a photograph.

To optimize the display, you can change the zoom factor in the
Properties window of the Core Image track.

1. Select the track where the core images are displayed.


2. Drag the data into the track.
3. Go to the Display options tab of the Properties window for
the normal track (not the core image track).
© 2011-2013 Schlumberger. All rights reserved.

176 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

4. In the Properties window, adjust the Zoom factor property.


NOTE: For large images, it might be necessary to use core
image display optimization. Go to Project > Options
> Parameters tab > Advanced… and select the
property 8-bits display speed optimization for core
images. Images are converted to 8-bit images to
improve the performance of Techlog.

Exercise 6 Displaying Core Images in Track 16

For this exercise, display core images in Track 16.

1. Insert the DayLight data set into the layout.


2. Adjust the Zoom factor.
3. Insert a Separation track by selecting Insert > Plus > Insert

© 2011-2013 Schlumberger. All rights reserved.


separation track to the left or right of the DayLight data set
track.

Procedure 7 Using a Well Overview

Well overview is a widget embedded in LogView. It allows you to


navigate quickly along the borehole. This procedure shows you
how to activate the Well overview.

1. From the Display menu, select Well overview .


2. Select a variable to display in the well overview track (you
also can select a full track).
3. Right-click on the variable to display and select Display as
well overview .
The well overview allows you to navigate along the well,
moving it up and down (you also can use the mouse wheel).
You can stretch it to change the LogView scale accordingly.

Exercise 7 Using a Well Overview in Track 17

For this exercise, insert a well overview display in Track 17 (see


Figure 40) and use the GAMM variable.

You now have finished creating the layout. Save it as


Well9_FULL.

Techlog Fundamentals, Version 2012 177


LogView Schlumberger Internal Use Only

Lesson 5 Time Data Display

Techlog manages data with 16 significant figures (double


precision data), which makes supporting date-time data possible.
You can also import and save date-time data in a Techlog project.
All data processing tools (resampling, combining or resizing a
data set, time shift, and processing in LogView) work with time
data. Time data can be displayed in LogView the same as any
other data set.

Exercise 1 Creating a LogView Plot with Time


Data

In this exercise, you load data from the DateTime data set and
apply some smoothing on the data from LogView.
© 2011-2013 Schlumberger. All rights reserved.

1. Open an empty LogView layout.


2. In the first track, display the gamma ray (GAMM) and the
Compressional slowness (SONI) variables.
You can either drag the GAMM variable and then the SONI
variable into the layout. Alternatively, you can use the track
templates saved in a previous exercise.

a. Drag the CALIPER_GAMMARAY_SONIC track template


into the empty LogView layout.
Techlog opens the Choose datasets to plot window.

b. Select the Well9_DateTime data set and click OK.

178 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

The variables GAMM and SONI are now displayed as a


function of time in the Reference track.

3. In the second track, display the Neutron porosity (NEUT) and


density (DENS) variables. As with the first track, either drag
the NEUT and DENS into a new track or drag the
NeutronDensityTrack saved in a previous exercise into the
layout.
4. It might be convenient for time data to display the plot
horizontally.

Select LogView > Layout > Horizontal. The plot is now


displayed horizontally.

© 2011-2013 Schlumberger. All rights reserved.


5. Save the Layout as Well9_TIME.

Techlog Fundamentals, Version 2012 179


LogView Schlumberger Internal Use Only

Lesson 6 Basic Processing in LogView

In Techlog, you can apply some basic processing on the


variables. The processing menu allows you to open and apply
several processing tools using the current layout. For example,
using Median smooth from the Processing menu will open a
dialog box to set the parameters of the smoothing algorithm that
will be applied to prepare the data for an upscaled model. These
tools are available:

• Smoothing
• Gaussian smooth…

• Smooth with missing values…

• Median smooth…
© 2011-2013 Schlumberger. All rights reserved.

• Cleaning
• Outliners cleaning…

• Despike…

• Data clipping
• Interpolation
• Linear interpolation…

• Spline…
• Others
• Integrate …

• Derivative smoothing…

• First last reading…

• Standardize (Normalization)

• Cumulate
• Compaction (several compaction equations are available)

• Depth shifting (several options are available)


For more details on the individual methods and equations, refer to
the Techlog Help.

180 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Procedure 1 Applying a Processing Method

This procedure shows you how to apply a processing method to a


variable in LogView.

1. Select one or more variables in LogView.


2. From the Processing menu, select the method you wish to
use.

Exercise 1 Applying the Smoothing Function


to a DENS Variable

In this exercise, you use the smoothing function. As a data set


example, use the Well9_TIME template because most of the
processing can be applied with a time reference.

© 2011-2013 Schlumberger. All rights reserved.


1. Open the Well9_TIME template.
2. Select the DENS variable.

3. In the Processing menu, select the Gaussian smooth…


method. The Smooth window opens.

4. In the Smooth window, define the size of the sliding window.


The higher this value is, the smoother the curve will be
(because it takes more weighted points into account for the
calculation of the average).
a. Enter the smooth window size in milliseconds: 30000
b. Click OK.
A new variable named DENS_Smooth_30000ms* is added
on the NEUT/DENS track. By default, the results of the
smoothing are displayed in the original variable track.

NOTE: The asterisk * indicates that the variable is not saved.

Techlog Fundamentals, Version 2012 181


LogView Schlumberger Internal Use Only

5. Add a new Ordinary track and move the


DENS_Smooth_30000ms* variable to this track.
6. Repeat Step 2 through Step 5 using different smoothing
window sizes: 60000ms and 3mn (180000ms).
© 2011-2013 Schlumberger. All rights reserved.

7. The three newly created variables are not saved. Save the
variables.

a. Select Save > Modified variables….

182 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

b. In the Variable save window, select to save the variable


with a suffix.

c. Select the three variables to be saved.

© 2011-2013 Schlumberger. All rights reserved.


The three variables are saved in the DateTime data set.

Techlog Fundamentals, Version 2012 183


LogView Schlumberger Internal Use Only

Lesson 7 Header Editor

The Header editor is a tool that will help you create and edit
headers for LogView depth plots. You access the Header Editor
by selecting Home > Techreport > Header editor.

Exercise 1 Editing a Header in Techlog

In this exercise, you use the Header Editor to edit a header.

1. Import the file 14in Trailer.xml from


Techlog_2012\Exercises\01 Import Exercise\06 Header
Editor into Techlog.
The 14-inch header is stored in the Project browser.

2. View the imported header by double-clicking on 14in Trailer


© 2011-2013 Schlumberger. All rights reserved.

in the Project browser.

3. Notice that Techlog cannot find the picture to be displayed in


the header.
Double-click on the missing picture. The Image properties
window opens. The image displayed in the header should
have the name slb_logo_bw.gif and be stored in the
Company folder.

However, because this image is not available, Techlog


cannot display it in the header. You will replace this image
with another one.

184 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

4. In the Image properties window, select Customize in the


Folder containing the picture drop-down list.

5. Click Browse. By default, the Techlog installation folder is


displayed.
6. Browse to the subfolder png and click Select folder.
7. Enter the full name of the image to be used (including the
extension) into the Picture name (with extension) field. For

© 2011-2013 Schlumberger. All rights reserved.


this exercise, enter ProjectNewFinish.png. Click OK.

8. In the Header Editor, click again on the image rectangle.


9. Select the image.

Techlog Fundamentals, Version 2012 185


LogView Schlumberger Internal Use Only

10. In the Properties window, set Keep Proportions to no and


set Alignment to right.
© 2011-2013 Schlumberger. All rights reserved.

11. Adjust the size of the image.


The image is now updated.

TIP: If you wish to use another image or logo, a simple way


to import an image is to drag it from your desktop or
web browser into the Header editor in Techlog.

186 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

12. Notice the text boxes contain text such as %Well.Country%


and %Well.WELL-NAME%. In the header, you will modify
some of the well properties displayed and edit this dynamic
text.
Double-click on the text. The text box looks empty, but only
because the text is white.

© 2011-2013 Schlumberger. All rights reserved.


13. Highlight the text and change its color to view it.

14. Click the Add a property icon .


15. In the Add a property dialog box, set the Level to well.

Techlog Fundamentals, Version 2012 187


LogView Schlumberger Internal Use Only

16. Modify the Header to display these properties:


• WELL: %Well.WELL-NAME%
• FIELD: %Well.FIELD-NAME%
• COUNTRY: %Well.COUNTRY%
• X: %Well.X%
• Y: %Well.Y%
17. Save the header. In the Header Editor menu, select Save.
18. Save the header at the Project level and enter the name
14in Trailer edited.
© 2011-2013 Schlumberger. All rights reserved.

19. Click Save. The new header is added to the Project


browser.

20. Close the Header editor.

188 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Lesson 8 Window Screenshot Tool

The Window screenshot application allows you to save, copy,


and paste Techlog windows into documents, such as Microsoft
PowerPoint presentations, by using the built-in Window
screenshot tool.

These snapshot options are available in the Window screenshot


tool:

• Current window: Screenshot of the selected Techlog


window
• Current window (without title): Screenshot of the selected
Techlog window without the title of the window
• Graphical zone only: Screenshot of the selected Techlog
window without the title or scroll bars

© 2011-2013 Schlumberger. All rights reserved.


• Main window: Screenshot of the entire Techlog window.

Procedure 1 Capturing Screenshots

This procedure shows you how to access the Window


screenshot tool to capture images of Techlog windows.

1. Click or select Home > TechReport > Window


screenshot (F12).
2. Define the screenshot format and the parts of the window to
capture (only what is on the screen or all of the data).
3. Select where you want to store the captured image: file or
clipboard.

Techlog Fundamentals, Version 2012 189


LogView Schlumberger Internal Use Only

4. Click OK.
© 2011-2013 Schlumberger. All rights reserved.

190 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Lesson 9 Print Options

The printing interface allows you to print out all the plots that you
create in Techlog. Use one of these methods to print the plots:

• From Techlog toolbar, select Home > Techreport >


Print .

• From the LogView window, select Layout > Print.


• Use the shortcut Ctrl+Shift+P, P.

Layout Printing
Layout printing is based on the general printing interface, but it
has special requirements for depth-plotting.

© 2011-2013 Schlumberger. All rights reserved.


On the Properties tab, you can adjust these measurements.

• Margins
• Automatic: Leaves 1 cm (0.39 inch) of margin in each
direction.
• User: Allows you to modify the vertical and horizontal
margins.
• Without: Uses no margins (for depth plot printing/continuous
feed).
• Adjust: Allows you to adjust the vertical and horizontal
scales. There are four types of adjustment available from
the Properties tab. These adjustments can be different for
the vertical and the horizontal scales.
• Width
• Adjust to the page: Adjusts the layout width to fit the paper
width.
• Fixed scale: Allows you to specify a width and unit for each
track. This option prints the plot according to the track
properties. To view and modify this property, select a track
and on the Display options tab in the Properties window,
change the Track width property.

Techlog Fundamentals, Version 2012 191


LogView Schlumberger Internal Use Only

• Customize: Determines the size of the plot.


• Keep the proportions: Keeps the layout proportions in
LogView.
• Height
• Adjust to the page: Adjusts the layout height to fit the paper
height and allows you to specify the number of pages to
use. By default, the number is set to 1.
• Fixed scale: Respects the scale defined in the Layout
properties. For example, 1:200.
• Customize: Allows you to determine the size of the plot.
• Keep the proportions: Adjusts the layout height proportionally
to the specified width.
• Position: Define the position of the plot within the paper: left,
© 2011-2013 Schlumberger. All rights reserved.

center, or right side of the page.


On the Output tab, you have the option to save the current
properties and access some properties previously saved.

On the Layout tab, you have these options:

• Limitation: Allows you to define a depth interval directly from


the Limitation field on the Layout tab. You must define only
the minimum and maximum values of the interval in the
layout reference unit. The behavior is the same as the Apply
common limitation to all the wells option.
• Page header/footer: Allows you to display the track header on
each page and at the bottom and the well header at the
bottom.

192 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

Exercise 1 Printing a Layout

For this exercise, print the Well9_SHORT layout.

1. Open the Well9_SHORT layout in LogView.

2. Select Layout > Print. The Print properties window


opens.
3. In the Properties tab of the Print properties window, adjust
the parameters as displayed in this figure.

© 2011-2013 Schlumberger. All rights reserved.

4. In the Layout tab, select to display the track header and the
well header at the bottom.
5. Select Print into PDF as the print format.

6. Click Print.
7. Save the PDF.

Techlog Fundamentals, Version 2012 193


LogView Schlumberger Internal Use Only

Review Questions
• How do you apply a layout or template to several wells?
• When you apply a layout or template, how does variable
management change (user family alias)? How do you decide
which variable to display in the layout?
• How do you change the properties of a variable? A track? A
layout?
• How do you insert a plot or histogram into a layout?
• What are the different track types?
• Which option should you use to apply a single layout/
template to several wells?
• What is the difference between a layout and a template?
• How can you display a layout in TVD?
© 2011-2013 Schlumberger. All rights reserved.

• How can you modify the well header?

Summary
In this module, you learned about:

• configuring the appearance of LogView


• creating core image displays
• creating plots in track
• saving and applying a layout.

194 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only LogView

NOTES

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 195


LogView Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

196 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

Module 6 Plots
The Plot viewer tool allows you to compare multiple
measurements made at a single reference over a 2D plot. In
Techlog, the Plot viewer tool can incorporate as many as five
dimensions or variables in a single window, along with filters,
charts, secondary variables, user-defined regressions, and
equations.

All plots are linked to all other plots in your Techlog workspace,
which means that any point selection you make on a plot is
interactively displayed in other plots.

Learning Objectives
After completing this module, you will know how to:

© 2011-2013 Schlumberger. All rights reserved.


• configure the appearance of a plot
• manipulate the plot from tabs in the interface
• use the Cross-plot tools for selection
• work with regression equations.

Lesson 1 Appearance of the Plot


Interface

The Plot tool is in the same menu as LogView. Access this


feature from the Plot menu. Three categories of plots are
available:

• Single well plot


• Multi-well plot
• Matrix-plot.

Techlog Fundamentals, Version 2012 197


Plots Schlumberger Internal Use Only

The most common plots are presented on the left side of the
menu bar. More plot style options are available in the drop-down
menu for each plot category (Figure 45).

Figure 45 Single well, Multi-well, and Matrix-plot options


© 2011-2013 Schlumberger. All rights reserved.

The Techlog Plot interface (Figure 46 and Figure 47) has a


central viewing area in which the plot appears. The box on the left
side contains the variables, filters, and charts displayed over the
plot.

Figure 46 Cross-plot interface for a single well plot

198 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

© 2011-2013 Schlumberger. All rights reserved.


Figure 47 Cross-plot interface for a multi-well plot

TIP: If you do not see the variable side box, click on the side-
box icon just under the Close button.

The window opens the density values (Y axis) versus neutron


values (X axis). Optional dimensions include:

• color scale for the Gamma ray


• point size for the Gamma ray value
• label for the value of the FLD flag curve.

Techlog Fundamentals, Version 2012 199


Plots Schlumberger Internal Use Only

Display and Icons


The Plot interface has many icons that make it easy to perform
common operations (Figure 48).
© 2011-2013 Schlumberger. All rights reserved.

Figure 48 Icons in the Plot interface

200 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

Lesson 2 Plot Tabs

In single well mode, you can drag data into the corresponding X, Y
axes and color boxes (Figure 49). You also can view the plot
without the variables side-box and drop the data over the
interactive fields that display when you drag variables into the plot
window.

NOTE: Depending on the plot you select, the Charts tab might
not be available.

© 2011-2013 Schlumberger. All rights reserved.


Figure 49 Cross-plot X, Y, and color boxes

Techlog Fundamentals, Version 2012 201


Plots Schlumberger Internal Use Only

Variables Tab
In the Variables tab, you place curves to be displayed by
specifying the X axis, Y axis, Color code, Label, and Point size.
© 2011-2013 Schlumberger. All rights reserved.

Figure 50 Variables tab display

Filter Tab
The Filter tab allows you to refine the display using a different
variable. Most commonly, this is a qualitative variable.

For example, you might wish to display data points filtering on


facies, fluid code, or any classification group. In this example,
choose which facies or which combination of facies to display for a
more detailed analysis of the data.

In this lesson, you will see how to combine the filter with other
tools to provide the most accurate data analysis possible.

202 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

The plot in Figure 51 displays points belonging only to groups 1, 2,


and 3. For this plot, FACIES04 is used as color code.

© 2011-2013 Schlumberger. All rights reserved.


Figure 51 Filter tab

Techlog Fundamentals, Version 2012 203


Plots Schlumberger Internal Use Only

Charts Tab
The Charts tab adds predefined charts to the data (Figure 52).
Charts added over the data points allow you to identify the
lithologies and the presence of hydrocarbons.
© 2011-2013 Schlumberger. All rights reserved.

Figure 52 Charts tab

204 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

Exercise 1 Creating a Histogram

In this exercise, you create a histogram.

1. Go to the Plot tab and select Histogram.


2. From the DATAFULL data set in Well1, drag the GAMM
variable into the plot.
3. Right-click on the plot.
Several options are available from the histogram plot menu.

© 2011-2013 Schlumberger. All rights reserved.


4. Apply a palette to the Histogram.
a. In the histogram Properties window, on the Display
option tab, select yes for the X palette option.

Techlog Fundamentals, Version 2012 205


Plots Schlumberger Internal Use Only

b. Select a palette from the Palette dock window (you can


re-use the WBI256 palette and adjust the minimum and
maximum value for the Gamma ray (0-150)).
© 2011-2013 Schlumberger. All rights reserved.

5. Save the histogram as a template.

a. Select Save > Save as a template…


b. Save the template as GAMMA_RAY_HISTOGRAM at the
Project level.
The histogram template now is saved in the Project
browser.

6. From the histogram Properties window, complete these


steps:
a. On the Display options tab, select no for the With X palette
option.
b. For the Histogram type property, select Zonation.

206 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

7. From the Zonation dock, select the zones you want to


display on the histogram.

© 2011-2013 Schlumberger. All rights reserved.


8. Drag the FACIES04 variable into the Filter side box
9. From the histogram Properties window, on the Display
options tab, select filter for the Histogram type property.

10. Select the five facies.


11. Save the Histogram.

a. Select Save > Histogram.


b. Enter the name
Well1_DATAFULL_HISTOGRAM_FACIES.

Techlog Fundamentals, Version 2012 207


Plots Schlumberger Internal Use Only

c. Select the Project level.


d. Click OK.

Exercise 2 Creating a Neutron-Density


Crossplot

In this exercise, you create a Neutron-Density crossplot.

1. Open a single well crossplot.


2. Drag the NEUT and DENS variables into the corresponding
zone (respectively, X and Y) of the plot area, or into the
Variables tab.
© 2011-2013 Schlumberger. All rights reserved.

3. Use GAMM as the Color value.


4. In the Chart tab, select Schlumberger, Por-11 & Por-12,
Neutron Porosity vs Bulk Density, and TNPH.
5. Click Add to display this chart on the plot.

208 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

6. Save the plot as Well1_DATAFULL_NEUT_DENS_GAMM.

Exercise 3 Creating Additional Plots

In this exercise, reproduce these two plots.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 209


Plots Schlumberger Internal Use Only
© 2011-2013 Schlumberger. All rights reserved.

210 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

Lesson 3 Multi-well Plots

You can use most of the single plot viewers in Multi-well mode
except for array plot types and plots displaying dip variables.

Procedure 1 Creating a Multi-well Plot

In this procedure, you create a multi-well plot.

1. Select Plot > Multi-well and select the multi-well plot type
that you want to create.
The Input(s) (family, alias or variable) selection window
opens. This window allows you to select the mnemonic
(family name, alias, or variable name) to be used within the
method.

© 2011-2013 Schlumberger. All rights reserved.


NOTE: In the Input(s) (family, alias or variable) selection
window, a white cell in the Data type assignment
column indicates that this input is mandatory; a gray
cell indicates that the input is optional.

2. Select the family, alias, or variable you want to display and


click Create.
The plot opens.

3. Drag the data sets into the variable side box or the display
area of the plot.
The plot is created.

Box Plot
A box plot allows you to graphically display groups of numerical
data. You can use it to compare distributions among multiple
groups or sets of data.

The shape of the box plot provides information about the log. For
example, if the box is long, log values are quite dispersed. You
can verify the consistency of a log from one well to another to
check that the logs have the same range of values (same
minimum, maximum, and median).

Techlog Fundamentals, Version 2012 211


Plots Schlumberger Internal Use Only

A box is built by drawing lines between the 25th percentile, the


75th percentile, and the median.

• The 10th percentile (10 % of the log values that correspond


to the outliers)
• The first quantile (25 % of the log values)
• The median (50 % of the log values)
• The third quantile (75 % of the log values
• The 90th percentile (90 % of the log values). These values
are calculated. You can modify them in the box plot
Properties window on the Display options tab.

Exercise 1 Creating a Multi-well Box Plot

In this exercise, you create a box plot to compare the GAMM


variable from the five wells. Before starting this exercise, verify
© 2011-2013 Schlumberger. All rights reserved.

that all your wells have a color assigned.

1. Select Plot > Multi-well > Multi-well Box-plot.


2. In the Input(s) (family, alias or variable) selection window,
select the Gamma ray family and click Create.

The multi-well box plot opens in the Project browser.

3. In the Project browser, create a conditional selection to


select the DATAFULL data set for the five wells.

212 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

4. Drag the five data sets into the variable side box or the
display area of the plot.

© 2011-2013 Schlumberger. All rights reserved.


All the variables assigned to the Gamma ray family are
displayed. You can change the variables displayed on the
box plot manually by using the variable side box.

5. Select to display the box plot for a selected zone by selecting


the zone from the Zonation dock window.
6. Change the family displayed.

a. In the box-plot, right-click and select Family


change….
b. Select the Bulk density family.

Techlog Fundamentals, Version 2012 213


Plots Schlumberger Internal Use Only

Lesson 4 Matrix Plot

You can use matrix plots to generate mutual information on the


same display. The matrix plot allows you to display a defined plot
for several wells on the same display. All the types of matrix plots
work virtually in the same way.

Procedure 1 Creating a Matrix Pot

In this procedure, you create a matrix-plot.

1. Select Plot > Matrix-plot and select the plot you want to
create.
The Input(s) (family, alias or variable) selection window
opens. This window allows you to select the mnemonic
(family name, alias, or variable name) to be used within the
© 2011-2013 Schlumberger. All rights reserved.

method.

2. Select the family, alias, or variable you want to display and


click Create.
The plot opens.

3. Drag the data sets into the variable side box or the display
area of the plot.
The matrix plot is created.

Exercise 1 Creating a Histogram Matrix Plot

In this exercise, you create a histogram matrix plot to compare the


Gamma ray distribution in Wells 1, 2, 3, 4, and 9.

1. Select Plot > Matrix-plot > Histogram matrix-plot.


2. In the Input(s) (family, alias or variable) selection window,
select the Gamma Ray family and click Create.
3. In the Project browser, create a conditional selection to
select the DATAFULL data set for the five wells.
4. Drag the five data sets into the variable side box.

214 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

5. Right-click on the plot and select the Activate the quantile


display icon .

© 2011-2013 Schlumberger. All rights reserved.


Lesson 5 Plot Tools

Other plot tools offer a variety of options for selecting and


displaying data and quality control.

Use the Selection tools to select data points on one plot and view
these points on another plot. You also can apply an action after
the points are selected, such as deleting all selected points.

You can select data points in two ways.

Polygon type Draw a polygon around the area of


selection interest and select the points inside the
polygon.
Interactive Use the mouse to select the data points.
selection

Techlog Fundamentals, Version 2012 215


Plots Schlumberger Internal Use Only

Polygon Type Selection


A polygon is a graphical object that allows you to select a precise
area within the crossplot. There are many options available when
working with polygons.

Close a Draw the polygon and close it by coming


polygon back to the first point. The polygon closed
icon indicates your polygon is closed.
Click Enter to select the points inside the
polygon
Choose a Hold down the Ctrl key and click inside the
polygon polygon. You need to be sure you are in
Polygon mode as indicated by the pencil
icon . After a polygon is selected, the
borders turn red.
© 2011-2013 Schlumberger. All rights reserved.

Choose two or Hold down the Ctrl key and click inside each
more polygons polygon.
Move a polygon Choose a polygon and press the keyboard
arrows to move the polygon where you want
to display it.

TIP: If you choose multiple polygons, all of them will move


together.

Remove a Choose a polygon and click Delete.


polygon

TIP: If you choose multiple polygons, all of them will be


removed.

Modify the size Choose one polygon point to change the


and shape of a cursor to , which indicates that the point is
polygon selected. You now can move the polygon
point.
Choose all Ctrl + Alt + left mouse button
polygons

216 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

In the Edit menu, these commands are available:

• Delete the selected values

• Delete non selected values.

© 2011-2013 Schlumberger. All rights reserved.


Figure 53 Polygon selection and a log display

Techlog Fundamentals, Version 2012 217


Plots Schlumberger Internal Use Only
© 2011-2013 Schlumberger. All rights reserved.

Figure 54 Commands available from the Edit menu

Interactive Selection Tool


This tool uses a selection brush to choose data points (Figure 55).
In the Properties dock window on the Show options tab, you will
find options that allow you to choose a brush and adjust the brush
size.

After you select points, there are two ways to clear them:

• Clear all selected points by pressing the Esc key or the


Space bar.

218 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

• Clear only specific points by using the Interactive eraser


or Mouse mode.

© 2011-2013 Schlumberger. All rights reserved.


Figure 55 Interactivity between plots: Points selected on the
crossplot (left) are highlighted on the layout (right)

Techlog Fundamentals, Version 2012 219


Plots Schlumberger Internal Use Only

Statistics Display
In the top right corner of the crossplot, there is a gray box
containing important navigation information as shown in
Figure 56.

You can choose not to display the navigation box by setting the
Display option to no on the Display options tab in the Properties
window of the crossplot.
© 2011-2013 Schlumberger. All rights reserved.

Figure 56 Statistics box explanation

220 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

Lesson 6 Regressions

Regressions are equation lines displayed through the data points.


You can add regressions to fit the displayed data or insert them
graphically over the plot.

Create a custom regression by clicking in the interactive


toolbar.

© 2011-2013 Schlumberger. All rights reserved.


Figure 57 Regressions by filter

You can insert regressions in four ways:

• By filter: If a filter variable is used, a regression is calculated


for each filter group.
• By zone: If specific zones are chosen, a regression is
calculated by zone.
• Global: Generate a regression that takes into account all
displayed data. This does not account for data points that do
NOT display.
• Current selection: Generate a regression through selected
points using the Interactive Selection tool (Figure 58).

Techlog Fundamentals, Version 2012 221


Plots Schlumberger Internal Use Only

You also can generate regression lines on filtered data only.


© 2011-2013 Schlumberger. All rights reserved.

Figure 58 Regression calculated by current selection

The syntax used to define regressions is the same as the syntax


used in the Data editor. Refer to the Techlog Help for more
information about predefined operators and correct syntax. Click
Help when the interface is displayed to view a list of predefined
functions and the definition details of an equation.

222 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

Display Properties
As with Techlog objects, you can modify the appearance of the
equation line using tabs to change the display properties in the
Properties dock window.

• Parameters tab: Select the regression type (linear, power, or


exponential).
• Display options tab: Edit the title, marker size, type, and
color and activate the confidence interval display.
After you save the crossplots, you can apply these settings to
other crossplots and use them as default crossplot settings.

Procedure 1 Entering an Equation

You can enter your own equations from a crossplot using the

© 2011-2013 Schlumberger. All rights reserved.


Equation editor. This procedure shows you how to create an
equation and display it in a crossplot.

1. Take one of these actions to create an equation.

• From the Insert menu, click Add equation .


• Right-click inside the crossplot and select Add equation.

Techlog Fundamentals, Version 2012 223


Plots Schlumberger Internal Use Only

2. Enter an equation using Y and X values or the variable


names. For multi-well plots, use only X and Y values.

The resulting plot is shown in the figure.


© 2011-2013 Schlumberger. All rights reserved.

224 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

Procedure 2 Editing, Removing, and Copying an


Equation

In this procedure you edit, remove, and copy equations.

1. Edit an equation.
a. Choose the curve.
b. Right-click and select Edit the equation.
2. Remove an equation by choosing the equation and pressing
Delete.
3. Copy equations and regressions by selecting Edit >
Regression/Equation > Copy all equations and
functions.
The Output dock window displays all of the relevant
information about the line.

© 2011-2013 Schlumberger. All rights reserved.


Procedure 3 Saving the Display Properties

Techlog allows you to save the properties of a plot to apply them


to another plot. In this procedure, you save the properties of a plot
and apply them to a new plot.

1. From the Save drop-down menu, select Currents.


2. In the Display properties save window, choose the
properties that you wish to save and click OK.

3. Apply the properties file to another plot by opening a new plot


and selecting Properties > Apply.

Techlog Fundamentals, Version 2012 225


Plots Schlumberger Internal Use Only

Review Questions
• What are the different types of plots available in Techlog?
• How do you insert a second scale in a plot?
• How do you insert an Image in your chart?
• Which type of regressions can be inserted in a crossplot
within Techlog?

Summary
In the module, you learned about:

• configuring the appearance of a crossplot


• manipulating the plot from tabs in the interface
• using the Cross-plot tools for selection
© 2011-2013 Schlumberger. All rights reserved.

• working with regression equations.

226 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Plots

NOTES

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 227


Plots Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

228 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Module 7 Depth Interaction,


Interactive Selection
Mode, Zonation, and
Markers
This module covers several tools available in Techlog to link
different viewers and to create zones.

Learning Objectives
After completing this module, you will know how to:

• create and edit zones and markers using the Zone editor
• create and edit zones and markers using graphical tools in
LogView

© 2011-2013 Schlumberger. All rights reserved.


• manage markers.

Lesson 1 Depth Interaction Mode

Depth interaction is a tool that allows you to display and move a


depth line or a window along a layout. The line or window then
changes accordingly and the tool automatically updates the
display of the connected plot/tools that are listening to the depth
information sent by LogView.

Procedure 1 Setting the Depth Interaction Line

This procedure shows you how to launch the Depth interaction tool
and set the depth interaction line.

1. Open a LogView layout.

2. Activate the mode by selecting the dedicated icon in the


mouse mode toolbar.
3. On the layout, left-click at the desired depth on the LogView
where the interaction line is to be inserted (this is now your
starting point). The red line now can be moved up or down.

Techlog Fundamentals, Version 2012 229


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

When moving up and down in a LogView, only the selected


depth intervals will be displayed in the plots or in the table.

NOTE: This functionality works by well, meaning that


connected objects have to be part of the same well
set.

4. You can run the Depth interaction tool using a sliding depth
window. Crossplots are able to listen and display values
according to the zone of interest defined in the layout.
Activate the sliding depth window mode in one of these
ways:

• Right-click on the red depth interaction line and select


Activate the window mode.
• Left-click on the depth interaction line and then change the
associated property named Active window mode to yes in
© 2011-2013 Schlumberger. All rights reserved.

the Properties window.


5. You can open and synchronize other objects (such as
another LogView with different variables, or any single well
plot) with your LogView depth. You also can open the
3DVue or Data editor. The listening status of each object
must then be set to ON, so that each open window will listen
to the layout.
Turn listening mode on by right-clicking on the background of
each window, then clicking the Listening mode ON icon.
The icon appears green.

Exercise 1 Using the Depth Interaction Tool

In this exercise, you use the depth interaction tool. Before starting
the exercise, you will need to re-open several objects saved in
previous exercises. You also need to organize the different
windows to have these four objects displayed on your screen. It is
recommended that you use Dashboard mode.

• Layout: Well1_SHORT
• Histogram: GAMMA_RAY_HISTOGRAM
• Cross-plot: Well1_DATAFULL_NEUT_DENS_GAMM)
• A Data editor table.

230 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

1. From the LogView Well1_SHORT layout, activate depth


interaction mode by clicking the Depth interaction icon
in the toolbar.
2. Left-click at the desired depth on the LogView layout where
you want to insert the interaction line.
3. Activate the sliding depth window mode by right-clicking on
the interaction line and selecting Activate the window
mode.
After the window is activated in the layout, you can modify
the top and bottom of the interaction window on the LogView
layout manually. (You also can manually enter the top and
bottom in the Depth synchronization Properties window).

4. Activate Depth listening mode for the plots by right-clicking


on the background of each window, then clicking the

© 2011-2013 Schlumberger. All rights reserved.


Listening mode ON icon to change its color to
green.Activate the listening status for the Data editor table
by selecting Tools > Listening mode ON.
The display is now ready for depth interaction.

5. Scroll on the depth interaction window on the LogView


display and view the results on the histogram and crossplot.
Only the points included in the depth interaction window are
displayed on the plots.

Techlog Fundamentals, Version 2012 231


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

In the Data editor window, the depth corresponding to the


exact location of the interaction line is displayed in red and
the depths corresponding to the Interaction window are
displayed in gray.
© 2011-2013 Schlumberger. All rights reserved.

6. Move the depth interaction in LogView, modify the size of


the window, and observe the results in the different windows.
7. To remove the depth interaction window, select it and press
Delete.
8. Deactivate the listening mode for plots and table to display all
data.
Do not modify the display; you will re-use it in the next lesson.

232 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Lesson 2 Interactive Selection Mode

Interactive selection mode allows you to create interaction


between the plots and other viewers (layouts, tables). You can
select the points using two methods:

• Polygon selection (discussed in Module 6)

• Interactive selection mode


NOTE: Interaction only works between viewers on the same
workspace. You cannot connect two viewers in two
different workspaces.

Procedure 1 Using Interaction in the General


Workspace

© 2011-2013 Schlumberger. All rights reserved.


In the Techlog workspace, you can activate interaction between a
layout, Data editor, a Cross-plot (2D and/or 3D), Histogram,
Spectrum analyzer, or spider plot.

1. Click and hold to display the full drop-down menu of


Interactive selection mode.
2. Select a brush color.
3. Brush over the layout or plot to select points or depth
intervals. Points selected will be highlighted in the other open
plots or layouts.

Exercise 1 Working with Interaction in the


General Workspace

For this exercise, you reuse the display used in the depth
interaction exercise.

• Layout: Well1_SHORT (clear the STRATIGRAPHY zonation


selection from the Zonation dock window)
• Histogram: GAMMA_RAY_HISTOGRAM
• Cross-plot: Well1_DATAFULL_NEUT_DENS_GAMM)
• A Data editor table: GAMM, DENS, NEUT, and SONI.

Techlog Fundamentals, Version 2012 233


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

1. Click and hold to display the full drop-down menu of the


Interactive selection mode.
2. Select the LogView layout.
3. The interactive selection color is blue by default. Change the
color:
a. Click the small triangle on the Interactive selection icon
to open the drop-down menu.
b. Select the green brush color.
c. Choose some intervals on the log.
© 2011-2013 Schlumberger. All rights reserved.

Observe the results on the other plots and in the table.

4. Go to the histogram plot, select a second brush color, and


choose some bins on the histogram. Observe the results on
the other plots and table.
5. Go to the crossplot, select a third brush color and choose
some points on the cross-plot. Observe the results on the
other plots and in the table.

234 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

6. Go to the Data editor, select a fourth brush color and choose


some points on the crossplot. Observe the results on the
other plots and in the table.

© 2011-2013 Schlumberger. All rights reserved.


7. If you have made an error in selection, use the
Interactive eraser to clear the bad points.
You also can select which category of points you want to
remove.

Techlog Fundamentals, Version 2012 235


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

8. Remove the blue selection only.


a. Click and hold to display the full drop-down menu of the
Interactive eraser.

b. Go to the blue drop-down menu and select Cancel


selection.
© 2011-2013 Schlumberger. All rights reserved.

9. Delete all of the selected point-intervals.

10. In the drop-down menu of the Interactive eraser, select


All > Cancel selection.
11. Close the LogView display as well as the table and plots.

236 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Exercise 2 Creating a Zonation Data Set using


Interactive Selection

In this exercise, you create a zonation data set for wells 1, 2, 3, 4,


and 9 using the Interactive selection tool. For each well, you will
select the seal, reservoir, and water zone.

1. Open the Well1_SHORT layout.


2. Because you will be working with all five wells in this
exercise, you can simplify the layout. Remove the VSH,
FACIES, and TVDSS Tracks and clear the STRATIGRAPHY
zonation from the Zonation dock window.
3. Apply this layout to another data set in the same layout
(select the DATAFULL data set for the five wells).
4. Define the color of the interaction. For this exercise, use
• light brown for the seal

© 2011-2013 Schlumberger. All rights reserved.


• red for the reservoir
• dark blue for the water.
5. Select another color (different from the four default colors):
a. Left-click on one of the colors and select Edit in the drop-
down menu.
b. Add other colors to the default list by clicking Add one
color on the list.
6. Using the brush colors, define the seal, reservoir, and water
zone for each well.

Techlog Fundamentals, Version 2012 237


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

7. After the selection is done, go to the Interactive


selection drop-down menu and select Save the
variables zonation from the selection.
© 2011-2013 Schlumberger. All rights reserved.

8. In the Save the interaction as zone window, enter the name


Zonation_Interactive_Selection and click OK.

9. Remove the selected intervals using the Interactive


eraser by selecting All > Cancel selection.
10. Select the Zonation_Interactive_Selection zonation from the
Zonation dock window and modify the colors to have the
same color code: light brown for the seal, red for the
reservoir, and dark blue for the water zone.

238 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

11. Align the zones using the reservoir top.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 239


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

Lesson 3 Zonation

A zonation is a specific data set that stores your zones of interest


as intervals. In the Project browser, these data sets are
displayed with this icon (Figure 59) and are defined with the
Data set type Interval in the Properties window (Figure 60).
© 2011-2013 Schlumberger. All rights reserved.

Figure 59 Zonation data set

240 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

© 2011-2013 Schlumberger. All rights reserved.


Figure 60 Properties of the zonation data set

Each zonation is defined by a reference curve and at least one


curve defined with the family Zone Name (Figure 61). Other
information such as Zone description, Hydraulic zones, Fault
block, and Zones parameters can be present in the data set.

Each zone is defined with a top and a bottom. The Top and
Bottom values easily can be displayed by dragging the zonation
data set into a Data editor window.

In Figure 61, the zone name at depth 7,494 is defined by a


missing value.

Techlog Fundamentals, Version 2012 241


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

As a result, ZoneC and ZoneE are not contiguous and there is a


gap between depths 7,494 and 7,907. By comparison, there is no
gap between ZoneB and ZoneC, because the bottom of ZoneB is
the top of ZoneC.
© 2011-2013 Schlumberger. All rights reserved.

Figure 61 Zonation definition

242 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Procedure 1 Using a Zonation

You can use zonations in all Techlog modules (LogView, Plots,


Data editor, AWI). Zonation selection is performed from the
Zonation dock window:

1. In the Zonation dock window, choose the zonation in the


drop-down list.

© 2011-2013 Schlumberger. All rights reserved.


2. Choose the zones to use.

Several options are available from the Zonation dock


window. When you right-click within the window, the menu in
the figure appears.

Techlog Fundamentals, Version 2012 243


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

The commands in this menu allow you to display the


interzones, define the color and the pattern of the zones, and
change the name.
© 2011-2013 Schlumberger. All rights reserved.

3. (Optional) Display zones in the Zonation dock window with


check boxes, icons, or both.
a. Right-click within the Zonation dock window.
b. Select Display > Display checkboxes or Display >
Display icons.

244 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Lesson 4 Zone Editor

The Zone editor allows you to easily create and edit zonation
data sets. Zone settings, such as color and comment, also are
accessible and editable using this tool.

The Zone editor view is based on a tree representation of the


zonation (Figure 62).

© 2011-2013 Schlumberger. All rights reserved.

Figure 62 Top and bottom for each zone and well in the Zone
editor

Techlog Fundamentals, Version 2012 245


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

Each node represents a zone. The wells appear in each column


and the zone top or bottom depths are displayed in rows. Each
cell displays the depth value at the top and bottom of a zone for a
particular well. An empty or missing value in a cell means that no
value is defined for the cell.

TIP: The order in which the wells are displayed can be changed
by dragging the well names into the Zone editor header.
You also can rearrange the order of the zones using either
a drag-and-drop action or the shortcut keys Ctrl + up-arrow
or Ctrl + down-arrow.

To launch the editor, select Data > Zone editor (Figure 63).
© 2011-2013 Schlumberger. All rights reserved.

Figure 63 Launching the Zone editor

Procedure 1 Loading and Editing Data in the


Zone Editor

This procedure shows you how to load and edit zones into the
Zone editor.

1. Open the Zone editor from Data tab > Zone editor.
2. Drag wells into the Zone editor window.
3. Choose a zonation in the Zonation dock window.
4. Select the zones to edit.
5. After the data loads, double-click on a cell to edit it (you can
edit name and depth).
When a zone is selected, the lower part of the window
updates to show the zone color and description. You can
change the color if needed.

246 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

6. Assign a random color to a zone color by clicking auto, or


choose a color by clicking the colored square to the left of the
text field.

7. Modify the description of the zone in the text field. All of your
changes are recorded when you save the zonation.

© 2011-2013 Schlumberger. All rights reserved.


Procedure 2 Adding a Zone

In this procedure, you add a zone to a zonation set.

1. Click Add zone .


2. In the Zonation window, enter the name of the new zone and
click OK.

If an item was selected previously, the new zone is listed


after the selected item; otherwise, it is inserted at the bottom.

NOTE: A deleted zone is ignored, while a hidden zone (clear


the selection in the dock window) is taken into
account when you set values for the zones or save
the zonation.

Techlog Fundamentals, Version 2012 247


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

3. Remove a well from the editor using the top header


contextual menu (right-click on the well name you want to
remove).

4. After all changes are complete, save the zonation by clicking


© 2011-2013 Schlumberger. All rights reserved.

Save . The zonation data set is saved in every well


present in the editor.
NOTE: When a zonation is saved, if the top of a zone is
empty or contains a null value, the zone is skipped. If
the bottom of a zone is empty or contains a null
value, the top is saved and the bottom is considered
to be the top of the next zone.

248 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Miscellaneous Options
There are several additional options available in the Zone editor
Properties window (Figure 64).

© 2011-2013 Schlumberger. All rights reserved.


Figure 64 Zone editor Properties window

This table describes the properties in the Zone editor Properties


window.

Unit Define the unit in which to display values.


Reference Choose the type of reference with which to
work.

All the wells present must have the data


needed to use the selected type of
reference.
Zonation Name Enter the name of the zonation.
Background Display the zone color as background color
zone color for the item.
Values Set the precision with which the values are
precision displayed.
Values format Change the way numbers are represented.

Techlog Fundamentals, Version 2012 249


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

Update the Set this to update the editor when the


editor after selection is changed in the Zonation
zone selection window and the editor is not the active
window.

This option is useful when using zones in


LogView and editing at the same time.
Use maximal Save values with the maximum precision
precision when available or with the currently displayed
saving precision.
Save with the If this option is set to True, each zonation
original data set is saved using a reference
reference identical in type to the original one (if the
data set was already present).

If this is set to False, zonation data sets are


© 2011-2013 Schlumberger. All rights reserved.

saved using the current reference type.

TIP: Use Ctrl + A to expand/collapse all items.

250 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Exercise 1 Editing a Zonation

In this exercise, you manually edit a zone using the Zone editor.

1. Select Data > Techdata > Zone editor.


2. Drag Well1, Well2, Well3, Well4, and Well9 into the Zone
editor.
3. In the Zonation dock window, choose STRATIGRAPHY.
4. Expand ZoneD to display the top and bottom values.

© 2011-2013 Schlumberger. All rights reserved.


5. Edit the bottom of the zone in Well1 to create a gap between
ZoneD and ZoneE.

6. Click Add zone and name it ZoneG.

Techlog Fundamentals, Version 2012 251


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

7. Choose the new zone.


8. Right-click on ZoneG and select Fill the row with > The
total depth (TD) of each well in the contextual menu.

9. Click Save .
10. Name the new zonation STRATIGRAPHY_EDIT.
11. Verify that this zonation has been created in all five wells.
12. In the Zonation dock window, choose the new zonation
STRATIGRAPHY_EDIT.
13. Choose ZoneS.
14. Right-click and select Define Zone Color.
15. Choose a color in the pane.

Procedure 3 Creating a Zone with the Quick


Zone Creation Tool
© 2011-2013 Schlumberger. All rights reserved.

This procedure shows you how to create zones using the quick
zone creation zone mode.

1. In LogView, click the zone creation icon in the dynamic


toolbar.
2. Delimit the different zones by left-clicking at desired positions
directly in the layout.

3. Select Save > Save the zones….


The zones are now displayed and a text log (second track)
has been inserted automatically into the layout.

You can edit this text curve to add comments about each
zone.

4. From a graphical point of view, this ZoneName track also is


customizable.
a. Select the text variable.
b. Go to the Properties window, Display options tab.
All the properties under the Text zone allow you to edit the
display settings of the text zones.

252 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Graphical Tools for Editing Zones


There are several options available in LogView for editing
zonations. These options are accessed by clicking Zone editing
in zonation tracks .

• Add a zone
• Split a zone
• Merge a zone
• Disconnect two zones
• Move the top of a zone
• Delete a zone

Add a Zone
Click on a depth with no zone to add a new zone (Figure 65). Click

© 2011-2013 Schlumberger. All rights reserved.


to incorporate a new top.

Figure 65 Adding a zone

Techlog Fundamentals, Version 2012 253


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

Split a Zone
When you click on a zone, it is split into two zones (Figure 66).
Click in the zonation track to incorporate a new top.

Figure 66 Splitting a zone

Merge a Zone
© 2011-2013 Schlumberger. All rights reserved.

When you delete the top of a zone that is connected to another


zone, the zones are merged with the priority given to the upper
zone.

Figure 67 Merging zones

To merge a zone, move the cursor over a top, select it and press
Delete. Notice that the cursor changes during this operation.

254 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Disconnect Two Zones


To disconnect two zones, click on the bottom grip of a zone and
move the cursor upwards. Notice that the cursor becomes an
arrow for this task.

Figure 68 Disconnecting two zones

Move to the Top of a Zone

© 2011-2013 Schlumberger. All rights reserved.


Change the top depth by clicking on the top of a zone and moving
the cursor up or down (Figure 69).

Figure 69 Moving to the top of a zone

Techlog Fundamentals, Version 2012 255


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

Delete a Zone
To delete a zone, place the cursor over a zone name and press
Delete (Figure 70).

Figure 70 Deleting a zone

Exercise 2 Creating Zones using the Quick


© 2011-2013 Schlumberger. All rights reserved.

Zone Creation Tool

In this exercise, you create your own zonation from the LogView
window using the quick zone creation tool.

1. Open the Well1_SHORT layout.


2. From the Zonation dock window, remove the
STRATIGRAPHY zonation.

3. In the dynamic toolbar, choose Quick zones creation.


4. For this exercise, you will delimit the main sand bodies using
the quick zone creation tool. Delimit the different zones by
left-clicking at the desired positions directly in the layout.
5. Select six to eight sand bodies.
6. Save the zonation as Zonation_Quick_Sand by selecting
Save > Save the zones.

The new zones are displayed in the Zonation dock window.


Some adjustments are needed because the intervals
between the sand bodies should be left empty.

256 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

7. Click to change the mouse mode and modify the zones


limits, or add additional zones.

© 2011-2013 Schlumberger. All rights reserved.


8. After all of the sand bodies have been identified, assign a
yellow color to all the zones:
a. Go to the Zonation dock window.

b. Select all of the zones, right-click and select Define


zone color.
c. Select yellow.
9. Verify that there is no zone between your sand bodies by
activating the Display the interzones option from the Zonation
dock window.
In the LogView layout, the interzones are now visible.

Techlog Fundamentals, Version 2012 257


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

In the Zonation dock window, the zonation name now


appears with an asterisk (*). This indicates that the zone has
changed.

10. Save the zonation by right-clicking in the Zonation dock


window and selecting Save the zones.
© 2011-2013 Schlumberger. All rights reserved.

258 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Zones Manager
The Zones manager is an advanced feature that allows you to
pick zones in a LogView layout.

© 2011-2013 Schlumberger. All rights reserved.


Figure 71 Zones manager

The Zones manager is globally subdivided in two parts: a


selection area and an editing area.

Selection The lower section of the window corresponds


area (A) to the existing zonation data sets available in
the project.

You can choose any of the zonation data sets


in the drop down list (1) and then move them to
the upper window using the two arrow buttons
(2). You can choose either the overall zonation
set or selected zones.

Techlog Fundamentals, Version 2012 259


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

Editing area The upper section of the window displays both


(B) the newly created zones and the zones that
were edited from previous data sets (the zones
moved from the lower section to the upper
section).

You can apply a filter (3) to restrict the display


and availability of a zone, depending on the
folder level (User/Project/Company/Techlog).

There also is a toolbar (4) with actions to add,


edit, delete, and update the zones to create or
edit items. A search field (5) allows you to
retrieve objects quickly.

Procedure 4 Picking Zones in LogView using


the Zone Manager
© 2011-2013 Schlumberger. All rights reserved.

The Zones manager is an advanced feature that allows you to


pick zones in a LogView layout. In this procedure, you use the
Zones manager.

1. Open a LogView layout where you want to pick zones.

2. In the dynamic toolbar, click and hold on the icon and


choose Advanced zones creation. The Zones manager
opens.
3. The first time you open the Zones manager, it is empty.
Create the Zones/Facies.

a. Click the Add a new zone icon.


b. In the New zone properties window, define
• Name and Description for the zone
• Color and Pattern
• Level in which you wish to save the zone (Project,
User, or Company).
c. Press OK. The new zone is added to the filtered zones
list.
d. Modify the zones by selecting .

260 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

e. Remove a zone from the list by selecting Delete


selected zones.
4. In the zones list, select the zone/facies to be picked.
5. Go back to LogView. The cursor now is different and shows
the zone/facies to be picked.
6. Brush the intervals that belong to the selected zone/facies.
TIP: You can use the Advanced zone creation tool with
several wells at the same time.

7. Switch to the next zone/facies to be picked and repeat Step 3


through Step 5.
8. Before saving the zones, move the top and bottom of the
zones by hovering the mouse above the zones/facies or
delete a zone by pressing Delete.
9. When you are done picking the zones/facies, select Save >

© 2011-2013 Schlumberger. All rights reserved.


Save the zones.

Exercise 3 Picking Lithologies using


Advanced Zones Creation

In this exercise, you define lithologies using the Advanced zone


creation tool.

1. Open the Well1_SHORT layout.


2. From the Zonation dock window, remove the
STRATIGRAPHY zonation.

3. In the dynamic toolbar, select Advanced zones creation.


The Zones manager opens.
4. Create a lithology.

a. Click the Add a new zone icon.


b. In the New zone properties window, define
• Sand
• Color
• Pattern.
c. In the Patterns browser window, enter the first letters of
the lithology you wish to select to reduce the list.

Techlog Fundamentals, Version 2012 261


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

d. Select to save the facies at the Project level and click OK.
The new zone is added to the filtered zones list.
© 2011-2013 Schlumberger. All rights reserved.

5. Repeat Step 4 and create these lithologies: Shaly sand,


Shale, and Carbonate.
6. In the zones list, select the first lithology to be picked, Shale.

262 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

7. Go back to LogView. The cursor now is different and the


Shale pattern lithology appears.
8. Brush the intervals that correspond to Shale lithology.
9. Continue the exercise to identify Sand, Shaly sand, and
Carbonate.
TIP: You can move the top and bottom of the zones by
hovering the mouse above the zones/facies or delete a
zone.

10. When you are done picking the lithologies, select Save >
Save the zones and name the zone Zonation_Advanced.

© 2011-2013 Schlumberger. All rights reserved.

11. It appears that one lithology (Coal) is missing. Reopen the


Advanced zone creation window by selecting Edit > Edit
zones.

Techlog Fundamentals, Version 2012 263


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

12. In the Zone manager, create a new lithology named Coal.


13. Select the coal interval in the layout (around 8161 ft). You
can take this opportunity to refine your lithological analysis.
14. When you are done, save the zone as described in Step 10
and keep the name Zonation_Advanced.
Keep the layout open for the next exercise.

Exercise 4 Using a Zonation to Define an Area


Fill

Geologists use the Advanced zone creation tool to identify


facies from borehole images. A very convenient way to present
results is to use the Gamma ray measurement and add shading
corresponding to facies analysis.

In this exercise, you use the lithology determined to apply this


© 2011-2013 Schlumberger. All rights reserved.

method.

1. Insert a new normal track.


2. Drag the GAMM variable into the new track.
3. Select the track and remove the zone display for this track.
a. Go to the Ordinary track Properties window.
b. Open the Display options tab.
c. Set the Display property to no.

4. Select the GAMM variable, right-click and select Add fill


to the higher limit.
5. Select a temporary color for the fill.
6. Click on the area fill and go to the Properties window.
7. For the Type property, select zonation, then the name of the
zonation you want to use, Zonation_Advanced.

264 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

8. Set the Color mode to pattern.

© 2011-2013 Schlumberger. All rights reserved.


The area fill object now is using Zonation_Advanced as a
filling pattern.

Techlog Fundamentals, Version 2012 265


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only
© 2011-2013 Schlumberger. All rights reserved.

266 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Lesson 5 Markers

The new data set type markers is available in Techlog and


corresponds to a top or bottom of a zone. You can create markers
directly in LogView or import them from a file such as.txt or .las.
Markers are managed in the same way as Zonation, from the
Markers dock window.

Exercise 1 Creating a Markers Data Set

In this exercise, you create a markers data set.

1. Double-click on the CALIPER_GAMMARAY_SONIC track


template and apply this track to the Well1, Well2, and Well3
DATAFULL data set.

2. In the LogView dynamic toolbar, select the icon Create

© 2011-2013 Schlumberger. All rights reserved.


markers over Logview.
3. In the Markers manager window, create four markers at the
project level. The Markers manager window works in
exactly the same way as the Advanced zone creation
manager.

Techlog Fundamentals, Version 2012 267


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

4. Select one marker in the upper part of the window and pick
the marker on the layout for the three wells.
© 2011-2013 Schlumberger. All rights reserved.

5. After markers are displayed, select Save > Save markers as


and enter Marker_j.
WARNING: Creation mode and editing mode are not the
same thing. Before you save the markers, you
are working in creation mode; after you have
saved them, you are working in editing mode.

268 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

Procedure 1 Creating a Marker from Zonation

In this procedure, you create markers from a zonation data set.

1. In the Project browser, select a zonation data set.


2. Right-click and select one of these commands.

• Create ‘markers’ set from zone tops: The tops of the


zones will be used to define the references of the markers.

• Create ‘marker’ from zone bottoms: The bottoms of


the zones will be used to define the references of the
markers.

• Create ‘markers’ from zone tops and bottom: The top


and the bottoms will be used to define the references of the
markers. For example, if a zone is defined by a top and a

© 2011-2013 Schlumberger. All rights reserved.


bottom, two markers will be created, one for the top and one
for the bottom.
3. Enter a name for the marker data set. The newly created
data set is available in the Project browser.

Techlog Fundamentals, Version 2012 269


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

Exercise 2 Creating a Marker Data Set from the


STRATIGRAPHY Data Set

In this exercise, you create a Marker data set from a specific


zonation data set.

1. In the Project browser, create a conditional selection to


select the STRATIGRAPHY data set for the five wells.

2. Right-click and select Create ‘markers’ set from zone


tops…. The tops of the zones will be used to define the
references of the markers.
© 2011-2013 Schlumberger. All rights reserved.

270 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

3. Enter a name for the marker data set.

4. Open the CALIPER_GAMMARAY_SONIC track and apply


this track to the five DATAFULL data sets.
5. From the Markers dock window, select the Strati_TOP, right-
click and automatically assign colors to the markers.

© 2011-2013 Schlumberger. All rights reserved.


The markers now are displayed with colors on the LogView
display.

6. Modify the current markers, or add new markers, by using


the Graphical marker editing tool.

Techlog Fundamentals, Version 2012 271


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

7. Save your modifications by right-clicking inside the Markers


dock window and selecting Save markers….

Review Questions
© 2011-2013 Schlumberger. All rights reserved.

• How do you initiate the interactivity between the different


viewers (Data editor, Cross-plots, layouts)?
• What methods can you use to create zones?
• How do you edit zones?
• How can you modify the appearance of zones?
• Can you create a zonation in TVDSS?
• How can you delete a specific zone for several wells at the
same time?

Summary
In this module, you learned about:

• depth synchronization
• depth interaction
• working with zones in the Zone editor
• graphical tools to create zones in LogView
• creating and managing markers.

272 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Interaction, Interactive Selection Mode, Zonation, and Markers

NOTES

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 273


Depth Interaction, Interactive Selection Mode, Zonation, and Markers Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

274 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

Module 8 Data Editor


The Data editor allows you to observe, change, create, export,
import, and discretize data. It allows you to calculate new
variables or apply mathematical operations to existing curves.

You can perform the calculations on the entire depth interval or


only in a restricted interval. Additional mathematical operators
include add (+), subtract (-), multiply (*), divide (/), and power (**).

Learning Objectives
After completing this module, you will know how to:

• access and use the functions in the Data editor window


• calculate variables

© 2011-2013 Schlumberger. All rights reserved.


• manage equations
• import and export data with Excel.

Lesson 1 Data Editor Window

Launch the Data editor by selecting Data > Data editor. After
opening the window, choose one or more data sets or variables
and drag them into the Data editor window (Figure 72).

You can display variables, variable information, or variable values.


Variable information includes the number of values, standard
deviation, and mean value.

Techlog Fundamentals, Version 2012 275


Data Editor Schlumberger Internal Use Only

Displayed variable values are expressed according to the


reference, which is depth, generally.
© 2011-2013 Schlumberger. All rights reserved.

Figure 72 Data editor window

276 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

Data Editor Window Tabs


The Data editor window has four main tabs: Edit, Display,
Tools, and Save / load. Each tab displays a unique set of task
icons.

Edit Tab
There are many actions you can take using the icons on the Edit
tab (Figure 73).

© 2011-2013 Schlumberger. All rights reserved.


Figure 73 Icons on the Edit tab

This table describes the functions of the icons on the Edit tab.

Go to a specific line. When this icon is activated, dialog


boxes are displayed according to the index setting.

When the index is toggled to No in the Properties dock


window, the values are displayed as reference values
(MD).

When the index is toggled to Yes, the values are


displayed as a row number.
Find and replace variable values. This operation can be
applied to a variable or a previously selected area.
Copy values into the Data editor.

Paste the copied value into the Data editor.

Techlog Fundamentals, Version 2012 277


Data Editor Schlumberger Internal Use Only

NOTE: The keyboard shortcut keys are Ctrl + C (copy) and Ctrl
+ V (paste).

Copy the current equation.

Create a new data set.

Create a new (empty) variable.

Add a row before the current row.

Add a row after the current row.

Delete the current row or column. A variable can be


removed from the Data editor by selecting the variable
and pressing Delete, or by right-clicking on the variable
header and selecting Remove.
© 2011-2013 Schlumberger. All rights reserved.

Display Tab
There are many actions you can take using the icons on the
Display tab (Figure 74).

Figure 74 Icons on the Display tab

278 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

This table describes the functions of the icons on the Display tab.

Switch between Variables mode and Data mode. When


changing from one mode to another, the same data is
displayed for statistics values for each variable inside the
Data editor (min, max, mean, standard deviation).

Change the row identification from the index to the


reference.
Available when you drag the array variable into the Data
editor. To activate the option, click on the header column

© 2011-2013 Schlumberger. All rights reserved.


of an array variable.

A window is displayed that allows you to choose which


array columns are to be displayed in the editor.
Merge variables into an array. To merge variables,
choose a variable and click this icon.

A window is displayed that allows you to customize the


column order of the newly created array and to choose a
name using the blue arrows.

Fit the column size to the displayed value.

Recompute statistics.

Techlog Fundamentals, Version 2012 279


Data Editor Schlumberger Internal Use Only

Tools Tab
There are many actions you can take using the icons on the Tools
tab (Figure 75).
© 2011-2013 Schlumberger. All rights reserved.

Figure 75 Icons on the Tools tab

The option to discretize transforms a quantitative variable into a


qualitative variable.

280 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

To discretize a variable, select a variable and click . The


window in Discretize current variable opens. In this example, it
shows a density.

© 2011-2013 Schlumberger. All rights reserved.


Figure 76 Discretize current variable

By default, the variable is divided into ten equal intervals from its
minimum to its maximum variable value. You can adjust the
default division and choose any number of intervals between 2
and 200 for the minimum and maximum values, respectively.

You also can redefine the boundaries of each interval to improve


accuracy. To edit a boundary, select a boundary and double-click
inside the Lower boundary box.

NOTE: You can modify only the lower boundary; the upper
boundary of the next interval automatically adjusts to the
new value.

Techlog Fundamentals, Version 2012 281


Data Editor Schlumberger Internal Use Only

To add a prefix to the existing name, add it in the Prefix box in the
upper right. The prefix is added automatically to the 10 intervals
(Figure 77).
© 2011-2013 Schlumberger. All rights reserved.

Figure 77 Automatically adding a prefix to a name

To validate the changes, click Apply. A new variable appears in


the Data editor with the suffix _RANGE (Figure 78). Optionally,
you can save the variable to the database.

Figure 78 Validating changes with a new variable

282 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

Tools Tab Functions


This table describes the functions of the icons on the Tools tab.
Most icons are self-explanatory.

Discretize a variable (discussed above)

Enter a description

Import from Excel to the Data editor

Export a spreadsheet to Excel and display the data in the


Excel print preview
Launch the equation

Launch the equation on several tabs

© 2011-2013 Schlumberger. All rights reserved.


Open the Equation editor

Create an equation

Edit the equation

Remove the equation

Depth listener

Techlog Fundamentals, Version 2012 283


Data Editor Schlumberger Internal Use Only

Save / Load Tab


There are only a few actions you can take using the icons on the
Save / load tab (Figure 79).
© 2011-2013 Schlumberger. All rights reserved.

Figure 79 Icons on the Save / load tab

This table describes the functions of the icons on the Save / load
tab.

Save the current data set. If several variables are


modified, you can save all of the variables simultaneously
by saving the whole set. When saving a variable, you
either can overwrite the previous set or create a new one.

In the Dataset save window, enter a new data set name


and save all variables by selecting Yes or save only the
modified variables by selecting No.

This option also allows you to duplicate a set and all the
data it contains.

284 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

Save only the selected variables. When a variable has


been modified but not saved, it is marked by an asterisk
(*). To save the variable, right-click on the variable header
and click Save to overwrite the previous variable or click
Save as to create a new one.
Interactive help files

What is this assistance

Exercise 1 Creating a New Data Set in the


Data Editor

In this exercise, you use the Data editor to build a data set with
variables and a discretized curve.

© 2011-2013 Schlumberger. All rights reserved.


1. In the Data menu, open the Data editor.
2. Choose the DATAFULL data set from Well1,
3. Choose the variables GAMM, DENS, NEUT, and SONI.
4. Drag the variables into the Data editor.
5. Choose the variable GAMM.

6. On the Tools tab, click Discretizing current variable to


create the discretized curve.
7. Choose 0 for the Lower boundary value, 200 for the Upper
boundary value, and 10 for the number of intervals and click
OK.
A new variable, GAMM_RANGE, appears in the Data editor.

Techlog Fundamentals, Version 2012 285


Data Editor Schlumberger Internal Use Only

8. In the Save / load tab, select the new curve in the Data
editor and click Save the selected variables .
© 2011-2013 Schlumberger. All rights reserved.

TIP: If you right-click on the variable name, several


commands are available to save the selected variable,
save it as a new version, or remove the selected
column.

9. In the Save / load tab, click to change the data set name
to DATAFULL_Selection.
10. Choose No for the All variables option and click OK.
A new data set is visible in Well1 containing only the
variables present in the Data editor.

286 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

Lesson 2 New Variable Calculation and


Mathematical Operations

The Data editor allows you to calculate new variables or to apply


mathematical operations to existing variables (Figure 80). You
can run the calculations on the entire depth interval or only in a
restricted interval.

The Data editor also allows you to create new variables by


applying mathematical operations to existing variables. These
equations can be saved and reused in other projects.

Figure 80 shows a new variable that has been inserted


automatically in the Data editor, but it has not been saved yet.

© 2011-2013 Schlumberger. All rights reserved.

Figure 80 Calculating variables in the Data editor

Techlog Fundamentals, Version 2012 287


Data Editor Schlumberger Internal Use Only

To see a list of functions available in the Data editor (Figure 82),


click What is this? (in the Save / load tab) or press Shift + F1,
then click on a cell containing a defined equation.

Figure 81 Accessing Help in the Data editor


© 2011-2013 Schlumberger. All rights reserved.

288 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

© 2011-2013 Schlumberger. All rights reserved.

Figure 82 Functions available in the Data editor

Techlog Fundamentals, Version 2012 289


Data Editor Schlumberger Internal Use Only

Procedure 1 Working with Equations

In this procedure, you create and save an equation.

1. On the Tools tab, click Create an equation to define a


new equation.
2. Enter the name of the equation.
3. Choose the unit of the output curve.
4. Choose the family of the output curve.
5. Enter comments about the equation.
6. Choose the level at which the equation will be saved: Project,
User, or Company.
© 2011-2013 Schlumberger. All rights reserved.

290 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

Procedure 2 Editing an Equation

In this procedure, you edit an existing equation.

1. Open the Tools tab.


2. Choose the equation that you wish to edit from the drop-
down list and click . The Properties of the new equation
window opens.

© 2011-2013 Schlumberger. All rights reserved.


3. Edit the properties of the equation and click Save.

Procedure 3 Removing an Equation

In this procedure, you delete an equation.

1. Open the Tools tab.


2. Choose the equation that you wish to edit from the drop-
down list and click Delete .
3. Click Yes to confirm that you wish to delete this equation.

Techlog Fundamentals, Version 2012 291


Data Editor Schlumberger Internal Use Only

Exercise 1 Using the Data Editor to Create an


Equation

In this exercise, you calculate the Shale volume from gamma ray
using the equation editor in the Data editor.

1. In the upper part of the Data editor, create an equation


named VSH_DE = (GAMM-15)/(120-15) and press Enter.
NOTE: The variable name appears with an asterisk (*),
which means that it has been modified and needs to
be saved.

2. Save the new curve by right-clicking on the VSH_DE*


variable and selecting Save the selected variable.
3. Open the Tools tab.

4. Click to create a new equation.


© 2011-2013 Schlumberger. All rights reserved.

5. In the window that opens, set these properties:


• Name: Volume of Shale
• Unit = v/v
• Family = Shale Volume
• Level = Project.

Procedure 4 Displaying Variable Array Type


Data

Log array type data and vectors that contain more than one
measurement per depth can be displayed in the Data editor. Log
array type data is identified with the Column selection icon
from the Display tab.

1. Drag the data into the Data editor.

2. Choose the variable column header. Column selection


on the Display tab is now active.

292 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

3. Click Column selection to display the Columns


selection window.

© 2011-2013 Schlumberger. All rights reserved.


4. Choose one or more of the columns to display and click OK
to expand the variable array.
For example, when you select two columns, they display as
multiple highlighted columns in the Data editor, as shown in
the figure.

You also can perform computations with an array variable.

Techlog Fundamentals, Version 2012 293


Data Editor Schlumberger Internal Use Only

For example, if you multiply an array variable by a constant


value, all columns are multiplied by the same constant value.
The results are illustrated in the figure.

NOTE: The equation is defined with the name of the array


and the results are saved as an array variable.
© 2011-2013 Schlumberger. All rights reserved.

Exercise 2 Computing a Variable with an Array


Variable

In this exercise, you use log array type data in the Data editor to
compute a variable from an array variable.

1. Open a new empty Data editor.


2. Choose MICP from Well1.
3. Choose the array CShg.
4. Drag the array into the Data editor.
5. Select the CShg column.

6. On the Display tab, click .


7. Choose several column numbers and click OK.
8. In the equation area, compute CSW as 1-CShg.
Notice that the Data editor displays only the first column of
the computed array.

9. Select CSW[0] and click to select the columns to display.

10. Choose the new variables and click .

294 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

11. Click Yes to confirm you wish to save an array.


12. Choose the new variable and click the Merge variables into
an array icon.

Lesson 3 Excel Connection

Data can be exported directly into Excel with one click on the
Tools tab. You can perform calculations and import the results
back into the Data editor.

Procedure 1 Connecting with Excel

In this procedure, you export data from the Data editor to Excel.

1. Click Export from Data editor .

© 2011-2013 Schlumberger. All rights reserved.


Excel is automatically launched and the data in the Data
editor window are exported to Excel.

2. In Excel, modify the imported variables, calculate other


variables, or use existing macros.
3. After completing all calculations, click Import from Excel to
Data editor .
WARNING: The new calculated variables must have names,
or they cannot be imported into the Data editor.

Techlog Fundamentals, Version 2012 295


Data Editor Schlumberger Internal Use Only

Exercise 1 Exporting and Importing the


GAMM Curve

In this exercise, you export and import a variable after applying an


equation in Excel.

1. Open an empty Data editor.


2. Choose the DATAFULL data set from Well1.
3. Drag the GAMM curve into the Data editor.

4. Click Export from Data editor .


5. In Excel, use the GAMM values to compute a new variable
named VSH_Excel as (GAMM-20)/110 when the variable
GAMM is defined.

6. Click Import from Excel to Data editor .


© 2011-2013 Schlumberger. All rights reserved.

7. Save the new variable.

Review Questions
• How do you handle the display of array data?
• How do you launch an equation on several data sets at the
same time?
• What is the best way to export data to Excel contained within
a data set?

Summary
In this module, you learned about:

• accessing and using the functions of the Data editor


• calculating variables
• managing equations
• importing and exporting with Excel.

296 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Data Editor

NOTES

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 297


Data Editor Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

298 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

Module 9 Well Trajectories, Field


Map, and Well Predict
In this module, you will learn about several tools available in
Techlog to display well trajectories in 2D and 3D. You also will
learn about cover maps and the Well predict application.

Learning Objectives
After completing this module, you will know how to:

• display well trajectories in 2D and 3D


• display well location and plots on a map
• use the well predict module and use the Techlog Application
Workflow Interface (AWI).

© 2011-2013 Schlumberger. All rights reserved.


Lesson 1 2D Well Trajectories

The 2D well trajectory allows you to view the well trajectory in


cross section or top view, with curves or dips along the well.

NOTE: The borehole trajectory of the well is read directly from


the index data set with XOFFSET and YOFFSET
variables. You cannot display a well without these
variables.

Exercise 1 Displaying the Well9 Trajectory in


2D

In this exercise, you display the Well9 trajectory.

1. Select Geology > FieldMap > 2D well trajectory.


2. For this exercise, use the GAMM variable from the LQC data
set (Well9). Drag the GAMM variable from the Project
browser into the left side of the 2D well trajectory window
under the Well tab.
TIP: If you drag a well into the window, by default Techlog
will display the first variable from the first data set.

Techlog Fundamentals, Version 2012 299


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

3. Select the STRATIGRAPHY zonation set to be displayed


from the Zonation dock window to display the zones on the
map.
4. From the Properties window, change the display type to top
view in the Trajectory tab.

TIP: You also can select the Map view icon by right-
clicking on the plot. You can come back to the trajectory
by selecting the cross section icon .

5. Save the Well9 trajectory at the Project level.


© 2011-2013 Schlumberger. All rights reserved.

300 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

© 2011-2013 Schlumberger. All rights reserved.


Lesson 2 3D Well Trajectories

The 3D Field viewer provides a 3 dimensional well display


environment. Continuous variables, wellbore images, and Maps
created in the Krigging module also can be displayed.

To display a well within the 3D field viewer, it is mandatory to have


an index data set containing variables with these families: X
Offset, Y Offset, True Vertical Depth Sub Sea, and Measured
Depth.

Additionally, to plot multiple wells within the same 3D viewer, it is


mandatory to define the X and Y well properties.

Techlog Fundamentals, Version 2012 301


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

Procedure 1 Creating a 3D Well Trajectory

This procedure shows you how to create a 3D view of a well


trajectory.

1. Select Utility > 3D Vue > 3D Field Viewer.


2. Drag the variable you wish to display into the side-box of the
3D Field Viewer.
If a caliper is associated to an image variable, then it is
automatically plotted around the well trajectory and the
image is mapped on the well.

If there is no caliper, then the well appears as a constant


diameter tube.
© 2011-2013 Schlumberger. All rights reserved.

302 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

Exercise 1 Creating a 3D Well Trajectory

In this exercise, you use the 3D Field Viewer to create a 3D view


of a well trajectory.

1. Select Utility > 3D Vue > 3D Field Viewer.


2. Drag the Well9 /LQC/GAMM variable into the side-box of the
3D Field Viewer.
The GAMM variable is now displayed along the 3D trajectory.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 303


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

Lesson 3 Basemap Tool

The Basemap is a visual mapping tool that allows you to create a


representation of the geographical position of the wells.

Procedure 1 Creating a Base Map

In this procedure, you display wells on a geographical map using


the Basemap module.

1. Select Geology > FieldMap > Basemap.


2. Drag the wells you wish to display under Wells in the side
box, or onto the Well drop area.
The geographical position of the well is displayed directly
from the well properties: X and Y locations. A well without
© 2011-2013 Schlumberger. All rights reserved.

these properties cannot be displayed. You can view the X


and Y locations in the wells Properties window.

You can read the geographical position of the well path from
the index data set where X and Y offsets need to be present.
A well without the X and Y offset properties can be displayed,
but the path is not displayed.

304 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

Exercise 1 Creating a Base Map and


Displaying Plots on the Map

In this exercise, you create a map with the five wells.

1. Select Geology > FieldMap > Basemap . An empty map


is created.
2. In the Project browser, select the five wells and drag them
into the empty map.

3. Zoom using the zoom icon to display the geographical


position of the Well9 path. (This is possible because X and Y
offsets are present in the Index data set.)
TIP: After zooming, double-click on the map to go back to
the original display.

© 2011-2013 Schlumberger. All rights reserved.


4. In the Basemap properties window, on the Display options
tab, activate the Well color option.

5. It is possible to display plots on the base map. In the Project


browser, choose the GAMMA_RAY_HISTOGRAM
previously saved and drag this template into the Plots area
on the side box.

Techlog Fundamentals, Version 2012 305


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

6. You also can display any saved tracks. Repeat Step 5 and
use the NeutronDensityTrack saved previously.
© 2011-2013 Schlumberger. All rights reserved.

306 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

© 2011-2013 Schlumberger. All rights reserved.


7. In the Save tab in the Basemap menu, save the map as
My_First_Map at the Project level.

Exercise 2 Creating a Cross Section

In this exercise, you create a cross section from Basemap.

1. Select Well2, Well3, Well4 and Well1 on the map.

2. Select Open > Layout


3. Click Yes in the confirmation dialog box that opens.
If you select No, the Input(s) (family, alias or variable)
selection window opens. You can select the variables and
families you wish to display on the cross section.

Techlog Fundamentals, Version 2012 307


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

4. Choose the template Well9_SHORT.


The cross section is created using the Well9_SHORT
template. The distance between the wells on the layout is
proportional to the actual distance between the well heads.
You can select to remove the Well distance on the Limits tab
in the Multi-well layout properties window.
© 2011-2013 Schlumberger. All rights reserved.

All the plot options covered in Module 6 (such as changing


the depth reference and aligning the zones) are available
from this LogView display.

308 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

Lesson 4 Well Predict

The Well predict tool estimates the logs on wells based on the
logs from the surrounding wells. Log estimation is performed
using geometry on a zone-by-zone basis, by stretching or
squeezing known logs with the required depth reference (TVD by
default) and aggregating information from all the input wells.

© 2011-2013 Schlumberger. All rights reserved.


Figure 83 Well predict

Procedure 1 Starting Well Predict

This procedure shows you how to set up Well predict to estimate


the log responses for a well.

1. Select Data > Techdata+ > Well predict.


2. From the Data management window, select the inputs to
predict (Family, Alias, or Variable) and click Create. You can
predict one or more log curves. The application Workflow
manager window opens.
3. Drag the data sets from the reference wells and the data sets
for the prediction wells into the Workflow manager.

Techlog Fundamentals, Version 2012 309


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

4. Define the inputs:


• Reference: Wells used as reference to compute the
prediction wells.
• Prediction: Wells to be predicted without measurement from
the field.
• Validation: Wells used both as reference and validation
where you already have measured variables. Their goal is
to evaluate the validity of the prediction by comparing
measured and predicted variables.
5. In the Zonation dock window, select the zones to add to the
workflow.

6. Go to the Zonation tab and click to insert the zones from


the Zonation dock window.
7. Go to the Parameters tab to set the options for each zone.
© 2011-2013 Schlumberger. All rights reserved.

Choose one of these methods:


• Distance method: This method combines the responses
from each initial input well weighted according to its
distances from the prediction well. For the computation, you
need to know the coordinates of the wells and the well
trajectories to get TVD and TVDSS.
• Average method: This method is a basic arithmetic average
between the reference logs by zones that required only the
Measured Depth.
8. Define the size of the smoothing window for the computation
by zone (the method is the Gaussian Smooth).

9. Click to launch the Well predict method. A layout is


displayed with the input variables for each well. The last well
is the predicted well.

310 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

Exercise 1 Using Well Predict

In this exercise, you predict the GAMM, DENS, and SONI log
responses in Well1 using the same variables from Well2, Well3,
Well4, and Well9.

1. Select Data > Techdata+ > Well predict.


2. In the Well predict window, select the Gamma Ray,
Compressional Slowness, and the Bulk Density families and
click Create.

© 2011-2013 Schlumberger. All rights reserved.


The application Workflow manager window opens.

3. Create a conditional selection to select the five DATAFULL


data sets from the Project browser.

Techlog Fundamentals, Version 2012 311


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

4. Drag the five DATAFULL data sets into the Workflow


manager.
The inputs are populated automatically. However, because
several variables from the DATAFULL data set are
associated to the families selected, you need to enter the
correct variable name manually.

5. Leave the Inputs for Well1 blank (predicted well).


6. In the last column (Type), select
• Prediction for Well1.
• Reference for Well2 and Well4
• Validation for Well3 and Well9.
© 2011-2013 Schlumberger. All rights reserved.

7. Go to the Zonation tab.


8. Select all the zones from the STRATIGRAPHY data set in
the Zonation dock window and click to insert the zones
from the Zonation dock window.

312 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

9. On the Parameters tab, apply the Distance method and a


Smoothing window equal to 1.
10. Given that data do not cover all the wells and all the intervals,
some adjustments have to be made in the Parameters tab.
For each interval, clear these wells from the drop-down list in
the Input Wells column:
• ZoneB: Well2, Well3, Well4
• ZoneC: Well2, Well3, Well4
• ZoneD: Well2, Well3, Well4, Well9
• ZoneE, ZoneF, ZoneS: Well3, Well4.

© 2011-2013 Schlumberger. All rights reserved.


11. Set the Apply mode to Display and click to launch the
Well predict method.
A layout opens with the input variables for each well and for
the predicted well. The last well displayed is the predicted
well.

• Reference wells (Well2 and Well4): Only the inputs logs are
displayed, one track per family input.
• Validation wells (Well3 and Well9): There is an additional
pink curve per input track to check the quality of the
computation. Each pink curve is the result of the well predict
calculation by the other reference wells.

Techlog Fundamentals, Version 2012 313


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

• Prediction wells (Well1): The first tracks display each curve


stretched and squeezed from the reference and the
validation wells that are sorted by input types.
The last tracks show the computation results with the
curves predicted in blue. These output curves are
displayed with an uncertainty in light blue (variance of all
the well-by-well predictions).
© 2011-2013 Schlumberger. All rights reserved.

12. Align the wells using the ZoneD Top.

13. Activate Automatic launch. Any modification made in


the table (new input, modification of parameters) will be
reflected in real time on the layout.
14. Modify the smoothing window size (use 2, 5, and10) and
observe the results. Then drag the measured GAMM, SONI,
and DENS variables into the layout and compare the Well
predict result with the actual measurements.
15. Save the results.
a. Select Well predict method in the Workflow overview
window.
b. Open the Properties window.

314 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

c. In the Output variables tab, enter a prefix (WP_).

© 2011-2013 Schlumberger. All rights reserved.


d. Change the Apply mode to save and display and click
to launch the Well predict method. The created variables
are displayed in the DATAFULL data set in Well1.

Techlog Fundamentals, Version 2012 315


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

16. Save the workflow.


a. In the Workflow manager, on the Save tab, select Save
Workflow….
b. Enter a name for the Workflow (WellPredict) and
select to save the workflow parameters.
© 2011-2013 Schlumberger. All rights reserved.

c. Click Save. The WellPredict workflow now is saved in your


Project browser.

Review Questions
• Do you need an Index data set to display the well trajectory?
• In Well predict, do you need validation wells?
• Can you display several wells in 3D view?

316 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Well Trajectories, Field Map, and Well Predict

Summary
In this module, you learned about:

• displaying the well trajectory in a 2D display


• displaying the wells on a geographic map
• displaying wells in 3D view
• using the Application Workflow Interface for the Well predict
method.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 317


Well Trajectories, Field Map, and Well Predict Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

318 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Module 10 Depth Shifting Tool and


Variables Splice Tool
The Depth shifting tool allows you to depth match logs according
to a reference log. The Variables splice tool splices together
continuous curve sections from different data sets in a well into a
single curve.

Learning Objectives
After completing this module, you will know how to:

• manually and automatically create a depth shifting window


• depth shift a variable and a data set
• use the Variables splice tool

© 2011-2013 Schlumberger. All rights reserved.


• make selections in the Properties window
• create a data set.

Lesson 1 Manual Depth Shifting

To correct a tool string shift, it might be necessary to depth shift


several curves or an entire data set. This results in a curve being
shifted up or down. This lesson shows you how to shift a curve or
a data set manually.

Procedure 1 Creating a Depth Shifting Window

Several procedures can be applied to depth shift a curve. This


procedure shows you how to depth shift a variable from a layout
graphically.

1. Choose two logs: a reference log and a log to shift.


2. Drag the two curves into an empty LogView layout.
3. Select the two curves.

Techlog Fundamentals, Version 2012 319


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

4. In the Open drop-down list, select Open a depth shifting


window.
A layout is generated automatically, as shown in the figure.

• The first track displays the log-to-depth shift.


NOTE: In this track, the curve cannot be modified.

• The second track displays the reference log.


• The third track displays the log to depth shift. It is only in this
track that the curve can be depth shifted.
The last track also displays the log to depth curve, as well
as the reference log to help you to depth match the curve
accurately.
© 2011-2013 Schlumberger. All rights reserved.

320 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Procedure 2 Depth Shifting a Log

The Depth shifting tool allows you to depth match logs according
to a defined reference log. After you create the Depth shifting
window, you will be able to manually shift your log.

1. Hold down the Shift key and left-click in one of the two first
tracks.
At each click, a red anchor bar appears.

2. Position the cursor on one of the bars at the Log level.


3. Shift the log by moving the cursor up and down while holding
down the left mouse button.

Important Points
You should keep in mind several important points when depth

© 2011-2013 Schlumberger. All rights reserved.


shifting a log:

• When only one anchor bar is present, the depth shifting is


equivalent to a block shift, because the curve is displaced in
one block.
• When two or more anchor bars are present, the depth
shifting is equivalent to stretching, because one of the bars
locks the curve.
• The depth shifted curve automatically takes the name of the
curve with the suffix _sft.
• To remove an anchor bar, click on it and press Delete.
• It is possible to zoom in or zoom out at any time during the
operation.

Techlog Fundamentals, Version 2012 321


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

Procedure 3 Saving the Depth Shift

After you are satisfied with a depth shift, you can save the curve
and the applied depth shifting.

1. Click on the curve.


2. In the Save drop-down list, select The variable....
3. In the Save drop-down list, select The depth shifting table....
4. When a window opens, enter a name for this depth shifting.
The name you enter is applied to a set in which all
characteristics of the depth shifting are saved.

Procedure 4 Applying a Depth Shifting

This function allows you to apply a saved depth shift table to a


variable or a reference.
© 2011-2013 Schlumberger. All rights reserved.

1. In the Project browser, choose a curve to shift.


2. Using the contextual menu, apply the depth shift to either a
variable or the reference of the data set.
• If applied to the variable, only the variable will be depth
shifted according to the applied table.
• If applied to the reference, the entire data set will be depth
shifted according to the applied table.
TIP: Depth shifting is applied automatically to all of the
curves that you have selected.

322 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Procedure 5 Block Shifting a Curve (Special


Feature)

It is possible to vertically shift, for example, a log to match two


curves before splicing them.

1. Select the curve.


2. Hold down the Shift key while using the top and bottom
arrows on the keyboard to move the curve.
WARNING: The shifted curve is not automatically saved.

3. Right-click on the curve and select Save.

Procedure 6 Applying a Horizontal Shift to a


Curve

© 2011-2013 Schlumberger. All rights reserved.


It is possible to laterally shift, for example, a log to match two
curves before splicing them.

1. Hold down Ctrl + Alt and click on the curve.


2. Move the cursor from left to right, or from right to left.

Lesson 2 Automatic Depth Shifting

Automatic depth shifting automatically computes the depth shift


between two logs and displays the computed shift bars in a depth-
shift layout. You can adjust or remove the computed shift bars as
desired.

Procedure 1 Automatically Depth Shifting a


Curve

Drag two variables (log curves) into a multi-well layout. The


variable can be from the same data set or from different data sets
within the same well.

1. Choose two curves.


2. From the Open drop-down list, select Open the depth shift
window.

Techlog Fundamentals, Version 2012 323


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

3. In the Depth shifting window, select Edit > Automatic


definition of the depth shift table.
This action calculates and displays the depth bars between
the curves.
© 2011-2013 Schlumberger. All rights reserved.

324 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Properties Window
You can adjust depth-shift correlations by modifying parameters
contained in the depth-shift Properties window (Figure 84),
located on the Automatic shift tab.

© 2011-2013 Schlumberger. All rights reserved.


Figure 84 Properties window for depth shifting

Techlog Fundamentals, Version 2012 325


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

Automatic Shift Properties


This table describes the properties that you can set in the depth
shifting Properties window.

Automatically Automatically launches the depth-shift


apply procedure when properties are modified.
Correlation When the correlation coefficient between two
cut-off sequences is below this value, the sequences
will be ignored in the depth shift.
Smooth The automatic depth shift makes two passes:
windows
• A low-resolution pass using a large
window size (Smooth window 1).
• A high-resolution pass using a small
window size (Smooth pass 2).
© 2011-2013 Schlumberger. All rights reserved.

Window size Length of the correlation sequence,


specifically, the number of depth positions.
Shift size Designated shift above and below the
sequence.
Correlation Correlation, anti-correlation, or both.
type
Outliers cut- Increases or decreases the number of shifted
off depth positions. Smooths the signal by
reducing noise.
Remove Eliminates noise resulting in a smoother
outliers shift signal.
Shift outliers Eliminates noise resulting in a smoother
threshold signal.

WARNING: The shifted curve is not saved automatically. To


save it, right-click on the curve and select Save.

326 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Exercise 1 Depth Shifting a Variable

Before starting this exercise, upload data from the


TECHLOG_2012\Exercises\03 Depth shift, Splice, Variable
processing folder.

In this exercise, you use the Depth shift tool to shift the core
porosity variable C_PHI in Well 4, data set RUN2. As a reference,
use the log porosity PHIT_DK.

1. Drag the C_PHI and PHIT_DK into a new empty layout.

© 2011-2013 Schlumberger. All rights reserved.

2. Compare the two variables.

Techlog Fundamentals, Version 2012 327


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

3. Because the variables have different scales, adjust the


C_PHI scale.
© 2011-2013 Schlumberger. All rights reserved.

4. Select the core porosity variable C_PHI (the variable you


wish to shift), then select the continuous porosity variable
PHIT_DK (your reference variable).

328 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

5. Right-click and select Open > Depth shift window.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 329


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

6. Using log porosity as a reference, notice the shift that exists


between these two curves.
© 2011-2013 Schlumberger. All rights reserved.

7. Insert a depth shifting anchor by pressing Shift + left-click.


8. Adjust the core porosity variable to fit the two curves.

9. In the Depth shifting window, right-click and select Save >


The depth shift table.
10. Keep the default name <Shift_RUN2> and click Save. A new
data set is created.

330 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Procedure 2 Depth Shifting a Variable from the


Project Browser

You can also depth shift the variable from the Project browser.

1. Right-click on the variable and select Apply one depth shift


table on the variable….

© 2011-2013 Schlumberger. All rights reserved.


2. Select the Save as new version option and click OK.

Techlog Fundamentals, Version 2012 331


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

3. Choose the depth shift table you wish to apply on the


variable and click OK.
© 2011-2013 Schlumberger. All rights reserved.

The shifted variable is now created and displayed in your


Project browser.

332 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Procedure 3 Depth Shifting a Variable from the


Layout

This procedure shows you how to depth shift a variable from the
LogView layout.

1. Select the variable you want to shift (C_PHI) in the LogView


layout.
2. Select Processing Depth shifting > On the variable.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 333


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

3. Choose the depth shift table <Shift_RUN2> and click OK.


A temporary shifted variable is created and designated with
an asterisk (*) to the right of the name. In the layout, the
ghost points also are displayed as gray points.
© 2011-2013 Schlumberger. All rights reserved.

4. Right-click on the modified variable to save it from the layout.

334 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Exercise 2 Depth Shifting a Data Set

The data sets RUN2 and RUN3 are not correctly adjusted. If you
compare the GAMM from RUN2 and RUN3 in a layout, you will
notice a small shift as shown in the figure.

© 2011-2013 Schlumberger. All rights reserved.


In this exercise, you depth shift the RUN3 data set to correct this
shift.

1. Drag GAMM data from RUN2 and RUN3 into a LogView


layout.
2. Select the two gamma ray curves in the layout. Select the
curve you want to shift first, then select the reference curve.
3. Right-click and select Depth shift window.
4. Press Shift + left-click to insert a depth shift line.

Techlog Fundamentals, Version 2012 335


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

5. Move the line to fit the two logs.


© 2011-2013 Schlumberger. All rights reserved.

6. Save the depth shift table. As in the Exercise 1, a depth


shifting data set is created in your project. It is named
Shift_RUN3, unless you modify the name.
7. In the Project browser, select the data set RUN3, right-click
and select Apply one depth shift table on the reference.

336 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

You can choose not to create a new data set, or you can add
a suffix to the new data set that you create.

8. Select the correct Depth shift table to be applied:


Shift_RUN3.
A new data set is created in your Project browser. If you
choose No, the depth shift table is applied on the data set

© 2011-2013 Schlumberger. All rights reserved.


reference. The old data set reference is retained, but it is
renamed MD_original.

Techlog Fundamentals, Version 2012 337


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

Variables Splice Tool


The Variables splice tool in the Data menu allows you to splice
variables from different data sets.

In the Limits tab, the Variable splice tool creates a table with one
line for each output variable and four columns for each input
curve:

• Position: Merging priority


• Dataset.variable: Name of the data set concatenated with the
name of the variable.
• Top: Depth used as the top of the interval of interest for this
variable. The value entered cannot be above the top of the
data set.
• Bottom: Depth used as the bottom of the interval of interest
© 2011-2013 Schlumberger. All rights reserved.

for this variable. The value entered cannot be below the


bottom of the data set.

338 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Procedure 4 Splicing Data Sets in the Variables


Splice Tool

This procedure shows you how to use the Variables splice tool to
splice data sets.

1. In the Data menu, select Variables splice tool.

2. Drag the data sets into the Graphic variable splice table
window, as shown in the figure.

© 2011-2013 Schlumberger. All rights reserved.


The splice table automatically fills with default values.

Each line provides one output per variable with the same
name, family, and alias, according to the group type.

3. Modify the group type in the Variable splice tool Properties


window.

Techlog Fundamentals, Version 2012 339


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

4. Set the Type property under Groups to variables.


The Variable splice tool table appears with data in all cells.

5. Check these settings in the Properties window and click


Apply.
• The Apply mode can be set to Display, Save, or Save and
Display.
• Variables can be grouped by variables, family, or alias
name.
© 2011-2013 Schlumberger. All rights reserved.

• Splice overlap controls the method that combines the


curves: either position or mean. If gaps exist, they are filled
by Iinear interpolation, missing values, a constant, or a top
or bottom value.

340 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

You can output results to a new data set with a specified


name or overwrite an existing data set. You also can assign a
suffix and set controls on the sampling rate and reference
unit in the Properties window.

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 341


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

6. Click in the lower right corner of the workflow.

By activating the automatic launch button you can


modify the limits of each log and control the output in the
resulting log graphically, as shown in the figure, or in the
table.

The group of tracks on the left corresponds to a line in the


table; one track is created per variable to be spliced. The last
track on the right shows the result of the splice.
© 2011-2013 Schlumberger. All rights reserved.

342 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

Exercise 3 Creating a Data Set

In this exercise, you use the Variable splice tool to create a data
set containing all the data coming from RUN1, RUN2, RUN3, and
RUN4 in Well4.

1. From the Data menu, select Variable splice tool.


2. Drag the RUN1, RUN2, RUN3, and RUN4 data sets from
Well4 into the Graphic variable splice table window.
3. In the Properties window, set Type to variables. This groups
variables by variable name.
4. In the drop-down menu on the bottom right, select Display
and activate Automatic launch .

5. Click .
A layout appears for each variable with four input tracks and

© 2011-2013 Schlumberger. All rights reserved.


one output track. Notice that between RUN1 and RUN2,
there is no gap or overlap, but between RUN2 and RUN3
there is. The priority is given to RUN2.

6. Because the splicing priority goes from the left to the right,
you might need to switch some input curves. Select one track
and use the arrow keys to move the track left or right. The
Position column is updated automatically in the table.
7. Edit splicing intervals graphically by hovering the mouse over
a limit and dragging it to the required depth.
The splice table is updated on the fly.

8. Remove inputs and intervals by selecting them and pressing


Delete.
TIP: You can select multiple intervals on the same track on
the layout by using the button and drawing the
intervals on the track.

9. When you are satisfied with the merging, set the Display
mode to Save and click .
A new merged data set is created. Notice that the point data
variable cannot be spliced.

10. Keep core porosity in the final data set. In the Project
browser, drag C_PHI data from RUN2 into Merged_Set.

Techlog Fundamentals, Version 2012 343


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

The Resampling tool opens automatically because each


data set is defined by the reference depth, top and bottom
depths, and sample rate.

When moving a variable from one data set to another, all the
data must conform to the new data set.

11. Click Apply to place the point variable into the final data set.

Review Questions
• What is the purpose of the depth shifting table?
• What are the two options to shift data?
• What is the purpose of the Variable splice tool?
• What is the correct order for selecting the depth shifting
variables?
© 2011-2013 Schlumberger. All rights reserved.

• When you are satisfied with your depth shifting and you save
it, what do you do next?
• When performing a splice, how can you change the variables
grouping type to work with families instead of variables?

Summary
In this module, you learned about:

• creating a depth shifting window both manually and


automatically
• depth shifting a variable and a data set
• using the Variable splice tool
• using a splice table
• creating a data set.

344 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Depth Shifting Tool and Variables Splice Tool

NOTES

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 345


Depth Shifting Tool and Variables Splice Tool Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

346 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

Module 11 Project Data


Management
Project data management is a collection of tools that help you
manage and perform quality control on data.

Prerequisites
To successfully complete the lessons and exercises in the
module, you must import these XML files into the project from
\Techlog_2012\Exercises\02 Data Harmonization Exercise\:

• Well1_Harmonization_Exercise.xml
• Well2_Harmonization_Exercise.xml
• Well3_Harmonization_Exercise.xml

© 2011-2013 Schlumberger. All rights reserved.


• Well4_Harmonization_Exercise.xml.

Learning Objectives
After completing this module, you will know how to:

• identify inconsistent units and families in data using the quick


data mining tools in Techlog
• use the Data harmonization tools to rename variables and
families and assign and convert units.

Lesson 1 Project Browser Optimization

The Inventory tools list all of the variables present in the Project
browser. To refine the inventory and focus on only the data
corresponding to this exercise, create a filter on the data set
named Harmonization_Exercise.

Techlog Fundamentals, Version 2012 347


Project Data Management Schlumberger Internal Use Only

Exercise 1 Creating a Filter

In this exercise, you create a filter on a data set named


Harmonization_Exercise.

1. Choose the data set Harmonization_Exercise in Well1.


2. Take one of these actions to create the filter:

• Right-click and select Create a filter .


• Press Ctrl + J.
The Project browser opens.

Lesson 2 Issues in the Data Sets

Several tools are available that help you identify and correct
© 2011-2013 Schlumberger. All rights reserved.

problems in the data.

Project Browser
You can use the Project browser to identify variables with
missing units and families quickly.

• Variables displayed in black have a unit and a family


assigned to them.
• Variables displayed in gray are missing a unit or a family.
• Variables displayed in red are missing a unit and a family
(Figure 85).
• Families displayed in red are not defined in the family
database.

348 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

The Project browser, however, will not allow you to identify


inconsistent units or families. Also, it is not effective when working
on a large number of wells or data sets.

Figure 85 Variables list in the Project browser

Inventory Tools

© 2011-2013 Schlumberger. All rights reserved.


Open the Inventory tools (Figure 86) by selecting Data >
Techdata+ > Quick data mining.

Figure 86 Inventory tools

Techlog Fundamentals, Version 2012 349


Project Data Management Schlumberger Internal Use Only

Variables Inventory
Select Variables inventory to display an inventory. There is one
line for each variable name.

The first variable name, CALI, has these properties:

• It is present in the four data sets (Count into the data sets =
4).
• It is present in the four wells (Count into the wells = 4 and
Wells were present = All).
• The minimum value for CALI (within all the wells) is 8.163 in.
• The maximum value for CALI (within all the wells) is 15.651
in.
• All the CALI variables have the same unit (Count unit = 1).
• All the CALI variables have the same family, Caliper (Count
family = 1 and Family = Caliper).
© 2011-2013 Schlumberger. All rights reserved.

The Variables inventory is an efficient tool for identifying non-


homogenous names and inconsistent units.

The goal is to make sure that each variable:

• is present with the same name in 100% of the wells


• has a minimum and maximum value consistent with its unit
• has one known unit (Count Unit =1)
• has one family assigned (Count Family = 1).
Other inventories allow you to focus directly on the items
mentioned.

Other Lists and Inventories


Other lists and inventories are available that allow you to quickly
identify issues such as:

• missing units: variables without unit inventory


• missing families: variables without families inventory
• inconsistent families: families not present in the families
database inventory.

350 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

To add lists and inventories as tabs in the Quick data mining


window, go to the Properties window (Figure 87) and select yes
to activate the relevant lists and inventories.

© 2011-2013 Schlumberger. All rights reserved.


Figure 87 Properties window

For example, Variables without unit inventory (Figure 88) can


show a unit issue that you could not see easily in the variable
inventory display in variable CKH.

Figure 88 Variables without unit inventory display

Variable CKH in Well2 has no unit (Count Unknown unit =1 and


Wells where present = Well2).

Techlog Fundamentals, Version 2012 351


Project Data Management Schlumberger Internal Use Only

Exercise 1 Identifying Issues in a Data Set

In this exercise, you use the various lists and variables available in
Techlog to identify the units, families, and erroneous values
present in the data set named Harmonization_Exercise.

NOTE: These issues will be fixed in the next lesson.

1. Create a filter on the data set Harmonization_Exercise in the


Project browser.
2. Open the variables inventories from the Techdata menu.
3. Open the Variables without unit inventory as a tab in the
Quick data mining window.
4. Open the Variables without families inventory as a tab in the
Quick data mining window.
5. In the Variables without unit inventory tab, notice these
© 2011-2013 Schlumberger. All rights reserved.

issues:
• The variable CKH in Well2 is missing a unit. The unit should
be mD.
• The variable RHOB_DH_ADN_RT is missing a unit. The
unit should be g/cc.
• The variables RT and RW have an unknown unit. The unit
should be ohm.m.
• The variable TNPH_ADN_RT is missing a unit. The unit
should be v/v.
6. In the Variables without families inventory tab, notice
these issues:
• MDepth is missing a family. The family should be Measured
Depth.
• RHOB_DH_ADN_RT has an unknown family. The family
should be Bulk Density.
7. In the Variables inventory tab, notice these issues:
• The name for the gamma ray variables is not harmonized.
In Well1, the gamma ray is named
GR_CDR_RAW_RT_backup, while the gamma ray
variables are named GR_CDR_RAW_RT in the other wells.
• The gamma ray variables have three units: gAPI, gapi, and
µR/h.

352 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

• The variables in CPOR do not all have the same family.


Some have the family Core Porosity, while others are
assigned the family Fast Shear Uncertainty. The second
family has not been assigned correctly and should be set to
Core Porosity.
• The variable HAFWL has two units: m and ft. All units
should be harmonized to ft.
• According to naming conventions, the variable MDepth
should be renamed MD.
• The family should be Measured Depth.
• The unit of the variable MDepth is not consistent with the
values of the variable (> 8,000 m, while the TVDSS is below
8,200 ft). The unit should be set to ft.
• The variable VSH has values inconsistent with its unit. The
unit is v/v, meaning that the values should range between 0

© 2011-2013 Schlumberger. All rights reserved.


and 1. The erroneous values must be clipped.

Techlog Fundamentals, Version 2012 353


Project Data Management Schlumberger Internal Use Only

Lesson 3 Data Harmonization

You can perform the harmonization of data (renaming, assigning


and converting units, and assigning families) in three ways:

• Sequentially solving one problem after the other using the


Project browser
• Automatically using the Inventory tools
• Using Data harmonization tools.

Data Harmonization using the Project browser


In the Properties window (Figure 89), you can manually change
properties such as the unit or the family of a variable. Many of the
properties have drop-down menus from which to choose, while
others require that you enter a value or term.
© 2011-2013 Schlumberger. All rights reserved.

Figure 89 Properties window

354 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

Procedure 1 Performing Data Harmonization


using the Inventory Tool

With the Inventory tool, you can do basic data manipulation, such
as renaming a variable or assigning a family.

1. Select a variable name and click the Rename icon .(or


press F2).
2. Enter a new name for the variable in the Quick rename
dialog box and click OK.

© 2011-2013 Schlumberger. All rights reserved.


3. Similarly, to assign a family, select a variable name and click
on the Family icon .

Data Harmonization using Data Harmonization


Tools
The Data harmonization tools (Figure 90) are accessed from the
Data >Techdata+ menu.

Figure 90 Data harmonization menu

Techlog Fundamentals, Version 2012 355


Project Data Management Schlumberger Internal Use Only

The harmonization tools offer these capabilities:

Query Rename any object or property within your


rename tool project (Figure 91).

Example: A wrong unit is assigned to a variable.


The values are supposed to be displayed in
percentage but, instead, are displayed in a v/v
unit. Rename the unit v/v to %.
Query Convert any unit (Figure 93).
convert tool
Example: CALI variables are supposed to be
displayed as inches (in) but, instead, are
displayed as centimeters (cm). You can convert
the CALI variables from cm to in to have
harmonized units.
Query Delete any object or property.
© 2011-2013 Schlumberger. All rights reserved.

delete tool
Example: Some variables must be deleted from
all the wells.
Query Duplicate any object or property.
duplicate
tool Example: Create a backup of your variables
before processing them.
Query list List any object or property.
tool
Example: Create a list of all the variables in the
project named DT.
Query data Replace or remove numeric values for any
tool curve (Figure 94).

Example: Some values of the variables are


erroneous (negative porosity, for example) and
must be removed.

356 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

Data Harmonization Tools Scenarios


This section contains a series of short scenarios that show you the
primary ways in which Data harmonization tools can be used.

Query Rename Tool


Scenario: Rename the variable MDepth to MD.

All variables named MDepth in the data set


Harmonization_Exercise will be renamed to MD.

WARNING: Always click Preview before renaming objects.


There is no undo function in Techlog.

© 2011-2013 Schlumberger. All rights reserved.


Figure 91 Options in the Query Rename Tool dialog box

Scenario: Rename the unit of the variable MD from M to ft.

The object type is now Variable unit. You must apply a filter on the
variable named MD to avoid renaming the unit of other variables
(Figure 92).

Techlog Fundamentals, Version 2012 357


Project Data Management Schlumberger Internal Use Only

All variable units M in the variable MD in the data set


Harmonization_Exercise will be renamed to ft.
© 2011-2013 Schlumberger. All rights reserved.

Figure 92 Query Rename Tool window

358 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

Query Convert Tool


Scenario: The units of the variable GR_CDR_RAW need to be
converted to gAPI.

All variables named GR_RAW_CDR_RT will be converted to


gAPI.

© 2011-2013 Schlumberger. All rights reserved.


Figure 93 Query Convert Tool window

Techlog Fundamentals, Version 2012 359


Project Data Management Schlumberger Internal Use Only

Query Data Tool


Scenario: The erroneous values of the variable VSH must be
removed.

All values of the variable VSH below 0 will be set to -9999.


© 2011-2013 Schlumberger. All rights reserved.

Figure 94 Query Data Tool window

360 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

Data Harmonization Exercises


In these exercises, you use the Data harmonization query tools
to repair data harmonization issues based on the scenarios
defined in each exercise.

Exercise 1 Correcting a Missing Unit for a


Variable in a Well

Scenario: The variable CKH in Well2 is missing a unit. The unit


should be mD.

1. Open the Query rename tool.


2. Set the Object type to Variable unit.
3. Set the After field to mD.

© 2011-2013 Schlumberger. All rights reserved.


4. Set a Well filter to Well2.
5. Set a variable filter to CKH.
6. Click Preview and click Rename.

Exercise 2 Correcting a Missing Unit for


Variable RHOB_DH_ADN_RT

Scenario: The variable RHOB_DH_ADN_RT is missing a unit.


The unit should be g/cc.

1. Open the Query rename tool.


2. Set the Object type to Variable unit.
3. Set the After field to g/cc.
4. Set a variable filter to RHOB_DH_ADN_RT.
5. Click Preview and click Rename.

Exercise 3 Correcting an Unknown Unit

Scenario: The variables RT and RW have an unknown unit. The


unit should be ohm.m.

1. Open the Query rename tool.


2. Set the Object type to Variable unit.
3. Set the Before field to OHM_PER_M.

Techlog Fundamentals, Version 2012 361


Project Data Management Schlumberger Internal Use Only

4. Set the After field to ohm.m.


5. Set a variable filter to RT.
6. Click Preview and click Rename.
7. Repeat the same operation for the variables RW.
TIP: A quicker way to do this is to create a conditional
selection in your Project browser on RT and RW, then
apply a filter. Then you can use the Query rename tool
to change the unit.

An alternate method is to write a filter in the Properties


window of the Query rename tool. In the Properties
window, you can select two types of expression: basic (DOS)
and complex (UNIX/Perl).
© 2011-2013 Schlumberger. All rights reserved.

For this example you can select complex and insert R[T|W]
in the Filter section in the Variable field. All syntax
expressions are available in the Techlog Help file. RT and
RW variables will be selected automatically.

362 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

Exercise 4 Correcting a Missing Unit for


Variable TNPH_ADN_RT

Scenario: The variable TNPH_ADN_RT is missing a unit. The


unit should be per fraction.

1. Open the Query rename tool.


2. Set the Object type to Variable unit.
3. Set the After field to v/v.
4. Set a variable filter to TNPH_ADN_RT.
5. Click Preview and click Rename.

Exercise 5 Correcting a Missing Family

Scenario: MDepth is missing a family. The family should be

© 2011-2013 Schlumberger. All rights reserved.


Measured Depth. Additionally, to be consistent with other data
sets, this variable should be renamed MD.

1. Open the Query rename tool.


2. Set the Object type to Variable family.
3. Set the After field to Measured Depth.
4. Set a variable filter to MDepth.
5. Click Preview and click Rename.
6. Set the Object type to Variable name.
7. Set the Before field to MDepth and the After field to MD.
8. Click Preview and click Rename.

Exercise 6 Correcting an Unknown Family

Scenario: RHOB_DH_ADN_RT has an unknown family. The


family should be Bulk Density.

1. Open the Query rename tool.


2. Set the Object type to Variable family.
3. Set the Before field to Bulk Density LWD.
4. Set the After field to Bulk Density.
5. Click Preview and click Rename.

Techlog Fundamentals, Version 2012 363


Project Data Management Schlumberger Internal Use Only

Exercise 7 Correcting a Variable Assigned to


Multiple Families

Scenario: The variables CPOR are assigned to various families.

1. Open the Query rename tool.


2. Set the Object type to Variable family.
3. Set the Before field to Fast Shear Uncertainty.
4. Set the After field to Core Porosity.
5. Click Preview and click Rename

Exercise 8 Correcting a Variable that is not


Harmonized

Scenario: The name for the gamma ray variable is not


© 2011-2013 Schlumberger. All rights reserved.

harmonized.

1. Open the Query rename tool.


2. Set the Object type to Variable name.
3. Set the Before field to GR_CDR_RAW_RT_backup.
4. Set the After field to GR_CDR_RAW_RT.
5. Click Preview and click Rename.

Exercise 9 Correcting a Variable that has Two


Units

Scenario: The variable HAFWL has two units, m and ft.

1. Open the Query convert tool.


2. Set the Object type to Variable unit.
3. Set the Before field to m.
4. Set the After field to ft.
5. Set a variable filter to HAFWL.
6. Click Preview and click Convert.

364 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

Exercise 10 Correcting a Variable that has an


Incorrect Unit

Scenario: The variable MD is in M, but it should be ft.

1. Open the Query convert tool.


2. Set the Object type to Variable unit.
3. Set the Before field to M.
4. Set the After field to ft.
5. Set the variable filter to MD.
6. Click Preview and click Convert.

Exercise 11 Adding a Suffix to Variables

Scenario: The variables DENC, GR_CDR_RAW_RT,

© 2011-2013 Schlumberger. All rights reserved.


RHOB_DH_ADN_RT, and RT should be followed by _up.

1. In the Project browser, select these four variables in Well4.


2. Create a conditional selection and create a filter.
3. Open the Query rename tool.
4. Set the Object type to Variable name.
5. Ensure that the regular expression type in the Properties
window is set to simple (DOS).
6. Set the Before field to *.
7. Set the After field to %VariableName%_up.
8. Click Preview and click Rename. The selected variables
now have the _up suffix.

Exercise 12 Correcting a Value that is


Inconsistent with its Unit

Scenario: The variable VSH has values inconsistent with its unit.
Several values lower than 0 and higher than 1 are present. These
values should be replaced by the absent value.

1. Open the Query data tool.


2. Set the Object type to Variable.
3. Set the Before field to Data < 0.

Techlog Fundamentals, Version 2012 365


Project Data Management Schlumberger Internal Use Only

4. Set the After field to -9999.


5. Set a variable filter to VSH.
6. Click Preview and click Edit.
7. Set the Before field to Data > 1.
8. Click Preview and click Edit.

Review Questions
• Which tool would you use to change all -999.25 to -9999?
• What can you do if one of the units is degrees and is not
recognized by Techlog?
• How can you see the list of variables present in a project?
• To make a change in the family name at the project level,
which harmonization tool would you use?
© 2011-2013 Schlumberger. All rights reserved.

• Which harmonization tool would you use to convert the


temperature of several wells from Celsius to Fahrenheit?
• Can you add a suffix to all variables in a data set?

Summary
In this module, you learned about:

• identifying inconsistent units and families in the data using


the Quick data mining tools in Techlog
• using the Data harmonization tools to rename variables and
families and assign and convert units.

366 Techlog Fundamentals, Version 2012


Schlumberger Internal Use Only Project Data Management

NOTES

© 2011-2013 Schlumberger. All rights reserved.

Techlog Fundamentals, Version 2012 367


Project Data Management Schlumberger Internal Use Only

NOTES
© 2011-2013 Schlumberger. All rights reserved.

368 Techlog Fundamentals, Version 2012

You might also like