Professional Documents
Culture Documents
ELECTRIC ACTUATORS
for industrial applications and civil vessels
BASIC RANGE
SBA 06 – SBA 200
NR 2.1 – NR 2.3
ED 25 – ED 450 / EQ 60 – EQ 600
SMART RANGE
SD 05 – SD 25 / SDL 50 – SDL 100 SGC
04.1 – SGC 12.1
SGCR 04.1 – SGCR 12.1
SVC 05.1 – SVC 07.5
SVCR 05.1 – SVCR 07.5
Manual
Technical documentation
1st edition 2017
4 Dimensions Actuators 91
Basic Range 92
Smart Range 102
Basic Range 6
Smart Range 14
Type Stroke Operating Motor Valve attachment Trapezoidal Positioning speed2) Weight
force protection1) thread
Standard
Max. EN ISO 5210 approx.
[mm] [kN] DIN 3210 [mm/min] [kg]
8
SBA 06-1 0.6 B F05 8 x 1,5 2.1
10
35 13.2
SBA 06-2 0.9 B F05 8 x 1,5 2.1
16
SBA 06-3 1.2 B F05 8 x 1,5 20 2.1
8
SBA 06-4 35 2.0 B F05 10 x 2 10 2.1
13.2
SBA 12 75 1.2 B F05 14 x 3 25 8.0
SBA 20 75 2.0 B F05 14 x 3 15 8.0
25
SBA 45-2 75 3.5 B F05 14 x 3 8.0
50
25
SBA 45-3 75 4.5 B F05 14 x 3 8.0
50
17
SBA 45-4 75 6.0 B F05 14 x 3 8.0
34
SBA 80-1 6.0 B G0 20 x 4 13.5 13
SBA 80-2 80 8.0 B G0 20 x 4 25 13
SBA 80-3 12 T G0 20 x 4 50 13
B 13.5
SBA 80-4 80 15 B G0 20 x 4 22 13
T 40
SBA 200-1 15 B G0 26 x 5 15 19
100 T 25
SBA 200-2 20 G0 26 x 5 19
T 50
SBA 200-3 100 25 T G0 26 x 5 25 19
General information
Linear actuators for modulating and open-close automation
Notes on table
1) Motor protection B = stall-proof motor (S1 - 100 %), T = thermoswitch for temperature monitoring
2) 50 Hz For 60 Hz, operating times and power consumption increase by 20 %
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Options:
3-phase AC current 1-phase AC current
Voltages/frequencies Voltages/frequencies
Volt 380 400 400 440 Volt 24 24 115 110
Hz 50 50 60 60 Hz 50 60 50 60
DC current
Voltages
Volt 24
SBA 12 SBA 20 SBA 45-2/-3 SBA 45-4 SBA 80-1/-2/-3 SBA 80-4
2 x M16 x1.5 and 1 blanking plug M16 x 1.5
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Service conditions
Mounting position Any position, but not suspended downward
Installation altitude ≤ 2 000 m above sea level
> 2,000 m above sea level on request
Ambient temperature Standard: –20 °C to +60 °C
Options: –40 °C to +60 °C
Other options on request
Enclosure protection according to IP43 (SBA 06-1/-2/-3), IP54 (SBA06-4), IP65 (SBA 12 – SBA 200)
EN 60529
Corrosion protection Standard: C2 according to EN ISO 12944-2
Option: C3/C4 according to EN ISO 12944-2
Coating Standard: Powder coating
Option: Special coating for corrosion protection C3/C4
Colour Standard: Grey: RAL 7015 (housing)
Green: RAL 5021 (hood)
Option: Available colours on request
Lifetime AUMA linear actuators meet or even exceed the lifetime requirements of EN 15714-2.
Detailed information can be provided on request.
Further information
Inspection certificate On request
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions Linear actuators SBA 06 – SBA 200
Electrical data Linear actuators SBA 06 – SBA 200
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Technical data Linear actuators with fail safe unit for modulating duty
Type Stroke Operating force Motor Valve Positioning speed for Positioning speed at Weight
protection2) attachment modulating duty3) power failure
General information
Linear actuators for modulating and open-close automation with fail safe unit
Notes on table
1) Applicable for extending effective spring direction
2) Motor protection B = Stall-proof motor
3) 50 Hz For 60 Hz, operating times and power consumption increase by 20 %
Options:
1-phase AC current
Voltages/frequencies
Volt 24 24 115 110
Hz 50 60 50 60
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Technical data Linear actuators with fail safe unit for modulating duty
Service conditions
Mounting position Any position, but not suspended downward
Installation altitude ≤ 2 000 m above sea level
> 2,000 m above sea level on request
Ambient temperature –20 °C to +50 °C
Enclosure protection according to Standard: IP67
EN 60529
Option: IP65 with rounded hood [A-IP65]
Corrosion protection Standard: C2 according to EN ISO 12944-2
Option: C3/C4 according to EN ISO 12944-2
Coating Standard: Powder coating
Option: Special coating for corrosion protection C3/C4
Colour Standard: RAL 7030
Option: Available colours on request
Lifetime AUMA linear actuators meet or even exceed the lifetime requirements of EN 15714-2. Detailed information
can be provided on request.
Further information
Inspection certificate On request
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions Linear actuators NR 2.1 – NR 2.3
Electrical data Linear actuators NR 2.1 – NR 2.3
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Torque range Operating time Motor Valve attachment Handwheel Weight
for 90° in seconds protection2)
Open-close duty Modulating duty
max. max. Open-close duty Standard Ø approx.
[Nm] [Nm] 50 Hz1) EN ISO 5211 [mm] [kg]
15 B
ED 25 25 25 30 B F03, (F04)4), F05, F07 – 4.0
70 B
15 T
ED 50 50 50 30 B F03, (F04), F05, F07 – 4.0
70 B
15 B
EQ 40 40 20 30 B (F04)4), F05, F07, F10 100 7.5
60 B
20 T
EQ 60 60 40 30 T F05, F07, F10 100 7.5
60 B
203) B
EQ 100 100 60 30 T F05, F07, F10 100 7.5
60 T
203) T
EQ 150 150 80 303) B F05, F07, F10 100 7.5
60 T
403) T
EQ 300 300 180 803) B F07, F10, (F12)4) 100 15
160 T
803) T
EQ 600 600 300 F07, F10, (F12)4) 100 15
1603) B
General information
Part-turn actuators for controlling and automating final elements within the field of process engineering with swivel movements between 90° and
180° for e.g. butterfly valves, ball valves.
Notes on table
1) 50 Hz For 60 Hz, operating time reduces and power consumption increases by 20 %
2) Motor protection B = stallproof motor (S1 - 100 %), T = thermoswitch for temperature monitoring
3) Aluminium hood required for optional positioner
4) Offset by 45°, F12 on request
Options:
3-phase AC current 1-phase AC current
Voltages/frequencies Voltages/frequencies
Volt 380 400 400 440 Volt 24 24 115 110
Hz 50 50 60 60 Hz 50 60 50 60
DC current
Voltages
Volt 24
Insulation class E, B, F
Motor protection Stallproof motor or thermoswitch for temperature monitoring
Heater (option) Heating resistor with thermoswitch against moisture with automatic temperature regulation, max. 15 Watt,
supply voltage 24, 115, 230 V/50/60 Hz [HZ/WP]
Self-locking Yes
Swing angle (option) Standard: EQ: 90° ±15°
ED: 90°, 120°, 150°, 180°
Options: EQ: 120° ±15°
[SWE] 150° ±15°
180° ±15°
Cable entry EQ: 3 blanking plugs M20 x 1.5
ED: 2 blanking plugs M16 x 1.5
Manual operation EQ: Handwheel
ED: Emergency manual operation with hexagon socket
Electrical connection Standard: Internal terminal rail, for terminal assignment refer to terminal plan
Options: • Separate electrical terminal compartment at actuator with 32-pole terminal rail [ASK]
• Compact connector 10-pole silver/24-pole silver [KS1, KS3]
End positions EQ: Mechanical end stops, adjustable from outside
ED: None
Hood Standard: Polycarbonate (flammability class V0)
Option: Aluminium with inspection glass
Local controls (option), IP66 • MANUAL/AUTO change-over
• Rotary switch (non latching) for OPEN and CLOSE [VSE]
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Service conditions
Mounting position Any position, but not suspended downward
Installation altitude ≤ 2,000 m above sea level
> 2,000 m above sea level, on request
Ambient temperature Standard: –20 °C to +70 °C
Options: –40 °C to +70 °C
Other options on request
Enclosure protection according to Standard: IP67
EN 60529
Option: IP68 [A-IP68]
Explosion-protection (option) Ex II 3D IP65 T 150°C Dc [A-Ex]
Corrosion protection Standard: C2 according to EN ISO 12944-2
Option: C3/C4 according to EN ISO 12944-2
Coating Standard: Powder coating
Option: Special painting for corrosion protection C3/C4
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime AUMA part-turn actuators meet or even exceed the lifetime requirements of EN 15714-2.
Detailed information can be provided on request.
Further information
Inspection certificate On request
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions Part-turn actuators EQ 40 – EQ 600
Dimensions Part-turn actuators ED 25 – ED 50
Electrical data Part-turn actuators EQ 40 – EQ 600
Electrical data Part-turn actuators ED 25 – ED 50
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Output speed Torque range Motor Valve attachment Handwheel Weight
protection1)
Modulating
Open-close duty duty
Max. max. max. Standard Ø approx.
[rpm] [Nm] [Nm] EN ISO 5210 [mm] [kg]
SD 05 8 6 5 E F10 100/752) 8.0
SD 10 20 10 10 E F10 100/752) 8.0
SD 25 20 30 25 E F10 100/752) 8.0
General information
Multi-turn actuators for modulating and open-close automation
Notes on table
1) Motor protection E = electronic cut-out
2) Handwheel For ATEX / IECEx approvals
Options:
3-phase AC current
Voltages/frequencies
Volt 200 – 500 200 – 500
Hz 50 60
DC current
Voltages
Volt 24
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Status signals Collective fault signal 24 V DC, Imax. 60 mA, galvanically isolated
Configuration • Setting via remote:
- Initialisation/zero point reset
• Setting via DIP switches:
- Input signal/output signal
- Rising, falling signal
- Type of duty
• Setting via programming switches:
- Torque, speed, number of turns), type of seating, operating parameters, configuration parameters
Display (option) Display with 2x16 LCD blue [ANZ-DIS]
Service conditions
Positioning accuracy < 0.5 %
Mounting position Any position, but not suspended downward
Installation altitude ≤ 2 000 m above sea level
> 2,000 m above sea level on request
Ambient temperature Standard: –20 °C to +60 °C (SD 05/ D 10)
–20 °C to +55 °C (SD 25)
Options: –40 °C to +60 °C (SD 10)
–40 °C to +55 °C (SD 25)
Other options on request
Enclosure protection according to Standard: IP67
EN 60529
Option: IP68 [A-IP68]
Explosion protection according to II 2G EEx de IIB T4
EN 60079-1
Corrosion protection Standard: C2 according to EN ISO 12944-2
Option: C3/C4 according to EN ISO 12944-2
Coating Standard: Powder coating (weatherproof)
Option: Wet painting (explosion-proof)
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime AUMA multi-turn actuators meet or even exceed the lifetime requirements of EN 15714-2.
Detailed information can be provided on request.
Further information
Inspection certificate On request
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions Multi-turn actuators SD 05 – SD 25
Electrical data Multi-turn actuators SD 05 – SD 25
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Stroke Operating force Positioning speed1) Motor Valve attach- Trapezoidal Weight
protection2) ment thread
Open-close Modulating-
Max. duty Max. duty Max. Min. Max. Standard approx.
[mm] [kN] [kN] [mm/s] [mm/s] EN ISO 5210 [kg]
SDL 50-10 55 6.0 5.0 0.2 0.5 E F05 14 x 3 14
SDL 50-20 55 6.0 4.0 0.4 2.5 E F05 14 x 3 14
SDL 50-30 55 4.0 2.5 1.2 7.0 E F05 14 x 3 14
SDL 100-20 85 6.0 6.0 0.3 1.8 E F07 20 x 5 15
SDL 100-30 85 15 10 0.3 1.8 E F07 20 x 5 15
SDG 40-13 300 3.0 2.0 0.3 0.7 E F10 16 x 4 18
SDG 40-23 300 4.0 4.0 0.2 1.2 E F10 16 x 4 18
General information
Linear actuators for modulating and open-close automation
Notes on table
1) Positioning speed Maximum positioning speed and operating force cannot appear simultaneously.
2) Motor protection E = electronic cut-out
Options:
3-phase AC current
Voltages/frequencies
Volt 200 – 500 200 – 500
Hz 50 60
DC current
Voltages
Volt 24
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Control Analogue 0 – 10 V input impedance > 100 kOhm, 0/4 – 20 mA input impedance 50 Ohm
Control inputs 24 V DC, galvanic isolation Ri = 1,500 Ohm (I > 10 mA)
OPEN, CLOSE, MODE
Position feedback signals Analogue 0 – 10 V, 0/4 – 20 mA, load max. 500 Ohm via contactless sensor
Status signals Collective fault signal 24 V DC, Imax. 50 mA, galvanically isolated
Configuration Setting via remote:
- Initialisation/zero point reset
Setting via DIP switches:
- Input signal/output signal
- Rising, falling signal
- Type of duty
Setting via programming switches:
- Torque, speed, number of turns), type of seating, operating parameters, configuration parameters
Display (option) Display with 2x16 LCD blue [ANZ-DIS]
Service conditions
Positioning accuracy < 0.5 %
Mounting position Any position, but not suspended downward
Installation altitude ≤ 2,000 m above sea level
> 2,000 m above sea level on request
Ambient temperature Standard: –20 °C bis +60 °C (SDL 50-10/SDL 50-20/SDL 100-20/SDG 40-13/SDG 40-23)
–20 °C bis +55 °C (SDL 50-30/SDL 100-30)
Options: –40 °C bis +60 °C (SDL 50-10/SDL 50-20/SDL 100-20/SDG 40-13/SDG 40-23)
–40 °C bis +55 °C (SDL 50-30/SDL 100-30)
Other options on request
Enclosure protection according to Standard: IP67
EN 60529
Option: IP68 [A-IP68]
Explosion protection according to Option: II 2G EEx de IIB T4
EN 60079-1
Corrosion protection Standard: C2 according to EN ISO 12944-2
Option: C3/C4 according to EN ISO 12944-2
Coating Standard: Powder coating (weatherproof)
Option: Wet painting (explosion-proof)
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime AUMA linear actuators meet or even exceed the lifetime requirements of EN 15714-2.
Detailed information can be provided on request.
Further information
Inspection certificate On request
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions Linear actuators SDL 50 – SDL 100
Electrical data Linear actuators SDL 50 – SDL 100
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Operating time for 90° Torque range1) Running Valve attach- Valve shaft Handwheel Weight4)
in seconds torque2)/ ment
(adjustable in 9 steps) Modulating
torque3)
Max. Max. Standard Cylindrical Square Two-flat Ø Turns approx.
50 Hz/60 Hz [Nm] [Nm] EN ISO 5211 max. [mm] max. [mm] max. [mm] [mm] for 90° [kg]
SGC/SGCR 04.1 4 – 63 25 – 63 32 F05/F07 20 17 17 100 13.5 7.0
SGC/SGCR 05.1 4 – 63 50 – 125 63 F05/F07 20 17 17 100 13.5 7.0
SGC/SGCR 07.1 4 – 63 100 – 250 125 F07 25.4 22 22 125 13.5 10
SGC/SGCR 10.1 5.6 – 90 200 – 500 250 F10 38 30 27 160 13.5 15
SGC/SGCR 12.1 20 – 275 400 – 1,000 500 F12 50 36 41 125 35 25
Notes on table
1) Unseating torque The “Torque by-pass” function (can be activated) allows increasing the pre-set torque to 130 %. This increase
only applies during actuator start for an adjustable time period, allowing safer unseating of blocked valves.
2) Running torque Maximum permissible torque for 15 min. running time.
3) Modulating torque Maximum permissible torque for modulating duty
4) Weight Indicated weight includes part-turn actuator with controls, electrical connection in standard version, unbored
coupling and handwheel
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Service conditions
Mounting position Any position
Installation altitude ≤ 2 000 m above seal level
> 2,000 m above sea level on request
Ambient temperature –25 °C to +70 °C
Humidity Up to 100 % relative humidity across the entire permissible temperature range
Enclosure protection according to IP68
EN 60529 According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: maximum 8 m head of water
Duration of continuous immersion in water: Max. 96 hours
Up to 10 operations during continuous immersion
Modulating duty is not possible during continuous immersion
Pollution degree according to IEC Pollution degree 4 (when closed), pollution degree 2 (internal)
60664-1
Vibration resistance according to 2 g, from 10 Hz to 200 Hz
IEC 60068-2-6 Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be
derived from this. Not valid in combination with gearboxes.
GL approval (option) Environmental categories D, G, EMC2
Corrosion protection Standard: KS Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
Option: KX Suitable for use in areas with extremely high salinity, permanent condensation, and
high pollution.
Coating Double layer powder coating
Two-component iron-mica combination
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime Open-close 20,000 operating cycles OPEN - CLOSE - OPEN
duty: An operating cycle is based on an operation from CLOSED to OPEN and back to CLOSED, at a
respective rotary movement of 90°.
Modulating 5 million modulating steps
duty:
The lifetime depends on the load and the number of starts. A high starting frequency will rarely improve the
modulating accuracy. To reach the longest possible maintenance and fault-free operating time, the number of
starts per hour chosen should be as low as permissible for the process.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Further information
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions SGC 04.1– SGC 12.1/SGCR 04.1 – SGCR 12.1
Electrical data SGC 04.1– SGC 12.1/SGCR 04.1 – SGCR 12.1
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Operating time for 90° Torque range1) Running Valve attach- Valve shaft Handwheel Weight4)
in seconds torque2)/ ment
(adjustable in 9 steps) Modulating
torque3)
Max. Max. Standard Cylindrical Square Two-flat Ø Turns approx.
50 Hz/60 Hz [Nm] [Nm] EN ISO 5211 max. [mm] max. [mm] max. [mm] [mm] for 90° [kg]
SGC/SGCR 04.1 4 – 63 25 – 63 32 F05/F07 20 17 17 100 13.5 7.0
SGC/SGCR 05.1 4 – 63 50 – 125 63 F05/F07 20 17 17 100 13.5 7.0
SGC/SGCR 07.1 4 – 63 100 – 250 125 F07 25.4 22 22 125 13.5 10
SGC/SGCR 10.1 5.6 – 90 200 – 500 250 F10 38 30 27 160 13.5 15
SGC/SGCR 12.1 20 – 275 400 – 1,000 500 F12 50 36 41 125 35 25
Notes on table
1) Unseating torque The “Torque by-pass” function (can be activated) allows increasing the pre-set torque to 130 %. This increase
only applies during actuator start for an adjustable time period, allowing safer unseating of blocked valves.
2) Running torque Maximum permissible torque for 15 min. running time.
3) Modulating torque Maximum permissible torque for modulating duty
4) Weight Indicated weight includes part-turn actuator with controls, electrical connection in standard version, unbored
coupling and handwheel
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Service conditions
Mounting position Any position
Installation altitude ≤ 2 000 m above seal level
> 2,000 m above sea level on request
Ambient temperature –25 °C to +70 °C
Humidity Up to 100 % relative humidity across the entire permissible temperature range
Enclosure protection according to IP68
EN 60529 According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: maximum 8 m head of water
Duration of continuous immersion in water: Max. 96 hours
Up to 10 operations during continuous immersion
Modulating duty is not possible during continuous immersion
Pollution degree according to IEC Pollution degree 4 (when closed), pollution degree 2 (internal)
60664-1
Vibration resistance according to 2 g, from 10 Hz to 200 Hz
IEC 60068-2-6 Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be
derived from this. Not valid in combination with gearboxes.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Further information
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions SGC 04.1– SGC 12.1/SGCR 04.1 – SGCR 12.1
Electrical data SGC 04.1– SGC 12.1/SGCR 04.1 – SGCR 12.1
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Operating time for 90° Torque range1) Running Valve attach- Valve shaft Handwheel Weight4)
in seconds torque2)/ ment
(adjustable in 9 steps) Modulating
torque3)
Max. Max. Standard Cylindrical Square Two-flat Ø Turns approx.
50 Hz/60 Hz [Nm] [Nm] EN ISO 5211 max. [mm] max. [mm] max. [mm] [mm] for 90° [kg]
SGC/SGCR 04.1 4 – 63 25 – 63 32 F05/F07 20 17 17 100 13.5 7.0
SGC/SGCR 05.1 4 – 63 50 – 125 63 F05/F07 20 17 17 100 13.5 7.0
SGC/SGCR 07.1 4 – 63 100 – 250 125 F07 25.4 22 22 125 13.5 10
SGC/SGCR 10.1 5.6 – 90 200 – 500 250 F10 38 30 27 160 13.5 15
SGC/SGCR 12.1 20 – 275 400 – 1,000 500 F12 50 36 41 125 35 25
Notes on table
1) Unseating torque The “Torque by-pass” function (can be activated) allows increasing the pre-set torque to 130 %. This increase
only applies during actuator start for an adjustable time period, allowing safer unseating of blocked valves.
2) Running torque Maximum permissible torque for 15 min. running time.
3) Modulating torque Maximum permissible torque for modulating duty
4) Weight Indicated weight includes part-turn actuator with controls, electrical connection in standard version, unbored
coupling and handwheel
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Device types Modbus slave, e.g. devices with digital and/or analogue inputs/outputs such as actuators, sensors
Number of devices 32 devices without repeater, with repeater expandable to 247
Fieldbus access Polling between master and slaves (query response).
Supported Modbus functions 01 Read Coil Status
(services)
02 Read Input Status
03 Read Holding Registers
04 Read Input Registers
05 Force Single Coil
15 (0FHex) Force Multiple Coils
06 Preset Single Register
16 (10Hex) Preset Multiple Registers
17 (11Hex) Report Slave ID
08 Diagnostics:
00 00 Loopback
00 10 (0AHex) Clear Counters and Diagnostic Register
00 11 (0BHex) Return Bus Message Count
00 12 (0CHex) Return Bus Communication Error Count
00 13 (0DHex) Return Bus Exception Error Count
00 14 (0EHex) Return Slave Message Count
00 15 (0FHex) Return Slave No Response Count
00 16 (10Hex) Return Slave NAK Count
00 17 (11Hex) Return Slave Busy Count
00 18 (12Hex) Return Character Overrun Count
Service conditions
Mounting position Any position
Installation altitude ≤ 2 000 m above seal level
> 2,000 m above sea level on request
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Further information
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions SGC 04.1– SGC 12.1/SGCR 04.1 – SGCR 12.1
Electrical data SGC 04.1– SGC 12.1/SGCR 04.1 – SGCR 12.1
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Output speed Torque Running Valve Valve shaft Stem Stem Handwheel Weight5)
rpm range1) torque2)/ attachment stroke diameter
Modulating
torque3)
for for
(adjustable in 9 Standard Cylindrical Square Two-flat rising valve rising valve Reduc-
steps) Max. Max. EN ISO max. max. max. stem4) stem4) Ø tion approx.
50 Hz/60 Hz [Nm] [Nm] 5211 [mm] [mm] [mm] max. [mm] max. [mm] [mm] ratio [kg]
SVC/SVCR
1.6 – 22 10 – 25 13 F05/F07 20 17 17 60 23 100 13 : 1 7.0
05.1
SVC/SVCR
1.6 – 22 20 – 50 25 F07 25.4 22 22 70 26 125 13 : 1 10
07.1
SVC/SVCR
0.6 – 8.0 40 – 100 50 F07 25.4 22 22 70 26 125 13 : 1 10
07.5
Notes on table
1) Unseating torque The “Torque by-pass” function (can be activated) allows increasing the pre-set torque to 130 %. This increase
only applies during actuator start for an adjustable time period, allowing safer unseating of blocked valves.
2) Running torque Maximum permissible torque for 15 min. running time.
3) Modulating torque Maximum permissible torque for modulating duty.
4) Rising valve stem For output drive type A
5) Weight Indicated weight includes globe valve actuator with controls, electrical connection in standard version,
unbored coupling and handwheel
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Service conditions
Mounting position Any position
Installation altitude ≤ 2 000 m über NN
> 2,000 m above sea level on request
Ambient temperature –25 °C to +70 °C
Humidity Up to 100 % relative humidity across the entire permissible temperature range
Enclosure protection according to IP68
EN 60529 According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: maximum 8 m head of water
Duration of continuous immersion in water: Max. 96 hours
Up to 10 operations during continuous immersion
Modulating duty is not possible during continuous immersion
Pollution degree according to IEC Pollution degree 4 (when closed), pollution degree 2 (internal)
60664-1
Vibration resistance according to 2 g, from 10 Hz to 200 Hz
IEC 60068-2-6 Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be
derived from this. Not valid in combination with gearboxes.
GL approval Environmental categories D, G, EMC2
Corrosion protection Standard: KS Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
Option: KX Suitable for use in areas with extremely high salinity, permanent condensation, and
high pollution.
Coating Double layer powder coating
Two-component iron-mica combination
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime Open-close 20,000 operating cycles OPEN - CLOSE - OPEN
duty: An operating cycle is based on an operation from CLOSED to OPEN and back to CLOSED
Modulating 5 million modulating steps
duty:
The lifetime depends on the load and the number of starts. A high starting frequency will rarely improve the
modulating accuracy. To reach the longest possible maintenance and fault-free operating time, the number of
starts per hour chosen should be as low as permissible for the process.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Further information
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions SVC 05.1– SVC 07.5/SVCR 05.1 – SVCR 07.5
Electrical data SVC 05.1– SVC 07.5/SVCR 05.1 – SVCR 07.5
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Output speed Torque Running Valve Valve shaft Stem Stem Handwheel Weight5)
rpm range1) torque2)/ attachment stroke diameter
Modulating
torque3)
for for
(adjustable in 9 Standard Cylindrical Square Two-flat rising valve rising valve Reduc-
steps) Max. Max. EN ISO max. max. max. stem4) stem4) Ø tion approx.
50 Hz/60 Hz [Nm] [Nm] 5211 [mm] [mm] [mm] max. [mm] max. [mm] [mm] ratio [kg]
SVC/SVCR
1.6 – 22 10 – 25 13 F05/F07 20 17 17 60 23 100 13 : 1 7.0
05.1
SVC/SVCR
1.6 – 22 20 – 50 25 F07 25,4 22 22 70 26 125 13 : 1 10
07.1
SVC/SVCR
0.6 – 8.0 40 – 100 50 F07 25,4 22 22 70 26 125 13 : 1 10
07.5
Notes on table
1) Unseating torque The “Torque by-pass” function (can be activated) allows increasing the pre-set torque to 130 %. This increase
only applies during actuator start for an adjustable time period, allowing safer unseating of blocked valves.
2) Running torque Maximum permissible torque for 15 min. running time.
3) Modulating torque Maximum permissible torque for modulating duty
4) Rising valve stem For output drive type A
5) Weight Indicated weight includes globe valve actuator with controls, electrical connection in standard version,
unbored coupling and handwheel
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Service conditions
Mounting position Any position
Installation altitude ≤ 2 000 m über NN
> 2,000 m above sea level on request
Ambient temperature –25 °C to +70 °C
Humidity Up to 100 % relative humidity across the entire permissible temperature range
Enclosure protection according to IP68
EN 60529 According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: maximum 8 m head of water
Duration of continuous immersion in water: Max. 96 hours
Up to 10 operations during continuous immersion
Modulating duty is not possible during continuous immersion
Pollution degree according to IEC Pollution degree 4 (when closed), pollution degree 2 (internal)
60664-1
Vibration resistance according to 2 g, from 10 Hz to 200 Hz
IEC 60068-2-6 Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be
derived from this. Not valid in combination with gearboxes.
GL approval (option) Environmental categories D, G, EMC2
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Corrosion protection Standard: KS Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
Option: KX Suitable for use in areas with extremely high salinity, permanent condensation, and
high pollution.
Coating Double layer powder coating
Two-component iron-mica combination
Colour Standard: AUMA silver-grey (similar to RAL 7037)
Option: Available colours on request
Lifetime Open-close 20,000 operating cycles OPEN - CLOSE - OPEN
duty: An operating cycle is based on an operation from CLOSED to OPEN and back to CLOSED
Modulating 5 million modulating steps
duty:
The lifetime depends on the load and the number of starts. A high starting frequency will rarely improve the
modulating accuracy. To reach the longest possible maintenance and fault-free operating time, the number of
starts per hour chosen should be as low as permissible for the process.
Further information
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions SVC 05.1– SVC 07.5/SVCR 05.1 – SVCR 07.5
Electrical data SVC 05.1– SVC 07.5/SVCR 05.1 – SVCR 07.5
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Type Output speed Torque Running Valve Valve shaft Stem Stem Handwheel Weight5)
rpm1) range torque2)/ attachment stroke diameter
Modulating
torque3)
for for
(adjustable in 9 Standard Cylindrical Square Two-flat rising valve rising valve Reduc-
steps) Max. Max. EN ISO max. max. max. stem4) stem4) Ø tion approx.
50 Hz/60 Hz [Nm] [Nm] 5211 [mm] [mm] [mm] max. [mm] max. [mm] [mm] ratio [kg]
SVC/SVCR
1.6 – 22 10 – 25 13 F05/F07 20 17 17 60 23 100 13 : 1 7.0
05.1
SVC/SVCR
1.6 – 22 20 – 50 25 F07 25.4 22 22 70 26 125 13 : 1 10
07.1
SVC/SVCR
0.6 – 8.0 40 – 100 50 F07 25.4 22 22 70 26 125 13 : 1 10
07.5
Notes on table
1) Unseating torque The “Torque by-pass” function (can be activated) allows increasing the pre-set torque to 130 %. This increase
only applies during actuator start for an adjustable time period, allowing safer unseating of blocked valves.
2) Running torque Maximum permissible torque for 15 min. running time.
3) Modulating torque Maximum permissible torque for modulating duty.
4) Rising valve stem For output drive type A
5) Weight Indicated weight includes globe valve actuator with controls, electrical connection in standard version,
unbored coupling and handwheel
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Device types Modbus slave, e.g. devices with digital and/or analogue inputs/outputs such as actuators, sensors
Number of devices 32 devices without repeater, with repeater expandable to 247
Fieldbus access Polling between master and slaves (query response).
Supported Modbus functions 01 Read Coil Status
(services)
02 Read Input Status
03 Read Holding Registers
04 Read Input Registers
05 Force Single Coil
15 (0FHex) Force Multiple Coils
06 Preset Single Register
16 (10Hex) Preset Multiple Registers
17 (11Hex) Report Slave ID
08 Diagnostics:
00 00 Loopback
00 10 (0AHex) Clear Counters and Diagnostic Register
00 11 (0BHex) Return Bus Message Count
00 12 (0CHex) Return Bus Communication Error Count
00 13 (0DHex) Return Bus Exception Error Count
00 14 (0EHex) Return Slave Message Count
00 15 (0FHex) Return Slave No Response Count
00 16 (10Hex) Return Slave NAK Count
00 17 (11Hex) Return Slave Busy Count
00 18 (12Hex) Return Character Overrun Count
Service conditions
Mounting position Any position
Installation altitude ≤ 2 000 m above seal level
> 2,000 m above sea level on request
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Further information
EU Directives Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
Reference documents Dimensions SVC 05.1– SVC 07.5/SVCR 05.1 – SVCR 07.5
Electrical data SVC 05.1– SVC 07.5/SVCR 05.1 – SVCR 07.5
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Connectors
2. Technical Data
Miscellaneous
Connectors SGC/SGCR, SVC/SVCR Parallel interface 44
Connectors SGC/SGCR, SVC/SVCR Profibus DP, Modbus RTU 45
Corrosion protection
Types of corrosion protection 46
Corrosion protection KS in acc. to painting spec. P1.001 47
Corrosion protection KS in acc. to painting spec. P1.002 48
Corrosion protection KX in acc. to painting spec. P1.002 50
Painting specifications
Painting specification P1.001 52
Painting specification P1.002 53
Lubricants
Grease and oil quantities 54
Ambient temperatures/lubricant in the gear housing 57
SGC/SGCR, SVC/SVCR
Parallel interface
Technical data Connector
General information
Mating plugs used as connecting plug for the customer are called plug and socket assemblies. The plug and socket assembly is the interface to the
actuator.
Cable diameter Power plug (power sup- 2 – 14.5 mm
ply):
Signal connector 2 – 10.5 mm
(parallel interface):
AUMA article numbers Plug and socket assembly for power supply and parallel interface: Z100.935A
including:
6-pin K007.818A Power connector (1x) in KS (KX on request)
K007.814 Crimp contact (6x) [RC-5CS2000]
19-pin K007.819 Signal connector (1x) in KS (KX on request)
K007.816 Crimp contact (16x) [RC-67S2000]
K007.877 Crimp contact (2x) [RC-6ES2000]
K007.817 Crimp contact (1x) [RC-6FS2000]
Crimping pliers (for signal and power Phoenix designation: 4-arbor crimping pliers with digital display for turned contacts: RC-Z2514
connectors) AUMA article number: K008.074
Phoenix designation: 4-arbor crimping pliers for turned contacts: RC-Z2504
AUMA article number: K008.106
Crimping pliers settings
AUMA Phoenix designation Cross section Crimp arbor setting Locator
(RC-Z2514/RC-Z2504)
article number crimp contact [mm²] [mm]
(for signal and power connectors)
1.00 0.97
K007.814 RC-5CS2000 5
1.50 1.02
0.75 0.85
K007.816 RC-67S2000 7
1.00 0.88
0.75 0.85
K007.877 RC-6ES2000 9
1.00 0.88
0.75 0.85
K007.817 RC-6FS2000 9
1.00 0.88
Insertion and ejection tool Phoenix designation: Insertion and ejection tool for RC crimp contacts Ø 1 mm: RC-Z2494
(for signal and power connectors) AUMA article number: K008.107
Phoenix designation: Insertion and ejection tool for RC crimp contacts Ø 1.5 mm: RC-Z2274
AUMA article number: K008.108
Ready-made mating connectors
Phoenix designation Power connectors Signal connectors
with cables
cable length as desired in xxx cable length as desired in xxx
metres metres
Straight KC-03018EKC1xxx KC-01618EBK1xxx
90° angled KC-0301TEKC1xxx KC-0161TEBK1Axxx
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
General information
Mating plugs used as connecting plug for the customer are called plug and socket assemblies. The plug and socket assembly is the interface to the
actuator.
Cable diameter Power plug (power supply): 2 – 14.5 mm
Signalstecker (Businter- 6 – 8.5 mm
face):
AUMA article numbers Connection set power supply and bus interface: Z107.125
consisting of:
6-pin K007.818 Power connector (1x) in KS (KX on request)
K007.814 Crimp contact (6x) [RC-5CS2000]
5-pin K007.885 Signal connector complete (1x) in KS (KX on request)
K007.884 Female contact complete (1x) in KS (KX on request)
Crimping pliers (for power connectors) Phoenix designation: 4-arbor crimping pliers with digital display for turned contacts: RC-Z2514
AUMA article number: K008.074
Phoenix designation: 4-arbor crimping pliers for turned contacts: RC-Z2504
AUMA article number: K008.106
Crimping pliers settings
AUMA Phoenix designation Cross section Crimp arbor setting Locator
(RC-Z2514/RC-Z2504)
article number crimp contact [mm²] [mm]
(for power connectors)
1.00 0.97
K007.814 RC-5CS2000 5
1.50 1.02
Insertion and ejection tool Phoenix designation: Insertion and ejection tool for RC crimp contacts Ø 1.5 mm: RC-Z2274
(for power connectors) AUMA article number: K008.108
Ready-made mating connectors
Phoenix designation Power connectors Signal connector (bus interface)
with cables
cable length as desired in xxx Cable length 15 metres with male and
metres female connectors at each end, respectively
made of plastic material
Straight KC-03018EKC1xxx K008.217
90° angled KC-0301TEKC1xxx K008.260
T or Y connector for bus interface Alternatively for bus interface: 1 connector (type T or Y) instead of to separate connectors (IN and OUT)
Used as additional intermediate component to maintain bus communication in case AUMA actuator is
switched off or disconnected from bus.
AUMA article numbers:
T connector: K008.456 (large)
K005.816 (small)
Y connector: K006.135
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
This overview accounts for atmospheric ambient conditions, but not for special chemical atmospheres, requiring absence
of aluminium or nonferrous heavy metal, for example.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
This description applies to AUMA products with powder coating in accordance with painting specification P1.001.
Corrosion protection KS based on painting specification P1.001 is suitable for use in areas with high salinity, almost permanent conden-
sation, and high pollution. Corrosion protection includes the use of suitable material for outer parts and structure of the painting.
1. Materials
1.1 Outside fasteners (e.g. screws) are made of stainless steel with additional metallic surface protection.
2. Surface treatment
2.1 After machining, steel parts are covered with metallic surface protection (except SQ/GS coupling and internal GS coupling
compartment)
2.2 Aluminium parts such as the handwheel are electrophoretically coated.
3. General information
3.1 Housing parts made of GJL/GJS are blasted: Sa 2 ½ in accordance with EN ISO 12944-4.
3.2 Aluminium housing parts are not blasted.
4. Painting system
4.1 During preliminary treatment, housing parts are chemically cleaned and painted with an Oxsilan® conversion coating.
4.2 Housing parts are primer coated with:
Product: FREOPOX PE 1204A
Manufacturer: Emil Frei GmbH & Co. KG
Structure: Thermally hardening powder coating based on epoxy resin.
Colour: RAL 7035
Film thickness: 70 µm
6. Notes
6.1 The top coat can be painted with all common 1- or 2-component coating materials (i.e. artificial resin, epoxy resin, PVC, polyu-
rethane, polyamide and acrylic enamels).
We recommend verifying the compatibility of the paints before applying a new wet painting layer.
For this, the surfaces to be painted must be slightly ground and carefully cleaned, i. e. free of foreign substance, grease, oily
dirt and dust.
6.2 Mounting surface to the valve is powder coated.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
This description applies to AUMA products with powder coating in accordance with painting specification P1.002.
Corrosion protection KS based on painting specification P1.002 is suitable for use in areas with high salinity, almost permanent conden-
sation, and high pollution. Corrosion protection includes the use of suitable material for outer parts and structure of the painting.
1. Materials
1.1 Outside fasteners (e.g. screws) are made of stainless steel with additional metallic surface protection.
1.2 Name plates are made of aluminium.
2. Surface treatment
2.1 After machining, steel parts are covered with metallic surface protection (except SQ/GS coupling and internal GS coupling
compartment)
2.2 Aluminium parts such as the handwheel are electrophoretically coated.
3. General information
3.1 Housing parts made of GJL/GJS are blasted: Sa 2 ½ in accordance with EN ISO 12944-4.
3.2 Aluminium housing parts are not blasted.
4. Painting system
4.1 During preliminary treatment, housing parts are chemically cleaned and painted with an Oxsilan® conversion coating.
4.2 Housing parts are primer coated with:
Product: FREOPOX PE 1204A
Manufacturer: Emil Frei GmbH & Co. KG
Structure: Thermally hardening powder coating based on epoxy resin.
Colour: RAL 7035
Film thickness: 70 µm
4.3 Housing parts are finish coated with:
Product: FREIOTHERM PU 4003M
Manufacturer: Emil Frei GmbH & Co. KG
Structure: Thermally hardening powder coating based on polyurethane.
Colour: A0001, AUMA silver-grey (similar to RAL 7037 dust grey)
Film thickness: 70 µm
4.4.2 Housing parts are coated with finish painting for special colours:
Product: SikaCor EG 5
Manufacturer: Sika Deutschland GmbH
Structure: 2-component finish painting based on polyurethane
Colour: Special colour according to work order
Film thickness: 60 µm (dry)
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
6. Notes
6.1 The top coat can be painted with all common 1- or 2-component coating materials (i.e. artificial resin, epoxy resin, PVC, polyu-
rethane, polyamide and acrylic enamels).
Subsequent finishing with chlorine rubber paints subject to restrictions.
We recommend verifying the compatibility of the paints before applying a new wet painting layer. For this, the surfaces to be
painted must be slightly ground and carefully cleaned, i. e. free of foreign substance, grease, oily dirt and dust.
6.2 Mounting surface to the valve is powder coated.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
This description applies to AUMA products with powder coating in accordance with painting specification P1.002.
Corrosion protection KX based on painting specification P1.002 is suitable for use in areas with high salinity, almost permanent con-
densation, and high pollution. Corrosion protection includes the use of suitable material for outer parts and structure of the painting.
1. Materials
1.1 Outside fasteners (e.g. screws) are made of stainless steel with additional metallic surface protection.
1.2 Name plates are made of aluminium.
2. Surface treatment
2.1 After machining, steel parts are covered with metallic surface protection (except SQ/GS coupling and internal GS coupling
compartment)
2.2 Aluminium parts such as the handwheel are electrophoretically coated.
3. General information
3.1 Housing parts made of GJL/GJS are blasted: Sa 2 ½ in accordance with EN ISO 12944-4.
3.2 Aluminium housing parts are not blasted.
4. Painting system
4.1 During preliminary treatment, housing parts are chemically cleaned and painted with an Oxsilan® conversion coating.
4.2 Housing parts are primer coated with:
Product: FREOPOX PE 1204A
Manufacturer: Emil Frei GmbH & Co. KG
Structure: Thermally hardening powder coating based on epoxy resin.
Colour: RAL 7035
Film thickness: 70 µm
4.3 Housing parts are finish coated with:
Product: FREIOTHERM PU 4003M
Manufacturer: Emil Frei GmbH & Co. KG
Structure: Thermally hardening powder coating based on polyurethane.
Colour: A0001, AUMA silver-grey (similar to RAL 7037 dust grey)
Film thickness: 70 µm
4.4.2 Housing parts are coated with finish painting for special colours:
Product: SikaCor EG 5
Manufacturer: Sika Deutschland GmbH
Structure: 2-component finish painting based on polyurethane
Colour: Special colour according to work order
Film thickness: 60 µm (dry)
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
6. Notes
6.1 The top coat can be painted with all common 1- or 2-component coating materials (i.e. artificial resin, epoxy resin, PVC, polyu-
rethane, polyamide and acrylic enamels).
Subsequent finishing with chlorine rubber paints subject to restrictions.
We recommend verifying the compatibility of the paints before applying a new wet painting layer. For this, the surfaces to be
painted must be slightly ground and carefully cleaned, i. e. free of foreign substance, grease, oily dirt and dust.
6.2 Mounting surface to the valve is powder coated.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
1. General information
1.1 Housing parts made of GJL/GJS are blasted: Sa 2 ½ in accordance with EN ISO 12944-4.
1.2 Aluminium housing parts are not blasted.
2. Painting system
2.1 During preliminary treatment, housing parts are chemically cleaned and painted with an Oxsilan® conversion coating.
2.2 Housing parts are primer coated with:
Product: FREOPOX PE 1204A
Manufacturer: Emil Frei GmbH & Co. KG
Structure: Thermally hardening powder coating based on epoxy resin.
Colour: RAL 7035
Film thickness: 70 µm
4. Notes
4.1 The top coat can be painted with all common 1- or 2-component coating materials (i.e. artificial resin, epoxy resin, PVC, polyu-
rethane, polyamide and acrylic enamels).
We recommend verifying the compatibility of the paints before applying a new wet painting layer.
For this, the surfaces to be painted must be slightly ground and carefully cleaned, i. e. free of foreign substance, grease, oily
dirt and dust.
4.2 Mounting surface to the valve is powder coated.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Technical description Powder coating, primer coating, finish coating and wet painting layer
1. General information
1.1 Housing parts made of GJL/GJS are blasted: Sa 2 ½ in accordance with EN ISO 12944-4.
1.2 Aluminium housing parts are not blasted.
2. Painting system
2.1 During preliminary treatment, housing parts are chemically cleaned and painted with an Oxsilan® conversion coating.
2.2 Housing parts are primer coated with:
Product: FREOPOX PE 1204A
Manufacturer: Emil Frei GmbH & Co. KG
Structure: Thermally hardening powder coating based on epoxy resin.
Colour: RAL 7035
Film thickness: 70 µm
2.4.2 Housing parts are coated with finish painting for special colours:
Product: SikaCor EG 5
Manufacturer: Sika Deutschland GmbH
Structure: 2-component finish painting based on polyurethane
Colour: Special colour according to work order
Film thickness: 60 µm (dry)
4. Notes
4.1 The top coat can be painted with all common 1- or 2-component coating materials (i.e. artificial resin, epoxy resin, PVC, polyu-
rethane, polyamide and acrylic enamels). Subsequent finishing with chlorine rubber paints subject to restrictions.
We recommend verifying the compatibility of the paints before applying a new wet painting layer.
For this, the surfaces to be painted must be slightly ground and carefully cleaned, i. e. free of foreign substance, grease, oily
dirt and dust.
4.2 Mounting surface to the valve is powder coated.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Multi-turn actuators
SA 07.1/07.5 10.0/10.1 14.1/14.5 16.1 25.1 30.1 35.1 40.1 48.1
3 0.62 -0.03 0.93 -0.04 2.3 -0.1 4.5 ±0.1 11.0 ±0.2 16.0 ±0.2 29.0 +0.4 36.0 +0.4 56.0 +0.5
Qty dm
Weight kg2) 0.56 -0.03 0.84 -0.04 2.1 -0.1 4.1 ±0.1 9.9 ±0.2 14.4 ±0.2 26.1 +0.4 32.4 +0.4 50.4 +0.5
SA 07.2/07.6 10.2 14.2/14.6 16.2
F07 F10/G0
Qty dm3 0.58 ±0.02 0.525 ±0.02 0.9 ±0.02 1.76 ±0.05 3.1 ±0.05
Weight kg2) 0.52 ±0.02 0,47 ±0,02 0.81 ±0.02 1.58 ±0.05 2.8 ±0.05
Part-turn actuators
SQ 05.2 07.2 10.2 12.2 14.2
3 0.7 ±0.02 0.7 ±0.02 1.3 ±0.02 1.7 ±0.02 1.8 ±0.05
Qty dm
Weight kg2) 0.63 ±0.02 0.63 ±0.02 1.17 ±0.02 1.53 ±0.02 1.62 ±0.05
SG 05 07 10 12
3 0.3 0.3 0.52 0.8
Qty dm
Weight kg2) 0.27 0.27 0.47 0.72
SG 05.1 07.1 10.1 12.1
3 0.3 0.3 0.52 0.8
Qty dm
Weight kg2) 0.27 0.27 0.47 0.72
SG 04.2 05.2 07.2 10.2
3 0.09 0.14 0.30 0.52
Qty dm
Weight kg3) 0.07 0.12 0.25 0.43
SG 03.3 04.3 05.3
Qty dm3 0.14 0.14 0.23
Weight kg3) 0.12 0.12 0.19
SGM/SGC 04.1 05.1 07.1 10.1
3 0.11 0.11 0.24 0.40
Qty dm
Weight kg3) 0.09 0.09 0.20 0.33
Worm gearboxes
GS 50.3 63.3 80.3 100.3 100.3 100.3 100.3 125.3 125.3 125.3
(52:1) (126:1) (160:1) (208:1) (52:1) (126:1) (160:1)
Qty dm3 0.1 0.3 0.4 1 1.35 1.35 1.35 1.3 1.65 1.65
2) 0.09 0.27 0.36 0.9 1.22 1.22 1.22 1.17 1.49 1.49
Weight kg
GS 125.3 160.3 160.3 160.3 160.3 200.3 200.3 200.3 200.3 200.3
(208:1) (54:1) (218:1) (442:1) (880:1) (53:1) (67:1) (214:1) (434:1) (864:1)
Qty dm3 1.65 3.3 4.3 4.3 4.3 6.6 6.6 8.1 8.1 8.6
2) 1.49 3 3.9 3.9 3.9 6 6 7.4 7.4 7.8
Weight kg
GS 200.3 250.3 250.3 250.3 250.3 250.3
(1 752:1) (52:1) (210:1) (411:1) (848:1) (1 718:1)
Qty dm3 8.6 12.2 14.4 14.4 14.7 14.7
2) 7.8 11 13 13 13.3 13.3
Weight kg
GS 315 400 500 630.3
Qty dm3 27.5 55.0 110.0 216.7
2) 25.0 50.0 100.0 195.0
Weight kg
Spur gearboxes
GST 10.1 14.1/14.5 16.1 25.1 30.1 35.1 40.1
3 0.7 1.5 3.0 8.0 12.0 20.0 27.0
Qty dm
Weight kg2) 0.62 1.3 2.7 7.1 10.7 17.8 24.0
Bevel gearboxes
GK 10.2 14.2/14.6 16.2 25.2 30.2 35.2 40.2
3 0.25 0.6 1.0 4.0 14.0 20.0 22.0
Qty dm
Weight kg2) 0.22 0.53 0.9 3.6 12.5 17.8 19.6
Multi-turn gearboxes
GHT 320.3 500.3 800.3 1200.3
3 30.0 71.5 93.5 146.5
Qty dm
2) 27 64.4 84.2 131.9
Weight kg
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Temperature range
Type Extreme low temper-
Normal (standard) Low temperature ature High temperature
List designation N L EL-60 H
Actuator Grease/
Version °C oil °C Grease °C Grease °C Grease
SA 07.2 – 16.2 Standard –40/+80 F15 – – –60/+60 F2 0/+120 F3
SA 25.1 – 48.1 Standard –40/+80 F15 – – –60/+60 F2 0/+120 F3
1)
SA 07.2 – 16.2 With oil –25/+80 O9 – – – – – –
SAR 07.2 – 16.2 Standard –40/+70 F15 – – –60/+60 F2 0/+100 F3
SAR 25.1 – 30.1 Standard –40/+70 F15 – – –60/+60 F2 0/+100 F3
SAR 07.2 – 16.2 With oil1) –25/+70 O9 – – – – – –
SAEx 07.2 Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
4 – 32 rpm Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAEx 07.6
45 – 180 rpm Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
4 – 11 rpm Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAEx 10.2
16 – 180 rpm Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
4 – 11 rpm Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAEx 14.2
16 – 180 rpm Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAEx 14.6 Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAEx 16.2 Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAEx 25.1 – 48.1 Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAEx 07.2 – 16.2 With oil1) –25/+70 O9 – – – – – –
4 – 45 rpm Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAREx 07.2
63 – 90 rpm Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
4 – 45 rpm Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAREx 07.6
63 – 90 rpm Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
4 – 32 rpm Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAREx 10.2
45 – 90 rpm Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
4 – 11 rpm Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAREx 14.2
16 – 90 rpm Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAREx 14.6 Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAREx 16.2 Ex –30/+40 (+60/+80) F11 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAREx 25.1 – 30.1 Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SAREx 07.2 – 16.2 With oil1) –25/+70 O9 – – – – – –
Nuclear power
SAN 07.1 – 35.1 –25/+80 F11 – – – – – –
plants
Nuclear power
SARN 07.1 – SARN 35.1 –25/+80 F11 – – – – – –
plants
Nuclear power
SAI 6 – 100 –20/+80 F11 – – – – – –
plants
Nuclear power
SAI 07.2 – 16.2 –30/+80 F11 – – – – – –
plants
Nuclear power
SARI 07.2 – 16.2 –30/+60 F11 – – – – – –
plants
Nuclear power
SAN 07.2 – 16.2 –30/+80 F11 – – – – – –
plants
Nuclear power
SARN 07.2 – SARN 16.2 –30/+60 F11 – – – – – –
plants
SQ 05.2 – 14.2 Standard –40/+80 F15 – – –60/+60 F2 0/+120 F3
SQR 05.2 – 14.2 Standard –40/+70 F15 – – –60/+60 F2 0/+100 F3
SQEx 05.2 – SQEx 14.2 Ex –30/+60 (+80) F15 –40/+60 F2 –60/+60 F2 – –
SQREx 05.2 – 14.2 Ex –30/+40 (+60/+80) F15 –40/+40 (+60) F2 –60/+40 (+60) F2 – –
SGC 04.1 – 12.1 Marine –25/+70 O2 – – – – – –
SGCR 04.1 – 12.1 Marine –25/+70 O2 – – – – – –
SGM 04.1 – 12.1 Marine –25/+70 O2 – – – – – –
SGMR 04.1 – 12.1 Marine –25/+70 O2 – – – – – –
Temperature range
Type Extreme low temper-
Normal (standard) Low temperature ature High temperature
List designation N L EL-60 H
Actuator Grease/
Version °C oil °C Grease °C Grease °C Grease
SVC 05.1 – 07.5 Marine –25/+70 O2 – – – – – –
SVCR 04.1 – 12.1 Marine –25/+70 O2 – – – – – –
SVM 05.1 – 07.5 Marine –25/+70 O2 – – – – – –
SVMR 04.1 – 12.1 Marine –25/+70 O2 – – – – – –
Lubricants:
F2 = Fuchs Discor R EP 000
F3 = Zepf AR 12 K
F11 = Fuchs Renolit LST
F15 = Shell Alvania 1029
O2 = Fuchs Unisyn SC 32
O9 = Oest SAE 75W-90
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Basic Range 60
3-phase AC current
SBA 06 – SBA 200 380 V/50 Hz 60
400 V/50 Hz 61
400 V/60 Hz 62
1-phase AC current
SBA 06 – SBA 200 110 V/60 Hz 66
3. Electrical data
115 V/50 Hz 67
Actuators
220 V/60 Hz 68
230 V/50 Hz 69
Direct current
ED 25 – ED 50, EQ 40 – EQ 600 24 V DC 82
SBA 06 – SBA 200 24 V DC 83
Smart Range 84
1-phase AC current
SD 05 – SD 25 100 V – 240 V/50 Hz/60 Hz 84
SDL 50 – SDL 100 100 V – 240 V/50 Hz/60 Hz 85
SGC 04.1 – SGC 12.1/SGCR 04.1 – SGCR 12.1 115 V, 230 V/50 Hz/60 Hz 86
SVC 05.1 – SVC 07.5/SVCR 05.1 – SVCR 07.5 115 V, 230 V/50 Hz/60 Hz 87
Direct current
SD 05 – SD 25 24 V DC 88
SDL 50 – SDL 100 24 V DC 89
SBA 06 – SBA 200
Electrical data Linear actuators with 3-phase AC motors
380 V/50 Hz
Notes on table
1) Max operating force Also corresponds to maximum operating force in modulating duty.
2) Power P Output of mechanical power at motor shaft at maximum operating force of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
3) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
4) Max. current Imax Current at maximum operating force. Also corresponds to maximum force in modulating duty. We recom-
mend sizing the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Max operating force Also corresponds to maximum operating force in modulating duty.
2) Power P Output of mechanical power at motor shaft at maximum operating force of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
3) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
4) Max. current Imax Current at maximum operating force. Also corresponds to maximum force in modulating duty. We recom-
mend sizing the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Max operating force Also corresponds to maximum operating force in modulating duty.
2) Power P Output of mechanical power at motor shaft at maximum operating force of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
3) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
4) Max. current Imax Current at maximum operating force. Also corresponds to maximum force in modulating duty. We recom-
mend sizing the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
5) Option: S1 - 100 %
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
5) Option: S1 - 100 %
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
5) Option: S1 - 100 %
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Max operating force. Also corresponds to maximum operating force in modulating duty.
2) Power P Output of mechanical power at motor shaft at maximum operating force of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
3) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
4) Max. current Imax Current at maximum operating force. Also corresponds to maximum force in modulating duty. We recom-
mend sizing the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Max operating force. Also corresponds to maximum operating force in modulating duty.
2) Power P Output of mechanical power at motor shaft at maximum operating force of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
3) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
4) Max. current Imax Current at maximum operating force. Also corresponds to maximum force in modulating duty. We recom-
mend sizing the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Max operating force Also corresponds to maximum operating force in modulating duty.
2) Power P Output of mechanical power at motor shaft at maximum operating force of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
3) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
4) Max. current Imax Current at maximum operating force. Also corresponds to maximum force in modulating duty. We recom-
mend sizing the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Max operating force Also corresponds to maximum operating force in modulating duty.
2) Power P Output of mechanical power at motor shaft at maximum operating force of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
3) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
4) Max. current Imax Current at maximum operating force. Also corresponds to maximum force in modulating duty. We recom-
mend sizing the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Output of mechanical power at motor shaft at maximum torque of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Output of mechanical power at motor shaft at maximum torque of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Output of mechanical power at motor shaft at maximum torque of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Output of mechanical power at motor shaft at maximum torque of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Output of mechanical power at motor shaft at maximum torque of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Output of mechanical power at motor shaft at maximum torque of linear actuator.
The consumed electrical power can be calculated using the following formula:
P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
5) Option: S1 - 100 %
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
5) Option: S1 - 100 %
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
5) Option: S1 - 100 %
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
The consumed electrical power can be calculated using the following formula: P = U x I x cos
2) Nominal current IN Rated current at maximum modulating torque and indicated operating time
3) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
4) Type of duty All actuators are also suitable for type of duty S2 - 15 min
5) Option: S1 - 100 %
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Operating time Operating times may vary depending on the load.
2 Power P Output of mechanical power at motor shaft at maximum torque of part-turn actuator.
3) Output speed Motor speed at max. torque
4) Nominal current IN Rated current at maximum modulating torque and indicated operating time.
5) Max. current Imax Current at maximum torque. We recommend selecting the switchgear in compliance with these values.
6) Type of duty All actuators are also suitable for type of duty S2 - 15 min
Number of starts: 600 cycles per hour
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Max operating force Also corresponds to maximum operating force in modulating duty.
2 Power P Output of mechanical power at motor shaft at maximum operating force of linear actuator.
3) Max. current Imax Current at maximum operating force. Also corresponds to maximum force in modulating duty. We recommend
sizing the switchgear in compliance with these values.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Maximum power consumption
2) Nominal current IN Current at running torque
3) Starting current Imax Maximum short-term starting current
4) Step motor
5) Brushless DC motor
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Maximum power consumption
2) Nominal current IN Current at running torque
3) Starting current Imax Maximum short-term starting current
4) Step motor
5) Brushless DC motor
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Torque Adjustable tripping torque
2) Running torque Permissible average torque in open-close duty S2 - 15 min
3) Modulating torque Torque in modulating duty S4 - 40 %
4) Rated current Rated current at maximum modulating torque and shortest operating time
5) Max. current Current at maximum torque and maximum speed. We recommend selecting the switchgears in compliance
with these values.
Motor data is approximate. Due to usual manufacturing tolerances, there may be deviations from the values given. The permissible variation of the
nominal voltage is ±10 %. Higher voltage failures cause reduction in nominal output torque.
The output data of the fuses to be provided on site must not exceed the following values:
15 A/250 V at a maximum mains current of 5,000 A AC.
For protection with circuit breakers, devices with 6 A at 230 V AC, or 13 A at 115 V AC with characteristics D according to VDE 0641 and IEC 60898
with at least 15 kA switching power are recommended.
Groups of up to four actuators can be protected via one circuit breaker with at least 15 kA switching power, 20 A at 230 V AC, or 40 A at 115 V AC,
characteristics D according to IEC 60898.
For further information, refer to "Technical data Part-turn actuators SGC/SGCR 04.1 – SGC/SGCR 12.1 with integral actuator controls".
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1) Torque Adjustable tripping torque
2) Running torque Permissible average torque in open-close duty S2 - 15 min
3) Modulating torque Torque in modulating duty S4 - 40 %
4) Rated current Rated current at maximum modulating torque and shortest operating time
5) Max. current Current at maximum torque and maximum speed. We recommend selecting the switchgears in compliance
with these values.
Motor data is approximate. Due to usual manufacturing tolerances, there may be deviations from the values given. The permissible variation of the
nominal voltage is ±10 %. Higher voltage failures cause reduction in nominal output torque.
The output data of the fuses to be provided on site must not exceed the following values:
15 A/250 V at a maximum mains current of 5,000 A AC.
For protection with circuit breakers, devices with 6 A at 230 V AC, or 13 A at 115 V AC with characteristics D according to VDE 0641 and IEC 60898
with at least 15 kA switching power are recommended.
Groups of up to four actuators can be protected via one circuit breaker with at least 15 kA switching power, 20 A at 230 V AC, or 40 A at 115 V AC,
characteristics D according to IEC 60898.
For further information, refer to "Technical data Globe valve actuators SVC/SVCR 05.1 – SVC/SVCR 07.5 with integral actuator controls".
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Maximum power consumption
2) Nominal current IN Current at running torque
3) Starting current Imax Maximum short-term starting current
4) Step motor
5) Brushless DC motor
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Notes on table
1 Power P Maximum power consumption
2) Nominal current IN Current at running torque
3) Starting current Imax Maximum short-term starting current
4) Step motor
5) Brushless DC motor
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Basic Range
SBA 06-1/-2/-3/-4 92
SBA 12 –SBA 200 93
NR 2.1 – NR 2.3 94
ED 25 – ED 50 95
EQ 40 – EQ 150 97
EQ 300 – EQ 600 99
EQ 40 – EQ 600 with base and lever 101
Smart Range
SD 05 – SD 25 102
SDL 50 – SDL 100 104
4. Dimensions
Actuators
SBA 06-1/-2/-3/-4
S 2)
Ø d3
Ø d4
h1
H2
H1
h
P
H
L
L4
Ø d9
Ø d5 2)
Ø d8
h2
Ø d2
d1
ØB
h1
F1
H2
F
H1
G1
ØD
G
P
h2
h
H
Ø d9
Option:
L4
2)
L
F2
X
C1 C
View X
G2
ØB
Ø d4 x h3
Ø d3
Ø d5 2)
Ø D1
Ø d6 2)
Ø d3
Ø d4 x h3
h1
H2
H1
P
h2
h
H
2)
Ø d5
L4
Ø d8 Ø d9
Ø d2 L
Ø d1
h1
1)
H1
H2
H3
L max. 2)
P A
d4 x h2
A1 C2
A2 Ø d3
F07
F05
C1
F04
F03
C
Ø d7 H8 from 8 10 12
to 10 12 15
b JS9 1) 3 4 5
t 1) 1.4 +0.1 1.8 +0.1 2.3 +0.1
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
h1
h3
N
Option:
KS1 compact connector
1)
H1
H
P
G
H2
ØD
H4
F
H3
Lower edge of actuator
L max.2)
A3 d4 x h2
N1
Option: A Ø d3
A1
Profibus DP PBD100
A2
F10
G1
C4
F07
C3
F05
C2
M
F04
C1
C
F1
Lower edge of actuator
N2
Option:
Local controls VSE
Ø D1
G2
F2
N3
Option:
Emergency operation module FSC20/
transformer housing PEL-DS
G3
F3
Ø d7 H8 from 10 12 17
to 12 17 20
b JS9 1) 4 5 6
t 1.8 +0.1 2.3 +0.1 2.8 +0.1
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
h1
h3
N
Option:
KS1 compact connector
1)
H1
H
P
G
H2
ØD
H4
F
Lower edge of actuator
H5
L max.2)
N1
Option:
H6
Profibus DP PBD100
A
d4 x h2
Ø d3
G1
A2
A1
M
F1
F10
Lower edge of actuator
C4
Ø d1
C3
C2
N2 F07
Option:
C1
C
Local controls VSE
Ø d2
G2
A3
M
Ø D1
F2
Ø d1
Emergency operation module FSC20/ F12
transformer housing PEL-DS
G3
Ø d2
F3
Ø d7 H8 from 22 30
to 30 38
b JS9 1) 8 10
t 3.3 +0.1 3.3 +0.2
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
B2
EQ 40 – EQ 150 EQ 300/EQ 600 B1
with base and lever with base and lever
B2
B1
B B
Ø d1
Ø d1
Ø d2
Ø d2
H
H
H2
H2
H1
H1
h
h
h2
h2
h1
h1
C1 Ø d3 C1 Ø d3
C M C M
tapered hole 1:10
h3
h1
h1
tapered hole 1:10
Ø D2
ØD
H2
L max.
P
H3
h2
h
Ø d2
d4
A
Ø d3
Ø d1
C2 C1
C
Ø D1
H1
Stem nut Ø d5
Dimensions SD 05 – SD 25
EN ISO 5210 F07 F10
Type F max. kN 40 70
EN ISO 5210 A Ø d1 90 125
L
g
Ø d6
Ø d2 55 70
h3
Ø d3 70 102
h
–h
d4
>
Ø d2 M8 M10
Zxd4
Ø d3 Ø d5 22 27
Ø d1
Ø d6 max. 2) 20 26
g 40 50
F07 F07 3) F10 h 3 3
Arrangement of h3 12 15
holes d4
L 37 47
L max. 130 170 3)
135
L max.
L max.
Z 4 4
L max.
Square bore
Dimensions SD 05 – SD 25
According to EN ISO 5211
EN ISO 5210 F10
ØD 24,8
Ø d8 max. 14,1 18,1
L4 25
s H11 min. – 11
s H11 max. 11 14
Valve attachment
g
F05
h3
h3
h2
h
L
Ø d4
Ø d3
Ø d2
H
L4
L2
Ø d8
Ø d9
Ø d1
Standard version, multi-turn actuator clockwise rotation Stem is extended
For dimmensions of multi-turn actuators refer to "Dimensions SD 05 – SD 25 multi-turn actuators"
Dimensions SDL 50-10/-20/-30 SDL 100-20/-30
DIN 3358 F05 F07
H (stroke) 55 85
L 34 48
L2 28 28
L4 45 51
Ø d1 70 95
Ø d2 35 55
Ø d3 50 70
Ø d4 M6 M8
Ø d8 M12 x 1.25 M16 x 1.5
Ø d9 60 60
g 56 102
h 3 3
h2 – 22
h3 15 15
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
C6
C C2
F F
HH
H6
Bayonet variant
Plug/socket connector (option)
H2
H3
E2
H1
H8
h1
”X”
H5
H5
H7
H4
AUMA plug/socket z x d4
A3 connector variant (option)
E1 Ø d3
Ø d1
B1
E1
E
20° Screw-type 20°
connector variant (standard)
Detail X
SVC 05.1 – SVC 07.5
SVCR 05.1 – SVCR 07.5 Y version
A1 with spigot
L max.
C5
C4
h
C3
Ø d7
Valve attachment according to
Ø d2 EN ISO 5211
Ø D1
Dimensions of couplings see overleaf
L5
to DIN 6885-1 ØD 31.75 41.75 51.75
Detail X b JS9 1) 6 6 8
Detail X Ø d7 H8 2) 18 22 28
Ø d7 max. 20 25.4 38
d9 3) M4 M5 M6
1,5 x d9 L4 35 35 45
L5 3) 8 8 10
M 20 20 35
t 1) 20.8 24.8 31.3
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
H6
Plug/socket connector (option)
HH
H2
H3
E2
H1
H5
H5
A3
H8
H7
H4
AUMA plug/socket
connector variant (option)
h1
1)
"X"
h
E1 Ø d5
Screw-type
20° connector variant (standard) Ø d2
B1
Ø d3 z x d4
E
Ø d1
Detail X E1
J
20°
C5
5211
Dimensions of couplings see overleaf
C3
Ø d7
h 1)
Ø D1
1) Allowance for spigot is not available as standard The spigot ring is a separate component, available as option.
Dimensions SGC/SGCR 12.1
EN ISO 5211 F12 F14 F16
A1 66.5
A3 80
B1 94.5
C 155
C1 210
C2 99
C3 47
C5 150
C6 310
Ø D1 125
E 135
E1 100
E2 115
F 123
H1 101.5
H2 219
H3 190
H4 144
H5 10
H6 23
H7 81
H8 394 434 444
HH min. 30
J 109
L max. 61 101 111
Ø d1 150 175 210
Ø d2 f8 85 100 130
Ø d3 125 140 165
d4 M12 M16 M20
Ø d5 210
Ø d7 15
h 1) 2.5 3.5 4.5
h1 22 25 32
z 4
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Bore according to
Dimensions SGC/SGCR 12.1
EN ISO 5211
With keyway according to EN ISO 5211 F12 F14 F16
DIN 6885-1 ØD 67.6
L5
b JS9 1) 10
Detail X Ø d7 H8 2) 36
Detail X Ø d7 max. 50
d9 3) M6
1,5 x d9
L4 55 95 105
L5 3) 10
M 40
t 1) 39.3
Square bore
Dimensions SGC/SGCR 12.1
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Output drives
5. Dimensions
Dimensions Valve attachments for actuators and gearboxes
Comparison between EN ISO 5210/EN ISO 5211 and DIN 3210/DIN 3338
EN ISO 5210 Multi-turn valve actuator attachments
EN ISO 5211 Part-turn valve actuator attachments
DIN 3210 Output drives of electric actuators for valves (Standard withdrawn)
DIN 3338 Multi-turn actuator attachments, type C
Actuator
h1
(d3) (d3)
Ø d4 Ø d2 Ø d2 Ø d4
Designations deviating from EN ISO
Ø d3 (k) Ø d3 (k)
Ø d1 Ø d1 are indicated in brackets
1) Deviating dimensions between EN ISO 5210/EN ISO 5211/DIN 3338 and DIN 3210
rising, non-rotating
A A – X X
valve stem
rotating, non-rising
B1
B – X – valve stem or rising,
B2
non-rotating valve stem
Dog coupling
rotating, non-rising
– C C X – valve stem or rising,
non-rotating valve stem
Shaft end
Operation via
– D – X – lever arrangement or
coupling
B3 rotating, non-rising
E – X –
B4 valve stem
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Detail X
X
Z
2) Article number refers to
unbored version, KN, KS
3) Combined flange F05/F07 without spigot (standard).
As an alternative an individual flange F07 can be ordered with/without spigot
Article Splined
Ø d7 Ø d7 H8 b Parallel key Grub screw 1)
Type ØD L4 M coupling Q Ø d9 1) L5 1) Z
no. 2)
DIN 5480 max. over to JS 9 DIN 6885-1 ISO 4029
12 15 5 2.3 + 0.1 5 x 5 x ..
SG 03.3/SG 04.3 Z009.977 24.8 25 17 25x1x24 15 10 12 4 1.8 + 0.1 4 x 4 x .. M4 5 M4 x 4 6
8 10 3 1.4 + 0.1 3 x 3 x ..
12 15 5 2.3 + 0.1 5 x 5 x ..
SG 04.2 Z009.992 24.8 35 17 25x1x24 15 10 12 4 1.8 + 0.1 4 x 4 x .. M4 8 M4 x 4 6
8 10 3 1.4 + 0.1 3 x 3 x ..
SGC 04.1/05.1
17 20 6 2.8 + 0.1 6 x 6 x ..
SVC/SVM 05.1
SG 05.2
SG 05.3 Z010.132 31.75 35 20 32x1.25x24 20 12 17 5 2.3 + 0.1 5 x 5 x .. M4 8 M4 x 4 6
GS 50.3 F05
GHE 05.1
10 12 4 1.8 + 0.1 4 x 4 x ..
SGM 04.1/05.1
SGC/SGM 07.1
22 25.4 8 3.3 + 0.2 8 x 7 x ..
SQ 05.2 – F05/F07 3)
SQ 07.2 – F05/F07 3)
Z010.369 41.75 35 20 42x1.25x32 25.4 17 22 6 2.8 + 0.2 6 x 6 x .. M5 8 M5 x 5 7.5
SG 07.2
GHE 07.1
12 17 5 2.3 + 0.1 5 x 5 x ..
SVC/SVM 07.1/5
22 25.4 8 3.3 + 0.2 8 x 7 x ..
SG 05.1/SG 07.1 Z010.169 41.75 40 20 42x1.25x32 25.4 17 22 6 2.8 + 0.1 6 x 6 x .. M5 8 M5 x 5 7.5
12 17 5 2.3 + 0.1 5 x 5 x ..
22 25.4 8 3.3 + 0.2 8 x 7 x ..
SQ 07.2 – F10 Z010.658 41.75 60 20 42x1.25x32 25.4 17 22 6 2.8 + 0.1 6 x 6 x .. M5 8 M5 x 5 7.5
12 17 5 2.3 + 0.1 5 x 5 x ..
SGC/SGM 10.1
30 38 10 3.3 + 0.2 10 x 8 x ..
SQ 10.2 – F10
GS 50.3 Z010.302 51.75 45 30 52x1.25x40 38 22 30 8 3.3 + 0.2 8 x 7 x .. M6 10 M6 x 6 9
GHE 10.1
17 22 6 2.8 + 0.1 6 x 6 x ..
SG 10.2
30 38 10 3.3 + 0.2 10 x 8 x ..
SG 10.1 Z010.328 51.75 65 35 52x1.25x40 38 22 30 8 3.3 + 0.2 8 x 7 x .. M6 10 M6 x 6 9
17 22 6 2.8 + 0.1 6 x 6 x ..
30 38 10 3.3 + 0.2 10 x 8 x ..
SQ 10.2 – F12 Z044.911 51.75 75 30 52x1.25x40 38 22 30 8 3.3 + 0.2 8 x 7 x .. M6 10 M6 x 6 9
17 22 6 2.8 + 0.1 6 x 6 x ..
SQ 12.2 – F12 44 50 14 3.8 + 0.2 14 x 9 x ..
GS 63.3 Z010.368 67.6 55 40 68x2x32 50 38 44 12 3.3 + 0.2 12 x 8 x .. M6 10 M6 x 6 9
GHE 12.1 30 38 10 3.3 + 0.2 10 x 8 x ..
44 50 14 3.8 + 0.2 14 x 9 x ..
SG 12.1 Z010.184 67.6 75 40 68x2x32 50 38 44 12 3.3 + 0.2 12 x 8 x .. M6 10 M6 x 6 9
30 38 10 3.3 + 0.2 10 x 8 x ..
44 50 14 3.8 + 0.2 14 x 9 x ..
SQ 12.2 – F14 Z006.070 67.6 95 40 68x2x32 50 38 44 12 3.3 + 0.2 12 x 8 x .. M6 10 M6 x 6 9
30 38 10 3.3 + 0.2 10 x 8 x ..
44 50 14 3.8 + 0.2 14 x 9 x ..
SQ 12.2 – F16 Z006.071 67.6 105 40 68x2x32 50 38 44 12 3.3 + 0.2 12 x 8 x .. M6 10 M6 x 6 9
30 38 10 3.3 + 0.2 10 x 8 x ..
SQ 14.2 – F14 58 60 18 4.4 + 0.2 18 x 11 x ..
Z010.394 81.6 65 47 82x2x40 60 50 58 16 4.3 + 0.2 16 x 10 x .. M6 10 M6 x 6 9
GS 80.3 44 50 14 3.8 + 0.2 14 x 9 x ..
58 60 18 4.4 + 0.2 18 x 11 x ..
SQ 14.2 – F16 Z111.676 81.6 115 40 82x2x40 60 50 58 16 4.3 + 0.2 16 x 10 x .. M6 10 M6 x 6 9
44 50 14 3.8 + 0.2 14 x 9 x ..
75 80 22 5.4 + 0.2 22 x 14 x ..
GS 100.3 Z015.955 105.8 80 50 106x2x52 80 65 75 20 4.9 + 0.2 20 x 12 x .. M8 18 M8 x 8 12
58 65 18 4.4 + 0.2 18 x 11 x ..
85 90 25 5.4 + 0.2 25 x 14 x ..
GS 125.3 Z017.441 119.6 110 70 120x2x60 90 75 85 22 5.4 + 0.2 22 x 14 x .. M8 18 M8 x 8 12
65 75 20 4.9 + 0.2 20 x 12 x ..
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
L6
Detail X L51) 9 1)
X
d15
Z
1) Thread with grub screw made of A2
2) Article number refers to unbored version, KN, KS M
3) DIN 475
4) Combined flange F05/F07 without spigot (standard).
As an alternative an individual flange F07 can be ordered with/without spigot
Article Splined S H11 Ø d8 Grub screw 1)
Type ØD L4 M coupling L6 Ø d9 1) Ø d15 L5 1) Z
no. 2) DIN 5480 over to max. ISO 4029
11 14.1
SG 03.3/SG 04.3 Z009.977 24.8 25 17 25x1x24 25 M4 16 5 M4 x 4 6
11 14 18.1
11 14.1
SG 04.2 Z009.992 24.8 35 17 25x1x24 25 M4 16 8 M4 x 4 6
11 14 18.1
SGC 04.1/05.1
11 14.1 25 16
SVC/SVM 05.1
SG 05.2
SG 05.3 Z010.132 31.75 35 20 32x1.25x24 11 16 3) 18 3) 25 M4 22.5 8 M4 x 4 6
GS 50.3 F05
GHE 05.1
16 3) 17 22.2 30 25
SGM 04.1/05.1
SGC/SGM 07.1
SQ 05.2 – F05/F07 4) 11 16 3) 18 3) 25 22.5
SQ 07.2 – F05/F07 4)
Z010.369 41.75 35 20 42x1.25x32 M5 8 M5 x 5 7.5
SG 07.2
GHE 07.1 16 3) 22 28.2 30 31
SVC/SVM 07.1/5
11 16 3) 18 3) 25 22.5
SG 05.1/SG 07.1 Z010.169 41.75 40 20 42x1.25x32 M5 8 M5 x 5 7.5
16 3) 22 28.2 30 31
11 16 3) 18 3) 25 22.5
SQ 07.2 – F10 Z010.658 41.75 60 20 42x1.25x32 M5 8 M5 x 5 7.5
16 3) 22 28.2 30 31
SGC/SGM 10.1
11 16 3) 18 3) 25 22.5
SQ 10.2 – F10
3)
GS 50.3 Z010.302 51.75 45 30 52x1.25x40 16 22 28.2 30 M6 31 10 M6 x 6 9
GHE 10.1
22 27 36.2 40 41
SG 10.2
11 16 3) 18 3) 25 22.5
SG 10.1 Z010.328 51.75 65 35 52x1.25x40 16 3) 22 28.2 30 M6 31 10 M6 x 6 9
22 27 36.2 40 41
11 16 3) 18 3) 25 22.5
SQ 10.2 – F12 Z044.911 51.75 75 30 52x1.25x40 16 3) 22 28.2 30 M6 31 10 M6 x 6 9
22 27 36.2 40 41
SQ 12.2 – F12 16 3) 22 28.2 30 31
GS 63.3 Z010.368 67.6 55 40 68x2x32 22 27 36.2 40 M6 41 10 M6 x 6 9
GHE 12.1 27 36 (41 3)) 48.2 (48 3)) 45 53
16 3) 22 28.2 30 31
SG 12.1 Z010.184 67.6 75 40 68x2x32 22 27 36.2 40 M6 41 10 M6 x 6 9
27 36 (41 3)) 48.2 (48 3)) 45 53
16 3) 22 28.2 30 31
SQ 12.2 – F14 Z006.070 67.6 95 40 68x2x32 22 27 36.2 40 M6 41 10 M6 x 6 9
27 36 (41 3)) 48.2 (48 3)) 45 53
16 3) 22 28.2 30 31
SQ 12.2 – F16 Z006.071 67.6 105 40 68x2x32 22 27 36.2 40 M6 41 10 M6 x 6 9
27 36 (41 3)) 48.2 (48 3)) 45 53
SQ 14.2 – F14 22 27 36.2 40 41
Z010.394 81.6 65 47 82x2x40 27 36 (41 3)) 48.2 (48 3)) 45 M6 53 10 M6 x 6 9
GS 80.3 36 (41 3)) 46 60.2 59 64
22 27 36.2 40 41
SQ 14.2 – F16 Z111.676 81.6 115 40 82x2x40 27 36 (41 3)) 48.2 (48 3)) 45 M6 53 10 M6 x 6 9
36 (41 3)) 46 60.2 59 64
27 36 (41 3)) 48.2 (48 3)) 45 53
GS 100.3 Z015.955 105.8 80 50 106x2x52 36 (41 3)) 46 60.2 59 M8 64 18 M8 x 8 12
46 55 72.2 77 85
36 (41 3)) 46 60.2 59 64
GS 125.3 Z017.441 119.6 110 70 120x2x60 46 55 72.2 77 M8 85 18 M8 x 8 12
55 75 98.2 94 95
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
∅
d15
d9
1)
Z
1) Thread with grub screw made of A2
2) Article number refers to unbored version, KN, KS
3) DIN 79 M
4) Combined flange F05/F07 without spigot (standard). L
As an alternative an individual flange F07 can be ordered with/without spigot
Article Splined S H11 Ø d8 Grub screw 1)
Type ØD L4 M coupling L6 Ø d9 1) Ø d15 L5 1) Z
no. 2)
DIN 5480 over to max. ISO 4029
11 14.1
SG 03.3/SG 04.3 Z009.977 24.8 25 17 25x1x24 25 M4 16 5 M4 x 4 6
11 14 18.1
11 14.1
SG 04.2 Z009.992 24.8 35 17 25x1x24 30 M4 16 8 M4 x 4 6
11 14 18.1
SGC 04.1/05.1
11 14.1 16
SVC/SVM 05.1
SG 05.2
SG 05.3 Z010.132 31.75 35 20 32x1.25x24 11 14 18.1 30 M4 20 8 M4 x 4 6
GS 50.3 F05
GHE 05.1
14 17 22.2 24
SGM 04.1/05.1
SGC/SGM 07.1
11 14 18.1 20
SQ 05.2 – F05/F07 4)
SQ 07.2 – F05/F07 4)
Z010.369 41.75 35 20 42x1.25x32 14 17 22.2 30 M5 24 8 M5 x 5 7.5
SG 07.2
GHE 07.1
17 22 28.2 31.5
SVC/SVM 07.1/5
11 14 18.1 20
SG 05.1/SG 07.1 Z010.169 41.75 40 20 42x1.25x32 14 17 22.2 30 M5 24 8 M5 x 5 7.5
17 22 28.2 31.5
11 14 18.1 20
SQ 07.2 – F10 Z010.658 41.75 60 20 42x1.25x32 14 17 22.2 30 M5 24 8 M5 x 5 7.5
17 22 28.2 31.5
SGC/SGM 10.1
14 17 22.2 30 24
SQ 10.2 – F10
GS 50.3 Z010.302 51.75 45 30 52x1.25x40 17 22 28.2 30 M6 31.5 10 M6 x 6 9
GHE 10.1
22 30 3) 40.2 3) 40 41.5
SG 10.2
14 17 22.2 30 24
SG 10.1 Z010.328 51.75 65 35 52x1.25x40 17 22 28.2 30 M6 31.5 10 M6 x 6 9
22 30 3) 40.2 3) 40 41.5
14 17 22.2 30 24
SQ 10.2 – F12 Z044.911 51.75 75 30 52x1.25x40 17 22 28.2 30 M6 31.5 10 M6 x 6 9
22 30 3) 40.2 3) 40 41.5
SQ 12.2 – F12 17 22 28.2 30 31.5
GS 63.3 Z010.368 67.6 55 40 68x2x32 22 30 3) 40.2 3) 40 M6 41.5 10 M6 x 6 9
GHE 12.1 30 3) 36 48.2 50 50
17 22 28.2 30 31.5
SG 12.1 Z010.184 67.6 75 40 68x2x32 22 30 3) 40.2 3) 40 M6 41.5 10 M6 x 6 9
30 3) 36 48.2 50 50
17 22 28.2 30 31.5
SQ 12.2 – F14 Z006.070 67.6 95 40 68x2x32 22 30 3) 40.2 3) 40 M6 41.5 10 M6 x 6 9
30 3) 36 48.2 50 50
17 22 28.2 30 31.5
SQ 12.2 – F16 Z006.071 67.6 105 40 68x2x32 22 30 3) 40.2 3) 40 M6 41.5 10 M6 x 6 9
30 3) 36 48.2 50 50
SQ 14.2 – F14 22 30 3) 40.2 3) 40 41.5
Z010.394 81.6 65 47 82x2x40 30 3) 36 48.2 50 M6 50 10 M6 x 6 9
GS 80.3 36 46 60.2 50 64
22 30 3) 40.2 3) 40 41.5
SQ 14.2 – F16 Z111.676 81.6 115 40 82x2x40 30 3) 36 48.2 50 M6 50 10 M6 x 6 9
36 46 60.2 50 64
30 3) 36 48.2 50 50
GS 100.3 Z015.955 105.8 80 50 106x2x52 36 46 60.2 50 M8 64 18 M8 x 8 12
46 55 72.2 60 82
36 46 60.2 50 64
GS 125.3 Z017.441 119.6 110 70 120x2x60 46 55 72.2 60 M8 82 18 M8 x 8 12
55 75 98.2 80 95
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Basic Range
EQ 40 – EQ 600 117
Smart Range
SD 118
SDL 100 119
Bitte geben Sie bei Bestellung von Ersatzteilen die Fertigungsnummer des Antriebes an.
Please provide serial number of actuator (“F-Nr.”), when ordering spare parts.
Bitte geben Sie bei Bestellung von Ersatzteilen die Fertigungsnummer des Antriebes an.
Please provide serial number of actuator (“F-Nr.”), when ordering spare parts.
Bitte geben Sie bei Bestellung von Ersatzteilen die Fertigungsnummer des Antriebes an.
Please provide serial number of actuator (“F-Nr.”), when ordering spare parts.
Part-turn actuators
SGC 04.1 - SGC 10.1
002.3 - 2 002.0 - 3 SGCR 04.1 - SGCR 10.1
002.0 - 2
S1
002.3 -1
002.0 -1
S1
611.0 S1 542.0
009.0
006.0
539.0
525.0 S1
541.0
545.0-2 545.0-2
542.1
545.0-1 587.0
545.0-3
002.3 -1
002.0 -1
545.0-3
545.0-3 541.0
1.15
Y004.979/003/en
SGC 04.1 - SGC 10.1
SGCR 04.1 - SGCR 10.1
Spare parts list part-turn actuators
Please state type and order no. of the device (see name plate) when ordering spare parts. Only original AUMA spare parts should be
used. Failure to use original spare parts voids the warranty and exempts AUMA from any liability. Delivered spare parts may slightly vary
from the representation.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Part-turn actuators
002.3 - 2 SGC 12.1
002.0 - 3
SGCR 12.1
507.0 545.0 - 3
501.0
503.0 502.0 500.0
S1 S1
504.0 505.0 S1 002.3 - 1
611.0 S1
506.0
002.0 - 2
S1
587.0
002.0 - 1
002.3 - 1 545.0 - 3
002.0 - 1 541.0
S1
611.0
009.0 S1
006.0 542.0
539.0
541.0
548.0
545.0 - 3
545.0 - 1 010.0
545.0 - 2
542.1
609.1
610.1
522.0
596.0
S1
545.0 - 2
612.0
545.0 - 3 525.0
1.15
Y006.454/003/en
SGC 12.1
SGCR 12.1
Spare parts list part-turn actuators
Please state type and order no. of the device (see name plate) when ordering spare parts. Only original AUMA spare parts should be
used. Failure to use original spare parts voids the warranty and exempts AUMA from any liability. Delivered spare parts may slightly vary
from the representation.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Part-turn actuators
SGC 04.1 - SGC 10.1
002.3 - 2 002.0 - 3 SGCR 04.1 - SGCR 10.1
Fieldbus
002.0 - 2
S1
002.3 -1
002.0 -1
S1
611.0 S1 542.0
009.0
006.0
539.0
525.0 S1
541.0
545.0-2 545.0-2
542.1
545.0-1 587.0
545.0-3
002.3 -1
002.0 -1
545.0-3
545.0-3 541.0
1.15
Y004.980/003/en
SGC 04.1 - SGC 10.1 Fieldbus
SGCR 04.1 - SGCR 10.1 Fieldbus
Spare parts list part-turn actuators
Please state type and order no. of the device (see name plate) when ordering spare parts. Only original AUMA spare parts should be
used. Failure to use original spare parts voids the warranty and exempts AUMA from any liability. Delivered spare parts may slightly vary
from the representation.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Part-turn actuators
002.3 - 2 SGC 12.1
002.0 - 3
SGCR 12.1
507.0 545.0 - 3 Fieldbus
501.0
503.0 502.0 500.0
S1 S1
504.0 505.0 S1 002.3 - 1
611.0 S1
506.0
002.0 - 2
S1
587.0
002.0 - 1
002.3 - 1 545.0 - 3
002.0 - 1 541.0
S1
611.0
009.0 S1
006.0 542.0
539.0
541.0
548.0
545.0 - 3
545.0 - 1 010.0
545.0 - 2
542.1
609.1
610.1
610.1
522.0
596.0
S1
545.0 - 2
612.0
545.0 - 3 525.0
1.15
Y006.455/003/en
SGC 12.1 Fieldbus
SGCR 12.1 Fieldbus
Spare parts list part-turn actuators
Please state type and order no. of the device (see name plate) when ordering spare parts. Only original AUMA spare parts should be
used. Failure to use original spare parts voids the warranty and exempts AUMA from any liability. Delivered spare parts may slightly vary
from the representation.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
002.0 - 2
S1
002.3 -1
002.0 -1
S1
611.0
542.0
009.0
006.0 S1
539.0
S1
525.0
541.0
545.0-2 545.0-2
542.1
545.0-1 587.0
545.0-3
002.3 -1
002.0 -1
545.0-3
545.0-3 541.0
1.15
Y004.977/002/en
SVC 05.1 - SVC 07.5
SVCR 05.1 - SVCR 07.5
Spare parts list globe valve actuators
Please state type and order no. of the device (see name plate) when ordering spare parts. Only original AUMA spare parts should be
used. Failure to use original spare parts voids the warranty and exempts AUMA from any liability. Delivered spare parts may slightly vary
from the representation.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
002.0 - 2
S1
002.3 -1
002.0 -1
S1
611.0
542.0
009.0
006.0 S1
539.0
S1
525.0
541.0
545.0-2 545.0-2
542.1
545.0-1 587.0
545.0-3
002.3 -1
002.0 -1
545.0-3
545.0-3 541.0
1.15
Y004.978/002/en
SVC 05.1 - SVC 07.5 Fieldbus
SVCR 05.1 - SVCR 07.5 Fieldbus
Spare parts list globe valve actuators
Please state type and order no. of the device (see name plate) when ordering spare parts. Only original AUMA spare parts should be
used. Failure to use original spare parts voids the warranty and exempts AUMA from any liability. Delivered spare parts may slightly vary
from the representation.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Basic Range
Selection of wiring diagrams 134
Smart Range
Selection of wiring diagrams 147
7. Wiring diagrams
Basic Range
NR / 1-phase AC
C1: 2 x limit switches
Represented options:
Additional limit switches
Potentiometer
Positioning electronics
NR2.1-170.050.10
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
ED / DC 24 V
D1: External reversing contactor unit
2 x limit switches
Represented options:
Additional limit switches
Heater
Potentiometer
Position feedback signal (0/4 – 20 mA)
ED50-170.050.01
EQ / 1-phase AC 230 V
D2: 2 x limit switches, 2 x torque switches
Represented options:
Additional limit switches
Heater
Potentiometer
Position feedback signal (0/4 – 20 mA)
EQ150-170.050.00
EQ / Gleichstrom 24 V
D3: External reversing contactor unit
2 x limit switches, 2 x torque switches
Represented options:
Additional limit switches
Heater
Potentiometer
Position feedback signal (0/4 – 20 mA)
EQ150-170.050.01
EQ / 3-phase AC 400 V
D4: Internal reversing contactor unit
2 x limit switches, 2 x torque switches
Represented options:
Additional limit switches
Heater
Potentiometer
Position feedback signal (0/4 – 20 mA)
EQ150-170.050.02
EQ / 1-phase AC 230 V
D5: 2 x limit switches, 2 x torque switches
Represented options:
Additional limit switches
Heater
Potentiometer
Positioning electronics
Position feedback signal (0/4 – 20 mA)
EQ150-170.050.03
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
Subject to changes without notice. The product features and technical data provided do not express or imply any warranty. Y007.568/003/en/1.17