You are on page 1of 2

SHRI BALAJI CONSULTANCY

DESIGN OF LINTEL BEAMS

Job name PRINTING CLUSTURE FOR UNIGRAA AT SIVAKASI.


Job number = 2011/1/ind
Characteristic strength of concrete = 20.000 N/mm2
Yield stress of steel = 415.00 N/mm2
Unit weight of reinforced concrete = 25.000 kN/m3
Unit wt of brick masonry = 19.200 kN/m3
Clear cover = 25.000 mm
Height of brick wall (including lintel thickness) = 1981.000 mm
Length of sun shade = 762.000 mm
Thickness of sun shade = 50.0000 mm
Thickness of wall = 230.000 mm
Live load on sunshade = 0.750 kN/m2
End point load on sunshade = 0.000 kN/m
Self wt of sunshade = 0.953 kN/m

Weight No of
Lintel Size of beam Clear Eff. Factored Torsional Equivalent Eff. Min. Max. Reqd. Dia of Provided
Bearing of brick Moment rods
tag span span Load moment moment depth Ast Ast Ast rods Ast Check
(m) wall (kNm) require
no. Width Depth (m) (m) (kN/m) (kN/m) (kN/m) (mm) (mm2) (mm2) (mm2) (mm) (mm2)
(m) (m) (kN/m) d
LB1 0.23 0.45 4.683 0.300 4.983 6.761 16.309 0.581 1.515 52.133 419 212 4140 350.7 12 4 452.3893 Safe
LB2 0.23 0.3 3.048 0.300 3.348 7.423 16.008 0.581 1.181 23.611 269 141 2760 247.8 12 3 339.292 Safe
LB3 0.23 0.15 1.828 0.230 2.058 8.086 15.708 0.581 0.846 9.163 119 71 1380 221.8 12 2 226.1947 Safe
LB4 0.23 0.15 1.219 0.230 1.449 8.086 15.708 0.581 0.846 4.969 121 71 1380 116.1 8 3 150.7964 Safe
LB4 0.23 0.15 1.219 0.230 1.449 8.086 15.708 0.581 0.846 4.969 121 71 1380 116.1 8 3 150.7964 Safe
LB4 0.23 0.15 1.219 0.230 1.449 8.086 15.708 0.581 0.846 4.969 121 71 1380 116.1 8 3 150.7964 Safe
LB4 0.23 0.15 1.219 0.230 1.449 8.086 15.708 0.581 0.846 4.969 121 71 1380 116.1 8 3 150.7964 Safe